Kohler 5EKD Generator Test Run and FAIL!

Поділитися
Вставка
  • Опубліковано 14 січ 2025

КОМЕНТАРІ • 14

  • @abbaboiz69
    @abbaboiz69 Рік тому +1

    Notice the expanded hose to the fuel cooler from the raw water pump. Water pressure is too low as measured by the pressure sensor on the outlet of the heat exchanger. Likely pieces of old impeller sitting at the start of the heat exchanger.

  • @maryfoard5726
    @maryfoard5726 3 роки тому +1

    Very helpful. We have one of these (with under 10 hours) and the loss of coolant error code comes up regularly.

    • @DavidWilks
      @DavidWilks  3 роки тому

      Check to see if your water pump pressure sensor is corroded. The sea-water pump can have low pressure due to a strainer and also trigger that code.

    • @kurtverhoeven7240
      @kurtverhoeven7240 2 роки тому

      Hi dave
      I have l.o.c error but my boat is dry docked without any access to water. Do i need water to run the generator to confirm there are no errors. You suggested pressure sea pump sensor i have checked and there is know water therefore the error has appeared? I dont have a HET exhaust sensor.

  • @Hubjeep
    @Hubjeep 3 роки тому

    5:42 Looks like someone spray painted that area, see over-spray on the worm-drive hose clamp.

  • @kirkdas2982
    @kirkdas2982 2 роки тому

    So what was the outcome ? Was it the waterpump or sensor?

    • @mattm1925
      @mattm1925 5 місяців тому

      Based on the hoses swelling, the impeller grenaded and debris is blocking heat exchanger flow

  • @Hubjeep
    @Hubjeep 3 роки тому +1

    It's crazy that has a catalytic converter and oxygen sensor! Tier 4? Friend of mine has a big Cat diesel generator, gets fault codes often.

    • @DavidWilks
      @DavidWilks  3 роки тому

      Once I got it sorted out, it was a quiet and extremely efficient but it was a monster to diagnose this unit.

    • @HorseHavenRanch1996
      @HorseHavenRanch1996 3 роки тому +1

      Was it due to that drip in the pump assembly? I'm having this same issue.

    • @ricklaviolette4068
      @ricklaviolette4068 2 роки тому

      Same issue. What was it???

  • @bebithtchcantiples2620
    @bebithtchcantiples2620 Рік тому

    how to fix problem volts L3-L1 low shutdown

    • @mattm1925
      @mattm1925 5 місяців тому

      Hard reset the unit. Works on Industrial kohlers

  • @summitdave8782
    @summitdave8782 3 роки тому

    Wow...A crack...Not cool....