- 51
- 82 522
david betts
Приєднався 2 тра 2015
SMC ITV Proportional Regulator. Sensitivity Adjustment. Eliminate the "Buzzing or Oscillating."
How to reduce or eliminate the "Buzzing or Oscillating." Please use caution is changing the sensitivity. Although it can minimize the annoyance noise, it also reduces the time for the set pressure to adjust.
Переглядів: 633
Відео
SMC Soft Start Mechanical SSC ASS300
Переглядів 34010 місяців тому
SMC offers both solenoid and mechanical "Soft Start" valves to prevent sudden cylinder movement. Sudden lurching or movement occurs when the machine or pneumatic system is re-started AFTER it has been de-pressurized or vented. Primarily caused by the cylinder(s) last position in mid-stroke or at end of stroke and there is no backpressure to hold the cylinder piston. Even with meter out speed co...
SMC Actuators MGZ and MGPM Comparison. Problem Solving.
Переглядів 12910 місяців тому
Problem solving with SMC Pneumatic Cylinders. The customer needed a high force, high side load actuator that ALSO had minimal static friction. I compared the 2 cylinders that are both 25mm bore. Using the ITV Proportional regulator I slowly ramped up pressure to see which cylinder began moving at the lower pressure. The MGZ catalog does show slightly lower minimum operating pressure, and this t...
SMC Valve Solenoid Manifold Configurator
Переглядів 51910 місяців тому
Create a Bill of Materials, CAD model and Schematic in 6 minutes. SY series Solenoid Valves on a 16 station ProfiNET manifold. This example is using metric fittings, but inch tubing connections are also available. More detailed configurations are possible. Please email me directly and include your company name and plant location and I will be happy to assist or coordinate SMC technical support ...
SMC IR series precision vs AR series standard regulators
Переглядів 15711 місяців тому
Standard regulators are typically "Relieving." You can order them Non-Relieving but they are not as common. In a circuit where the pneumatic pressure must be controlled within 0.5% of Full Scale, please select our IR series precision regulators. They are a relieving type and only a little more expensive than standard AR series regulators. One MAIN DIFFERENCE is they have an Exhaust Port in whic...
Pneumatic Schematics 002 - Create, Save, Download, Export
Переглядів 9611 місяців тому
How to video series. This schematic will include: Pressure Source, Manual Lockout valve, FIlter (5 micron) Regulator, Coalescing Filter (0.3 micron), Soft Start with Solenoid dump, Tee fitting, 3way Push Button valve, Meter IN speed control, Single Acting Spring return cylinder, 5/2 Single Solenoid 4way valve, quick exhaust speed control, and a double acting cylinder.
Pneumatic Schematic Overview
Переглядів 17611 місяців тому
This is a how to video series that will assist in creating pneumatic schematics. Included in this video are 3 way manual lockout valve, Filter-Regulator, Coalescing Filter and a Double redundant Safety Venting valve. Subsequent videos will go further into different Air filtration circuits, Valve type and manifolds as well as circuits that include speed controls, quick exhaust, and pilot operate...
SMC ITV Proportional Pressure Regulator
Переглядів 1 тис.Рік тому
Purpose of this video is to show how fast the regulator relieves downstream pressure when there is an excessive length of tubing between a pneumatic cylinder and the regulator. There is 36ft of 6mm tubing between the ITV outlet and the Cylinder Head port. External force being applied to the cylinder rod simulates a constant load in the retract direction. Pressure is increased and decreased via ...
SMC AXTS Pulse Blowing Valve
Переглядів 857Рік тому
Compressed Air is not free. This valve can simply be installed near a nozzle and create an ON-OFF pulse of air. The peak opressure of repeatedly colliding air permits efficient blowing. Air consumption reduced by 50% or more. ON-OFF time is adjustable. Valve has 200 milllion cycle service life. Cv 2.9 or 3.4.
SMC AS-R Air Saving Speed Controller
Переглядів 233Рік тому
SMC ASR and ASQ series Air Saving Speed Controllers easily retrofit into existing or new equipment. The AS-R will be placed in the cylinder port for the "Non-Working" direction. This is typically the Rod Cover. The other port, is where EITHER an AS-Q (Press or Clamping) or a standard AS-F Meter-IN speed control would be used (Lifting or Transferring). The labels on the mini panel show 0.5MPa, b...
SMC Differential Pressure Sensor PSE550 with PSE300
Переглядів 1,2 тис.Рік тому
SMC Differential Pressure Sensor PSE550 with PSE300
SMC series VMG Blow Gun Test
Переглядів 412Рік тому
SMC series VMG Blow Gun. In this video I test our blow gun vs 2 units purchased from local hardware stores. Bottom line, compressed air is NOT free and the VMG Blow Gun does more "work" using LESS "cfm."
Air Management System by SMC Corp
Переглядів 946Рік тому
#morethanpneumatics SMC solves 3 challenges in ONE product. CO2 Reduction, Visualization, and Scalability. We fully understand the production requirements of manufacturers around the world and work tirelessly to increase machine efficiency and reeduce compressed air consumption. Using a built-in OPC-UA server we give your factory access to pressure, temperature and flow data in order to support...
SMC Flow Meter PFMB supplying ZNC Bernoulli
Переглядів 1542 роки тому
SMC Flow Meter PFMB supplying ZNC Bernoulli
SMC Vacuum ZNC Bernoulli & Wood Veneer
Переглядів 3162 роки тому
SMC Vacuum ZNC Bernoulli & Wood Veneer
SMC Pneumatic Gripper with Force Control
Переглядів 6 тис.3 роки тому
SMC Pneumatic Gripper with Force Control
SMC ZP3P vacuum cups, ZL6 venturi, ZP2V vacuum saving valves
Переглядів 6 тис.3 роки тому
SMC ZP3P vacuum cups, ZL6 venturi, ZP2V vacuum saving valves
SMC Digital Air Gap Checker ISA3 Series
Переглядів 1,4 тис.3 роки тому
SMC Digital Air Gap Checker ISA3 Series
SMC Vacuum Saving Valve. ZP2V. Test.
Переглядів 1,2 тис.4 роки тому
SMC Vacuum Saving Valve. ZP2V. Test.
SMC Vacuum Product Demo. ZP2V. Vacuum Saving Valve
Переглядів 1,7 тис.4 роки тому
SMC Vacuum Product Demo. ZP2V. Vacuum Saving Valve
SMC Vacuum Training XT661 Cyclone Bernoulli
Переглядів 1,8 тис.4 роки тому
SMC Vacuum Training XT661 Cyclone Bernoulli
SMC Vacuum Training ZP ZP2 ZP3 cup selection
Переглядів 2,9 тис.4 роки тому
SMC Vacuum Training ZP ZP2 ZP3 cup selection
Moore Jason Taylor Jason Rodriguez Christopher
Where is the PA connection connected to on the directional valve pilot port ?
Assuming it's not a spring return valve and the limit switch at the end of the rod stroke fully forward isn't connected.
Hi , can this VR 51 tie with solenoid valve ?
Would you be able to make your own makeshift Vr-51 and how?
Ethan, yes it's possible, but these list for around $230. I cannot provide a BOM but if you open the SMC "PneuDraw" (free) software, you can see the schematic symbol. The key item is the small reservoir that creates the 0.5sec requirement. If the 2 air inputs are NOT received within 0.5sec of each other the valve will NOT output a signal. Thank you, Dave
Great video! I was just talking about the XT661 (low profile) with customer last week!
it is possible to link my power supply io devices to monitor their usage ? currently i connected to io port 4 seems cant get connected
AMS is not shipped with IP address. It must be set in field. Please use IP Setting Tool, free download from SMCWORLD.COM
AMS has M12, IO-Link port which can be configured thru web browser as a digital IN or dig OUT. What is the mfg & part # you are trying to connect?
www.smcworld.com/manual/en-jp/?c1=A26
@@davidbetts1758 I had try phoenix contact power supply model Trio3-PS/1AC/24vdc/20/8C/IOL Connected to port 4 It show in general io link process data port status PD mapping mismatch , I put vendor id and device id with test byte swap also same My plc mapping I see smc already allocate offset input for it
What is default ip ? and the system configuration can use ip and browser on web ? currently i connected to eip port but unable to get connected and view web setting as well
Very sorry for delay. Only just now did I see your question. AMS default factory setting is NO IP address. Please find IP setting tool www.smcworld.com/manuals/en-jp/search?query=ex9&cd=1
No worry I already did it and video I had created thanks anyway ua-cam.com/video/uCc-AIuBL2g/v-deo.htmlsi=upxeDKYIhaNVZxfO
How profit if the machine always running 24hr.
If the machine is never idle, you would never enter stand by or isolation mode, therfore no savings from this features. Please share what is your operating pressure? Have you evaluated reducing supply by 2psi increments?
Awesome for new SMC product..
SMC good
「コンテンツを調整する必要があります」、
Specify the goal and need money
So we're calling advertisements "training" now?
How large can you make the pad? How much volume of air would you need for a 1ft dia circle. Can you make different shapes?
whether it can generate larger continuous positive pressure ?
Good day, besides a normal compressor ( the noisy ones we use to inflate tyres with) is there a more less noisy machine to generate pressure. Thanx in advance
Thank you for such great video. I have on query If we released one push button whether actuator will retract or we have to released both push buttons to retract
Very sorry for delay in replying. UA-cam is still new to me. Answer to your question, Yes, the cylinder will retract.
Compressed air should be supplied for this equipment
Why did you conect an eyector to the little ciclon pad? this pad doesn´t requiere vaccum
I made a mistake in a rush to finish the video. You are 100% correct, the venturi/ejector is NOT needed and not recommended in this application.
Do you have a vacuum flow meter? If yes, can you create a video where you show the vacuum flow you get from both ZL3 and Zl6?