What is difference between Tube and Pipe? | Tube Vs Pipe | Pipe in hindi | Tube in hindi |
Вставка
- Опубліковано 8 лют 2025
- Hello friends,
"Power plant discussion" welcome to all of you my friend to this channel, my name is chandan pathak, I have 10 years of experience in power plant operation field I have created this channel only for sharing knowledge about power plant operation and maintenance, for this I shall provide series of lecture on the various topic of power plant in which theoretical, practical and mathematical concepts are included.
Email
powerplantdiscussion@gmail.com
Website
/ @powerplantdiscussion (Company Website)
LinkedIn
/ power-plant-discussion...
#PowerPlantDiscussion
#TubePipe
Thanks to all of you for connecting me.
Good Information Sir
Very good bhai
Bahut badiya sir 👍
Excellent and very informative video thanks
It will be very helpful
Very well discussion this topic sir..
Bahut achha laga bhai apka video
Awesome explanation Bhai jee
All video's very good sir ji
Very helpfully video
Good Information
Thanks
Very nice explain and very informative.
Please make videos on Boiler heating surface Area calculation and which pressure parts are not considered for the calculation.
Thank you very much
Bro, needs to correct your video at 8:45 . In the case of pipe OD is always constant.
Example:
Pipe size: 1" it means OD is 33.4mm
Pipe size is 2", it means OD of pipe is 60.3mm.
If we change our schedule the ID of the pipe will change.
Good information, Thnx sir..
Supersir
Good explain sir....
very nice 💯
Very nice
Good explanation
Good explanation 👍
Please make a video on difference of IBR tube and normal tube.
Good sir
Good
Bhai
If we increase SCH , this will increase wall thickness so in that case internal id will be reduced but it will not increase outer diameter for same size(say 2”) of pipe with different sch 40&80
You r right
Pls share correct explanation boss...if u have
Right
U r right...for increasing or decreasing sch. Pipee ID will be decreasing and increasing respectively. ..you tuber need to correct himself
Correct.
V good sir .🎉🎉🎉🎉🎉🎉
Thanks sir
I am trom pakistan ,your all vedios are very helpful and much informative ,I appreciate you too much,. Would you please make the vedios for back pressure turbine kw calculations at different pressure in and out let with temperature difference.thanx for...
Thank you sir 🙏🙏
8:40 I think you are wrong. For the same NPS OD remains the same with schedule, and it is the ID that changes.
Yes I also Agree with you OD remains the same only ID change as per schedule.
Nice .
thanks a lot bhaiya
I like it
it's not necessary that tube always transfer heat, wrong concept. Copper tube use in plant to carry air not for heat transfer
Ek Detail video BCP pe bhi bana dijiye ...Plz
Thanks
Pathak jee plz make a vedio regarding fan chacterstist curve...
Bahot acha bataye hai sir g
Kindly centerifugal and steam turbine maintenance point of view .per video bnyia ga
Sir please information about induction motor rotor testing
sir, turbine rotor aur casing clearance kitna hota he.. moving aur fixed blade ka clearance kitna rehta he.. plzz explain
.05mm
Please watch my video on turbine rotor
@@chittaranjansahu8330 wrong bro....0.05mm me roll check nhi mil paayega
Pipe is denoted by nominal diameter and heat number instead of internal diameter..
💯💯
Pipe schedule ki bhi video benao
Sir. Turbine oil analysis par ek video please
Hello sir cgpsc le rha abhi boiler inspector ka question ka kuch idea de skte hai ky
Chiller inlet connection k bare mein pls video banaye
Sir, if we increase od of tube and decrease the Id, that time how heat will transfer.
For Heat transfer both I'd and od required right.
Please clarify my doubt
Nice🇧🇩
Please make videos on turbine troubleshooting
Sir in your discussion ,you have told that pipe is not generally used for heat transfer but in case of double pipe exchanger is used heat transfer phenomenon. So please help me !
Please make video on type of impeller of fan
Bro boiler superheater ko drain krne par ek video bnao
Sir,
Very nice explained.
Sir, please make one video on Auxiliary air dampers operation of wind box
Because we are not getting thermography graph as per requirement in standard condition..
Our plant 210 mw Nasik.( Lmw)
How to keep their position?
Is there any Standard operating procedures? If yes please make vdo .
Thank you sir..
Sir boiler tube material ke upr video bnao❤
In tube case in fire tube which u consider id or od for heating surface
Helo sir .please make to one video how many type of exchanger
How to check template in drawing
Key diffrence
Pipe shape is always round.
Tubes shape, Round, square, Rectangular
Is condensate happening in steam drum of boiler...
As per you video
Difference between pipe and tune
What about 14" pipe how is .
Is it same?
If schedule change out diameter naver change. Is it?
At 6:30 Flow=Area×Velocity
Hello sir ji pipe ka Outer diameter hamesa same hota hai(example 2" Ka pipe ,agar alag alag Sedule ka ho to sirf internal diameter change hota hai OD fix rahata hai)
How can attanted interview valve technician please
Sir.. Please make video on calculating heating surface and which are the zones which we include to calculate heating surface area..
Sure dear
Pipe OD is same for all schedule if Schedule increases from 10 to 80 then ID will decrease and wall thinkness will increase
Pl see Is 3589. Pipes are also specified by OD
Sir bowl mill performance pe koi vedio banaye
Sure dear
Ist view
Thanks
sir,
please AVGF ka ek simple video banaiye, mai pehele bhi upko request kiya tha but up bole the bad me karenge but banaye nhi..
Bna dunga dear thoda time lag skta h
sir boiler water treatment or boiler chamical k bare me ek video bnana plz
Dear I have already uploaded, please check my playlist of DMP
We have cooling tower COC -9. so we take 600 m3 as blow down. We have to throw it to drain. Can u suggest how to reuse this water, reduce our water loss
Boiler me pani Ka sankulesan sir bataiye
Boiler efficiency nikalne ka video
Already uploaded
Check this link for further explanation @Mech_Is_Easy
Difference b/w Film Foil Sheet and Metal
ua-cam.com/video/1mM6fVG0qlc/v-deo.htmlsi=XQjUEtoqwAlYxcqL
Sir, please make a video n help.
How can we control LOI???
Condition is this, our mixing coal contain more than 60% les then -1. And super heater tubes are also week.
Please sir
Bro you messed up with number 2... Pipe ka sch brhne se uska id km ho ya zayada ho ga.. Agr sch change hone se OD change ho ga to baqi fittings kese design kro ge? Like flanges? Pipe is nominated by nominal dia not OdD nor ID
Rong masegges. Pipe ke should badne pr id pr frank padenga sir OD pr nhi padenga steady kijiye ritern
In which book mention as you describe
Pipe ko mean diameter se denote krte hai
Sir aap plz ek WhatsApp group ya telegram group banaiye
Pipe od not chenge only id chenge in case of schedule changes
Pipe ki OD fixed hoti hain
Tube se v to fluid flow karte hain..
DH-1 AND DH-2 KE DRAIN KAHA SE LIYE JATE HAI AUR KYU
Pipes are denoted by nominal diameter or NPS, not by its ID
I think this video should be in 2 minutes.😅
Pipe ka od fix hota hai
Sir woh FLUUD nahi FLUID hh
Pipe OD vs Sch explained is not correct...
For the same pipe size (NPS), pipe ID varies with pipe schedule.
Please delete this video and come back with more knowledge ... Don't let anyone miss guide
Wrong information about Pipe and pipe represent with nominal size
Nice sir
Thanks sir