Very informative video sir🌷 ...agr ye information 2month phle milti to mere case study me bohot kaam aati...jis company me study krne gye the vha unko boiler k bare me kuch pta ni tha.... Apne sab clear krdiya but late.... 🥰No prblm
Kindly, avoid unnecessary lengthy explanation on very basics, for example in this video regarding metal expansion. If u drag unnecessarily purpose will loose it's sanctity.
Please can you make vedio on oil fuel supercritical boiler process or flow daigram because I have seen in supercritical boiler have no steam drum so I want to know how to steam formation in supercritical boiler without steam drum?
Sir ji expansion loop apne yahan vertical dikhaye hai lekin bahut jagah horizontal rehta hai... Toh iss case me steam trap ka efficient functioning toh nahi hoga
Dear jaise hi bend ke pass steam first apna direction change karta h, ohi pr steam trap lga dia jata h, Q ki steam aur water ka velocity me thoda difference rhta h, Ha ap bol skte h vertical ke case me bahut easily nikal jata h, usko ap ek dam boiler ke najdik hi lga skte h, ya kahi vi complicated way h oha lgaya jata h,
Thank u so much... Mera puchneka yehi purpose tha ki ye U bend steam line me only for EXPANSION ke liye diya jata hai... Kyuki steam trap ap koi bhi jagah jaha direction change hota hai waha de sakte hai...yaha loop banta hai isliye yaha trap diya jata hai... Anyway, I like your videos.. Bahut hi easy way me ap power plant engineering ko samjhate hai
Sir, can you tell me please where I can install Differential pressure transmitter for measuring steam flow, how far it should be from condensate draining point???
Sir, my yonger brother is machnical engg working in CHP area in refinary domain and wants to change material handling line..... Any course you can suggest?
Sir, in the example you say that thermal linear expansion value in Kelvin, and you took ∆T in deg. Celsius. Buy it's okay? We use it like this? Or we need to convert all value in Kelvin.
Okay, I am saying that the value of thermal liner expansion, that webconsiderb10, that is in kelvin. So for both case it would be same?@@tauqeerahmadsiddiqui2315
This is mainly for expansion Every metl has different linear cofficient of expension ..like ss and cs.. or apne kelvin ko celcius me change ku nhi kra?
thermal expansion value is in per Kelvin but temp dofference is in degree C ...so can we solve without conversion? What about it if we convert the unit from C to K?
Even if you convert “C” into “K” the temperature difference is going to be same. So i doesn’t matter if you take temperature difference in C or K or F they all are going to be same.
Very informative video sir🌷 ...agr ye information 2month phle milti to mere case study me bohot kaam aati...jis company me study krne gye the vha unko boiler k bare me kuch pta ni tha.... Apne sab clear krdiya but late.... 🥰No prblm
Superb explanation vicky kaushal ji
Thanks❤ ☺
Sir aap ki videos bohat informative hoti hain 👍👍 ❤ from 🇵🇰
intersting topic sir 🙏🙏🙏
Very unique topic
The best knowledge
I will try to watch at least one video daily ! Thank you sir ji
Very good information and useful
Thank u for informative videos
Good Information Sir
Excellent sir ji super 🙏👍👌
Sir very useful video thanks...
Very nyc sir
Helpful video sir
Good explanation
Jabardast questions.. 👌👌Thnx sir
U r just awesome... Very informative video.
Very good video sir
So informative proud of sir
Very nice..
Very good bhai
Thsnk you sir, very best daitals
Sir may Allah bless you.
Good Explanation Sir..
Good
Nice video
Nice Vdio
Thank u for the video
Amazing video 😍😍🎉🎉
Thanks
All the best sir
Nice sir
Safety valve me seat ko Nozzle kahte hai
Nice information 🙏
Very nice. After a long i found a channel with good stuff
Nice video sir....
Thanks dear
Nice speech sir
Thanks sir from 🇵🇰
Clear explanation sir..🙂🙂
Good 👍
Well explained 🙏
nice
Sir what about those expansion loop which is horizontal not vertical.
Why horizontal u bend is there?
👌👍
Thanks sir
Super sir
Boiler circulating pump par bhi video banaye
Low pressure boiler me after prs station ke bad steam line me lga sakte hai kya sir
Thank you sir
👍👍👍
Top support expansion se related kuch information video send kre
Sure
Please make a video on hydraulic couplings used in ID fan, BFP.
Sure very soon I'll provide
Sir, coficent m temp Kelvin m h or dt ⁰c m hai pls clear..ya ese hi niklega.
Kindly, avoid unnecessary lengthy explanation on very basics, for example in this video regarding metal expansion. If u drag unnecessarily purpose will loose it's sanctity.
?
We can use expansion below also right ?
Vvvvv
Correct
@@shaikhashabalamgulab99ikokķķokbibùkķkooib4hj😅😅😅ib😅😅bbbbbb9bjjj😊😊😊😊😊😊😊😊k😊😊9 ki😊
Hi sir steam strac work kese karta hai uspe video
Sure dear
Sir once through boiler per bhi video banaye
Sure dear very soon I'll make
Flow me khuch change aaga kya sir
Dear ne afbc boiler which type of steam dry or saturated?
Please
Cooling tower gear box Amrillo company checks ur gear ratio per video bnyia kindly
Kab bnyia ga??
Sir. why Water hardness Shown in caco3
Sir please make a video on steam consumption in plant..
Sir please make a video in diffrance between tube and pipe please sir
Mughey boiler emergency heldling ka video chahiye
Make a video about Centrifuge working principle.
Already video uploaded
Is it same for super critical boiler also. .?
Sir , home load aur ideal ke upar video banao
Sure dear
@@PowerPlantDiscussion thank you sir
Please can you make vedio on oil fuel supercritical boiler process or flow daigram because I have seen in supercritical boiler have no steam drum so I want to know how to steam formation in supercritical boiler without steam drum?
Please sir 🙏
Turbine flow meter bhi bina power ke on hota hai
Rcf ki exam hai. Paper ki tayari ke liye questions ki video banav sir.
Sir, please make up a video on IBR rules...!
Sure dear
Sir turbine mai load increase aur decrease ke upar video bnaye .
Sure dear
Why u beam in some place is upward or downward or horizontal
Sir ji expansion loop apne yahan vertical dikhaye hai lekin bahut jagah horizontal rehta hai... Toh iss case me steam trap ka efficient functioning toh nahi hoga
Dear jaise hi bend ke pass steam first apna direction change karta h, ohi pr steam trap lga dia jata h, Q ki steam aur water ka velocity me thoda difference rhta h, Ha ap bol skte h vertical ke case me bahut easily nikal jata h, usko ap ek dam boiler ke najdik hi lga skte h, ya kahi vi complicated way h oha lgaya jata h,
Thank u so much... Mera puchneka yehi purpose tha ki ye U bend steam line me only for EXPANSION ke liye diya jata hai... Kyuki steam trap ap koi bhi jagah jaha direction change hota hai waha de sakte hai...yaha loop banta hai isliye yaha trap diya jata hai... Anyway, I like your videos.. Bahut hi easy way me ap power plant engineering ko samjhate hai
Sir V1,V2=to P1,P2 par vedio banayiye.
Can u plz describe, why u bend proving in high pressure flare line?
Sir please explain about windbox 🙏
Sir Why is bypass steam line provided in the boiler through the main steam line.?
FD fan ID fan lik test kyon Liya jata hai?
Sir, can you tell me please where I can install Differential pressure transmitter for measuring steam flow, how far it should be from condensate draining point???
It should be within 15M to turbine inlet flange.
Sir, my yonger brother is machnical engg working in CHP area in refinary domain and wants to change material handling line.....
Any course you can suggest?
NPTI is best if he want to work in power plant
Sir, aap ne alfa ka value 9-15*10^-6/Kelvin pe bataye. Aur ∆T ka value °C pe liye. Convert nahi kiye ( °C to °K )
Dear this can be writing as /K, /°C, /°F
If you convert T1&T2 in K, °C or °F then their difference is always same.
@@PowerPlantDiscussion difference is always same for C and K not for F because in F , 5/9 factor comes 🙂
Sir please make vedio like Aqc boiler (whrb) with preheater boiler
Sure dear
Sir, in the example you say that thermal linear expansion value in Kelvin, and you took ∆T in deg. Celsius.
Buy it's okay?
We use it like this?
Or we need to convert all value in Kelvin.
Okay, I am saying that the value of thermal liner expansion, that webconsiderb10, that is in kelvin.
So for both case it would be same?@@tauqeerahmadsiddiqui2315
Dear this can be writing as /K, /°C, /°F
If you convert T1&T2 in K, °C or °F then their difference is always same.
@@PowerPlantDiscussion okay, I will do and check...thank you
Sir what r the reasons steam pipe line always protect with sheet plates?!
This is mainly for expansion
Every metl has different linear cofficient of expension ..like ss and cs.. or apne kelvin ko celcius me change ku nhi kra?
Kelvin aur °C ka ∆T same hi hoga
@@PowerPlantDiscussion bcz 1 digreecelcius is eqsul to 273k
@@neerajpokhriyal7958 add 273 in initial and final temperature then find ∆T
What is steam density at 200 degrees
Sir,
Please make one video for BOE exam IMP questions and answers.
Sir, What about /K
Dear this can be writing as /K, /°C, /°F
If you convert T1&T2 in K, °C or °F then their difference is always same.
explain expansion bellow types and why use in pipe line؟
Sir why steam density is less than water density explain????
Some tym it's has horizontal arrangements why it like that
For compensating thermal strain in piping
Sir celculeton samjh nhi ai kai bar dekhne par bhi
How much pressure drop in steam and water line bend please make a video please
Moc of steam line
Steam line main ye U band vertically ziyada behtar hain k horizontal?
Horizontal
Alloy steel kaya hota hai bhai, steel to khud he alloy hai.
If thermal liner expansion is in K so is it required to convert C of Delta T in K or not?
Steam line ki moc kya hoti hai
Thank you so much sir.... But in my company the U bend is in horizontal way not in vertical... So it's same working or little bit different
Same function but vertical is very effective to condensate removal, horizontal bend provided due to inconvenience in way,
thermal expansion value is in per Kelvin but temp dofference is in degree C ...so can we solve without conversion? What about it if we convert the unit from C to K?
Even if you convert “C” into “K” the temperature difference is going to be same. So i doesn’t matter if you take temperature difference in C or K or F they all are going to be same.
@@usamarasheed4349 oh,got it.
App dilip patel sir ko jante ho sir
Raigarh sky vale
Ha