Testing 3 samples with Aqua Regia and stannous chloride to find gold.

Поділитися
Вставка
  • Опубліковано 29 січ 2023
  • Testing 3 samples with Aqua Regia and stannous chloride to find gold.
  • Розваги

КОМЕНТАРІ • 42

  • @shucksful
    @shucksful 2 місяці тому +1

    Great video, and really funny episode with you cracking on yourself throughout the whole thing. lol! 😂 Thanks for the knowledge.

  • @kaningraja2145
    @kaningraja2145 Рік тому +1

    Love you so much❤❤

  • @AdriaMohler
    @AdriaMohler Рік тому +1

    Can’t wait to see the next video to see how much gold is in the rocks.

  • @myadventure7069
    @myadventure7069 Рік тому +1

    Good I like to see more videos 😊

  • @OnsloVest
    @OnsloVest Рік тому +1

    Much enjoyed.

  • @TrickyDickyP
    @TrickyDickyP 10 місяців тому +1

    Nice one Lars.. 😊

  • @anella1776
    @anella1776 Рік тому +1

    Haha haha... Yup you are professional 😊😀😀😀

  • @idontknowmyfirstname69
    @idontknowmyfirstname69 10 місяців тому +1

    Stannous also goes brownish if theres an excess of sulfur dioxide dissolved in the solution

  • @bully9917
    @bully9917 Рік тому +1

    Great video ! Keep it up. Question: Does the HCL remove all the sulfides (same as roasting), or should you roast the sample prior to adding chemicals ?

    • @thisoldminewithlars5324
      @thisoldminewithlars5324  Рік тому +4

      It is my understanding that the sulphur will produce hydrogen sulfide gas and chlorine gas as the sulfur takes hydrogen from the HCl. It also contaminates the solution with whatever the sulfur was originally bonded with. If you have a lot of sulfides, roasting in advanced would be a good idea.

  • @yahshuasaves7478
    @yahshuasaves7478 Рік тому +2

    Great video! I did also the aqua regia mix with the crushed rocks. I used HCL & Nitric acid, but I'm noticing when I use urea to kill the Nitric; the urea is not dissolving 100%. Half still floating at the top. Not sure to heat the mix with the urea in it?? Any suggestions?

    • @thisoldminewithlars5324
      @thisoldminewithlars5324  Рік тому +1

      I now dissolve the urea with water before adding it to the AR. This way you don’t get undissolved urea in the mix. You can also heat the AR to help dissolve the urea but you need to cool it down before precipitating.

    • @yahshuasaves7478
      @yahshuasaves7478 Рік тому

      @@thisoldminewithlars5324 Got it! Thank you!

  • @Amulek293
    @Amulek293 8 місяців тому +1

    Shouldn’t the solution containing base metals dissolved from the muriatic acid be rinsed out before using aqua regia to put any gold in solution in what’s left? Thanks!

  • @newmexicogold2234
    @newmexicogold2234 Рік тому +1

    Kool......

  • @chapwetumelo9601
    @chapwetumelo9601 Рік тому +1

    Thanks for the demo. I once did this experiment. I added stanous chloride the aqua rigia rich mixture , the change of colour immediately happened. When I took the same sample for an XRF assessment, I was told there was no gold. How can this be Sir?

    • @thisoldminewithlars5324
      @thisoldminewithlars5324  Рік тому +1

      If the nitric acid is not completely neutralized, the stanous test will give you a false positive. Also if there is palladium in the test sample it could look like a strong positive for gold. Other metals can also contaminate the AR and give odd results.

  • @virgisst761
    @virgisst761 10 місяців тому +1

    Smb not always preciptates Au from AR. Especialy when urea is used to kill nitric

  • @zohirkamel6777
    @zohirkamel6777 9 місяців тому +1

    I did the same experiment on a sample. The result was strange. The color of the sample changes to black gradually and takes about half an hour. Does this mean there is gold in the sample?

    • @thisoldminewithlars5324
      @thisoldminewithlars5324  9 місяців тому +1

      It probably indicates that you have other metals or PMGs in solution. Platinum, palladium or iron and copper. I have had this happen as well. Sometimes you just can’t get around it without doing more processing.

  • @xenaguy01
    @xenaguy01 10 місяців тому +1

    16:00 Did you deNOx this combo solution? Looks like not.

  • @u2ooberboober
    @u2ooberboober 10 місяців тому +1

    You ever sell raw or samples? I’d like to try this…

    • @thisoldminewithlars5324
      @thisoldminewithlars5324  10 місяців тому

      The ore I have so far is pretty poor quality. I would be ashamed to sell it.

  • @MyScreenNameIsTroubledOne
    @MyScreenNameIsTroubledOne 9 місяців тому +1

    Silver chloride maybe? Silver reacts with chlorine right?

  • @rezmyhand461
    @rezmyhand461 Рік тому +1

    Sir why you immediately using smb to get precipitate ? Why not denox that solution with urea first?

    • @thisoldminewithlars5324
      @thisoldminewithlars5324  Рік тому

      I got a bit ahead of myself but at 13:05 I re-tested with denoxing.

    • @rezmyhand461
      @rezmyhand461 Рік тому

      ​​​@@thisoldminewithlars5324 I mean when you mix all solution in one beaker and then at 15:40 I little bit confuse, cause you didn't do the denox with urea, but use smb to get precipitate,,, is it we can get the gold without denox the aqua regia with urea?

    • @thisoldminewithlars5324
      @thisoldminewithlars5324  Рік тому

      I don’t use an excess of nitric in the tests so the denoting is minimal. I usually re-treat the ore after I do a test to get all the gold. Denoxing is critical if you have a lot of nitric left over. Other than denoxing, you will need to use extra SMB to precipitate.

  • @alllove1754
    @alllove1754 10 місяців тому +1

    Platinum makes a yellow salt

  • @coinstipatedtexan83
    @coinstipatedtexan83 10 місяців тому +1

    can't you just cut filter paper into strips, dip the strips in the solution and drop the stanous chloride to the strip. Much less waste than either procedure you chose

    • @thisoldminewithlars5324
      @thisoldminewithlars5324  10 місяців тому +1

      Yes, at times I do use them. When refining gold at higher concentrations the change on the paper strip is instantly noticeable, but the paper strip method is difficult for me to read with low gold concentrations. In the spot plate method, any positive test is not discarded. I save all the little squirts of positive tests, than once I accumulate enough I redissolve in AR and precipitate with SMB or ferrous sulfate.

  • @coinstipatedtexan83
    @coinstipatedtexan83 10 місяців тому +1

    respirators don't help with chlorine gas

  • @user-yt9sw6vl7c
    @user-yt9sw6vl7c 11 місяців тому

    Перевод