Vacuum Circuit Breaker Nameplate Details | Explained

Поділитися
Вставка
  • Опубліковано 31 січ 2025

КОМЕНТАРІ • 36

  • @sisir22
    @sisir22 Рік тому +1

    very nice explanations sir

    • @GauravJ
      @GauravJ  Рік тому

      Thanks and welcome

  • @prabhakaranr3594
    @prabhakaranr3594 4 роки тому +2

    Nice explanation

  • @devendraparihar1253
    @devendraparihar1253 4 роки тому +1

    Good explanation sir , thanks

  • @ratnesh12100
    @ratnesh12100 4 роки тому +2

    Please make video on automatic fault locator AFL .. By the way nice videos..

  • @akashpatil9341
    @akashpatil9341 4 роки тому +1

    Nice video thanks you so much for knowledge sharing 🙏

  • @VigneshVicky-hm7kc
    @VigneshVicky-hm7kc 4 роки тому

    Useful information! Kindly elaborate about DC component. I'm not clear about it,how it occurs & when? Pls guide us

  • @surendrakverma555
    @surendrakverma555 4 роки тому +1

    Excellent. Thanks

  • @todayshot...9827
    @todayshot...9827 Місяць тому

    110kv/220kv you have spelled the words, at the time of explaining the shunt coil in this video (6:48)

  • @shemphangnongsiej2168
    @shemphangnongsiej2168 3 роки тому

    nice video sir, thank you very much my doubt on the duty cycle is cleared. sir, can you please define or give some reference or share some light on how to arrive the ALTITUDE CORRECTION FACTOR of the BIL of equipment above 1000m level?

  • @niluv9019
    @niluv9019 8 місяців тому +1

    nice

  • @donberg01
    @donberg01 4 роки тому

    What about load break switches? There are occasions when you have to open a circuit under load, please explain?

  • @Eng853
    @Eng853 4 роки тому

    Hi sir, Please make a video of ferro resonance and their effects in instrument transformer

  • @raj....8240
    @raj....8240 2 роки тому

    Relay trip coil operation on
    Ac or dc
    Ya both reply sir🤩🤩🤩😍😍🛑🛑

  • @balachandra7475
    @balachandra7475 4 роки тому

    Please make a video safe plus type rmu &vcb

  • @devendraparihar1253
    @devendraparihar1253 4 роки тому

    Make video for LA , wave trap also

  • @electricalhacks1795
    @electricalhacks1795 4 роки тому

    I request you please make a video on "power system stability enhancement by simultaneous AC-DC power transmission"

  • @Sanju-hr3cr
    @Sanju-hr3cr 4 роки тому

    Pls make videos on VCB DRAWINGS.
    CIRCUIT BREAKER CONTROL WIRING WORK.

  • @EnthusiasticRedCar-xy4yg
    @EnthusiasticRedCar-xy4yg 10 місяців тому

    Sir, want to know about why Nitrogen gas usage in PCVCB Bussings.tnxx🙏Jai hind🇮🇳

  • @rahulmudavath5923
    @rahulmudavath5923 2 роки тому

    Sir, why CB rating is less than transformer full load current.

  • @jaherayo6978
    @jaherayo6978 4 роки тому

    sir how we know the rated volted / current from normal volt/ current ,plz explain.
    Sir plz make a video on interlocking between isolator and vcb

  • @sudheersubairkutty1633
    @sudheersubairkutty1633 3 роки тому

    Please note that for breaker operating sequence is mentioned in IEC-62271-100, not in IEC-62271-1 which you mentioned.

    • @GauravJ
      @GauravJ  3 роки тому

      Operating sequence is also part of IEC 62271-1

  • @realislamicguidance2375
    @realislamicguidance2375 3 роки тому

    CB having Higher DC component is better or CB having lower DC component is better?

  • @dkverma67
    @dkverma67 4 роки тому

    What's Ferro Resonance?
    Please explain

  • @chinnakarlapraveen9966
    @chinnakarlapraveen9966 4 роки тому

    Why in transmission substations 400kV is not directly stepped down to 33kV & why they do it in 3 steps as 400/132kV then 132/66kV and then 66/33kV?

  • @ratnesh12100
    @ratnesh12100 4 роки тому

    At 6.47 min,
    Generally it is either 110vDC Or 220 vAC instead of 110 kv and 220kv

    • @GauravJ
      @GauravJ  4 роки тому +1

      Oh sorry.. did i say kV.. it’s volt actually

  • @magnamind
    @magnamind 2 роки тому

    Had some clarification on IEC62271-100

  • @chinnakarlapraveen9966
    @chinnakarlapraveen9966 4 роки тому

    Sir make a video on why 50Hz is used in India, where as 60Hz in usa

  • @chinnakarlapraveen9966
    @chinnakarlapraveen9966 4 роки тому +1

    Hi sir

  • @narenderreddy7305
    @narenderreddy7305 Рік тому

    Ok

  • @RB-xv4si
    @RB-xv4si Рік тому

    I think you are confused. In a three phase system, two poles is single phase, not two phase.

  • @magnamind
    @magnamind 2 роки тому

    Hi