Fire Detection and Alarm System

Поділитися
Вставка
  • Опубліковано 17 жов 2024

КОМЕНТАРІ • 175

  • @bobcasseus7381
    @bobcasseus7381 4 роки тому +7

    good job Mister Junrey Eguna i really like and appreciate the way you make people understand how fire detection and fire alarm system work .

    • @junreyeguna
      @junreyeguna  4 роки тому

      I appreciate for the comment sir. Thank you so much

  • @avallanchefire5059
    @avallanchefire5059 4 роки тому +11

    This is very easy and understandable..the technician must explain when installing and connecting

  • @vishnumohan4071
    @vishnumohan4071 3 роки тому +2

    Your presentation are Really help me to understand FACP. Only one dout while you are integrated the hooters based on zones all the hooters are blinking may confuses the zone . Can you kindly explain

  • @irenerosas4315
    @irenerosas4315 3 місяці тому

    just one question, if we perform a test in the zone 1, the light or siren in the zone 1 have to work ?, and wy the rest of the sirens (zone 2, 3 and 4) work also?, at really I don´t know

    • @junreyeguna
      @junreyeguna  3 місяці тому +1

      You don't get confuse which zone has fire since control panel will show which zone sensor has been activated which would help the paging system operator to guide the occupants which zone/area should be avoided when evacuating. But of course I repeat, all sounders should be activated so that all occupants would evacuate.

    • @irenerosas4315
      @irenerosas4315 3 місяці тому

      @@junreyeguna is true yoy have reason, is necessary activate all sensors to know that exist a emergency, thanks a lot bro

  • @bobcasseus7381
    @bobcasseus7381 4 роки тому +2

    i need more video of detection and fire alarm system from you i really like that field i am living in USA i work for a fire alarm company in New york city.

    • @junreyeguna
      @junreyeguna  4 роки тому

      I have already 6 more videos about FDAS and its components. God bless

  • @muhy9247
    @muhy9247 4 роки тому +8

    During testing you don't need to break the ARMAC glass , all you need to do just use the key to release and test .

  • @adegbolaabdulahi9495
    @adegbolaabdulahi9495 Рік тому +1

    Well understood, thanks for the effort put in place.

  • @mouadhvic5916
    @mouadhvic5916 16 днів тому

    question : Could i place the sounder alarm in the middle of the loop

  • @ahmedmohamed-z1i5s
    @ahmedmohamed-z1i5s Рік тому

    I want more of this valuable information and thank you for that

  • @satyamgollapalli6480
    @satyamgollapalli6480 3 роки тому +1

    So nice video Thank you sir.👍👍👍👌👌👌

  • @zian.2493
    @zian.2493 4 роки тому +1

    Malaking tulong po to for info bout fire safety..may updated price po b kau and specs n subok n mairerecomend?for upcoming videos nio po suggestion for more better result paki focus po sa detailed part Ng videos .

    • @junreyeguna
      @junreyeguna  4 роки тому +1

      Yes sir thank you for your suggestion. I'm planning to give more details in the inside of the control panel on my next video about FDAS

    • @lykamarieclairenemil7101
      @lykamarieclairenemil7101 3 роки тому

      sir pwede po ba duplex wire no. 18 gamitin ko

  • @abdallah.alammar
    @abdallah.alammar Рік тому

    I know that the wiring for fire alarm system should be one piece without cuts, is that true? and if yes how to wire it?

  • @chimavite82
    @chimavite82 4 місяці тому

    Good video, why is zone 2 red light flashing continuously even when there's no smoke or dust

    • @junreyeguna
      @junreyeguna  3 місяці тому

      It doesn't matter which zone (area) is on fire, all occupants must evacuate thus all sounders should be activated.

  • @dallysodyssey
    @dallysodyssey 2 роки тому

    Sir tanong ko lang po, pag ba magkakabit ng fdas ano po mga kailangan natin sa pag proseso na ng installation maliban sa mga equipments?

  • @ramildimaano3092
    @ramildimaano3092 2 роки тому

    ask lng bos bkt naka battery trobol p rin kht napalitan na ng bgo battery after mareset..mlimit tuloy tumunog ung warning nya..

  • @johndayms7244
    @johndayms7244 4 роки тому

    just want to ask practical question. If one smoke detector in zone1 in fire alarm status and the Fire alarm panel activated to Fire alarm with sounder is being activated, my question is does other smoke detector in the same zone (zone1) would still alarm (knowing that the zone circuit in question is in Alarm mode already)assuming the fire reaches to other adjacent smoke detector? Granting the fire alarm was not reset in the panel and the smoke or heat still in alarm mode and only silenced at the Fire alarm Panel. Why or Why not? thank you.

    • @junreyeguna
      @junreyeguna  4 роки тому +2

      Yes sir when 1 of the detectors in the zone (e.g. Zone 1) has sent the signal to the control panel (zone indicator will show alarm in zone 1 meaning the fire is in zone 1), the panel would activate all the sounders at the same time. When the fire reaches the other detectors on the same zone, those detectors would still give signals to the control panel though indicator in zone 1 is already activated. You would see the indicator light of the detector itself turns from blinking to steady red when it detects fire. When fire reaches to other zone, the indicator light of the fire detector once again would change from blinking red to steady meaning the fire reaches that device and at the same time the indicator light of the control panel will also be activated meaning the fire reaches that zone.

    • @johndayms7244
      @johndayms7244 4 роки тому

      @@junreyeguna maximum of how many detectors can one zone with detectors could still detect fire assuming that some detectors already in fire alarm mode. And also how much voltage drops does one smoke detector consumed in alarm mode? What is the minimum voltage in an IDC/zone circuit that could still send fire alarm signal to panel to activate the alarm.

    • @junreyeguna
      @junreyeguna  4 роки тому

      Sir the maximum number of detectors in a zone depends on the model of the control panel. In the video, the control panel can hold up to 4 detectors in every zone without affecting its efficiency

    • @johndayms7244
      @johndayms7244 4 роки тому

      @@junreyeguna in a conventional FACP, how to minimize false alarm signals from idc devices?

    • @junreyeguna
      @junreyeguna  4 роки тому

      usually false alarm is caused by dusty/moist environment (in cases of smoke detectors), wrong choice of cable, loose termination, wrong or faulty resistor or maybe signaling wires came across with your AC source so these are some of the things we need to avoid when wiring our initiators.

  • @yongyong4676
    @yongyong4676 2 роки тому

    Sir ask ko lang po. Convensional f.a. ang sounder connection po ba ay pwde isang wire conection lang +?

  • @railzabrano965
    @railzabrano965 2 роки тому

    master ilan po ang pwedi mong i kabit sa zone 1 po pwedi po umabot ng Sampong Smoke Detector ?

  • @khirbie.cute18
    @khirbie.cute18 4 роки тому +1

    Sir pwede po mag asked lang po..about po sa pag testing niyo sa smoke detector or heat detector noong nag testing na po kayo bkit po ung strobelight niyo po nag alarm lahat hindi po doon lang sa designated area lang po ung mag alarm..

    • @junreyeguna
      @junreyeguna  4 роки тому +1

      Yes sir normal po tlaga na lahat ng strobe light ay mag alarm kasi po ang purpose ng FDAS ay para ma-aware lahat ng occupants ng building to evacuate kahit wala pa sa kanilang zone ang sunog. Makikita nman po sa indicator light ng mismong control panel sir ang location or zone ng naka activate ng detector.

  • @rodrigojosecamanong207
    @rodrigojosecamanong207 3 роки тому

    Hello sir goodday po sa inyo tanong kulang po kung wiring ng firemans teliphone jack naka paralel lang ba sya sa loop ng fdas or may sarili syang wire at kung may sarili po syang wire anung wire po recomended tungkol sa firemans telephone jack.

  • @dx-hd2th
    @dx-hd2th 3 роки тому

    Master Yung strobe light ba pwede bayan e terminate sa sounder,? Salamat

  • @chewyyo3383
    @chewyyo3383 Рік тому

    Where can you buy these? I need practice in real life !

  • @umarfarook6109
    @umarfarook6109 2 роки тому

    I have doubt.... Why the 4 horn strobe get activated when any one of the detector gets detected....
    Is that 4 horn is a circuit or what..?

    • @junreyeguna
      @junreyeguna  Рік тому

      Yes sir, if any of the sensors detects fire, all sounders should be activated so that all occupants of the buildings should be aware that there is an on-going fire so that they can immediately evacuate. Say for example, there is a fire in the 3rd floor of the building, all building occupants should be aware and evacuate and not just those who are in the 3rd floor or whichever zone being involved.

  • @NBElectricalTutorials
    @NBElectricalTutorials 4 роки тому +1

    Sir, thank you for sharing your ideas . more video .

    • @junreyeguna
      @junreyeguna  4 роки тому +1

      Yes sir, soon if time permits. Thank you so much

    • @junreyeguna
      @junreyeguna  4 роки тому +1

      May be you are interested sir, I already have uploaded more videos about FDAS components and testing. Thank you

  • @arjayjerez3163
    @arjayjerez3163 Рік тому

    hi, do you have picture layout of your control panel box?

  • @riccbb609
    @riccbb609 4 роки тому +1

    Sir gusto ko po matuto about FDAS please make more videos about this thank you and more power godbless👍

    • @junreyeguna
      @junreyeguna  4 роки тому

      salamat po. i'll be posting related videos once it will be made available.

    • @cromselectrical2659
      @cromselectrical2659 4 роки тому

      Addressable po ba yn boss?

    • @junreyeguna
      @junreyeguna  4 роки тому

      @@cromselectrical2659 conventional lng po yan sir.

    • @andyguieb1898
      @andyguieb1898 4 роки тому

      mas maganda master kung related sa ncII.. pls.. ty..
      kailangan ko kasi fdas at cctv..

  • @Hayder.J.H
    @Hayder.J.H 3 роки тому

    Great 👍👍👌👍👌 good luck 🤞

  • @roybenjamin9355
    @roybenjamin9355 3 роки тому

    .parepareho lang ba ang instalation..kahit iba iba ang ang brand ng panel..kase po may 3phase po..tulad ng aseware..

    • @junreyeguna
      @junreyeguna  3 роки тому

      Magdepende po yan sa brand at model sir. Refer nlng po tayo niyan sa kanyang installation/user's manual na kasama sa unit po.

  • @sawmoshay-b6b
    @sawmoshay-b6b 22 дні тому

    Please Tell Me Place In Myanmar.
    Want To Buy Smoke Detector

  • @engnnosha
    @engnnosha Місяць тому

    مرحبا هل من الممكن ان اربط الاجراس واحدة مع اخرى في حال كونها اكثر من واحدة في نفس الzoon

  • @mohamedrihan3619
    @mohamedrihan3619 2 роки тому

    Thank you sir good explanation..
    And amazing..

  • @chesterbenington3480
    @chesterbenington3480 4 роки тому +3

    Salamat master👍.good bless

  • @daveduyaggan4123
    @daveduyaggan4123 3 роки тому

    Helo sir,, may i ask if where to put the diodes,?, same brand asenware..

  • @ghinggho
    @ghinggho 4 роки тому

    Sir, ilang ohms po ba ng resistors ang kailangan para dyan.??? yung standard na po na ohms na kailangan..thnx

    • @rhivyn1
      @rhivyn1 4 роки тому

      24k ohms para sa conventional..47k naman para sa addressable..

  • @mohammedhse4451
    @mohammedhse4451 2 місяці тому

    Amazing ❤ Thank you

  • @HiềnHuỳnhQuang-s5e
    @HiềnHuỳnhQuang-s5e Рік тому

    so easy to understand thanks

  • @jbartsjbarts7504
    @jbartsjbarts7504 2 роки тому

    is the heat detector reusable?

  • @humbertojoaomanuellourenco6356
    @humbertojoaomanuellourenco6356 7 місяців тому

    Amazing 😎🤗

  • @darnelcabillo1551
    @darnelcabillo1551 3 роки тому

    Notifier Ang brand na gamit Namin sa Robinson sir tyaka yung setup po Namin sa manual pull down at smoke detector magkaibang home run maski pareho po syang addressable sir nagkaka trouble sya kaya ginawa ko na lagyan nalang sya ng sariling home run yun naging ok na pati sa module nya at tyaka sa panel Namin..

  • @jomarksendrejas8314
    @jomarksendrejas8314 2 роки тому

    Ok lng po pala ilagay diretso ang resistor sa terminal ng facp?

    • @jayahldanac9998
      @jayahldanac9998 4 місяці тому

      Pwede nmn sir pero di matitrigger ang facp if ever may lose connection or defect ang devices, much better maglagay ng resistor sa dulo ng line pra maiwasan ang mga to.. EOL (end of line)

  • @MOHAMMADJAVED-jb4pk
    @MOHAMMADJAVED-jb4pk 3 роки тому +1

    Is this FACP Asnware brand?

  • @jovenjamero9742
    @jovenjamero9742 4 роки тому +3

    hi sir. can I use this video as a reference for teaching my students

    • @junreyeguna
      @junreyeguna  4 роки тому

      Yes sir you may use the video if for educational purposes. Subscription also to my channel is highly appreciated. God bless

    • @darnelcabillo1551
      @darnelcabillo1551 3 роки тому

      NC2 nalang po kulang sakin sir.. naka experience ako mag FDAS dito sa Robinson mall at hangang Ngayon sir nagamay kona sya at natoto narin ako tungkol sa data wiring at termination Kong paano ko sya pinag aaralang mabuti hehehe salamat pala sa supervisor ko na napaka bait at handa syang magturo para matutonan Ang FDAS oh auxillary hehehe god bless po sir Ricky. At Sayo din sir may mga nakuha parin akong lesson Sayo hehe

    • @domingomagcosta7740
      @domingomagcosta7740 2 роки тому

      Sir how many device installed in zone 1 or maximum device installed in zone 1

  • @raquelmien5324
    @raquelmien5324 4 роки тому +1

    NIce one sir.. nag subscribed po ako..

  • @dg7799
    @dg7799 3 роки тому

    Is a sprinklerbell used as output?!

  • @md.abdurrazzak8746
    @md.abdurrazzak8746 3 роки тому

    great vedeo

  • @juliejoyla6105
    @juliejoyla6105 6 місяців тому

    Pwedi po Bayan sa line to line connection? Ask ko Lang kung pwedi

  • @hassanmeligy9958
    @hassanmeligy9958 4 роки тому

    Sir, is that a conventional or addressable system and why ? ... Many thanks in advance

    • @junreyeguna
      @junreyeguna  4 роки тому +2

      the video uses a conventional fdas

    • @vincentemoh1959
      @vincentemoh1959 Рік тому +1

      Why were there no end of line resistors?

  • @abubakersiddig7036
    @abubakersiddig7036 2 роки тому

    very nice job

  • @gelliebethsumaria3789
    @gelliebethsumaria3789 3 роки тому +1

    thank you Sir.Godbless

  • @elsiebonilla7445
    @elsiebonilla7445 3 роки тому

    Awesome video!! Thank you

    • @junreyeguna
      @junreyeguna  3 роки тому

      Glad you liked it, thank you so much.

  • @selcukbayraktarphd
    @selcukbayraktarphd 2 роки тому

    without JBFA ? Direct to MCFA is okay?

  • @MgkyawKyaw-p3l
    @MgkyawKyaw-p3l 2 місяці тому

    Can we compound sound storbe?

  • @bryanangga793
    @bryanangga793 3 роки тому

    Sir pano po alisin ung fault relay na error sa goalstar na panel. Nag iingay po sya lagi e. Goal star 16 zone version 2

  • @গনিতশিখি-ঝ৭চ

    It would have been better to do the video with the camera. And it would be helpful to understand the connection by saying the name of each device.

  • @JoanNin
    @JoanNin 3 роки тому +1

    Fire Alarm Systems looks easy to wire. But how the people inside the building know with Zone is the one that triggers the system without being in front of the Panel

    • @vapour7
      @vapour7 3 роки тому +1

      It's for the fire department to know so they can see how to tackle the fire.

    • @junreyeguna
      @junreyeguna  3 роки тому

      another electrical auxiliary system a building should have is the cctv, telephone and the paging system sir.

  • @RRElectricals83
    @RRElectricals83 3 роки тому

    Sir smoke detector lagane ka price kitna h

  • @avallanchefire5059
    @avallanchefire5059 4 роки тому

    Is the cable being used a fire resistance cable

    • @junreyeguna
      @junreyeguna  4 роки тому

      During actual installation, cables should be a fire-resistant signaling cable but in the video, I just used the ordinary signaling wires for the demonstration.

  • @kashemshohankashemshohan3770
    @kashemshohankashemshohan3770 2 роки тому

    Dear sir,is it last point need 6.5k Resister

    • @royochola
      @royochola Рік тому

      Good question, I thought he would connect a 5.6k ohm resistor to the break glass device

  • @simpliciocamirino2271
    @simpliciocamirino2271 3 роки тому +1

    Salamat sa sharing bossing.

  • @jamiusurakat3129
    @jamiusurakat3129 4 роки тому

    Nice video, God bless you

  • @ArunKumar-qb5kf
    @ArunKumar-qb5kf 3 роки тому

    Bhai market kah h iski

  • @skytv6524
    @skytv6524 3 роки тому

    Sir anong brang yan fire alarm panel?

  • @railzabrano965
    @railzabrano965 2 роки тому

    at sa pag wring po master Pwedi po bang makapalit ang SD At Motion DETECtor PO
    \

  • @marcianojrlofranco6234
    @marcianojrlofranco6234 3 роки тому

    Bkt wlng resistor master pwd pala yun.

  • @kalaikavi-mo8gn
    @kalaikavi-mo8gn Місяць тому

    Thank you sir

  • @nilolacupanto8435
    @nilolacupanto8435 3 роки тому +1

    Hi sir gustu q poh sana kumuha ng nc2 sa tesda for EIM anu poh ang trial?

    • @junreyeguna
      @junreyeguna  3 роки тому

      Assessment package is written, interview and actual demonstration of lighting fixtures, outlets and cctv or fdas

  • @jamesdavid1976
    @jamesdavid1976 2 роки тому

    sir, gawa din po kayu video ng wiring diagram nyan,, thanks

  • @vairagijayesh
    @vairagijayesh 4 роки тому +1

    Thank you.. God bless🙏

  • @chagaarbellal4983
    @chagaarbellal4983 4 роки тому +1

    Big thanks bro

  • @umeshbk2979
    @umeshbk2979 2 роки тому

    sir will u translate in english it most important and helpfull thanks

  • @TEKSBLOG
    @TEKSBLOG 4 роки тому

    Nice galing naman master

  • @EngrKachi
    @EngrKachi 3 роки тому

    Nice

  • @md.gufranansari9672
    @md.gufranansari9672 4 роки тому

    What is the size of wire?

    • @junreyeguna
      @junreyeguna  4 роки тому +1

      for the AC source, it is advisable to use at least #16 AWG size of conductor while for the signaling devices conductors should be 0.5mm2 to 1.5mm2.

  • @tanatswamunashemazwi7274
    @tanatswamunashemazwi7274 11 днів тому

    U shud have brought th camera up close to the control board maan we cant see the details

  • @AnaniyaAlelign
    @AnaniyaAlelign 4 місяці тому

    Nice Work But

  • @fredtechelect2932
    @fredtechelect2932 3 роки тому

    Pano po connection kung merong room indicator,?

  • @mulastafa
    @mulastafa 2 роки тому

    Beautiful

  • @oscar27ization
    @oscar27ization Рік тому

    I never knew how easy fore alarm was😂

  • @ManiMani-qb3rk
    @ManiMani-qb3rk 2 роки тому

    Thank you sir 😊

  • @طارق-ث7س9س
    @طارق-ث7س9س 2 роки тому

    good

  • @edstelrodelas7453
    @edstelrodelas7453 3 роки тому

    Eol sir meron ba resistor.

  • @dataengineering9921
    @dataengineering9921 Рік тому

    السلام علیکم bahi jan

  • @yhanieevangelista5302
    @yhanieevangelista5302 Рік тому

    Bkit music dapat ng sasalita ung maririnig

  • @rolandlagramada9165
    @rolandlagramada9165 4 роки тому

    Sir yong termination don sa panel gusto ko sana makita sang terminal mo po nilagay thanks po

    • @junreyeguna
      @junreyeguna  4 роки тому

      Sir I have uploaded more videos already about control panel termination and so as with control panel circuit boards.

  • @dataengineering9921
    @dataengineering9921 Рік тому

    السلام علیکم g

  • @thiyageshv4844
    @thiyageshv4844 4 роки тому

    Plz show the connection of wire in panel in zoom mode.

    • @junreyeguna
      @junreyeguna  4 роки тому +1

      ua-cam.com/video/aNEgwVbA9nU/v-deo.html

  • @roybenjamin9355
    @roybenjamin9355 3 роки тому

    .sir saan ung bell nya jan?

    • @junreyeguna
      @junreyeguna  3 роки тому

      Yung apat po na kulay pula sa taas ng control panel. Horn with Strobe light na po siya

  • @dedikurniawan6094
    @dedikurniawan6094 3 роки тому

    Bang bisa belajar GK ya? Or.. ada no TLP bang?

  • @kidlattv5472
    @kidlattv5472 3 роки тому +1

    Anlayo sir dapat ilapit mo ung camera mo

    • @junreyeguna
      @junreyeguna  3 роки тому

      one of my first video po kasi to sir during pandemic kaya di pa ganun ka ayos ang pagkkuha ng video.

  • @greenmcdermote2775
    @greenmcdermote2775 3 роки тому

    EOL mo master bakit walang Resistor

    • @junreyeguna
      @junreyeguna  3 роки тому

      naka fix na po siya sa device sir

  • @andyguieb1898
    @andyguieb1898 4 роки тому

    ganyan po baang gagawin sa nc2..? EIM.. Maraming salamat master..

    • @junreyeguna
      @junreyeguna  4 роки тому

      Isa lng po sa kelangang matutunan ng EIM NC II

    • @andyguieb1898
      @andyguieb1898 4 роки тому +1

      @@junreyeguna may ncII na kasi ako nung 2012.. naexpired.. wala p dati fire detection and alarm.. kukuha ulit ako ng assesment.. dito ko na lang matutunan ang fire detection and alarm para sa assesment..

    • @junreyeguna
      @junreyeguna  3 роки тому +1

      @@andyguieb1898 yes sir CCTV installation, Door Access Control at FDAS installation lng nman po ang naidagdag.

    • @andyguieb1898
      @andyguieb1898 3 роки тому

      @@junreyeguna salamat master..

  • @babuollachery6333
    @babuollachery6333 4 роки тому

    Easy testing

  • @kuyamojeck7880
    @kuyamojeck7880 2 роки тому

    Boss paturo naman ako

  • @alvenparanguay8721
    @alvenparanguay8721 4 роки тому

    saan school po pwedi mg aral ng Fdas

    • @junreyeguna
      @junreyeguna  4 роки тому

      Any technical school po sir na nag ooffer ng EIM NC II or sa TESDA training center na malapit sa inyo.

  • @annaiagrofarms8072
    @annaiagrofarms8072 4 роки тому

    Thank you sir ...

  • @corbindallas831
    @corbindallas831 3 роки тому

    uh oh strobes aren't synced...

  • @TheTyltyltyltyl
    @TheTyltyltyltyl 3 роки тому +1

    really use a box grommet on your main panel rookie

  • @roelaquino3079
    @roelaquino3079 4 роки тому +1

    Sir! Good eve., ok lng ba subscribe ako. Vloger npla kayo

  • @nareshparmarrameshbhaiparm87
    @nareshparmarrameshbhaiparm87 3 роки тому

    Nac fault kese nikale

  • @florentinoulnagan6441
    @florentinoulnagan6441 3 роки тому

    Mas maganda kung close up ung video..