SCS - A Minute with Miranda - Testing an ESD Floor

Поділитися
Вставка
  • Опубліковано 31 тра 2024
  • Welcome back to "A Minute with Miranda." This week we will be discussing how to test the point-to-point resistance (Rtt) and the resistance-to-ground (Rtg) of a Conductive ESD Floor.
    ANSI/ESD S20.20 requires initial and periodic verification of an ESD Flooring System. ANSI/ESD STM7.1 outlines the test methods applicable for the Conductive flooring material. For the Point-to-Point resistance (Rtt) test the flooring will be tested with a resistance measurement meter and 2 x 5lbs cylindrical electrodes positioned 36” apart. The value for the test should be less than or equal to 1 x 10^6 ohms.
    The Resistance Point-to-Ground (Rtg) test should be conducted with a resistance measurement meter and 1 x 5lbs cylindrical electrode. One lead from the meter should be connected to the ground point and the other lead will be connected to the electrode. The test value should be less than or equal to 1 x 10^6 ohms.
    View the full range of SCS Surface Resistance Testers: staticcontrol.descoindustries...
    For more information, contact SCS:
    E-Mail: Service@StaticControl.com
    Phone: (919) 718-0000
    Website: StaticControl.com
    ©2019 SCS is a brand of DESCO INDUSTRIES INC
  • Наука та технологія

КОМЕНТАРІ • 4

  • @OKSemiconductor
    @OKSemiconductor 3 роки тому +1

    That spacer tool is brilliant!

  • @freddy611esp
    @freddy611esp 8 місяців тому

    When testing the floor, should we worry about the RH?

  • @ngapulisasitepu1879
    @ngapulisasitepu1879 7 місяців тому

    How to check ESD on machine without mat?