5kW Off-Grid Solar System + Diagrams, Consumption

Поділитися
Вставка

КОМЕНТАРІ • 67

  • @cleversolarpower
    @cleversolarpower  3 місяці тому +2

    🎁 Free Diagrams: cleversolarpower.com/free-diagrams/
    📖 My Best-Selling book on Amazon: cleversolarpower.com/off-grid-solar-power-simplified
    ✍Work with me: cleversolarpower.com/product/solar-system-review-service
    Parts:
    Solar Panels (12x): cleversolarpower.com/go/CS400W
    Battery: cleversolarpower.com/go/EG448V (cheaper version)
    Charge Controller: cleversolarpower.com/go/450/100
    Inverter/Charger: cleversolarpower.com/go/5000VA
    Generator: amzn.to/3W4zjxr
    Solar PV cable: amzn.to/4eQcYv1
    4AWG welding cable: amzn.to/4buslX9
    DC Breaker (2x): amzn.to/3L9Ql74
    125A Class-T fuse: amzn.to/3XJPUaX
    Class-T fuse holder: amzn.to/4cgihlD

  • @TheClark918
    @TheClark918 23 дні тому

    This is top notch explanation at the purest simplest form. Thank you!

  • @ihabahmed1132
    @ihabahmed1132 3 місяці тому

    Very Nice Explanation Thank You for sending The Free Diagrams 💐🎁

  • @johntheaccountant5594
    @johntheaccountant5594 3 місяці тому +6

    At 1:10 where did you get the "charging voltage" of 57.6 Volts from?

    • @cleversolarpower
      @cleversolarpower  3 місяці тому +3

      It's the charging voltage of a 48V lithium lifepo4 battery.

    • @vincentzavier9881
      @vincentzavier9881 Місяць тому +1

      I had the same doubt​@@cleversolarpower. Now I can add this to my knowledge. I appreciate your help

  • @vincentzavier9881
    @vincentzavier9881 Місяць тому +1

    At 1:16 you chose 450v 100A charger. But you decided to split the panels into two series strings.
    Why didn't you choose to use all panels in a series string which is still under 450v?

    • @cleversolarpower
      @cleversolarpower  Місяць тому

      1:40 you have to watch a little longer than one minute 😉

  • @pissedoffpuppy
    @pissedoffpuppy 3 місяці тому

    Finally ordered your book😁🤙🏽

  • @herbertvonsauerkrautunterh2513
    @herbertvonsauerkrautunterh2513 3 місяці тому

    I will be using 440w panels with the same charge controller. I already have 20kw of rack batteries which aren't enough.. I don't run much at the moment. I will be buying more batteries to get to 40-50kw.
    My inverter of a growatt LF 12kw. It will be set up and fused for 300a max.

    • @cleversolarpower
      @cleversolarpower  3 місяці тому

      300A fuse size seems ok. The charge controller is great. You can build your own battery as well. Check my video DIY vs BUY lifepo4.

  • @brymstoner
    @brymstoner 2 місяці тому

    nice, but people don't typically unplug their fridges or freezers overnight. from my own experiments, i can run my whole home entirely off my 820W of solar and 7.5kWh of lfp batteries in the height of summer with decent sun (uk, so sometimes it's a gamble!). the rest of the time i plug the fridge freezer, and sometimes the microwave, into the grid. it's not worth grid-disconnecting in the uk - but when there is a powercut, you're usually back on within 8 hours. anything longer, and i'll take the hit as best i can with my solar system.

  • @rexmagat4051
    @rexmagat4051 2 місяці тому

    excellent

  • @walterg4200
    @walterg4200 14 днів тому

    Great presentation!!! Not clear on the 20A breakers. Would those need to be higher?

    • @cleversolarpower
      @cleversolarpower  10 днів тому +1

      12 panels in series gets you 13.85A*4.56=21A -> 20A breaker is enough.

  • @linossinkala7840
    @linossinkala7840 3 місяці тому

    Thankyou sir

  • @AlvinBenipayo
    @AlvinBenipayo Місяць тому

    Do You have Diagrams for Solar Grid Tie on 6,000 Watts Inverter ? Thanks

  • @captronsilveira7087
    @captronsilveira7087 3 місяці тому

    Nice explaination. However I did not understand how the charging voltage is derived.

    • @cleversolarpower
      @cleversolarpower  3 місяці тому

      It's the standard charging voltage for a 48V lifepo4 battery. For a 12V battery, it's 14.4-14.6V.

  • @RadanarAung
    @RadanarAung 2 місяці тому

    Thank you I am trying to be a off-grid soalr designer.

  • @konkaragounakis5924
    @konkaragounakis5924 2 місяці тому

    Excellent presentation, now let me get this right, you can't connect 12 panels in series because of voltage excess, but can you split the voltage 6 panels = 276v in the same charger controller Is this correct? Again great show I enjoy it, thanks Nick 🇦🇺

    • @cleversolarpower
      @cleversolarpower  2 місяці тому +2

      Yes. The charge controller has two mppt inputs, so yes that's why we can separate them.

    • @konkaragounakis5924
      @konkaragounakis5924 2 місяці тому

      @@cleversolarpower thanks for explaining this, excellent explanation.

  • @davet9633
    @davet9633 3 місяці тому

    Victron 5000 is not UL listed; thus, not a good choice in CO (if you want insurance to cover any issues).

    • @cleversolarpower
      @cleversolarpower  3 місяці тому

      Victron 48V MultiPlus-II UL1741 3kVA 120V is UL listed. You can place two in parallel to get 6kW of output. I linked it in the description.

  • @saisubhash1
    @saisubhash1 Місяць тому

    Hi, i dont understand one thing. How is 5000 kva inverter sufficient for 5kw panel? The efficiency is 100 percent whoch isn't possible or am i missing something here🤔

  • @graphguy
    @graphguy 3 місяці тому

    Yesterday I saw a video that shocked me.
    on traditional panels --- ANY shade shatters the pv output. The video demonstrated that even a 5% coverage of shade dropped the output from 93w down to 17w.
    What do you say?

    • @cleversolarpower
      @cleversolarpower  3 місяці тому

      It's true. If you look closely at a solar panel there are cells in series. If one cell receives less irradiance, the current will drop. And the panel will take on the cell with the lowest current.

  • @IAmPGZW
    @IAmPGZW Місяць тому

    How come you never talk of Hybrid inverters? They save money and eliminate the need for a seperate charge controller.

  • @raymondruss652
    @raymondruss652 15 днів тому

    Hello there, I recently became your subscriber and I would like to know if I wanna make a 5 kW solar system In Thailand, which is 220 volts what components and fuses I need thank you and appreciate it
    I am using 600 watts solar panels and 48 volts 280 Amp batteries

    • @cleversolarpower
      @cleversolarpower  10 днів тому

      Check out my systems here: cleversolarpower.com/solar-power-diagrams/

  • @karimali3477
    @karimali3477 2 місяці тому

    Why do some sources say use 1.56 safety factor for DC and 1.25 for A.C side?

    • @cleversolarpower
      @cleversolarpower  2 місяці тому

      we only use 1.56 for cables going from the solar panels to the charge controller. These are called solar PV cables and are rated this way because outdoor situations are very hot.

  • @godswillasagba3949
    @godswillasagba3949 2 місяці тому

    Please what battery backup, inverter, fuse, wire quality and size is recommended for an 8kva pv array? Can you draw a schematic or do a video on it? A customer ask me if i can handle such solar project. For this is the exact off-grid solar his friend is using in powering 4 ice block producing machings and he needs this too to power his own. I'm from Nigeria.

    • @cleversolarpower
      @cleversolarpower  2 місяці тому

      You can take a look at my designing service on my website.

  • @nomsTube
    @nomsTube 3 місяці тому

    Why would you run a fridge for only 8 hours? Usually fridge and freezers are always on.

    • @cleversolarpower
      @cleversolarpower  3 місяці тому +3

      No they are not. They usually have a duty cycle of 30%, which means they are on for 8 hours a day. Check my video about: how much power does a fridge consume? And you will see what I mean with the graphs 😉

  • @wenzydemar4406
    @wenzydemar4406 3 місяці тому

    so in this calculation the battery banc will have a dod of 100%??

  • @godswillasagba3949
    @godswillasagba3949 2 місяці тому

    Can a UPS SYSTEM substitute or do the work of an INVERTER if i remove its internal 12volt battery and run a wire out for connection to external bigger capacity 12volt battery...? Can it power a house? And what are the similarities and differences between the UPS SYSTEM and INVERTER.

    • @cleversolarpower
      @cleversolarpower  2 місяці тому

      To my knowledge an up is a battery charger, inverter and battery in one. You can switch out the battery for a larger one, but it has to be the same chemistry and voltage. It depends on the power output of the ups. Most likely very small. This 5kw system is basically a big ups.

  • @stevenski_brewster
    @stevenski_brewster 3 місяці тому

    Does Victron offer an all in one control center / inverter / charger for this 48v application? Rather than having 2 components. Thanks

  • @alainalbert6663
    @alainalbert6663 2 місяці тому

    So with this setup the charging amperage is reduced to 36 amps..does it mean that with a 24v system the charging amperage be raised to near double to fully use the generator and the inverter capability? Will it charge the bank twice as fast? I'm asking cause i just bought 7 6v batteries that are 9 years old but can't find an other one with the same age to go 48v..so 24v system is on my mind now. I'm new at this. And what make the Honda 3000w more economical than others..i got a yamaha non inverter? Thanks 😅

    • @cleversolarpower
      @cleversolarpower  2 місяці тому +1

      Increasing the voltage will reduce the current. Power= voltage X current. So if you increase the voltage, you have to halve the current to get the same power.

    • @alainalbert6663
      @alainalbert6663 2 місяці тому

      So it will be charging at the same rate..?

  • @OffGridLivingEspana
    @OffGridLivingEspana 3 місяці тому

    are the 20amp circuit breaker also for surge protection/lightning?

    • @cleversolarpower
      @cleversolarpower  3 місяці тому +2

      No, just for isolating the solar panels. I might do a video about surge and lightning protection later.

    • @OffGridLivingEspana
      @OffGridLivingEspana 3 місяці тому

      @@cleversolarpower ok thanks will look forward to that one -

  • @etiennealexantoine4299
    @etiennealexantoine4299 2 місяці тому

    Hi

  • @ihabahmed1132
    @ihabahmed1132 3 місяці тому

    how did we get the charging voltage 57.6 V ? are you assuming using a 48 v battery ?

  • @robertpaulis439
    @robertpaulis439 3 місяці тому

    Nick...please help me understand how you connected the 2 sets of panels to the charge controller???
    Your diagram appears to have 1 set going into the "load" outlet which I question.
    Thanks

    • @cleversolarpower
      @cleversolarpower  3 місяці тому +1

      One set consists of 6 panels in series. It would have been too big to have it one the screen. The charge controller has two MPPT inputs.

    • @robertpaulis439
      @robertpaulis439 3 місяці тому

      @@cleversolarpower how does one connect 2 sets of panels if the controller has just 1 panel hookup?

  • @ansosboy8687
    @ansosboy8687 2 місяці тому

    how to find solar radiation data?

    • @cleversolarpower
      @cleversolarpower  2 місяці тому

      Check my latest video: how much power do solar panels produce

    • @ansosboy8687
      @ansosboy8687 2 місяці тому

      @@cleversolarpower thankyou so much 🙏

  • @jameswebb80
    @jameswebb80 3 місяці тому

    Is it possible to run a 24 V 16s BMS system on 16 3.2 V cells configured in an 8S2P configuration or do you need to separate BMS units?

    • @cleversolarpower
      @cleversolarpower  3 місяці тому +1

      I don't think that is possible. You need a 24V 8S BMS and wire your cells in 8S2P. So wire 8 sets of 2 cells in parallel, en then series connect them. One balancing lead for every two cells.

    • @jameswebb80
      @jameswebb80 3 місяці тому

      @@cleversolarpower thats what i thought but wasnt sure

  • @iohann.bab.7042
    @iohann.bab.7042 3 місяці тому +1

    Too expensive for me, hi quality components are expensive, i think a 24 system with 2v led acid batteries and a easy solar 2 gx everything here is over priced.

    • @cleversolarpower
      @cleversolarpower  3 місяці тому +3

      I might feature this in another video. Thanks for the suggestion.