How to Size a Solar Charge Controller

Поділитися
Вставка
  • Опубліковано 26 гру 2024

КОМЕНТАРІ • 302

  • @cleversolarpower
    @cleversolarpower  10 місяців тому +8

    My book on Amazon: cleversolarpower.com/off-grid-solar-power-simplified
    7 Free off-grid solar diagrams: cleversolarpower.com

    • @paulmwansa5812
      @paulmwansa5812 6 місяців тому

      Sir kindly help I bought the solar generator 12v 1000watts which has 40A control I was to maximum solar panel is 560watts. My question is can solar panel 575watts work too on the same solar generator?

  • @RichardByrd-my3vs
    @RichardByrd-my3vs 9 місяців тому +16

    Sir, you do a fine job of clearly explaining solar power. Best I've seen to date. Thank you!

  • @frankseda1
    @frankseda1 8 місяців тому +3

    Great information. I have a Li Time 60A charge controller . I am using 4 100w panels. I am planning to add 2 more panels. Total 600 w. Equal 42A. Easy to understand now. Thank you very much.

  • @scrub175
    @scrub175 6 місяців тому +1

    Just ordered your book. I have a Grand Design fifth wheel that has a factory installed Furrion 370w solar panel. A Furrion MPPT 60 amp solar charger. PD-9260 Lead acid converter. I installed an Epoch 12v 300ah lithium battery. With the battery swap I also added a blue sea terminal fuse block and 200 amp fuse. I plan to upgrade that to a 300 amp fuse when I complete future mods.
    My plan is to swap the Furrion Solar charger controller with a Victron 100/50 solar charge controller, probably this weekend. I’m also going to swap the Progressive dynamics converter to a PD-9360 lifepo lithium converter. I’ve purchased both of those items already. I’m also going to wire in a solar disconnect between the panel and MPPT.
    In the future I’m going to add the Progressive Dynamic inverter with transfer switch wired up to my pre-installed invert prep sub panel and 10 gauge romex. Additionally I’m will install a battery disconnect between the positive terminal and inverter using 2/0 gauge battery cables. I already have the inverter on hand as well. Just need to order the battery cables.
    I’ve been studying for months trying to utilize more RV specific items rather than full on Victron everything since I’m trying to retain the functions of each component rather than just the wholesale swap over and re-routing of shore power lines, which would in essence then bypass the 12v supply from the installed converter. Plus if I ever wanted to go back to stock I could then retain all my upgraded complements for a new camper in the future.

    • @cleversolarpower
      @cleversolarpower  5 місяців тому +1

      Make sure you get the bluesea systems battery disconnect, it has lower internal resistance. I recommend using windynation welding cables + quality lugs. Thanks for getting the book!

    • @scrub175
      @scrub175 5 місяців тому

      @@cleversolarpower thank you. Good insight, I did purchase the blue sea 9003e battery disconnect.

  • @heroesandzeros7802
    @heroesandzeros7802 8 місяців тому

    I have multiple PV arrays around the house, garage, and at my business, 12V and 24V systems.
    I usually use the 30A Eco-Worthy charge controllers rated for 750W.
    The max output of the smaller PVs is 41.666A but the charge controller never gets anywhere close to that.
    The most I have ever seen is about 21A and that does not last long.
    I also have a 2250W 24V array (3 sets of 3 in parallel with separate feed wires) on 8- 12V lead-acid batteries.
    I use 3- 30A charge controllers in parallel.
    The highest amperage I have seen is about 6A from each charge controller.
    The only loads that I have is an alarm system, a 16 Camera DVR, and a few LED light Bulbs.
    This load does not even scratch the batteries.

  • @richardcurrin7812
    @richardcurrin7812 10 місяців тому +1

    This is the 3rd or 4th video from your channel I’ve watched as I just recently found it and subscribed I paused the video long enough to go to Amazon to order the book Your videos are excellent!

    • @cleversolarpower
      @cleversolarpower  10 місяців тому

      Thank you Richard! If you have questions, feel free to email me.

  • @stevejudge3561
    @stevejudge3561 27 днів тому

    Hi Nick. I'm planning to use a 100watt solar panel mounted on the roof of my RV and then having another 100watt panel portable. I may connect them together if needed but I'm not sure at this point. The solar panels will only be used for a 12v refrigerator. I may connect the system to an inverter but I'm not sure at this point. Doing so would help when connected to shore power. Our primary goal is to keep the fridge running all the time while parked at home or on the road.

    • @cleversolarpower
      @cleversolarpower  25 днів тому

      I made a video about a dc fridge not too long ago. Check it out on my channel. I recommend using two charge controllers in parallel if you are going to have that setup.

  • @Cabernet2000
    @Cabernet2000 Місяць тому

    I have the book. I’m working on adding. 200- 400 portable folding panels that I can carry in a motorhome. It has a 100 W panel and a 10AMp. Kisae charge controller. I want to set up a separate portable panel and controller to pull out when needed but not. Placement of these close to the 4 6Volt batteries is key. My 100w OEM panel on roof does not top off batteries well. So I’m just trying to top off faster. I will follow your book.

    • @cleversolarpower
      @cleversolarpower  Місяць тому

      Good idea on having portable panels in your motorhome. Thanks for the support!

  • @JFK666666
    @JFK666666 4 місяці тому

    Thanks for your very informative videos!
    Currently running a 24V system, with a hybrid inverter. Battery is a 8-cell 280AH LiFePo pack. BMS is a JK Inverter BMS. Hybrid inverter able to do 60A charging. 800W of solar, will be upgraded to 2,4KW in a few days. Energy use model for inverter is set up to prioritize load (household), battery (charging) - and last resort is power from utility. Charging is set up for solar and utility - solar as pri.

  • @Ekanselter
    @Ekanselter 10 місяців тому +2

    Excellent as always. Very good presentation.

  • @pbbmsupporter7926
    @pbbmsupporter7926 6 днів тому

    The fuse you are talking about is the same to MCB circuit breaker.

  • @xe-xx8vu
    @xe-xx8vu 10 місяців тому +1

    I have 6 BougeRV 200W 12V 9BB Mono Solar Panel + 2 100W HarborFreight panels
    I wired everything in series to charge a Bluetti AC300 + 1 extra battery I get 1.0kW on a nice sunny day but eventually I want to setup something with a charge controller to power other things and was wondering what's the right side charge controller to get. great videos thank you.

  • @boothleg3052
    @boothleg3052 9 місяців тому +1

    hi have a 30a charge control what panel should hi use

  • @ktm640
    @ktm640 8 місяців тому

    An excellent informative to the point guild that most people will need. Thanks very much.

  • @richarddouglas5656
    @richarddouglas5656 Місяць тому

    I have a 250/100 for 6x180w panels in 3s2p.
    My voltages worked out at 134v/5a.

  • @KeesBijlsma-ef7zo
    @KeesBijlsma-ef7zo 5 днів тому

    Thanks for this explanation! For my situation I have a question:
    I have solar panels of 2400Watt and 48V batterys: (2400W/57,6V*1,2= 50A)
    The victron models that are available for 48V batteries:
    MPPT 150 45
    MPPT 150 60
    Would you go for the 45A, or the 60A model?
    Thanks!!

  • @outofgasgarage929
    @outofgasgarage929 4 місяці тому

    Thank you for posting these videos! The last example with the 600W solar panels are exactly what I will install on our camper, exellent information!

  • @ZionComing777
    @ZionComing777 6 годин тому

    I am thankful for your tutorials they are great. Here’s a question slow folks like me need answered though. I have a Victron 150/100 charge controller I’m hooking up to 4 335w panels. They have a Voc of 41.0 rating. If my dummy math is correct I can only do 3 panels in series. So what happens to the fourth panel? Could you advise. Thanks.

  • @cameronrudibaugh2247
    @cameronrudibaugh2247 9 місяців тому +1

    Hello! Thank you for the video! It was quite helpful but I was wondering if you could offer some advice with a new solar setup. Another person was working on this project for a non-profit but they couldn't finish the work so I'm stepping in to help out. They ordered three 350W (40.7 VOC) solar panels to run on a 100W/20A charge controller with a 12V battery. Based on your video, the charge controller would be highly inefficient. What size charge controller would you recommend for these panels?

    • @cleversolarpower
      @cleversolarpower  9 місяців тому

      350W*3panels=1050W/14.4V=73A charge controller. You can still use the 20A charge controller, but you can only get 20A out of it. You can get two more of these charge controllers and have three of them in parallel. However, that is not the best solution. You need a 150V input and 70A charge current charge controller. Victron has one.

  • @comep9702022
    @comep9702022 9 місяців тому +1

    Many thanks for this very informational video!

  • @WesselVanSluis
    @WesselVanSluis Місяць тому

    Very clear explication voor people in the USA and while it is just as interesting for the rest of the world would like to ask you to consider to make it easier for global use: most people in the world use global standard unit which is for (copper) wire crossection square millimeters, could you please in cable sizing table add the cross section in mm2 ? Thanks, Wessel

  • @tarinlewis1158
    @tarinlewis1158 Місяць тому

    What about the difference between series and parallel for sizing your mppt controller?

    • @cleversolarpower
      @cleversolarpower  Місяць тому

      In series voltage gets added up, so you have to take that into account for the max allowable input voltage.

  • @TimeSurfer206
    @TimeSurfer206 Місяць тому

    Currently own 2 ea 100W Bifacials, 20A Charge Contro9ller, no battery or inverter yet.
    Key word: Yet. Planning on a grid tie microinverter to balance my use until then.

  • @ahmedwiilwaal
    @ahmedwiilwaal 9 місяців тому +2

    Thank You for the instructional videos 🥀🥀🥀🥀🥀🥀🥀🥀

  • @carlharmon9590
    @carlharmon9590 10 місяців тому +1

    Thank You for the instructional videos I have 2 230AH battery's collected in parallel so 460AH of battery With A Victron 150/70 Charge controller use A 90Amp breaker and 4 Ga Wire on controller?
    and 5 100watt Panels connected in series? Does this seem right?

  • @shortcutcity2786
    @shortcutcity2786 12 днів тому

    I have a panel of 310w/37v/8.38A can u sugest a charge controler and battery for home appliances

  • @graememurdoch9096
    @graememurdoch9096 Місяць тому

    I have a 12 volt inverter but have fitted 3 105 amp hour lithium batteries. What size panels and controller would you recommend?

  • @victorjoseph8948
    @victorjoseph8948 4 місяці тому

    I bought a Victron 100V 30A charge controller for my 2x 200 watts solar panels. 400watts / 14.4= 27.7 amps ok for my victron 100 v 30 amps. I use it to charge my Bluetti Ac 180

  • @leosway4320
    @leosway4320 2 місяці тому

    Victron 75 / 15 - 2 - 100w (19v x 5.6a) panels in series, and 2 series strings in parallel. Moving up to 3 panels for 66v in series. And 3 series in parallel for 300W at 15 A.

    • @cleversolarpower
      @cleversolarpower  2 місяці тому

      I recommend using the Voc for calculations. 3 panels in series is going to be too much for the 75V mppt in cold weather and sunny days.

  • @sphillips6357
    @sphillips6357 2 місяці тому

    Thank you, Sir. In this example, if I was to use two batteries would each battery use a F4 fuse, switch, then bus bar and a larger F5 fuse at the power out of the charge controller? What keeps the two batteries from drawing more amps than the controller can put out? Or does the controller clamp the output amps to only 50a regardless of how many batteries are hooked up in parallel?
    Thank you, Nick, or anyone who can explain or answer this question.

    • @cleversolarpower
      @cleversolarpower  2 місяці тому

      I recommend fusing each parallel battery. So yes, you need two fuses for the batteries. I recommend using the MEGA fuse busbar with integrated fuse from victron. You can see it in my most recent videos. Checkout my video about parallel batteries with different capacities as well. The output of the charge controller is capped at the rated current.

  • @OBsurfdog
    @OBsurfdog Місяць тому

    I have 4 panels, 37.7 Voc and 13.5 Imp, wired two parallel and two series. 12 volt batteries. What size charge controller do I need? Currently, I have a cheap controller that is sending about 70 volts to the batteries. I disconnected the panels and batteries at night and connected the batteries then the panels to reset the controller.

  • @dennisspino2607
    @dennisspino2607 5 місяців тому

    I have 8-100W solar panels 4S2P and a 60A/150V HQST charge controller with 6AWG and a 60A fuse.

  • @AbcDef-ej1fd
    @AbcDef-ej1fd 8 місяців тому +2

    I have one solar panel of 555w and one 100AH battery so how many ampare of MPPT charge controller i required?

  • @Howie47
    @Howie47 16 днів тому

    I have 8 100W panels in partial series = 24 volts and parallel =400 watts and a 40-watt charge controller on 1, 12-volt battery. Soon to be 2 or 3 batteries. Doesn't seem to be any better between using 4 or 8 panels.

  • @owolabiadeteye5919
    @owolabiadeteye5919 6 місяців тому

    Thanks for this lecture, i bought your e-book two days ago, when i was reading through it, i discovered that, in sizing of charge controller for 12V system, you used 12V to divide the Pmax of PV array but in this lecture you are using charging voltage of 14.4V to divide. Any explanation on this

    • @cleversolarpower
      @cleversolarpower  6 місяців тому

      Indeed, I have it different in the book to simplify it. 14.4V is the charging voltage of a lithium battery. So it's a little more accurate. Wouldn't hurt to have 15-20% more, it increases the lifespan of the charge controller. 100W of solar power / 14.4V = 7A

  • @CurtClements-l7z
    @CurtClements-l7z 9 місяців тому

    Great video can i ask for some advice i have a 1000 watt inverter a 10 amp charge controller with one 110 watt solar panel on a 12v system on my RV i would like to up size to two 200 watt panels upgrade to lithium battery and 100/30 charge controller what do you think would be best thankyou

    • @cleversolarpower
      @cleversolarpower  9 місяців тому +1

      Keep the existing 110W solar panel on the 10A charge controller. Add the two 200W solar panels in series with the new charge controller. Two charge controllers on one battery is ok. 400W/14.6V=27.4A -> 30A is ok.

  • @fedex1197
    @fedex1197 2 місяці тому

    great info! i have a 330 watt solar panel and a 12v 190Ah solar battery. i plan to use about 80 watts for about 12 hours each night, my peak sun hours is about 5 to 6 where i live, would this work? or would i need to change something so that i can have it last me the 12 hours i need. thank you so much i am learning alot!

    • @cleversolarpower
      @cleversolarpower  2 місяці тому

      80W*12h=960Wh per day. 330W*5sunhours=1650Wh harvest per day. 12V*190Ah=2280Wh of battery storage (lifepo4). If you are off grid you should have 3 days of autonomy. So 960Wh*3=2880Wh -> battery ok, but you need more solar panels. To recharge 2280Wh with 5 sunhours, you need: 2280Wh/5h=460W of solar panels. (calculation without efficiency losses).

  • @panospapadimitriou3498
    @panospapadimitriou3498 10 місяців тому +1

    2x 100.20 and a 150.35 for future bigger panels .. for 48v and up to 60% of their power!!! i want to see when instal the capability in shade and different angles setups

  • @ffarukblues
    @ffarukblues 4 місяці тому

    Which regulator would you recommend for the 455 W panel' Thanks

  • @lekwizcute1642
    @lekwizcute1642 6 місяців тому

    Very good and informative video thank you very much
    What if I’m using more than one battery
    I’m I going to add up the charging voltages or just the charging voltage for one battery

    • @cleversolarpower
      @cleversolarpower  6 місяців тому +2

      I have videos on series and parallel wiring of batteries.

  • @marcow1964
    @marcow1964 5 місяців тому

    I have 2x 295w panels in series in the area that has full sun on a Victron mppt smart 100/50 and two 330w panels in parallel on the side where there is some tree shading at times, also on Victron mppt smart 100/50. They charge 4 lithium Ion batteries of 24v/100Amp. It basically runs the whole house (but in Spain, so lots of sun hours.

  • @danmurphy7338
    @danmurphy7338 Місяць тому

    I have just bought a 100v/30a Victron controller to replace the PWM. I have 2x 12v lead batteries and only 1x 150w panel. My idea was to extend my 1 panel to 4 panels and add another 2x 12v batteries. Would this be ok for this size charger?

  • @peteroffpist1621
    @peteroffpist1621 2 місяці тому

    On my solar panels on my house I have MPPT chargers, but I have more panels in watts than the inverter rates by at least 10% and has worked fine with overpower without any issues. Is that not also possible to run the regulator at max for a long time ?

    • @cleversolarpower
      @cleversolarpower  2 місяці тому +1

      Yes, you can over-panel your controller. However, it will get hotter and reduce it's lifespan and efficiency.

  • @Retired..Mostly
    @Retired..Mostly 8 місяців тому

    I’m currently sizing my 24volt rv solar setup. I’m planning on installing 1250 or maybe 1500watts of solar (5x250 or 6x250). If I’ve do the math correctly I’m going to go with a 150/70 charge controller to cover either setup. The charger’s maxPV is 150 and the panels VOC is 22.8. I could go with 150/60 controller however it would not allow for any expansion to 1500 watts. Your thoughts please.

    • @cleversolarpower
      @cleversolarpower  8 місяців тому +1

      You should only have a maximum of 5 panels in series. 22.8Vox*5*1.25=142V. You can get a 150/45A charge controller as well. 1250W/28.8V=43A

  • @edcglassworks5771
    @edcglassworks5771 5 місяців тому

    I ordered 4 x 200ah lifpo4 batteries and a 12v 3000w pure sine inverter accompanied by 10 x 100w solar panels. I haven’t ordered the charge controller yet but I’m thinking a 100a mppt should do the trick. I don’t know much about 24v systems but maybe I should swap the 12v inverter for a 24v ?

    • @cleversolarpower
      @cleversolarpower  5 місяців тому +1

      Check my video 'how many batteries for a 3000W inverter' its my most watched video (for a good reason).

  • @gregjacobson2687
    @gregjacobson2687 8 місяців тому

    So glad I found your channel. I am trying to figure out what i need to set up a solar panel(s) to keep my boat battery charged. Currently running a 36V 60AH LiPo battery for my trolling motor. Trying to figure out what i can use as the boat is on a storage lot so not much room for big solar panels.

    • @cleversolarpower
      @cleversolarpower  8 місяців тому +1

      Welcome aboard! You need to wire panels in series to go over the minimum recommended input voltage to charge a 36V battery. For example 3x 50W solar panels in series will give you 18Vx3=54V. This is enough to charge the 36V battery with an mppt. 2 18V panels will not be enough.

    • @gregjacobson2687
      @gregjacobson2687 8 місяців тому

      @@cleversolarpower thank you for the reply. That makes sense sort of lol. Not sure if I will be able to have 350 W panels due to space. What do you think about the MPT boost controllers? Looking at a 100 W 12 V panel with the boost controller to charge, the 36 V battery.

  • @craigbennett47
    @craigbennett47 4 місяці тому

    I use a victron 150/100 charger. 1000w of panels. And a 1000 amp 12v battery bank.
    Its a bit of an overkill. But works great.

  • @NomadRidgeRunner
    @NomadRidgeRunner 3 місяці тому

    .. I live remote a several years. I inherited a simple solar system built by someone who was not very familiar with the components. Four Eco-Worhy 120W, Voc 22.8V, Isc 7.75A, Vm 19.3V, Im 6.31A, solar panels on a wooden frame. Soon a big wind blew them all off the frame, breaking wires and loosening connections. The panels seemed to have been wired in parallel, so I rewired the panels the same and with leftover 12V truck wires and simple tools. Still, with improper wires and duct tape, they charged the three lead-acid deep cycle batteries (that had sat outside thru 2 sub-0F winters and plus 120F summers) for four more years.
    .. Recently the old, mistreated lead-acid batteries presented charging problems, and the solar charge controller fried.
    .. I am rebuilding the system.
    ..
    .. I have four solar panels - EcoWorhy 120W - (Voc 22.8V, Isc 7.75A, Vm 19.3V, Im 6.31A)
    .. I have a Solar Charge Controller - no shade problem - PMW MorningStar PS-30M - (battery voltage 12/24, Max PV Open Circuit Voltage 30/60Voc, Max Input Current 30A, Rated Load current 30A).
    .. I have two new batteries - LiPro 12V 200Ah.
    .. I have an inverter - a SL Euthtion 5000W - (dc input operating voltage 12V, 10V to15, max PV Open Circuit Voltage 30V to 60V, max battery charging current 30A, Rated Load Current 30A)
    ..
    This is what I have with which to reestablish electrical power in our remote cabin home.
    ..
    After watching some of your videos, I see that the components of the system are not ideally matched. Yet, I believe they can go together and make us power from our abundant sunshine.
    ..
    Should I put these panels in sets of two, with two panels in parallel, then the two sets of parallels in series?
    ..
    Should I put the two 12V 200Ah batteries in parallel as 24V ...or in series as 12V?

    • @cleversolarpower
      @cleversolarpower  3 місяці тому

      Do you need that big of an inverter? 5000W is too much for a 12V system. i recommend getting a 48V instead using 48V batteries. A lot depends on the load you want to run. Checkout my video about a load analysis. Your inverter is an all in one system with a PWM. Not ideal.

  • @chukwuemekaejekwu6870
    @chukwuemekaejekwu6870 9 місяців тому

    Please I need an advice I have a solar two panel 190 Watt and one 200 hands battery 30 amp charger controller 6 gauge wire with 1.5 ups

  • @katja4458
    @katja4458 6 місяців тому

    Very interesting! We have a boat a 550Watt solar panel, but a solar charge controller of 30A. There are both, a 12V and a 24V system on the boat. So now I guess I need to find out what the voltage from controller to batteries is, right?

    • @cleversolarpower
      @cleversolarpower  6 місяців тому

      550W/14.4V=38A. Ensure the input voltage from the solar panel is 5V higher than the battery voltage.

    • @katja4458
      @katja4458 6 місяців тому

      @@cleversolarpower So it’s a 12V system which means our solar charge controller is too small for the panel - but what are the chances that the panel ever reaches its maximum capacity in cloudy England? …

    • @katja4458
      @katja4458 6 місяців тому

      @@cleversolarpower Now I have a new issue: When checking the voltage that comes out of our solar charge controller it shows between 16 and 17 V - but it should only be around 13 for a 12 V system or not? The solar charge controller is supposed to set itself automatically between 12V and 24V. What could be the reason for this?

  • @BobMan1952
    @BobMan1952 Місяць тому

    Thank you for doing these videos

  • @EronIler
    @EronIler 4 місяці тому

    Can 12v and 48v batteries be used on the same charge controller? On the same circuit going to the same inverter? I bought your book based on this video. Thank you. I have been able to do some calculations i didn’t understand before. 12kw 48v inverter, 4100w solar panels 10 ct, 250/100 charge controller, 6 200 ah 12v batteries, lots of florida sun. Panels are 410 output and 46v VOC.

    • @cleversolarpower
      @cleversolarpower  4 місяці тому +1

      No, you cannot connect 12 and 48V on the same charge controller. Thanks for your support 🙏

  • @p.r.960
    @p.r.960 2 місяці тому

    Hi Nick, I want to build a system that I can add panels to at a later time. Right now I have two 100W panels, a 12V/100A lithium battery and a 1000W inverter.
    Your formula for choosing the right charge controller is easy to understand, however, I want to add four more 100W panels to my system in the future (600w total). Can I use a charge controller sized for six panels (100W/50A plus the appropriate wires/fuses) for my two panel system mentioned above? Or will it create problems? In other words, can I use fewer panels for a six panel system?

    • @cleversolarpower
      @cleversolarpower  2 місяці тому

      You can have multiple charge controllers delivering power to the same battery. Check out my video 'multiple charge controllers'.

  • @oluwaseunobadeyi6715
    @oluwaseunobadeyi6715 Місяць тому

    Pls What of a solar panel totalling 720 watts to charge two 12 volts 220amp connected in parallel

  • @ChrisKobe
    @ChrisKobe 9 місяців тому

    Hi Nick! Love your videos and just got your book. I am building a 48v system for off grid storage container. I have 100Ah 48v (Li Time). I was hoping to use a 100/20 MPPT Victron I was given to charge it with. I don’t have any panels yet. I get the input voltage limit of CC but can I exceed CC 20 amp charge spec by adding parallel strings?

    • @cleversolarpower
      @cleversolarpower  9 місяців тому

      Thanks for getting the book! Yes, you can add more panels. You will just lose some power because of the over-paneling.

  • @girosdechaimite
    @girosdechaimite 14 днів тому

    in my case 160w panel, 95ah 12v bateria mptt victron 75/15 ah is correct my wires is a 12awg

  • @bawatechreview2168
    @bawatechreview2168 4 місяці тому

    Pls help with the calculations.
    I have a 12v / 240ah tubular battery and three pieces of 45v / 420watts sollar panel.
    What could be the size of MPPT charge controller, wire size and a fuse?

    • @cleversolarpower
      @cleversolarpower  4 місяці тому

      Just repeat the directions in the video. I cannot make it any easier than that.

  • @israelfernandez-np9ce
    @israelfernandez-np9ce 4 місяці тому

    I already have a 40 amps of mppt scc, what, battery I can use and solar panels, thanx

  • @samsonokuto7160
    @samsonokuto7160 6 місяців тому

    Thanks for this. What are the panel's rated Isc and Imp at STC.? (I am interested in the number of strings being just 2)

    • @cleversolarpower
      @cleversolarpower  6 місяців тому

      That depends on the panel you have. Every panel is different.

  • @sebastjanbrezovnik5250
    @sebastjanbrezovnik5250 3 місяці тому

    If I want to go from a 12V to a 24V battery storage to have a lower A on my ChargeController..can I put two 12V Batteries in Series like I do with Solar panel to +(add) the voltage? Or do I need to buy a 24V battery?

    • @cleversolarpower
      @cleversolarpower  3 місяці тому

      You can series connect batteries. But you need to check the voltage when fully charged, over time they can become unbalanced. Meaning one battery can show 13.2 and the other 13.3V. so you have to place a balancer in between. Ideally use a 24V battery, but no requirement.

  • @soloado5084
    @soloado5084 2 місяці тому

    Sir,
    This SCC formula = "solar panel power÷battery charging voltage" , how can you apply it to strings of battery ? Like for instance, if I have 2# of 12volts battery in parallel and we have an 800watts panel. What will be the size of the SCC to match up ?

    • @cleversolarpower
      @cleversolarpower  2 місяці тому

      depends if your batteries are placed in series or parallel. series:24V, parallel 12V. 800W/14.4=56A

  • @eliudmuriigi
    @eliudmuriigi 7 місяців тому

    I have 2 batteries 12v, will I add the 12+12=24 divide by the wattage of my panel or I'll just use 12v?

  • @levtrader4015
    @levtrader4015 4 місяці тому

    Hello Nick, may i ask a question please.: I have a solar controller that came with a recent caravan i bought. Regarding the controller ... with the solar panels disconnected from controller and the battery side connected it has 2.1 volts coming out of the solar input terminals. Shouldn't this read zero? I don't think there should be any back feed voltage present at those terminals. Also do you have a video explaining the reason for having the load terminals of a controller? I thought that if your loads are connected to the battery, you don't need those terminals. Ok thank you and luv your channel and your work. I am learning so much from you :)

    • @cleversolarpower
      @cleversolarpower  4 місяці тому +1

      Yes, this should read 0V. However, 2V is not dangerous. I don't use the load output because it can only support small loads. It does cutoff the discharging when the battery reaches a certain voltage. It acts like a low voltage disconnect. But now with lithium, we don't need that anymore because the BMS will do that.

    • @levtrader4015
      @levtrader4015 4 місяці тому

      @@cleversolarpower Hello Nick, so solar input terminals should read zero volts. How is voltage back feeding into these? Thank You

  • @Dan645ci
    @Dan645ci 6 місяців тому

    thank you, so i have two 200w 24v solar connected in parallel and one 24v battery, so according to the above, i would need a 20amp controller, is that correct ?

    • @cleversolarpower
      @cleversolarpower  6 місяців тому

      200W/28.8V= 7A. A 10A charge controller is ok. Ensure the input voltage is 5V+ over the battery voltage. Wiring in parallel can cause difficulties.

  • @owolabiadeteye5919
    @owolabiadeteye5919 6 місяців тому

    Good day boss, what is the charging voltage for lead acid battery 12V, 24V and 48V system.

    • @cleversolarpower
      @cleversolarpower  6 місяців тому +1

      It depends on the type. Gel AGM or flooded. Check the manual of the battery for the recommended voltages

    • @owolabiadeteye5919
      @owolabiadeteye5919 6 місяців тому

      @@cleversolarpower thanks boss

  • @NaturalBornGriller
    @NaturalBornGriller 8 місяців тому

    Do you have to consider output power? IE you have a 100w panel charging a small battery, and once or twice a day you have a highish amp draw pulling power for 5 minutes and then shutting off - do you have to size your controller to allow for that draw as well? Or for something high draw you just connect it directly to the battery?

    • @cleversolarpower
      @cleversolarpower  8 місяців тому

      The charging and discharging are completely separate. You must wire your loads directly from the battery or busbar. A charge controller doesn't have an influence on the load.

  • @charslansafdarskg
    @charslansafdarskg 6 місяців тому

    Hi dear I have a powmr mppt solar charge controller having capacity 60amp and 160v DC . Can I connect three solar panels of 585w with it for 12v. but manufacturer recommendations is 720w for 12 v and 1444w w for 24v and 2800w for 48v.

    • @cleversolarpower
      @cleversolarpower  6 місяців тому

      The recommendations are the max values, so you are good.

  • @kemalcanseven9594
    @kemalcanseven9594 4 місяці тому

    I reached you through a friend, I have a 5 KW pure sine 48 V smart pwm inverter. When the sun is on, the monocrystalline solar panel (6*550 = 3300 Watt) produces 80-95 V (Connection 2x3 series and 3x2 parallel) no problem! When the sun is off and it is rainy, this voltage drops by half to 50 V. Gel batteries do not charge! Panels connection is updated! Technically, what feature MPPT should I get?
    Note: I reached you through a friend, google translate from English to Turkish
    Thanks in advance for the information.

    • @cleversolarpower
      @cleversolarpower  4 місяці тому

      Why do you have your panels wired that way? It's always better to wire as much panels in series as possible up to the max allowable input voltage of the charge controller.

    • @kemalcanseven9594
      @kemalcanseven9594 4 місяці тому

      @@cleversolarpower Since the inverter supports up to 100V! It was necessary to connect 3*2 series and 3 in parallel!
      Currently Installed System:
      Inverter Mode: Radet Pover 5000VA/4000W
      DC Input: 48VDC, 83A
      AC Autput: 230 VAC, 50/60Hz, 22 A.
      Monocrystalline crystal Solar panel 550 W (Voc): 49.90V+3% V 6 pieces (Sun at the top 85-95 V - Cloudy weather, no sun 45-55 V)
      12 V 100 A *4 pieces gel battery
      In cloudy and cloudy weather, what kind of connection do I need to get and MPPT Charge Control Device to get maximum efficiency?
      I am grateful for your answer and help

  • @ManfredBortenschlager
    @ManfredBortenschlager 2 місяці тому

    Hi Nick,
    Thanks for another really helpful video. I also have a challenge sizing my MPPT:
    My daily energy need is 3500Wh. I plan a 48V system with 2x Li batteries (48V, 100Ah each) in parallel. In order to charge them, I am planning to install at least 5x 400W panels in series. IMP is about 11A, so no problem. But the total VMP is 180.5V.
    So, I would need a really expensive MPPT 250/60.
    Other options I thought about is to use two smaller MPPTs in parallel (each controlling 3 panels) and then feeding into the battery.
    Or using a hybrid Inverter/Charger device which includes the MPPT like the yellow EG4 3kW 48V product that you used in your "6. Medium Hybrid Off-Grid Inverter" diagram on your webpage.
    What would you recommend?
    Thanks, Manfred

    • @cleversolarpower
      @cleversolarpower  2 місяці тому +1

      Depends how dependably you want it to be. If you are on a boat and rely on your power, then i recommend using the two MPPTs in parallel. If you use the EG4 hybrid inverter than you need to add 720Wh of daily energy consumption to it because if it's idle power consumption. The EG4 will require less wiring as well. If you like the EG4 and it meets your requirement than you can go with that one. But if you want to expand your system later and upgrade, then using standalone components is the way to go. You can also wire in 2S2P. Which means two solar panels in series and then paralleled, so you don't go over the max input voltage of the MPPT.

    • @ManfredBortenschlager
      @ManfredBortenschlager 2 місяці тому

      ​@@cleversolarpower Thanks for your insight. The solar installation is for a tiny house and I quite like the idea of the hybrid inverter. Unfortunately, the EG4 is not available in Europe. I did some research and found the LuxPower SNA 3000. The specs look incredibly similar at a surprisingly good price. And the LuxPower has two MPPTs integrated (each accepting up to 385V) !
      Do you have any experience or opinion about the LuxPower SNA 3000?
      Thanks you.

  • @tshepomashaba1091
    @tshepomashaba1091 20 днів тому

    Morning mr I have 470 watt panel,I want know what size of charger I going to work

    • @cleversolarpower
      @cleversolarpower  19 днів тому

      Just follow the directions in the video it's easy.

  • @benfournier290
    @benfournier290 8 місяців тому

    Hello, I'm building a portable 24volt system with 2 small sized 12 volt 100amp Lifepo4 batteries. I have one 200 watts pannel and I ordered the 100/20 and think I would be able to upgrade the solar an other 380 watts. it this correct? I also have a 24 volt 3000 watts inverterI and converted 24v to 12v I'm open to recommendations.

  • @richarddouglas5656
    @richarddouglas5656 2 місяці тому

    Hi, I am setting up 6 x 180W panels on 12V - battery bank I am looking into is 4 x 120Ah LiFePo4 in parallel. My panels pump 45V Voc at 5A per panel. Is a 250/100 mppt too big?

    • @cleversolarpower
      @cleversolarpower  2 місяці тому

      Just replace the values of your panels with the one in the video and you will see. Having that amount of solar i recommend having a 24V or even 48V system. Charge controller will be cheaper. Checkout my video: '12V,24V, or 48V battery systems'.

  • @PassmoreHamunji-cu4gy
    @PassmoreHamunji-cu4gy 3 місяці тому

    Just a question Sir if two solar panels 535 watts are put in parallel what charge controller do I need changing two 12v put in parallel also

  • @BashirMohammed-d5h
    @BashirMohammed-d5h 10 місяців тому

    Thank you for the video, it was quite informative and engaging. I however have a question, combining the panels in series increases the panel voltage to 48v, which of course can be handled by the MPPT SCC but shouldn't the connected battery be a 48v battery too?

    • @cleversolarpower
      @cleversolarpower  10 місяців тому +3

      No, the mppt can always step down the voltage. With an mppt, the current automatically increases. A pwm doesn't increase the current, just cuts the voltage. So a 150voc solar panel string can charge a 12V battery.

  • @briandale8386
    @briandale8386 2 місяці тому

    If I have 5 250 amp hour batteries agm. And I have two 400 amp portable folding solar panels systems . And I can connect all the batteries with a switch. Would you use a 70 amp charger . It’s a lot of amp hours . My charger on shore power will hit them with 130 amps for one hour if they’re around 50 percent . It’s an old heart interface inverter charger.

    • @cleversolarpower
      @cleversolarpower  2 місяці тому

      400W/12V=33A. You will need a 30A MPPT or larger. Recommend charging rate of each battery is 250Ah*0.2C=50A. So in total you should have a max charger of 5*50A=250A. So a 70A charger is suited.

  • @rogerevans2185
    @rogerevans2185 6 місяців тому

    I just purchased your book using your link you provide. I have a question. I have already bought one Victron MPPT that was to small for my solar panels and other items as well. I now have the Victron 150/70 TR and 8 100 watt Renogy solar panels. I have one 12 volt 100ah Li Time battery lifepo4 and I have ordered another one. For my Group 24 Li Time 12 volt 100aH battery it is recommended to charge it at 20 amps but the manual state it can be charged at 50 amps in two hours to a 97% charge. What I have learned is at 35 amps, as was my last Victron 150/35 that I was only using the power from 4 of my 8 solar panels. My question is with my two Li Time 100aH batteries connected in parallel do I have to stay with the recommended 20aH charge rate or can I double the charge rate to 40aH? What I want to do is charge at 70 amps which would be 35 amps times 2. This would get the most use out of my panels but I do not want to harm the batteries. I have a 5100 BTU air conditioner I run and with the 150/70 Victron maxed out in charging it will top out at about 625 watts incoming solar. That will power the AC for the most part. If I turn it down to 35 amp charging then it uses about 450 watts solar but takes out about 50 watts from my battery. These are just average numbers as it depends on shading by clouds and such. Thank you for any help you may provide.

    • @cleversolarpower
      @cleversolarpower  6 місяців тому

      A 12V 100Ah litime battery can be charged and discharged at a 100A current. If you placed them in parallel, you can charge and discharge at a max of 200A. So you still have plenty of space.

    • @rogerevans2185
      @rogerevans2185 6 місяців тому

      @@cleversolarpower Thank you. I trust your what you say and that was what I needed to know. I may need more advice in the future but I will most likely find what I need in your book. I do appreciate your help.

  • @angacamthehobbit-PapaPrepper
    @angacamthehobbit-PapaPrepper 2 місяці тому

    I have 3 350 watt panels each on its own 30amp mppt going into a 400 amp batt Bank.
    (2) 200 amp batts wired in parallel.
    Question
    How many batts can you have in parallel. The max size bank in all in parallel??

    • @cleversolarpower
      @cleversolarpower  2 місяці тому

      For a parallel connection without a busbar i would say max 5 batteries. If you have more, then i recommend using busbars in order for the current sharing to be optimal. Check my video about current sharing to understand why.

  • @owolabiadeteye5919
    @owolabiadeteye5919 6 місяців тому

    Thanks for this informative and educative lecture, pls i am in Nigeria Africa, how can i buy your book

    • @cleversolarpower
      @cleversolarpower  6 місяців тому

      Thanks! You can get it on my website in PDF format or on amazon south africa.

  • @rz6913
    @rz6913 5 місяців тому

    I was wondering if you can help me understand why my victron mppt 250/100 charge controller is running very hot and only putting out 1380watts even though it's connected to a 3300watt solar arrey in parallel.
    Thank you

    • @cleversolarpower
      @cleversolarpower  5 місяців тому

      I assume you are running a 48V system. 3300W*0.8=2640W (realistic power production at noon with sun) 2640W/57.6V=48.8A. Have you cleaned your panels recently? Can you measure the input voltage? Send me an email with your test findings, i don't see replies.

  • @silva9374
    @silva9374 2 місяці тому

    I have 2 550w panels in series for a 24v battery, would a 150/35mppt work?

    • @cleversolarpower
      @cleversolarpower  2 місяці тому

      1100W/24V=45A, if you want to get the full power, better get a 50A MPPT.

  • @uzochukwumadubuobi3793
    @uzochukwumadubuobi3793 6 місяців тому

    Pls for that example you give, can 60ahm controller also work perfectly on 600w panel and 12v 200ahm battery and 3000w inverter... without any issues? 🙏

    • @cleversolarpower
      @cleversolarpower  6 місяців тому

      Don't overcomplicate things. 600W/14.4V=42A --> a 60A charge controller will work.

  • @path1031
    @path1031 4 місяці тому

    Would a 2000 Watt Continuous/4000 Watt Peak Modified Sine Wave Power Inverter, 30amp solar charge controller, with 2 100 watt solar panels be enough to power a 1.5hp pool pump? If not could you PLEASE provide the details on a setup that could handle that?

    • @cleversolarpower
      @cleversolarpower  4 місяці тому

      Most likely not if the pump draws a high startup current. I recommend a low frequency 5kW inverter for that pump. It can run it, but you don't have batteries. You need a 48V system as well.

  • @michaelchristensen3342
    @michaelchristensen3342 6 місяців тому

    Nick,I have 6 210 W panels,going to a 24 V battery bank,will a mppt controller be sufficient

    • @cleversolarpower
      @cleversolarpower  6 місяців тому

      Yes, MPPT is the best option. Try to wire in series if you don't have shade. Also do not go over the max input voltage. So you probably have to wire in 3S2P (3 in series and then parallel with another 3). 6*210W=1260W/28.8V=44A.

    • @michaelchristensen3342
      @michaelchristensen3342 6 місяців тому

      @@cleversolarpower Nick,what size mppt controller will be best as these panels will be at 140v

  • @IsmaelKonare-by9iq
    @IsmaelKonare-by9iq 7 місяців тому

    In your calculation of the charge controller capacity you used maximum power at STC of the panel instead of Max input Voltage. I'm confused. Please can you clarify?

  • @adamsisernik4556
    @adamsisernik4556 9 місяців тому

    Hi, can you pls tell me some info?
    Since we will be charging the 51.2V 230ah 11.7KWh Wall&Floor-mounted LiFePO4 Battery (link bellow) with 3 x 480W solar panels ( Vmp = 37.10, lmp = 12.95A ), we would like to have information on which Victron MPPT controller is suitable so that the battery will be charged properly (Operatin value charge of the battery is 43V - 58V).
    Does the Victron 150/35 match the charging voltage? Which fuse must I get?
    Can such a battery be simultaneously charged from the panels and at the same time transmit energy to other consumers?

    • @cleversolarpower
      @cleversolarpower  9 місяців тому +1

      I need to know your Voc, i will take a guess and assume it's 45V. 45Voc*3panels in series*1.25=168V -> you can only use 2 panels in series. 480W*3panels=1440W/57.6V=25A. You can get another panel and wire the panels in a 2S2P configuration. 1920W/57.6V=33.3A Then you can get the victron 150/35A

  • @OYMInternetRadio
    @OYMInternetRadio 8 місяців тому

    Hi, a bit of confusion regarding the figures. If I have 2 x 130w panels and I have a 24v battery setup with a 12/24 charge controller, does that mean that I divide 230w / 28.8 to get 7.98amps, so I need a 10amp charge controller? As the panels don't come in 12/24 version, how does the system know?

    • @cleversolarpower
      @cleversolarpower  8 місяців тому

      260W/28.8=9A -> 10A charge controller. The charge controller sees the battery voltage. If the voltage on it's terminals is closer to 12V, then it detects a 12V battery. If it's closer to 24V, then it detects a 24V battery.

  • @soleespena6622
    @soleespena6622 8 місяців тому

    So if your having a 20amps mppt and allows only 60volts voc it will be exempted if you turn your battery to 24volts system?

    • @cleversolarpower
      @cleversolarpower  8 місяців тому

      I don't quite understand your question. But you can add up to 60V of solar panels, if the mppt is compatible with a 24V battery and the solar voltage is higher than the battery voltage +5V, then its ok.

  • @DavidArroyo78
    @DavidArroyo78 3 місяці тому

    Great information Sir! Thank you

  • @bmack2076
    @bmack2076 8 місяців тому

    The Question I have has to do with the Max Power (STC) rating of a Solar Panel... say 200 watts, which is the basis for the calculations. If the panels are mounted 'flat' on the roof of an RV with maximum power generated would be less, correct?

    • @cleversolarpower
      @cleversolarpower  8 місяців тому

      Yes, you have to angle them so they are 90° angled towards the sun.

    • @bmack2076
      @bmack2076 8 місяців тому

      In theory "flat" panel installation would reduce the input power to the Charge controller, lessening the concern if the rating of the controller is "borderline"... Correct? @@cleversolarpower

  • @SOLDOZER
    @SOLDOZER 6 місяців тому

    My formula (100V x 0.8)/19.8V = 4.04
    Would I be safe for 4 panels on a 100/50 controller? Or should I go bigger on the controller or reduce to 3 panels in series?

  • @NaturalHerbsForHealth
    @NaturalHerbsForHealth 5 місяців тому

    Please is it possible to use a 570w single solar panel to a 12v battery ? I have a 40a mppt charge controller
    I am asking bcos someone told me if I want to use that single 570w panel I need a 24v battery not 12v

  • @zzzdoerrr2826
    @zzzdoerrr2826 9 місяців тому

    Hello. Thank you verry much. It's really helpfull! Is it possible to use victron mppt as a booster. For exemple i have a ebike with a batterie 48v. 25 amp. And a solar panel 100w 12 v ? I want to charge my bike while riding... let's say with a smal victron mppt. Have a nice day!

    • @cleversolarpower
      @cleversolarpower  8 місяців тому +1

      I'm not sure what you mean by booster. The input of the mppt needs to be 5V higher than that of the battery. You can use a step up DC to DC converter and then feed it into the mppt.

    • @zzzdoerrr2826
      @zzzdoerrr2826 8 місяців тому

      @@cleversolarpower Thank you !

  • @robsonchalwe7021
    @robsonchalwe7021 2 місяці тому

    Solar panel is 18V 150W charge controller 40A battery acid 660 is it ok watching from ZAMBIA 🇿🇲🇿🇲

  • @SamsonGolohor
    @SamsonGolohor 10 місяців тому +1

    I have two batteries 100AH each. Can i connect them in parallel and use a 40A charge controller with two solar panels of 200watts each?

    • @cleversolarpower
      @cleversolarpower  10 місяців тому

      Yes, paralleling the batteries will give you 12V. Wire the panels in series to reduce voltage drop if you use an mppt.

    • @SamsonGolohor
      @SamsonGolohor 10 місяців тому

      @@cleversolarpower Thanks. I appreciate. So I can use my 40A charge controller and my 2000watts inverter?

    • @gojo-n6o6p
      @gojo-n6o6p 10 місяців тому

      It is a Great explanation like it so much,God bless you.

    • @abyidicula2009
      @abyidicula2009 8 місяців тому

      Hi I just want to start 100 w panel with 100 ah battery is that okey to use 75/15 mppt charge controler ?

    • @tompeterson4628
      @tompeterson4628 6 місяців тому

      Is it bad if your charge controller is bigger than the amps my solar panels produce?

  • @CollinBaillie
    @CollinBaillie 10 місяців тому +1

    I think the only thing you missed, was a consideration of what is a safe charging current for your battery (bank or pack)
    If you have a single 75aH AGM battery, you don't want to be charging with more than about 15a.
    For a LiFePo4, you'd probably want to charge at no more than 40a.
    Otherwise a great video!

    • @cleversolarpower
      @cleversolarpower  10 місяців тому

      Good point 👍 I have touched on this in my video about C-rate.

  • @musicrecordstudio
    @musicrecordstudio 7 місяців тому

    I'm truly enjoying your videos, so informative. I have (6) 450w solar panels, can I run them in series using an MPPT 150/70, a 48v 3000VA Multiplus and a 48v 100Ah LiFe P04 battery?

  • @Mmmmmmmiwish
    @Mmmmmmmiwish Місяць тому

    150w 12v panel... 40a dc to dc w/mppt (li time) but it doesnt say what the mppt amps are 🤔

  • @nkosenhlekumalo
    @nkosenhlekumalo 10 місяців тому

    Please for give me if im out off track i want to make a very small 24v system with a 60a PWM
    I would like to find out if it porsable to use a 60amp charge controler to charge two 12v 7amp connected in series

    • @cleversolarpower
      @cleversolarpower  10 місяців тому

      Check my video about C rate for more information.

  • @byronsowntime
    @byronsowntime 9 місяців тому

    maybe a silly question.. I have 2 panels of 540 watts each and voc is 50. I have a 100v to 30a charge controller from victron..what combination should use? series or parallel or can i use it at all?

    • @cleversolarpower
      @cleversolarpower  9 місяців тому

      You should wire in parallel.

    • @byronsowntime
      @byronsowntime 9 місяців тому

      @@cleversolarpowerthanks ...ill hit your sub right now

  • @ronethridge9875
    @ronethridge9875 2 місяці тому +1

    Do you have two books out 😮😮😮😮 thanks much 😅😅😅😮😮😮