Instrumentation interview questions and answers on control valve pid controller pressure transmitter
Вставка
- Опубліковано 28 лис 2024
- #instrumentation #controlvalve #pneumaticvalve #pneumatics #pidcontroller #pressuretransmitter #pressuregauge
we will discuss instrumentation interview questions and answers on control valve, pid controller, differential pressure transmitter, pressure gauge, pneumatic actuator, current to pressure transducer. Engineering study uploads instrumentation and control engineering videos. video is helpful for instrument technician interview, field instrumentation, process automation, factory automation, industrial instrumentation. most of these instruments are controlled by plc dcs and scada system. these controllers are industrial controller.
Launched a course for instrumentation technicians and engineers.
"Introduction to Industrial Automation and Instrumentation "
Course link with promo code applied. Buy only at 499.
For more details WhatsApp at 9634391038
engineeringstudy.graphy.com/courses/Introduction-to-Industrial-automation-and-instrumentation-6489af68e4b0a8e39ac8b844-6489af68e4b0a8e39ac8b844?promoCodeBanner=true
Or click at
engineeringstudy.graphy.com/
Very informative and helpful. Keep it up 👍👍
Thanks for your support
aap ke vedio sea bahut kuch sikhne milta hai thank you sir
Thanks for your motivational comment 🙏🙏
Super sir ji
Thanks🙏🙏🙏
Thank you so much
Your most welcome 🙏🙏
Air to close to tubing diaphragm ke uper se hoga.. na ki niche se.?
Haan vo galti se bol diya usko video me aage mention bhi kiya hai. Thanks for your suggestion
Sir please make videos on p&id also which will be very useful.
Ok
It would be better if you explain that also in English
Sir what about for KP..??
Air to open niche se aplly krte hai dost
Haan, vo by mistake ho gaya, sorry
A to open and A to close identification is wrong .. correct this ans,
Thanks for your suggestion. It is by mistake and also mentioned in video
Air to close and air to open process is wrong please should be correction that.
i agree with u he said wrong when the pressure will apply from top of the diaphgram it is known as air to close and when the air is applied from down of the diaphargm it is known as Air to open