Top 30 Instrumentation and control Interviews Questions & Answers

Поділитися
Вставка
  • Опубліковано 29 вер 2024

КОМЕНТАРІ • 78

  • @that1electrician
    @that1electrician Рік тому +29

    I have never seen these questions pop up in any of my industrial electrician/ instrumentation job interviews, except for how to measure 4-20mA and what is a TC, RTD. This is some pretty advanced stuff.
    The ones Ive always been asked are:
    1.Explain 0-10V and 4-20mA and pros and cons.
    2. What are the color of the leads of a Thermocouple? Which one is + and --?
    3. Do you pour water into acid, or acid into water?
    4. How do you terminate a shielded cable. Which side of the cable do you ground?
    5. What does 3-15 mean?
    6. Do you know what zero and span means?
    7. How do ultrasonic sensor work?
    Theres a couple others that always come up. Theyre pretty basic.

    • @InstrumentCalibration
      @InstrumentCalibration  Рік тому +1

      Hello
      Thanks for your valuable feedback on this video

    • @MR-nl8xr
      @MR-nl8xr Рік тому +5

      Good Comment.
      Do you have the answers for those questions?

    • @InstrumentCalibration
      @InstrumentCalibration  Рік тому +1

      We do@@MR-nl8xr

    • @imayleakount9610
      @imayleakount9610 Рік тому +2

      What other questions can you think of that would probably come up. Any videos/literature that someone who has been out of the field for a while could use to brush up on instrumentation basics? Thanks

    • @InstrumentCalibration
      @InstrumentCalibration  Рік тому +3

      Hi @@imayleakount9610
      We have made a decent chunk of videos on HART, CONTROL VALVES, and basic instrumentation interviews. Kindly check those :)

  • @mr.omprakashbarure4981
    @mr.omprakashbarure4981 9 місяців тому +1

    Excellent❤

  • @AlwellNwogu
    @AlwellNwogu Рік тому +1

    I'm interested in learning about instrumentation and control
    What is the easiest way to learn instrumentation

    • @InstrumentCalibration
      @InstrumentCalibration  Рік тому

      Hello Alwell
      You can start with our videos. If you watch all our video, you will definitely get some basic knowledge about I & C.

    • @Practical.instrumentation
      @Practical.instrumentation Рік тому +1

      Search Practical Instrumentation
      Channel

  • @albarslane8599
    @albarslane8599 Рік тому +3

    It's very good explication but there are many information at once sow if you dont mind i have a proposition what if you did mini vidéos ans focos on evry part at once thankyou

    • @InstrumentCalibration
      @InstrumentCalibration  Рік тому +1

      Hello Alb
      We have created series of video too. Please see below links.
      1. ua-cam.com/video/4lbKLuB-cRs/v-deo.html
      2. ua-cam.com/video/4lbKLuB-cRs/v-deo.html

  • @charanmvg6433
    @charanmvg6433 6 місяців тому +1

    transmitter mounting for steam service .picture equlising valave position check once.

  • @MR-nl8xr
    @MR-nl8xr Рік тому +1

    Diagrams 5:24 and 5:37 are backwards, if you are showing them in "gravity" fashion.

  • @sadanalasaran8335
    @sadanalasaran8335 3 місяці тому

    Loto explain
    Loto-logout tagout

  • @asingwirebonus3479
    @asingwirebonus3479 Рік тому +2

    Thank you for the video. Help me send me a video on analog scaling in PLCs

  • @sundaramnarayanan1375
    @sundaramnarayanan1375 9 місяців тому +1

    add questions on Cold Junction compensation?

  • @nuhbellos3794
    @nuhbellos3794 5 місяців тому

    Does anyone have any insight into what the physical field evaluation and written evaluation would entail for an E&I Apprentice position? I passed the EEI MASS test and have these coming up. Thanks

  • @okaforignatiaus345
    @okaforignatiaus345 Рік тому +1

    Good day, pls I need a video on CALIBRATING TRANSMITTERS USING HART COMMUNICATOR

    • @InstrumentCalibration
      @InstrumentCalibration  Рік тому

      Hi
      Please check the HART videos on our channel, we have videos on the requested topic
      Let me know if you want us to provide the link in the comment section

  • @heatherquick4095
    @heatherquick4095 5 місяців тому +2

    Commissioning a DPT is wrong , for some meters this procedure would destroy them straight away.

    • @jackfeak2364
      @jackfeak2364 5 місяців тому

      I agree. I would think bypass closure would be last. If you open the HP side first with the bypass closed the transmitter would see a very large pressure differential. Example: if the transmitter was taken out of service or replaced on a 450lb steam flow system and you opened the HP side the DPT would see a 450 lb differential. Often times steam flow transmitters are calibrated 0 to 100 inches of water using orface plates so damage could be a real possibility.

    • @karoly365
      @karoly365 Місяць тому

      @@jackfeak2364The steps mentioned in the video is first open EQ and then only HP. Then why do say it is the opposite.

  • @KiranKumar-hk3zk
    @KiranKumar-hk3zk Рік тому +1

    Please make a clear video of AI AO DI DO signal connections from field to dcs

  • @sadanalasaran8335
    @sadanalasaran8335 3 місяці тому

    VIDEO is super nice explain but video is high

  • @Reeshichohan
    @Reeshichohan 9 місяців тому +1

    Sr i am instrument technician can u tell.me which course i do for furture carrier growth.

    • @InstrumentCalibration
      @InstrumentCalibration  9 місяців тому

      Hello Beats
      Have you done engineering in Instrumentation and Control?

    • @Reeshichohan
      @Reeshichohan 9 місяців тому

      @@InstrumentCalibration sr I complete.diploma.electeonics and communication and 2 years exp.in instrument and 5+years exp.in electronic

  • @theomnyakeni4288
    @theomnyakeni4288 5 місяців тому

    Why are we using 4-20mA and not 0-20mA?

  • @georgemoholo192
    @georgemoholo192 6 місяців тому

    I need psychometric test

  • @rodrigabtonio2203
    @rodrigabtonio2203 Місяць тому

    exelent, GOD BLESS

  • @kirankumargadwal4678
    @kirankumargadwal4678 Рік тому +4

    Thank you, almost all important questions are covered. Please do more videos on interview QA

    • @InstrumentCalibration
      @InstrumentCalibration  Рік тому

      Hello Kiran
      Thanks for your comment. I will post more videos on interview questions and answers in future.

  • @harikumarhari8882
    @harikumarhari8882 5 місяців тому +1

    good😍

  • @eggxecution
    @eggxecution 29 днів тому

    nice

  • @RaviKumar-fs4cp
    @RaviKumar-fs4cp 8 місяців тому +1

    Thank you

  • @RaviKumar-ex9ne
    @RaviKumar-ex9ne 6 місяців тому +1

    Very useful video

  • @rakeshrajak7655
    @rakeshrajak7655 Рік тому +1

    Thank you sir
    Very nice

  • @OmkarRatre-i3j
    @OmkarRatre-i3j 2 місяці тому

    Supper

  • @sihlemlangeni1929
    @sihlemlangeni1929 9 місяців тому +1

    Thank you very much. The Q&A is simple to understand and on point . This has helped me a lot .

  • @sulusk267
    @sulusk267 Рік тому +1

    It’s good one

  • @alpeshpatel7111
    @alpeshpatel7111 Рік тому +1

    NicE

  • @SlimaneAutomation
    @SlimaneAutomation 5 місяців тому

    Thanks for the information

  • @johnpeter6451
    @johnpeter6451 9 місяців тому

    Can u explain about working of by pass valves

    • @InstrumentCalibration
      @InstrumentCalibration  8 місяців тому

      Hi
      Thanks for the comment.
      Our tech team is working on this content

  • @AzharPsas93
    @AzharPsas93 5 місяців тому

    Excellent ❤

  • @muscatmama
    @muscatmama 4 місяці тому

    Fantastic

  • @bursty1382
    @bursty1382 8 місяців тому

    9:14

  • @sushildurafe9037
    @sushildurafe9037 Рік тому +1

    Why HP & LP tapping is done at 45 degree in process line for FIT
    Where K type TC is mostly used
    Explain transfer of signal from DCS to control valve
    How to calibrate interface level transmitter.
    What is actually marshalling cabinet

    • @InstrumentCalibration
      @InstrumentCalibration  Рік тому

      HP & LP Tapping is done at 45 degree in process line to avoid any entrapped gases & to avoid any pipe dirt particles in pipe lines
      Type K is commonly used in nuclear applications because of its relative radiation hardness.
      DCS sends 4-20mA signal to I/P converter. I/P converter converts 4-20mA signal into 3-15 psi signal. Then 3-15 psi signal goes to control valve to control the flow.
      I have made one video on Interface Level Measurement.
      Please see below link.
      ua-cam.com/video/Z9S2mgVM3FU/v-deo.html
      The marshalling cabinet acts as an interface between the system cabinet and field junction boxes. The main cables are laid from the field junction boxes to the marshalling cabinet. The prefab cables from the system cabinet IO cards are also terminated in the marshalling cabinet.

    • @sushildurafe9037
      @sushildurafe9037 Рік тому

      @@InstrumentCalibration Guided wave radar type interface level transmitter calibration, what will be zero and 100?
      Working principle of ESDV and types?

    • @sushildurafe9037
      @sushildurafe9037 Рік тому

      @@InstrumentCalibration When FIT is showing zero what will be position of FCV fully open or close.

    • @that1electrician
      @that1electrician Рік тому +1

      ​@sushildurafe9037 You're like, so smart bro.

    • @kanchorintalamia7308
      @kanchorintalamia7308 Рік тому

      @@InstrumentCalibration

  • @gugulothuvenkateswarlu6814
    @gugulothuvenkateswarlu6814 Рік тому +1

    Exallent

  • @abdessamedghettas7167
    @abdessamedghettas7167 Рік тому

    Thanks

  • @faisalmalik7408
    @faisalmalik7408 Рік тому

    exilent 👍

  • @rkmohapatro
    @rkmohapatro 7 місяців тому +1

    this video is vwry helpful for interview