Underfloor Heating - The 2 Big Questions

Поділитися
Вставка
  • Опубліковано 24 лип 2024
  • Roger has some answers for the most common questions from Skill Builder viewers.
    ==========================================
    #ufh #underfloorheating #heatingandplumbing
    🔗 Skill Builder Link Tree: linktr.ee/skillbuilder
    👍 Tell us what you like: skill-builder.uk/vote
    📪 Ask Skill Builder: skill-builder.uk/send
    🎥 TikTok: / skillbuilder
    📣 Facebook: / skillbuilderchannel
    📷 Instagram: / skill_builder
    🛒 As an Amazon Associate, we earn from qualifying purchases
    🎬 All videos: ua-cam.com/users/skillbuilderc...
    💧 We Support Charity Water: www.charitywater.org
    ◾ Out of respect to our channel sponsors and the wide variety of people who watch our videos, we'll remove comments that do not follow common standards of politeness and decency.
    ✅ ▶ ⏩ 🔘 ⚫

КОМЕНТАРІ • 175

  • @Tensquaremetreworkshop
    @Tensquaremetreworkshop Рік тому +2

    Some great stuff in this! I agree that a hybrid system has a lot going for it- background heat with rapid response to peaks. My son fitted 270mm insulation below the screed, but with a wood block floor finds having high output rads great for quick adjustment of ambient. He has a data link to the combi boiler (had to go to a foreign source for the data structure- UK not keen on divulging this) and wireless links to all rads etc with full flow and temperature monitoring, and links to weather forecasting. Had to design/build it all himself- because a commercial version is not available! Like most of building practice, we are still in the last century...

  • @albertojimenezmarin3804
    @albertojimenezmarin3804 Рік тому +179

    I am fully impressed! It's just a complete ua-cam.com/users/postUgkxGqOCINHE0Z0E5gxzSdNi9NWGugRY5Hm2 plan with the best resources and step by step instructions . These shed plans are so satisfying as if the sheds build themselves on their own. Worthy work Ryan!

  • @gdfggggg
    @gdfggggg Рік тому +11

    I get in a right old kerfuffle thinking about all this stuff. One day the building inspector say’s do this, the next inspection another ones says don’t do that. Live off grid and do what I bloody want I reckon 😂. Cheers Rog.

  • @elslopez
    @elslopez Рік тому +37

    I replaced all the heating in a 120 year old house with under floor, every single room up and downstairs, over 3km of pipe work. The high ceilings meant rads were next to useless and the floor was like ice anywhere round winter time, so now no rads in sight and I can say under floor is excellent, it is night and day levels of difference even when compared with particularly good rad systems. Highly recommend if you can. Manifolds also will allow you to easily add zones so the heat distribution can be controlled per room!

    • @SkillBuilder
      @SkillBuilder  Рік тому +6

      Did you insulate the floors?

    • @manojbharadwaj1120
      @manojbharadwaj1120 Рік тому +1

      Looks like the next big thing

    • @WatchingTheo
      @WatchingTheo Рік тому +3

      Did the same in my victorian house. Did 100mm celotex between the joists. Love the UFH

    • @elslopez
      @elslopez Рік тому +18

      @@SkillBuilder I did not personally do the work (just lived through it), looking back I feel probably more insulation could have been added. However the house floors were all just floorboards on raised joists, so not concrete that will conduct all the heat to earth. The pipe work was set into that concrete style board with the pre cut grooves. My guess is some heat does escape down, but it seems ultra effective, so I guess not that noticeable. Upstairs I am less bothered by potential leakage downward since it will only end up inside the house either way... the ceilings do not get hot and I have checked with a thermal imaging camera. What I like is the old house was never designed to have radiators, so they would have only looked out of place and get in the way... I will say it is not for the faint hearted ripping all the floors up adding all the infrastructure, which means raising the height of the floor by 3-4cm shaving all the door bottoms down then putting all the skirting board back etc.
      This was done in conjunction with a new oak hard floor. I avoided carpets as felt this may be too insulating.
      One other thing people always forget to mention is that once you have this done you cannot go filling your house up with furniture that is flush to the floor as this just traps the heat... it became obvious that furniture needed to have legs of a certain height that will allow the heat to flow round objects.

    • @mistervelux
      @mistervelux Рік тому +2

      @@elslopez really helpful! Thanks for taking time to share! I would have never thought about the furniture issue!

  • @Mc674bo
    @Mc674bo Рік тому +3

    Are bless , your never alone because we are right behind you . Yes a complex subject , yet with sound advice from you there can be light at the end of the tunnel . Best wishes and kind regards my dear friend , and may you continue to give sound advice to your many followers . 😀👍👍👍

  • @Itchytriggerfinga
    @Itchytriggerfinga Рік тому +1

    I’ve done the same in my last house and my current one. It works brilliantly.

  • @johnf3326
    @johnf3326 Рік тому +4

    My mate has underfloor dowstairs. Its great. 19c in his house feels warmer than 19c with our radiator system because the heat is rising from the floor, as it should do, not accumulate near the ceiling

  • @grahamdrew1069
    @grahamdrew1069 Рік тому

    Thanks again for your clarity and your answers...it's hard to get answers out there

  • @davidianwalsh
    @davidianwalsh Рік тому +3

    When I built my house I installed a full underfloor wet system from Nu-Heat, can’t fault it - just fantastic - I’ll never go back to a radiator system!

  • @rush211251
    @rush211251 Рік тому +19

    I installed underfloor heating in our kitchen extension three years ago , and I can honestly say , it’s the best thing we ever did .
    Our heating comes on at 6 in the morning for an hour or so , we set the thermostat at 19 . But due to the tiled floor being like an enormous storage heater , by 9am the temperature is over 20 degrees , and stays like this all day . Fantastic

    • @jessegee179
      @jessegee179 Рік тому +3

      Sounds great, was that a full wet system? We’d like to get rid of our carpet, like our neighbour, but her floors are freezing.

    • @ln5747
      @ln5747 7 місяців тому

      Tiles make no difference to energy used.

  • @Cruner62
    @Cruner62 Рік тому +2

    I have underfloor heating to 3 floors for 15 years and the designers got it spot on because I have measured all the rooms in all weathers I totally agree with your accounts. In my system it is set on a very thick concrete raft and then 50mm of insulation set in a self levelling anhydrite screed. I think they did great job in the design since all the wall, floors, ceilings and windows were calculated for thermal distribution. The first floor ceilings were a Bison hollow core slabs across the whole width of 8 m span insulated and covered with the pipes embedded in the anhydrite screed. incidentally the pipe are just 10mm fast flow diameter that I held some reservations about but proved they got it right since there is more mass in the screed to act as a heat store rather than water and plastic. still not sure about that but hey oh it works. With the tiny condensation gas boiler it has been a dream to live in. Love your video as usual.

    • @TheDankelsall
      @TheDankelsall Рік тому

      Did you go for the optional flux capacitor or leave it?

    • @Cruner62
      @Cruner62 Рік тому +1

      @@TheDankelsall Hi Dan, I did ask NHBC if there was anything else I could do back in 2002 but they said I still need ventilation and any heat recovery system simply would not be practical - so back to the future here we go:

  • @tospicy4ya
    @tospicy4ya Рік тому

    I’m doing an attic conversion and I’m going to use the mat I only need 2 m so not massive but I’m trying to keep the height down can I use king span under floor boards instead of a thermal matt or take the boards up and lay some kind ply/insulation board then electric matt , adhesive and tile ?

  • @42RHD
    @42RHD Рік тому +6

    Really useful! Thank you.
    I like your pinching the return off the radiator idea.
    My elderly set up sort of has this by accident because they didn't insulate it.
    Consequently there's a few hot spots on the floor in the bedroom and bathroom where the radiator pipes warm up the carpet/lino that I've got into the habit of aiming for on cold mornings as it's sort of accidental underfloor heating.

    • @Tensquaremetreworkshop
      @Tensquaremetreworkshop Рік тому

      I have the same- deliberately. When I installed the system, I realized the feeds (multi-system) and return ran under the bathroom floor. I did not insulate these (which modern regs require) and the result is a floor that is comfortable to bare feet. A feature that cost less than nothing!

    • @42RHD
      @42RHD Рік тому

      @@Tensquaremetreworkshop My next house I'm doing that!

  • @TayRoss411
    @TayRoss411 Рік тому

    I’m looking to do this in a 120 year old tenement. It is elevated ground floor with a meter of clearance under the floor. Longer term I’m applying to dig this out for a basement. The floor is currently wooden joists and floor boards. Can i go under the floor and kingspan between all joists then lay the underfloor heating on top? Essentially wondering if the wooden floorboard separation between the piping and kingspan will cause any issue?

  • @GavinLawrence747
    @GavinLawrence747 Рік тому +1

    Def in the market for a WHR manifold !

  • @HappilyNorth
    @HappilyNorth 7 місяців тому

    I've just moved in to a property with a combi boiler and underfloor heating. Am I right in thinking that in winter I leave the heating on all the time at say 21 in the couple of rooms I'm in most of the time and around 19 in the rooms I'm not in as much?
    It didn't compute when I was first told this as it sounded very expensive.

  • @uptwisting
    @uptwisting 10 місяців тому

    I removed all my radiators and stuck in UFH, which is heated by my 30 year old Netaheat Profile boiler. The boiler does cycle but we used to run the rads for 2 hours in the morning and 2 hours in the evening to get us warm for those periods. Now, we run it for 2 or 3 hours in the morning and again in the evening and the house stays warm all day and night. Turned the boiler down to 55 degrees, UFH runs at that temp too, 120 year old timber floor using spreader plates and air tight suspended timber floor.
    It has been a surprising revelation.

  • @TheMark1840
    @TheMark1840 Рік тому

    Hi Roger. Im interested in doing exactly what you said for my bathroom. I didnt quite understand - is the pipe ( presumably plastic) in direct contact with the underside of your plywood floor or held away from it?

    • @itfben
      @itfben 8 місяців тому

      my understanding is, the closer the better, but direct contact is not always possible. Please if it is just the radiator water pipe against the floorboards then it still have air space around it, which creates ineffeciencies.

  • @chbtrust8715
    @chbtrust8715 Рік тому

    I am planning a kitchen extension with underfloor heating, would you recommend i install a insulated block and beam floor instead of using standard concrete blocks?

    • @SkillBuilder
      @SkillBuilder  Рік тому +1

      If you can get it but I have never found a supplier, it seems that it only goes out to big sites.

  • @macmusica
    @macmusica Рік тому

    I set Ground floor to 45 and Suspended floor at 55 (all screeded) but plumber refused to service the Auto Air Vents. Now every Flow Meter is 1/2 filled with AIR. Is this ok as I do not want to bother with Services as it has a good BAXI Boiler plus new added Adey Micro2 Filter for my own annual cleaning?

  • @riddlydiddlyimawantedmanin4442

    Your channel is fantastic

  • @9P38lightning
    @9P38lightning Рік тому

    Roger please give me instruction on how to switch on my ufh for the first time, heard horrow stories of bringing the Temperature up too. quickly / too hot. I have a thermostat in the screed and what can be described as a thermostat valve near the the manifold.... Any advice would be appreciated....

    • @SkillBuilder
      @SkillBuilder  Рік тому +1

      Generally you bring it on a little at a time by turning the blending valve down to 1 and then working upwards until you reach 4.

  • @adammawdsley7778
    @adammawdsley7778 Рік тому

    Hi Roger, what are your thoughts on using a multifoil insulation laid on top of solid concrete and ran up the walls a few inches, battened (3×2, possibly 2x2) then underfloor heating finished with 18mm floorboards

    • @SkillBuilder
      @SkillBuilder  Рік тому

      I would rather see pir board inbetween the battens. If you squash the mulitfoil you lose a lot

    • @wittywoo9559
      @wittywoo9559 Рік тому

      @@SkillBuilder what's the minium size pir board I could use as I only have 50mm to play with ..

  • @_stokyo_
    @_stokyo_ 10 місяців тому

    Hello Roger, have you ever installed a system where you can't raise the floor height at all? I have a room upstairs (in my roof) that I use as an office ~3.5m2 . It has old woodern floor underneath and a pretty rubbish radiator. Since it gets really cold (in Sweden) during winter I was tempted to spir off a line and use a router to run a channel for the pipe into the floorboards. Thoughts? Bat shit crazy or doable?

    • @keithianlocke
      @keithianlocke 7 місяців тому

      Look at the systems which sit flush between your floor joists.

  • @jasonantigua6825
    @jasonantigua6825 Рік тому +3

    This is flipping brilliant! Thanks Richard

    • @eddjordan2399
      @eddjordan2399 Рік тому +3

      Roger

    • @jasonantigua6825
      @jasonantigua6825 Рік тому

      @@eddjordan2399 ?

    • @SkillBuilder
      @SkillBuilder  Рік тому +3

      Jason always calls me Richard, it is his little joke, it amuses him and we would never want to come between a man and his entertainment.

    • @jasonantigua6825
      @jasonantigua6825 Рік тому +1

      @@SkillBuilder I really appreciate that Richard! Thanks mate.

  • @Stratoszero
    @Stratoszero 11 місяців тому

    Hello Roger, as an alternative to underfloor heating for small rooms with limited wall space, what do you think of infra red ceiling heaters? I would love you to do a video on those.

    • @SkillBuilder
      @SkillBuilder  11 місяців тому

      They give you a hot head and cold feet. I would rather put them on the wall

  • @markatchison9974
    @markatchison9974 Рік тому +2

    I have underfloor heating downstairs. I put down 3" Kingspan, ran the pipes & 4" concrete over that + tiles.
    I didn't insulate the lower area of the walls (mistake). I lose heat by it radiating outwards through the walls.
    Silly me. My floor level runs straight out onto a patio & heats roughly 18" of it, outwards from the building.
    Put an insulation break between the inside & outside. Like a bathtub effect.

    • @SkillBuilder
      @SkillBuilder  Рік тому +2

      I hope it wasn't concrete you used to cover the pipes.

    • @utubeape
      @utubeape Рік тому

      @@SkillBuilder is screed OK, (I assume thats what he means)

    • @markatchison9974
      @markatchison9974 Рік тому

      @@SkillBuilder A cement based screed. Not exactly sure what it was (a company did that part of the job). They put a lot in. The floor takes roughly 4 hours to warm up fully. It's been down for 6 years with no issues.

    • @markatchison9974
      @markatchison9974 Рік тому

      @@SkillBuilder Dry screed. 4 - 1 sand, cement mix with some aggregate.

  • @rayloftus4066
    @rayloftus4066 Рік тому

    i only have wooden suspended floors (joists and floor boards) whats the best way for me to install under floor heating? if i use 120mm kingspan suspended between the joists then run my pipe should i cut out a hole for the pipe or should i go under them so as not to weaken the joists? on top of that im planing to use 18mm kaberdeck finished off with LVT glued down. any help is appreciated. thanks

    • @SkillBuilder
      @SkillBuilder  Рік тому

      If you go to our home page and type in underfloor heating in the smaller search bar it will show you a few different systems. You can now get 22mm chipboard that is routed out to take the pipe, You still need the insulation but putting all the pipe above the joists has advantages.
      If you go for the pipe in tray method between the joists then I would notch the joists on the cross overs. Strictly it should not be too close to the ends but it is much easier than trying to drag the pipes through the holes. Going under is fraught with problems.

    • @rayloftus4066
      @rayloftus4066 Рік тому

      @@SkillBuilder thanks

  • @Clark-Mills
    @Clark-Mills Рік тому +1

    0:28 Looking at the pipes leaving the manifold... There must be a better way to distribute the fluids to minimise heat transfer between hot and cold? I'd suggest spray-foam but suspect that the concrete overhead would be too thin. Maybe there could be a moulded polystyrene panel that drops in that replaces the board below? Just to reduce the inadvertent heat exchanger that we're looking at, especially after the concrete's poured.

    • @SkillBuilder
      @SkillBuilder  Рік тому +1

      it is not an issue, it works well and you don't have to spend the rest of your life worrying about it. The mixer valve means the water does another tour or two.

    • @Clark-Mills
      @Clark-Mills Рік тому

      @@SkillBuilder Thanks. Seriously though... I appreciate your work - you take us places we never go and I just chime in here and there; A bit of a PITA but really just food for thought. I'll throw some $ in your coffee mug after posting this. Just wanted to say thanks. Have a great break and lets see if next year is kinder... ;)

  • @robertcole7500
    @robertcole7500 Рік тому

    Very informative video.
    In my case, I'm planning to build a 6 meter extension up/against the original concrete base of my house. It's my intention to have the extension concrete base lower than the existing base, to accommodate: installation, pipes & screed.
    Can you you advise on the: optimal insulation thickness, desirable diameter of pipe, and thickness of creed. I'm hoping to ascertain the overall depth requirement to accommodate all three components for a heating system that wouldn't require radiators.
    Regards
    R

    • @SkillBuilder
      @SkillBuilder  Рік тому +2

      Hi Robert
      The required insulation thickness is usually 100mm PIR but it is dependent on the perimeter so it can vary to get the U value. Depth plant for 120 mm if you can. The pipe is usually 16mm and the screed on top of insulation is usually 65mm but you can get pumped screed which will go down the 35mm so you get a faster warm up time.
      With the pipe at 200mm you should be able to heat the room easily enough but placing the pipe at 150mm gives you a more rapid warm up.
      If you are tiling make sure you leave an expansion gap around the perimeter and use flexible adhesive.

    • @robertcole7500
      @robertcole7500 Рік тому

      @@SkillBuilder Thanks for the detailed advice, much appreciated.
      Robert

  • @chrissanders55
    @chrissanders55 Рік тому

    We have suspended floors downstairs and we are going to add wet UFH. We are going to insulate between the joists. Is there a "best system" for this set up? Looked at various options and not sure which to go for.

    • @PercyJackson93
      @PercyJackson93 7 місяців тому

      Have you done this yet? What did you go for? The best method I see is to buy the insulation with foil either side. It's very firm so you cut with a saw to size and force in-between the joists to hold it in place. Personally I just used some garden netting, a Staple gun and a roll of fibreglass insulation but it was a bit of a hassle. I hope it's strong enough for over the years as well

    • @chrissanders55
      @chrissanders55 7 місяців тому +1

      @@PercyJackson93in the end I went for the overlay system downstairs from Ambiente (Ambisolo) and insulated between the joists underneath. I would have gone for something between the joists but we had a few sections (old house) of concrete floor that would have been too costly to dig out. Will do a between the joists the system upstairs. Happy Christmas!

  • @CrazyAIArt
    @CrazyAIArt Рік тому +1

    I had my solid floor milled from a company calked infloheat works wonders. No build up floors warm house warm bills lowered.

    • @SkillBuilder
      @SkillBuilder  Рік тому

      How much heat are you losing through the slab?

    • @CrazyAIArt
      @CrazyAIArt Рік тому

      @@SkillBuilder None its insulated underneath cant be losing that much as ive had to set the blender valve to 45 and even my boiler stats at about 60 degrees. The slab heats up amazingly befor we tiled.

  • @Jules_Pew
    @Jules_Pew Рік тому +14

    decent slippers are cheaper to run

  • @ogfeen
    @ogfeen Рік тому

    Hi Rodger. Love your videos.
    Do you need a concrete subfloor under your insulation?

    • @SkillBuilder
      @SkillBuilder  Рік тому +1

      No but the insulation has to sit on something. What are you planning to do?

    • @ogfeen
      @ogfeen Рік тому

      @@SkillBuilder renovation, old stone house. wacked in gravel in layers 70-100mm total depth, have allowed for 150mm insulation and 75 screed maybe incl mesh. Someone said sub floor so have put the job on hold. Would have to take out stone to get sub floor in.

  • @Haken00
    @Haken00 Рік тому

    Hi. I am considering underfloor heating for my flat - from what I have read so far is that the electric UFH is not very efficient in heating up the rooms so would like to go for wet / gas UFH. The lowest UFH systems on the market seem to be around 2cm thick - but was wondering about the insulation required. Based on this video it seems to me that insulation of around 4mm is pretty much useless and something much thicker is required (around 100mm) - is that right? Did someone install UFH (in a flat with concrete floorings) with insulation of only 4mm or so - and was it a good choice? In terms of room temperature and heating costs? Keen to hear your opinions.

    • @SkillBuilder
      @SkillBuilder  Рік тому +1

      Hi Haken
      I have done a few jobs straight onto uninsulated concrete and there is no doubt you lose heat. The key thing is that the pipe is near the surface so you get a fast warm up time. This means you can turn it on and off at will but there is no thermal mass to even out the heat.
      I would love to do some tests to find out how much is being lost through the floor but it is hard to do. I will think about some test rigs but the bottom line is that people are willing to lose a fair bit of heat in order to get the warm floor.
      You are right about electric, it is crap.

    • @Haken00
      @Haken00 Рік тому

      @@SkillBuilder Thank you for fast response - need to do some thinking in the upcoming weeks, would be great if you could do some tests too - though appreciate it's not straightforward to quantify how much heat is being lost when uninsulated.

    • @Haken00
      @Haken00 Рік тому

      @@SkillBuilder I just spoke to a representative of an underfloor heating company - he told me that concrete is actually quite a good insulator in some cases (in my case particularly it's a flat on 1st floor - with flats above and below me) - and apparently the heat loss through concrete is only about 6-8% so not that bad. Am wondering what your thoughts are on that - as I cannot afford 10cm insulation, probably not even 3cm, best I could do is something like 1cm so am wondering if UFH in such case is something worth doing.

    • @seanduffy2214
      @seanduffy2214 Місяць тому

      ​@@SkillBuilder I have a holiday chalet with no gas. We installed electric UFH throughout, insulation between the joists (although that is nowhere near perfect, think badly fitting jigsaw puzzle), Amtico on top (7mm dual overlay board in between which acts like the screed in spreading the heat) with tile in bathrooms and carpet in bedroom.
      A really good stable comfortable temperature and very comparable on cost to run compared to other standard electric heating.
      We get lots of positive comments about it when people stay in the depths of winter.
      Yes,😅 it's expensive compared to gas but that wasn't an option. It's also cheap to install and no floor build up either. We did have to upgrade some electrics as we have 2x10kw showers so the power draw with 2 showers and the UFH is too much so it temporarily flicks off the UFH but that is constantly on and off anyway to avoid going past 27 degrees floor temp.
      It takes time to warm up from cold like traditional UFH so we just leave it on a target temperature of 21 between 7am and 10pm and the thermostats in each room do the rest.
      People over the road also installed it after seeing ours but cut corners. One thing we think makes a massive difference are these dual overlay boards - they just added cheap LVT on top of the electric mats. I think they looked at them and thought they were ridiculously expensive MDF but they do a great job at spreading the heat evenly

  • @twig3288
    @twig3288 3 місяці тому

    If you wanted to partition a room which has UFH how would you install the sole plate without risking damage to the UFH pipe?

    • @SkillBuilder
      @SkillBuilder  3 місяці тому

      stick it down with a polymer adhesive, it is amazing how well it sticks.

  • @AdydeAdy21
    @AdydeAdy21 Рік тому

    Hello sir,great channel
    I need an automatiozation for underfloor heating? Or it isnt neccesarly automatiozation.thank you

  • @keithianlocke
    @keithianlocke 7 місяців тому

    If your laying one of the low build options over existing floor, maybe think about giving the floor a couple of coats of thermal paint before laying.
    The paint allows the floor to "breath" but helps reflect the heat back up by not allowing the "air moistire" to transfer heat down into it.

    • @SkillBuilder
      @SkillBuilder  7 місяців тому

      I don't think you want a breathing floor. I think you need an effective vapour barrier.

    • @keithianlocke
      @keithianlocke 7 місяців тому

      @@SkillBuilder some of the kit companies just suggest a floor sealant. I meant thermal paint over the sealant. And thought with joists the vapour barrier was below the flooring surface, so for anyone laying over floor surface could use paint.
      Personally, on the solid floor option I would get in the scree router to cut channels to lay pipes flush, then a thin scree to even heat and lay flooring over. On joists, insulation between (if ground floor), then the ufh panels that bridge joists with a flooring layer attached on top.

  • @SouthCoastFinest
    @SouthCoastFinest 3 місяці тому

    I'm looking at possibly installing UFH heating in my 1950's concrete floored bungalow. I've watched LOTS of UA-cam videos regarding the suitability of retro fitting it to my house and to be honest I am still none the wiser. There are so much conflicting information from separate sources, on this video it states that the heat loss will be substantial on a existing concrete floor whereas a company called Nu-Heat state that and non insulated concrete floor will only have 6% heat loss.
    I don't want to spend a fortune on UFH just to get nice warm floors only, I want it to be able to efficiently and effectively warm and maintain a comfortable room temperature.

  • @tsw4437
    @tsw4437 Рік тому

    Hello
    I am in process of installing water underfloor heating. As part of the project the engineer is also moving the boiler from kichen to garage.
    My question is when the project completed what kind of certificate and documentation should I get for the underfloor heating installation and for moving the boiler for my future record.
    Can you please list out what should I get from the company on completion please.
    Thanks,

    • @SkillBuilder
      @SkillBuilder  Рік тому +1

      Take photographs of the heating at every stage. You can also request an invoice with the name of pipe manufacutrer because they give a very long guarantee on the pipe.
      When the boiler is signed off you will have a log book with the details of the installer and the readings taken of the flue emmissions. It should also be registered through the installers registration. They can do this with their phone.

    • @tsw4437
      @tsw4437 Рік тому

      Thanks for your response

  • @Clark-Mills
    @Clark-Mills Рік тому

    Coffee! (And thanks!)

  • @Orchardman53
    @Orchardman53 Рік тому +14

    I suspect the people who don't like underfloor heating are those who've never experienced a properly installed underfloor system in a home.

    • @thomasschafer7268
      @thomasschafer7268 Рік тому

      Dümmste Antwort ever

    • @Orchardman53
      @Orchardman53 Рік тому +7

      @@thomasschafer7268 Ah, so you have cold feet on this matter.

    • @Orchardman53
      @Orchardman53 Рік тому +1

      @@Gordon.. I look forward to your UA-cam video explaining those issues. 😉 Do send me a link when you're ready.

    • @egocd
      @egocd Рік тому +1

      I'd say the same about heat pumps, but I don't want to trigger Roger ;)

    • @sailingoctopus1
      @sailingoctopus1 Рік тому

      My parents had underfloor heating installed in their new build 68 years ago and I've never wanted anything else. Far higher level of comfort than convection radiators and very efficient.

  • @maurifederi5817
    @maurifederi5817 Рік тому

    Hi. Is it posible to heat shower floor? And all bathroom?

    • @SkillBuilder
      @SkillBuilder  Рік тому

      yes it is very common to do that so it dries the shower out and prevents mould

    • @maurifederi5817
      @maurifederi5817 Рік тому

      @@SkillBuilder thanks. I need to think at any technical issue? Dilatation? Water tube distance away from main shower tubes?

    • @maurifederi5817
      @maurifederi5817 Рік тому

      I meant shower main drain pipe

  • @SteveAndAlexBuild
    @SteveAndAlexBuild Рік тому +8

    Our Friends had a burst bath tap in their bathroom a few years back . When the ceiling eventually caved in you could see a radiator in the middle of the room notched into the floor joists 🙄😳🤣🧱👍🏽

    • @SkillBuilder
      @SkillBuilder  Рік тому +6

      What a great idea. That will be my next video

    • @SteveAndAlexBuild
      @SteveAndAlexBuild Рік тому +1

      @@SkillBuilder 🤣🤣🧱👍🏽

    • @42RHD
      @42RHD Рік тому +1

      What, they'd just stuck a radiator under the floor?
      Genius! :))

    • @SteveAndAlexBuild
      @SteveAndAlexBuild Рік тому +1

      @@42RHD Yep 🤪🤣

    • @42RHD
      @42RHD Рік тому +1

      @@SteveAndAlexBuild Hilarious!

  • @philipdurling1964
    @philipdurling1964 Рік тому +1

    Underfloor heating shouldn't be used as a stand alone system but, ideally, part of an overall integrated system with good insulation and double/triple glazed windows. Also look for alternatives to a gas boiler as underfloor heating works at a lower temperature and is more efficient if installed correctly.

    • @davidianwalsh
      @davidianwalsh Рік тому +4

      My underfloor heating (Nu-Heat) runs off a thermal store of 750ltr, if heating is needed the u/f water is pumped through a heat exchanger in the thermal store and the boiler only kicks in once the TS has dropped a significant amount. This then economically utilises the oil fired condensing boiler as it’s not cycling on and off constantly

    • @philipdurling1964
      @philipdurling1964 Рік тому

      @@davidianwalsh Thanks for the heads up.

    • @deeeirl
      @deeeirl Рік тому

      @@davidianwalsh I'm looking at a similar setup with an oil boiler also, thanks for the info!

  • @xxwookey
    @xxwookey 6 місяців тому

    Lots of sensible advice here. I too think those skinny panels with 4mm of insulation between pipe and concrete are not very clever. You didn't mention that you don't have to have a slow-response screeded system over insulation. You can have a faster one. E.g lithotherm floor panels with the pipe in, or cellecta screedboard/hi-deck with the pipe underneath. Quicker and cleaner to lay and much lower-carbon. lithotherm: ua-cam.com/video/Fb7VvOFV3JE/v-deo.html screedbpoard: ua-cam.com/video/ZEVvwK9X6hA/v-deo.html
    I do wish there were easier ways to quantify the differences between these systems. It's hard to say exactly how much difference these things make.

  • @rogerwhiting9310
    @rogerwhiting9310 Рік тому

    The idea of having a hot radiator and a warm floor seems to defeat the energy savings of not having to put a lot of heat into water. As the temperature of the water rises it costs more energy per unit of heat to add. If you can keep your boiler at a MAX of say 48C and the return water maybe 10 degrees less...and adjust for outdoor temp...you should save some significant energy. It is SO expensive to drive 90C into water to make a radiator capable of heating a room.

  • @NottsPlumber
    @NottsPlumber Рік тому +2

    Thanks for the video👍🏻
    1:24 what is this guy actually doing?
    🤔

    • @SkillBuilder
      @SkillBuilder  Рік тому +2

      Absoloutely nothing, I really don't understand the video clips. If you watch the British Gas adverts it is the same, some guy pretending to fix something.

    • @42RHD
      @42RHD Рік тому +1

      And why does he have a hard hat in a luxury bathroom? These stock footage producers really need to up their game. I can see why they liven up a video though.

    • @rodgerq
      @rodgerq Рік тому +1

      Clearly he's confirming to a customer that this is in fact a towel rail and pointing to it it's position so as to avert any future confusion on the issue.

  • @adrianred236
    @adrianred236 3 місяці тому

    You definately need some thermal break under the pipes. I put UFH in a new build 20 years ago with 40mm PIR under it and never had a problem heating the whole rooms. 100mm is overkill IMHO, heat rises after all.

    • @SkillBuilder
      @SkillBuilder  3 місяці тому +1

      Heat rises in air through convection but in a solid floor we are talking about conduction which is happy in any direction.

  • @andycrask3531
    @andycrask3531 Рік тому +2

    Why do I get the feeling Roger has subscribed to a stock video website:p

    • @CaptainD1990
      @CaptainD1990 Рік тому

      lol'd

    • @SkillBuilder
      @SkillBuilder  Рік тому +7

      The edit is not my job, it is way above my capabilities. I am merely the mouth on a stick.

    • @gwynmorris5852
      @gwynmorris5852 Рік тому +1

      @@SkillBuilder 'mouth on a stick' : That's the important bit.. keep going.

    • @42RHD
      @42RHD Рік тому

      Yeah, I don't think those trees look very Surrey either.

  • @newbeginnings8566
    @newbeginnings8566 Рік тому +1

    Unless you add about 30cm of interlocking, sealed high density insulation then don't bother... Then the pipes are covered by poured, liquid concrete...
    Needless to say it all must be professionally installed by a highly reputable firm..
    But when down correctly the comfort is epic..

    • @SkillBuilder
      @SkillBuilder  Рік тому +1

      There are many way of doing this job and it is certainly a DIY job if you follow the instructions.

  • @randomcamerajunk6977
    @randomcamerajunk6977 Рік тому +1

    Here's the problem with mass market ufh. A 'normal' system runs at a fixed temp designed to heat your house when it's -2 outside. It will overheat the floor 90% of the year. They add wall thermostats to mitigate this. The smart engineers are running weather compensated mixers and no thermostats. And then we have engineers that don't understand the difference between dt20 and dt5 and tee the UFH off a rad circuit and wonder why the rads stop working when the UFH is on. Basically ufh is mosty misunderstood by both customers and plumbers.

    • @SkillBuilder
      @SkillBuilder  Рік тому +1

      I think you might be right about all that. Interesting ideas and Heat Geeks doing away with manifolds altogether which makes sense if you are running a boiler or heat pump at 50 deg C

    • @LocostR1
      @LocostR1 Рік тому +2

      Yep we have low build UFH across our ground floor (the EPS boards Roger was laying at 5:12), originally with a static mixer on the manifold and "dumb" smart controls on the (Vaillant) boiler constantly pumping out 70c flow temperatures relying on the manifold mixer to try and keep it down around 35-40c. We've now ditched the mixing valve on the manifold and swapped out the controls for Vaillant weather comp controls along with 2 Esbe electronic mixing valves managed by the Vaillant controls (installed by Andrew Millward, there's a video on his page of our install). That means we can run 2 separate weather compensated curves for the two heating circuits, one between about 20c and 40c for the UFH, the other that has a wider operating temperature range up to about 55c for the upstairs rads.
      As an aside Roger, I'm not sure low build UFH necessarily needs rads for quick response in most instances, because the pipes are right under the floor surface its warm within 20 minutes from the boiler coming on unlike conventional UFH, which raises room temps almost as quickly as rads in our case, even with ~30c flow temps.

    • @randomcamerajunk6977
      @randomcamerajunk6977 Рік тому +1

      @@LocostR1 nice 🤘 we're militant Viessmann disciples just like Andrew and I wouldn't entertain fitting ufh without an electronic mixer. Fixed temp seems absolutely absurd to me.

    • @LocostR1
      @LocostR1 Рік тому

      @@randomcamerajunk6977 If I knew 2 years ago what I knew now I probably would have had Andrew in to install a Veissmann with this kind of setup from the off, much better modulation from what I understand and the controls look far more logical and easy to use than Vaillant.

    • @lauriviik
      @lauriviik Рік тому

      Thats just stupid argument. Need to have mixer with thermostats. How do you control different room temperatures seperatly if not using thermostat. Not very smart to constantly adjust flow speed manually from manifold.

  • @TeddyBBB
    @TeddyBBB Рік тому

    What is bad about electric underfloor heating?

    • @elslopez
      @elslopez Рік тому +11

      The cost of running it!

    • @SkillBuilder
      @SkillBuilder  Рік тому +7

      It is not really suited to heating a room to 21 deg. It is fine for tile warm up. My neighbour three doors down had it even though I advised him to have hydronic. He ran it for one winter and it was £1,000 for the kitchen and dining area only. After that he switched it off and put some radiators in.

    • @lauriviik
      @lauriviik Рік тому

      Doing same work, but instead of installing wire, better to install pipes. Wire only works with direct electricity, pipes can have more options. You can heat pipes with stight electricity but later upgrade it to gas or heatpump also.

  • @walihangbantwa9014
    @walihangbantwa9014 Рік тому

    Wouldn't these pipes collect moisture from the cold air touching their outer surface, and later could ruin the floor ??

  • @TC-V8
    @TC-V8 Рік тому +2

    Looking at fitting underfloor heating down stairs, im slowly coming to terms that the concrete floor screed will need coming up to do it properly!

    • @leejames7964
      @leejames7964 Рік тому +1

      No it doesnt you can get whats called a retro fit kit that goes on top of your current screed. It uses panels and the pipes click into it and then you fill the left over gaps with the filler that comes with the kit then put self leveling compound raises floor level by 22mm

    • @sailingoctopus1
      @sailingoctopus1 Рік тому +1

      @@leejames7964 But as Roger says, you will lose some heat through the ground. Much better to break up the existing concrete, dig down sufficiently to put 100mm of insulation, then lay your UFH pipes in a 50mm of concrete. It is disruptive,but it's worth it long-term.

  • @barryferguson6219
    @barryferguson6219 Рік тому

    The only item you missed when talking about the sensible thing to do is to also consider a heat pump alongside underfloor heating. Come on Rodger even you can't argue toss on that! Surely you can't do a video on underfloor heating and not talk at some point about the advantages of a low temperature heat source connected to it.

    • @handle1196
      @handle1196 Рік тому

      This can be done equally as good using a high modulating gas boiler like a viessmann 200 and weather compensation sensor. They are 3x cheaper to buy and almost identical to run. Heat pump has the edge but takes 20 years to make the saving back.

    • @barryferguson6219
      @barryferguson6219 Рік тому +1

      @@handle1196 Yet to hear anyone come up with a gas boiler that produces less carbon output per kw of heat than a heat pump, that's where the real conversation is. The current energy & environmental crisis is not down to the cost of renewable energy or its carbon footprint it's a fossil fuel crisis. The solution is not more of the same problem. My point wasn't that heat pumps should be the answer to everything but surely a video talking about a low temperature heating system basically designed for a heat pump needs to at least acknowledge them.

    • @handle1196
      @handle1196 Рік тому

      @@barryferguson6219 i don't think anyone wouldnt want to go for the greener option, it just has to be more appealing than the fossil fuel option. Cost of living is through the roof and not just with energy if they drop them prices over night, so people will always choose the cheapest option. A heat pump needs to cost half as much to purchase i think.

    • @SkillBuilder
      @SkillBuilder  Рік тому +3

      Barry
      I actually did talk about heat pumps in this video and the fact that they don't work well if you switch them on and off but we cut it out because it was straying off the topic and a lot of people would see me as a stuck record. If you make videos for UA-cam it is always a job to keep them tight.
      Low temperature heating can be done with any heating appliance but a gas boiler is way more responsive to the great variations we get in temperature. The carbon issue is important but really we need better technology before we kick out gas. They are already warning of possible power cuts in January so the last thing we need is more people drawing off the National Grid.

    • @42RHD
      @42RHD Рік тому

      There is nothing sensible about Heat pumps.

  • @CaptainD1990
    @CaptainD1990 Рік тому

    I thought heat loss via uninsulated floors is 10%? If I'm right, the savings on not insulating in the first place will cover the first ~20 years of increased running costs..

    • @SkillBuilder
      @SkillBuilder  Рік тому +4

      I am not sure that the 10% holds true for placing heating pipes on a cold concrete floor but I could be wrong

    • @johnnyfandango1625
      @johnnyfandango1625 Рік тому +1

      I'm not sure where this figure of 10% comes from? Urban myth more like and one that a few underfloor suppliers like to tell customers to get sales. I would say it is more like 20% heat loss through the floor when heating up an uninsulated slab. If anyone can come along with some science to say otherwise I'm all ears!

    • @deeeirl
      @deeeirl Рік тому

      Apparently 80% of the heat lost through the slab is lost at the side wall footing. It's the reason that the footings are insulated all the way down when doing EWI properly.

  • @keithrimmer3
    @keithrimmer3 Рік тому +1

    Cost a bloody fortune in gas bills for underfloor heating you need an outside large wood gasification boiler, forget gas and electricity ask me how I know the ground floor area is 38 feet x27 plus 4 rads upstairs winter bills are £600 summer 180 ish 20 years ago it was £60 a month in winter, the Froling s30 is the one to get

    • @LocostR1
      @LocostR1 Рік тому +8

      What a load of tosh. You wouldn't have a vested interest in wood gasification boilers would you Keith Rimmer formerly of Ecopod biomass boilers I assume? :)

    • @keithrimmer3
      @keithrimmer3 Рік тому

      @@LocostR1 No mate I just changed the gas boiler to wood-fired and saved a fortune in gas bills in an old stone coach house with flag floors and draughty old leaded windows

    • @LocostR1
      @LocostR1 Рік тому

      You'd hope to save a bit on the gas bill with a wood fired boiler 👍

  • @johneod1250
    @johneod1250 Рік тому

    nicht wirklich ein fachmann

  • @eddjordan2399
    @eddjordan2399 Рік тому +1

    legend

  • @thomasschafer7268
    @thomasschafer7268 Рік тому

    Träge. Und kalte Böden gibts nur in alten Häusern.

    • @SkillBuilder
      @SkillBuilder  Рік тому +2

      Ich stimme nicht zu, selbst mit Isolierung ist die Betonplatte kalt.