Complete wiring | Automatic changeover switch (ATS) | single phase | Grid to Solar.

Поділитися
Вставка
  • Опубліковано 2 жов 2024
  • This video is a demonstration of a step-by-step process to wire a complete single-phase Automatic changeover switch from scratch to finish. Every bit of the wiring has been explained in detail, so even non-electricians can clearly understand. • house wiring materials...
    Note: For real-life application, consult a qualified electrician for the correct size of contactors and cables to use for the internal wiring, to suit your specific application
    kindly click on the links below to watch my other videos on changeover switches
    • STAR DELTA CONNECTION
    • AUTOMATIC TRANSFER SWITCH
    • SOLAR SETUP FOR HOME |...
    • solar pump installatio...
    • AUTOMATIC TRANSFER SWI...
    • THREE PHASE CHANGEOVER...
    • #1 Contactors explaine...
    • HOW TO WIRE AN 8PIN TI...
    • HOW TO WIRE A TIMER TO...
    • how to connect 3phase ...
    • Forward and reverse mo...
    • 3phase motor winding c...
    • How to check for open ...
    • HOW TO WIRE D.O.L STAR...
    • Mastering Contactors: ...
    • 1 Photo sensor +1 Cont...
    • How to check a faulty ...
    • HOW TO WIRE A TIMER TO...
    • HOW TO WIRE AN 8PIN TI...
    • DIFFERENT TYPES OF ELE...

КОМЕНТАРІ • 89

  • @Simply2sureOdds
    @Simply2sureOdds Рік тому +3

    Very educative 😊. Thank you for your simplified explanations.

  • @giftmofolo9487
    @giftmofolo9487 10 місяців тому +1

    Me and my class we are proud of you sir we have made it❤

    • @obloni_Electrical
      @obloni_Electrical  10 місяців тому

      Wow! That's great to hear. From which country please?

  • @danielteyehuago1633
    @danielteyehuago1633 11 місяців тому +1

    Well done, but having a rough sketch of the diagram and adjusting the camera angle will have been of a great help to us.

  • @dylanthomasprowse880
    @dylanthomasprowse880 7 місяців тому +1

    excellent video, very good

  • @Black74c
    @Black74c 11 місяців тому +2

    Informative....Why are the mains supply cables for solar and Grid connected at the down terminals of the earth leakage . Kindly explain

  • @kayitamoses8580
    @kayitamoses8580 6 місяців тому +1

    I am going to apply the very same controls for a 3-phase circuit

  • @royakalah181
    @royakalah181 6 місяців тому +1

    Very clear explanation - you didnt mention function of the MCB

    • @obloni_Electrical
      @obloni_Electrical  6 місяців тому

      Don't worry dear, everything you need to know about that is here use this link: ua-cam.com/video/EDl-Vapdm5M/v-deo.html

  • @JonasKwesi
    @JonasKwesi 28 днів тому

    But please can you use this arrangement for generator and grid

  • @IkechukwuNwankwo-og2lx
    @IkechukwuNwankwo-og2lx 9 днів тому +1

    Thanks for the video
    But is there anything like timer in your circuit?

    • @obloni_Electrical
      @obloni_Electrical  9 днів тому

      Please check this other video with timers ua-cam.com/video/49OSOdSPgfo/v-deo.htmlsi=drn-b4AQwOJcHBDw

  • @gowthampavanaskar1889
    @gowthampavanaskar1889 3 місяці тому +1

    On this example are you using two different power supplies or uaing the same power supply split into solar and grid?

    • @obloni_Electrical
      @obloni_Electrical  3 місяці тому +1

      I used two different phases. L1 and L2, to represent Grid and Solar respectively.

    • @obloni_Electrical
      @obloni_Electrical  2 місяці тому

      @@gowthampavanaskar1889
      I used Two different phases.

  • @jcelectrotorial9603
    @jcelectrotorial9603 7 днів тому

    I think much better if you provide the schematic diagram of your work, so that all of us can get easily the connections

  • @carl78052
    @carl78052 2 місяці тому +1

    Whats the use of single pole breaker?

    • @obloni_Electrical
      @obloni_Electrical  2 місяці тому

      @@carl78052
      ua-cam.com/video/EDl-Vapdm5M/v-deo.htmlsi=03__xTgOIxxf-snv
      Please use the link above for thorough explanation to your question. Thanks

  • @hundew
    @hundew 27 днів тому

    Hello, Is not a problem when the solar power is active, but the grid came back, and energise the contactor's coil, so the grid contactor going to closed state, but for few milliseconds, the solar contactor still closed, before the auxillary contact going to open it?

  • @luckychidi9777
    @luckychidi9777 8 місяців тому +1

    very impressive and educative, pls what about a connection when relay in involved in this kind of connection
    pls i would love to balance this

  • @romeosecretaria6968
    @romeosecretaria6968 7 місяців тому +2

    Its a nice demonstration and explanation. But for lighting load only, it can be done by using relays which are cheaper and lesser power consumption on magnetic coils.

    • @obloni_Electrical
      @obloni_Electrical  7 місяців тому +1

      Thanks Romeo. I only used the lamps to represent the load in the wiring. It doesn't mean it is only meant for lighting load. Thanks 👍

    • @romeosecretaria6968
      @romeosecretaria6968 7 місяців тому +3

      But i still like your discussion. But next time, kindly use materials relative to the load you are demonstrating. Or mention the load that the circuitry capability to carry on.thanks

    • @obloni_Electrical
      @obloni_Electrical  7 місяців тому +2

      Well noted thanks. @@romeosecretaria6968

  • @batjiyasanthos5526
    @batjiyasanthos5526 9 місяців тому +1

    Simple and informative. Thank you 👍

  • @mulandomulilambonge9124
    @mulandomulilambonge9124 6 місяців тому +1

    Very good demonstration.

  • @patricknjau3060
    @patricknjau3060 Місяць тому +1

    Thanks

  • @danielteyehuago1633
    @danielteyehuago1633 16 днів тому

    Please where can I get these types of contactors to buy. I want to be practicing it with your videos.

    • @obloni_Electrical
      @obloni_Electrical  11 днів тому

      @@danielteyehuago1633 please contact me on WhatsApp. +233209323669

  • @Sd_phase
    @Sd_phase Рік тому +1

    Thank you for the good explanation, look forward for the new video ❤️

  • @multiskilledelectrician1
    @multiskilledelectrician1 4 місяці тому

    Thank you for sharing. Is the device placed on Grid contactor timer or what?

  • @danielteyehuago1633
    @danielteyehuago1633 9 місяців тому +1

    This video has weight. I am back again

  • @RichmondAdu-NtowKwadwo
    @RichmondAdu-NtowKwadwo 10 днів тому

    Please how was your MCB connected to the RCD ???

    • @obloni_Electrical
      @obloni_Electrical  10 днів тому

      Full explanation to your question is here ua-cam.com/video/EDl-Vapdm5M/v-deo.htmlsi=43JgYk154q2dHqrp
      ua-cam.com/video/s1dP9xth6KY/v-deo.htmlsi=jUt8kF8oy6K7s3OK

  • @BonifaceChunda
    @BonifaceChunda Місяць тому +1

    Provide the circuit diagram please sir.....
    I love it.....

    • @obloni_Electrical
      @obloni_Electrical  Місяць тому

      @@BonifaceChunda please kindly contact me on WhatsApp +233209323669 if you need the diagram. Thanks

  • @solomonkipsi3762
    @solomonkipsi3762 9 місяців тому +1

    Great explanation 💗

  • @antoniorodriguezperico
    @antoniorodriguezperico Рік тому +1

    Diagram please! Thank you

    • @obloni_Electrical
      @obloni_Electrical  Рік тому

      Noted . I will try to include diagrams in the subsequent videos. Thanks

  • @KariIru-li8xu
    @KariIru-li8xu Рік тому +1

    Please need a wiring diagram. Ta

  • @jessew6757
    @jessew6757 4 місяці тому

    Do you have a schematic for this sir ?

  • @MosesChanda-eh2of
    @MosesChanda-eh2of 5 місяців тому

    Please help me how to wire a hammer mill with a 24 HP circuit

    • @obloni_Electrical
      @obloni_Electrical  5 місяців тому

      Please kindly come clearer on how you want me to help you. For 24Hp you may have to use Star delta starter. You can watch this video for more explanation on the star delta wiring.
      ua-cam.com/video/zIJ66ZRrJQo/v-deo.htmlsi=if2DogaCzdMtn-du

    • @MosesChanda-eh2of
      @MosesChanda-eh2of 5 місяців тому

      @@obloni_Electrical yes using star delta

    • @MosesChanda-eh2of
      @MosesChanda-eh2of 5 місяців тому

      I mean the whole circuit inclusive using stop and start buttons and timers together with loverload relay. It would mean a lot to me thank you

  • @isausmanaudu6351
    @isausmanaudu6351 3 місяці тому

    Very well explanation but sir for the NC you said to solar coil you didn't mention which terminal thank you

  • @manudesmond1680
    @manudesmond1680 Рік тому +1

    Pls sir, what if I am using generator instead of solar panel, can I go by the same principle. Thank you.

    • @travismailsa1
      @travismailsa1 Рік тому

      I think you can, but you will have a power dip if you do not have an inverter before you either manually start your generator or for the ATS to start the generator.
      Normally with generators a solenoid based changeover switch is used.

    • @manudesmond1680
      @manudesmond1680 Рік тому

      @@travismailsa1
      Pls I don't get it well, can you please give me further explanation. Thank you 💕

  • @thousiffg7393
    @thousiffg7393 9 місяців тому +1

    Can we do it with two pole contactor

    • @obloni_Electrical
      @obloni_Electrical  9 місяців тому

      Sure! if it's rated high enough to take the load.

  • @danielteyehuago1633
    @danielteyehuago1633 9 місяців тому +1

    This video I rate it 🌟🌟🌟🌟🌟

  • @NanaYawSafo-r4k
    @NanaYawSafo-r4k Рік тому +1

    Great! keep it up bro.

  • @Kodjoedem
    @Kodjoedem 5 місяців тому

    If you want to add a 3rd power source say gen. If the solar power runs out, does it mean you wire the contactor of the generator as secondary to the solar where you place an aux NC contactor and run the live through it before it goes to A1/2?

    • @obloni_Electrical
      @obloni_Electrical  5 місяців тому +1

      That will require a very different arrangement. I will show it in a subsequent video. Thanks

  • @Black74c
    @Black74c Рік тому

    What happens in an event of a faulty contactor ?

    • @obloni_Electrical
      @obloni_Electrical  Рік тому +2

      As a result of bad Coil, the contactor Will not close.
      As a result of a bad contact, the contactor Will close but there will not be out put power.

  • @biggiekasimba2972
    @biggiekasimba2972 Рік тому +1

    Hundreds

  • @thousiffg7393
    @thousiffg7393 9 місяців тому +1

    Can we do this without rcb

    • @obloni_Electrical
      @obloni_Electrical  9 місяців тому +1

      Oh yes!

    • @thousiffg7393
      @thousiffg7393 9 місяців тому

      I done without rcb but my inverter burnt

    • @obloni_Electrical
      @obloni_Electrical  9 місяців тому +1

      @@thousiffg7393
      Oh no! Something was probably not done right.
      But please, did you test the changeover setup before hooking it up?

    • @danielteyehuago1633
      @danielteyehuago1633 9 місяців тому

      ​@@thousiffg7393Please which auxiliary contact did you use. Because the auxiliary contact used on the grid contactor was NC

    • @MasausoNgulube-b9e
      @MasausoNgulube-b9e 4 місяці тому

      Noticed that the breaker is not switched on or off in the circuit

  • @manudesmond1680
    @manudesmond1680 Рік тому

    Pls sir, what if I am using generator instead of solar panel, can I go by the same principle. Thank you.

  • @danielteyehuago1633
    @danielteyehuago1633 11 місяців тому

    Please this is a good tutorial, can you redo it with detailed diagram and good camera angle. Thanks

  • @VemuriRakeshRakesh
    @VemuriRakeshRakesh 7 місяців тому +2

    Looking good . Please provide drawing as connections are not understanding

  • @MasausoNgulube-b9e
    @MasausoNgulube-b9e 4 місяці тому +1

    The breaker is not switched on or off why ,😮 did anyone notice

    • @obloni_Electrical
      @obloni_Electrical  4 місяці тому

      Yes, that mcb was intentionally placed there to let you that anytime you are wiring RCDs there must also be an mcb. The other one is an RCBO so it can work alone. Please watch these videos to be guided.
      ua-cam.com/video/s1dP9xth6KY/v-deo.htmlsi=s4bGxpv_Sp5JRL9k
      ua-cam.com/video/EDl-Vapdm5M/v-deo.htmlsi=6TQYZgWn4wIjeKSJ
      ua-cam.com/video/yAxkPvMb-7E/v-deo.htmlsi=i2-O9lOykfwibT3d
      ua-cam.com/video/MhdUZ7wOEPw/v-deo.htmlsi=ikg-wRbN3EzbrjIy
      ua-cam.com/video/HeRdarYcoIQ/v-deo.htmlsi=eY4wRP2fNCmADMMn

  • @Ibrahimsaheed-bn2ph
    @Ibrahimsaheed-bn2ph Рік тому

    Very well explained but I have a question to ask sir,My question is that what's the work of the single mcb beside the double pole RCB of Solar grid ? Where does the output of that mcb connected to ? Secondly why the input for Solar and Grid are not the same T1&T2 I mean colour and Terminal interchange, Lastly can you please drop your WhatsApp number for more experience and have access to your status.Thank you sir

    • @obloni_Electrical
      @obloni_Electrical  Рік тому +1

      1. please watch these videos
      ua-cam.com/video/EDl-Vapdm5M/v-deo.html
      ua-cam.com/video/yAxkPvMb-7E/v-deo.html to clearly understand why I used the single-pole mcb with the RCCB.
      2. connecting the Live & Neutral cables of the grid and solar to different terminals T1 & T2 doesn't matter. What matters is the connection at the output side of the contactor (L1 & L2), to ensure that the
      Live and Neutral from the grid aligns correctly with the Live and Neutral from the Solar supply.
      3. WhatsApp +233242809918
      main channel: ua-cam.com/channels/WnOYQv9Jxsv6Ax9tip9OnA.html

    • @iambenqazy
      @iambenqazy Рік тому +1

      Thank you for the thorough explanation. Great video by the way 💯. Can you please share the layout diagram for this particular setup. I really like the mechanical interlock you did. Thanks in advance.