Exhaust Fan Motor Change...

Поділитися
Вставка
  • Опубліковано 23 гру 2024

КОМЕНТАРІ • 38

  • @davidmorales2891
    @davidmorales2891 7 років тому +17

    I would tell anyone who watches this video that shutting off the breaker at the panel and walking away without locking out and tagging the breaker is unsafe at any voltage, that breaker panel was in an open area accessible to anyone. Always secure the power source at the breaker so that only you can turn it back on when you are finished wiring your motor and are ready to restart.

    • @alanrojas550
      @alanrojas550 4 роки тому +1

      If you see the video completly you noticed that they have a service switch on in the unit for safety. But yeah way better if lock the breaker or panel.

  • @erikr6691
    @erikr6691 8 років тому +4

    Nice job. Glad to see I'm not the only one who needs ice skates on those rubber roofs.lol

    • @BillyKnoth
      @BillyKnoth  8 років тому

      Erik R they do suck man!!!

  • @tcphvacr9950
    @tcphvacr9950 7 років тому

    We have plenty of the Sarnifil white rubber roofs at my school, on wet or frosty mornings I walk on them like I'm on a frozen pond, lol! Like them better than the ones weighed down with rock, though. Looked like fun, just got to tear a side wall mounted fan apart the other day, it was full of straw and bird feathers. Looked pretty neat and clean when you were done.

  • @harrydejesus2975
    @harrydejesus2975 8 років тому

    Nice job BK. Good to see you doing your repairs. Cheers.

    • @BillyKnoth
      @BillyKnoth  8 років тому

      Harry Dejesus thanks man!

  • @Silky_boi
    @Silky_boi 4 роки тому

    Thank you so much! Boss sent me on a similar setup without any experience on this.

  • @hvaclifewithalex4051
    @hvaclifewithalex4051 8 років тому

    Great video Billy like always!

  • @20antman
    @20antman 8 років тому +1

    I noticed your line power wires were brown,orange,yellow. That is the standard color for 3 phase 460v. But i noticed you wired it up for 208/230v. 3 phase208/240v is black,blue,red. I know the color of the wire really does not have any effect on the voltage. Maybe the electrician used what ever wire they had at the time. I never seen that before though. Are you sure you had 208/240v being supplied to that motor? I am guessing you did.

    • @BillyKnoth
      @BillyKnoth  8 років тому +2

      Anthony Reardon hvacr good looking out man!...The fan use to be used with 440v....when it was in the old location...but whem it was moved the old motor was rewired for 208/230....but the existing wires from the switch in the fan stayed....Great observation!!!!!!!😁

  • @lucasjuan4500
    @lucasjuan4500 6 років тому +2

    How much cost for replacement this motor ?

  • @deanmclamb7751
    @deanmclamb7751 8 років тому

    Good job, I enjoy your videos!!

  • @justinjohnson2877
    @justinjohnson2877 8 років тому

    Nice job Billy.

    • @BillyKnoth
      @BillyKnoth  8 років тому

      Justin Johnson thanks !!!😁

  • @NorCal-refrigeration
    @NorCal-refrigeration 8 років тому +1

    Good video Billy. I slipped on my azz this week on white rubber roof lol. 😂

    • @BillyKnoth
      @BillyKnoth  8 років тому +1

      Dave....those roofs suck azz.....nothing like being near the edge and slipping...

  • @marcoalvarez1276
    @marcoalvarez1276 8 років тому

    Clean job bro!

    • @BillyKnoth
      @BillyKnoth  8 років тому

      Marco Alvarez thanks bro!

  • @jabesilixiouscastaneda804
    @jabesilixiouscastaneda804 5 років тому

    He should have a lock out tag on it so people are aware why the switch is off and for his own safety.

  • @youngrikhvac9919
    @youngrikhvac9919 8 років тому +1

    nice video.

  • @i_darrin_t_it5716
    @i_darrin_t_it5716 7 років тому +1

    That roof looks really familiar.

    • @BillyKnoth
      @BillyKnoth  7 років тому

      Where do you think it is?

    • @i_darrin_t_it5716
      @i_darrin_t_it5716 7 років тому

      BK HVAC Bolar / Circa. Spent a lot of springs and falls up there with Arty

    • @BillyKnoth
      @BillyKnoth  7 років тому

      Has not been circa since 2000...but yep thays the building

    • @i_darrin_t_it5716
      @i_darrin_t_it5716 7 років тому

      BK HVAC I moved in '99 so I didn't know it changed companies

    • @BillyKnoth
      @BillyKnoth  7 років тому

      2x so far....lol

  • @bnance0919
    @bnance0919 8 років тому

    Nice video

  • @jerelallera9185
    @jerelallera9185 7 років тому

    nice....

  • @HVACShopTalk
    @HVACShopTalk 8 років тому

    good video

    • @BillyKnoth
      @BillyKnoth  8 років тому

      Working Joes Roundtable thank you sir!

  • @bennycomptech3939
    @bennycomptech3939 8 років тому +1

    Largest motor I've ever worked on was 150HP

    • @BillyKnoth
      @BillyKnoth  8 років тому +1