Biggest mistake on construction site | Column Bar को सही करने का तरीका ?

Поділитися
Вставка
  • Опубліковано 16 гру 2019
  • 15 Mistake in House construction
    • 15 Biggest Mistakes du...
    15 Technical Term for civil Engineers
    • 15 Technical Every civ...
    Official Website Civil Site Visit
    civilsitevisit.com
    Daily New Job Links
    civilsitevisit.com/recruitment/
    WHATSAPP GROUP
    chat.whatsapp.com/BVZb2995QXA...
    chat.whatsapp.com/K83YQHVXxkd...
    chat.whatsapp.com/BPoi8iLL9fZ...
    ( TELEGRAM GROUP FOR CIVIL ENGINEERS )
    t.me/joinchat/i84Oy3K0wqgzMjU1
    t.me/joinchat/zwE9MYXIdgY5OWY1
    ( TELEGRAM GROUP FOR JOB UPDTAE )
    t.me/joinchat/AzzpD2BS3qhmZjZl
    ( OUR OTHER UA-cam CHANNEL )
    1. For Job Update
    / @civilsitevisitjobsupd...
    2. For Business Idea
    / @businesskaadda12
    3.Civil Engineer Sharma Ji ( Basic of civil Engineering )
    / @civilsitengineer
    4.Pareeksha ( Job & Exam Preparation )
    / @civilengineerintervie...
    10 Most watched Video of ( CIVIL SITE VISIT )
    1. Tile or marble Flooring
    • मार्बल लगाये या टाइल |...
    2.How to decrease construction cost of House
    • घर बनाते समय इन 5 बातो...
    3.Construction Cost of 1000 Sqft House
    • Construction cost of 1...
    4.Parapet Wall Cheap & Best Design
    • Parapet wall two Best ...
    5.Wall Dampness Treatment
    • Wall Dampness Treatmen...
    6.Marble or Tile Flooring
    • Marble or Tile ? which...
    7.Cracks in wall repair
    • घर की दीवारों में क्रे...
    8.Mistake in House Construction
    • घर बनाते समय इन 8 बातो...
    9.1000 sqft House Material Quantity
    • 1000 sqft का घर बनाने ...
    10.ACC Block Vs Red Brick
    • 1000 sqft का घर बनाने ...
    CONTACT DETAILS
    ✔Email Id for Business Enquiry - rs140565@gmail.com
    ✔Twitter: VisitCivil?s=09
    ✔Facebook Page: / 100041543491213
    ✔ LinkedIn: / rahul-sharma-66324a215
    ✔Instagram: / civil_site_visit
    ✔Tumblr: / civilsitevisit
    For Business Enquiry
    7006672812 (Note :- Only WhatsApp )
    Disclaimer - This video is for educational purpose only. Copyright
    Disclaimer Under Section 107 of the Copyright Act 1976, allowance is
    made for "fair use" for purposes such as criticism, comment, news
    reporting, teaching, scholarship, and research. Fair use is a use
    permitted by copyright statute that might otherwise be infringing.
    Non-profit, educational or personal use tips the balance in favor of
    fair use .
    #civilengineeringbasic #Practicaltraining #siteengineerTips

КОМЕНТАРІ • 202

  • @neerajyaduvanshi5661
    @neerajyaduvanshi5661 4 роки тому +3

    Mai already thik karwa chuka hu is mistake ko and thanx sir aapki video se mujhe bahut help milti hai ek video coasting P nikaliye puri details k sath sir pls

  • @ankitsingh-hg4cm
    @ankitsingh-hg4cm 4 роки тому

    Very very good sir
    Expecting more like this
    Thank you

  • @vaibhavchavan6040
    @vaibhavchavan6040 4 роки тому +5

    Thank u sir. very helpful video for site engineer.

  • @Iitgstr1
    @Iitgstr1 4 роки тому

    Nice information 👌 Brother, thanks

  • @abhishekgautam8185
    @abhishekgautam8185 4 роки тому +3

    Aap bahut axe se explain krte hain... Thnk u sir

    • @civilsitevisit
      @civilsitevisit  4 роки тому

      Thanks brother
      aese he dekhte raho sekhte raho n share plz ❤️

  • @fasttrendiz3411
    @fasttrendiz3411 3 роки тому +5

    Sir foundation colum 9*18 ka tha, 5 inch jaggal kiya h, dusre ki jagah m chala gya tha , coloum uspe plinth bim bhi dal diya, ab ky kre ,

  • @awaisahmad8935
    @awaisahmad8935 2 роки тому

    I learned best column correction method from this video, great job sir

  • @adarshallkindsgame8988
    @adarshallkindsgame8988 4 роки тому +1

    very important information Sir ji
    thanks

  • @ashutoshupadhyay5928
    @ashutoshupadhyay5928 4 роки тому +2

    Will you please let us know from which IS code or ASTM you are suggesting it

  • @sarthakmohapatra3738
    @sarthakmohapatra3738 4 роки тому

    Excellent video sir . Thnx a lot

  • @syedmahmood2372
    @syedmahmood2372 3 роки тому

    This video was really very helpful Sir

  • @mirsaif5795
    @mirsaif5795 2 роки тому +1

    Sahi video banaya Bhai tum ne....

  • @ramchandrashrivastava3639
    @ramchandrashrivastava3639 4 роки тому

    Very very useful video.

  • @neerajsahu18
    @neerajsahu18 3 роки тому

    Great ... Very useful video tqqq

  • @ShadabKhan-ls4rv
    @ShadabKhan-ls4rv 2 роки тому

    Sir you are doing great job

  • @dheerajshukla8902
    @dheerajshukla8902 4 роки тому

    Sr video editing k liye kon sa app or software use krte ho

  • @sunitaprasad2724
    @sunitaprasad2724 4 роки тому

    Very nice Sir Thank you so much

  • @adityajoundal8500
    @adityajoundal8500 Рік тому

    Knowledgeable Video sir

  • @mdreyazshaikh7241
    @mdreyazshaikh7241 4 роки тому +1

    Bahut achha sir jii

  • @AkashSharma-zt7xk
    @AkashSharma-zt7xk 4 роки тому +2

    Thank you sir

  • @dimalbarman4428
    @dimalbarman4428 4 роки тому

    Sir 24 by 30 fit building sat take Kitna tmt bar lagyga ,comment please.colmin air bim mein 16 and 12 tmt use karange

  • @mirsaif5795
    @mirsaif5795 2 роки тому

    Yeh kaisi thanks bolna samaj nahi Ara lekin bohat shukriya is video se kai sare logon ku bohat badi madad hogayee...

  • @priyankapanche8636
    @priyankapanche8636 Рік тому

    Best idea sir

  • @sonalibahuguna1945
    @sonalibahuguna1945 Рік тому +3

    Out of 16 columns, 5 Columne are misplaced by 2 to 5 inches.. plinth beam is already casted. What should be correction for this mistake ?

  • @simantakumardalai8189
    @simantakumardalai8189 4 роки тому +1

    Bahat achha

  • @CivilSiteadda10
    @CivilSiteadda10 4 роки тому

    Sir aap videos edit ke liye kon sa app use krte ho

  • @shouryabikashjena7834
    @shouryabikashjena7834 4 роки тому +2

    Sir agar aisa chhat banane ke baad hua to kya karu.....?please reply

  • @shahidiyasir4396
    @shahidiyasir4396 4 роки тому +1

    Bht Sahi...

  • @salimjave1834
    @salimjave1834 3 роки тому

    Best video sir

  • @upanshusharma7815
    @upanshusharma7815 4 роки тому

    Thankyou sir

  • @pranjalbaishya834
    @pranjalbaishya834 4 роки тому +1

    thnks vaai.. mere site pe hua tha yeh mistake.. shttrng ka spprt hil gaya tha.. column ka top 55 mm hil gaya tha... fir maine twist kara k thik kiya.. galat tha pata tha.. pr sahi tarika aaj malum para.. ab se fichr chmicl use karunga..thnkss buddy

  • @pramodtiwari9198
    @pramodtiwari9198 4 роки тому

    Kya ye tarika pwd,cpwd etc Mai manya hoga?

  • @zetchalama4112
    @zetchalama4112 3 роки тому

    Can same method be done if column mistakes in on first floor

  • @dhingranitish
    @dhingranitish 3 роки тому

    Nice content

  • @awaisahmad8935
    @awaisahmad8935 2 роки тому +2

    I faced this situation and corrected with the help of your video, thanks a lot sir, U r wonderful

  • @UmeshKumar-fm1qp
    @UmeshKumar-fm1qp 4 роки тому

    very good

  • @nitinpandharkar6646
    @nitinpandharkar6646 4 роки тому +3

    Good solution for such mistake in isolate foundation is to replace it with new foundation

  • @civilhunt1041
    @civilhunt1041 4 роки тому

    sir outer peripheral ka rod agar out of actual position se nikal gaya toh kaise Karna hai... apne toh andar wala ka hi dikhaya hai

  • @sajidchoudhary3464
    @sajidchoudhary3464 3 роки тому

    Sir yei to apne 230 kai grout kr leya footing k base pr sai lken slab pr sai colume out ho jaye to 230mm kai grout kaise hoga slab ki to thicknes hi 150mm ki hote hai waha kaise kre sir reply plz

  • @amitthakur8629
    @amitthakur8629 4 роки тому

    Sir agar chat par first ya second floor me hua hai to bhi same rule rahega kya

  • @abhishekshishodia9802
    @abhishekshishodia9802 4 роки тому

    Thanks

  • @tanweerabbas6628
    @tanweerabbas6628 4 роки тому

    Please upload a video on substation

  • @RaviKumar-wu2rr
    @RaviKumar-wu2rr 4 роки тому

    Sir column ke varticale Rainforment me jogal nahi karte h but column ke lap ke liye jogal kyu krte h please reply

  • @chennareddyindla2349
    @chennareddyindla2349 3 роки тому

    Good.

  • @anujarora4413
    @anujarora4413 4 роки тому

    Brother Jo displaced bar tha usko exposed point se cut kiya fir initial alignment me hole karke another bar usme insert ki fir cut ki hui bar ko L shape deke doosri bar se weld kiya?

  • @rahultolani7485
    @rahultolani7485 4 роки тому +2

    1 more question sir, bhot baar aisa hota h site pe, jab column size or column steel jaise jaise upr jaTe h to reduce ho Jaye h, as per steel design.
    Eg. Column C1 (230 X 530 mm) Mei initially steel is as 12 bars of 20mm upto third storey and for fourth storey steel is reduced to 8 bars of 16 mm and column size reduced to 230 X 450 MM... In this case what is the right way of providing the steel and lap connection of the column steel...please explain.
    Thank you 😊!!

  • @nitinpandharkar6646
    @nitinpandharkar6646 4 роки тому +2

    What is your suggestion for rebar which are not in position/need to be jackled. Did you cut these rebar? Or kept as it is in column

  • @vijayvlogs1170
    @vijayvlogs1170 3 роки тому

    Good sir

  • @a9450154247
    @a9450154247 3 роки тому

    Very impressive sir... Chote plot ya structure k liye piller itne heavy nhi hote h... Aur 4bar pillar me h aur 4 hole kr k ye process krna impossible hoga?? Waha kaise kare isko???

  • @msingh92
    @msingh92 4 роки тому +11

    site engineer: abe saale
    column bar : maaf krna gusse me idhar udhar nikal jaata hu

  • @saqlainsayed2641
    @saqlainsayed2641 4 роки тому

    But how to prevent this, what is the reason of this displacement

  • @alive4ffun
    @alive4ffun 4 роки тому

    When welding process will be introduced it also heat the bars and will make it hard as you said in video

    • @hanzalamusheerkhan8277
      @hanzalamusheerkhan8277 4 роки тому

      At place of weld always two bars are present so actual Ast is doubled, which accounts for loss in strength of steel; that's why always suitable lap length is essential, basic of lapping 🤗

  • @ghanshyammakwana3433
    @ghanshyammakwana3433 4 роки тому +1

    Super bro

    • @civilsitevisit
      @civilsitevisit  4 роки тому

      Thanks brother keep watching n keep loving

  • @rajivbhowmickgkb280
    @rajivbhowmickgkb280 3 роки тому

    Sir plz ek video banao 🙏🙏. Ager extention rebar small hain or corrosion se ager rcc rebar ka diameter kam ho jaye to 2nd 3rd floor extention kaise kare??

  • @fareedmohammed278
    @fareedmohammed278 4 роки тому

    20by45 main calum distance Kia Honda hai

  • @kartikjha7270
    @kartikjha7270 4 роки тому +1

    sir if in footing there should pcc 100mm then how we should insulation bar because when steel meet soil it should be not better

    • @civilsitevisit
      @civilsitevisit  4 роки тому

      for that conditio procedure is different i will upload on it soon

  • @nitinpandharkar6646
    @nitinpandharkar6646 4 роки тому +1

    Rebar embedment shall be designed for pull out capacity/force, it shall not be 230 mm. Newly embedded rebar length above concrete shall be lap length not @700

  • @sachinparmar2820
    @sachinparmar2820 4 роки тому

    Lekin sir jo sariya out ho gya usko to die marke column ke andar to lana pdega na. Ya fir out huwi bar ko cut kr lee

  • @prashantkumar-tg1wv
    @prashantkumar-tg1wv 2 роки тому

    Super sir

  • @sridharsahoo8159
    @sridharsahoo8159 4 роки тому +1

    Right he bro

  • @arvinddube1397
    @arvinddube1397 4 роки тому +1

    Sir ye bataiye if yadi collom lambai me sidha h lekin kuchh collom chaudai me ek line me nhi h to issse koi dikkat ho sakti h makan bad guniya ho gaya h to iska koi upay h ,yadi no. H to dijiye...

    • @civilsitevisit
      @civilsitevisit  4 роки тому

      haan dikhat houfi tiling n plaster meh ...shilna padega column

  • @Kshitijsingh91
    @Kshitijsingh91 3 роки тому

    Same work ghar k building me v karna chahiye kya

  • @sfr1390
    @sfr1390 4 роки тому

    sir maine apne lower floor ke bathroom ke upar bathroom banaya hai par upar wala neeche wali deewar se 2.1/2 fit bahar hai linter pe uska weight hai kindly guide

  • @muhammadharisbacha3466
    @muhammadharisbacha3466 4 роки тому

    Sir tile analysis Kai barai main vedieo bana dai

  • @mrklifeline8032
    @mrklifeline8032 4 роки тому

    Good

  • @amansharma307
    @amansharma307 4 роки тому +2

    Hello sir
    If we need to add a storey to building
    And top slab of building dnt have any extended columns
    What shall we do?

  • @subhashkapoor2507
    @subhashkapoor2507 2 роки тому

    My house is constructed two storeys..with 9"*9" columns on both sides..now I want to raise another two storeys on it...can I go with similar size columns or what to do..plz guide...thanx

  • @indianpandorabox7774
    @indianpandorabox7774 4 роки тому

    Gr8

  • @civilproof7836
    @civilproof7836 4 роки тому +3

    (in video)Top bar lapping is in beam column junction....is this right or wrong???????

  • @pardeepsaini5896
    @pardeepsaini5896 4 роки тому +2

    What happened when this problem arises at the 1st floor slab or above. I think this solution is only possible when the bars need to be fixed on footing. And what about the outer bar or the overall column reinforcement when they all displaced from their actual position.
    btw thanks for providing this information.

    • @sandpnyk
      @sandpnyk Рік тому

      true... but it helped me in an old retrofitting work where work upto plinth was wrongly done .. I can easily start afresh as per the drawing from plinth

  • @shailendradiwa8423
    @shailendradiwa8423 4 роки тому

    Sir...mere ganv ke ghar me column me yhi dikkat hua tha aaj ghar me crack aa rha h .... ab usko thik kiya ja sakta h??

  • @sanjaytudu4833
    @sanjaytudu4833 4 роки тому +2

    Perfect

  • @Waseemakram-fd3oe
    @Waseemakram-fd3oe 4 роки тому +1

    thank you sir aap ni zabardase video ke hai sir

  • @turtlebrains
    @turtlebrains 4 роки тому

    Kya ham chhat se naya structure taiyar kar skte hai

  • @viralintwala4249
    @viralintwala4249 Рік тому

    Which IS code allow this method ?

  • @myciviltechnology4250
    @myciviltechnology4250 4 роки тому

    Please also explain the type of welding because common welding is also reduce the strength of steel bars .a special welding is required called mechanical welding.

    • @sandpnyk
      @sandpnyk Рік тому

      butt weld should do the job

  • @sagarjadon2404
    @sagarjadon2404 4 роки тому +1

    Staircase marking slope and step both please upload

    • @civilsitevisit
      @civilsitevisit  4 роки тому

      soon brother keep watching and keep loving

  • @harshraj7307
    @harshraj7307 Рік тому

    Bhaiyaa mere ghar ise trah dhalai ho gya 3 room ek hall sara room badguniya nikal gya stairs be tedha ho gya ab second floor aisa na iske lea kya ho seckta hai ya kuch nahi ho payega

  • @Amit77500
    @Amit77500 4 роки тому +2

    Thank you sir
    Aap best me best ho sir

  • @adityajoundal8500
    @adityajoundal8500 Рік тому

    Yes sir 👍

  • @252ranjeetrajendrashinde5
    @252ranjeetrajendrashinde5 4 роки тому

    Pile ke bar rectangular shape me kaise kre

  • @sahilbanyal1232
    @sahilbanyal1232 4 роки тому

    What is the cost for rebaring?

  • @Rajeevkumar-qb1rj
    @Rajeevkumar-qb1rj Рік тому

    Usko position change karne ke liye Kitna inch jogal de sakte

  • @rahuldaroch682
    @rahuldaroch682 4 роки тому

    sir jo aap 750 bol rhe hou..uske accordingly agar columns mei bar 25 mm kaa hou toh as per is code456:2000 k hisaab se toh ban ee nai rha...lap should be 25*50=1250mm....how its possible 750mm.?????

    • @malharmemon6093
      @malharmemon6093 2 роки тому

      Sir wo lap length jo ap multiply krhe ho wo yahan kam ki nhi yahi formula hai 230 750

  • @wethepeople1996
    @wethepeople1996 4 роки тому +2

    But kya iss se strength kam ni hogi?
    Original k respect me?

  • @shivrgpandeya4679
    @shivrgpandeya4679 4 роки тому +3

    Sir ji,
    Steel cut kar denge but niche se aadha steel se match kaha ho payega
    Jo 230mm niche dril karke dall rhe vah concrete pr rest krega n niche steel k tuch me kaise rahega

    • @civilsitevisit
      @civilsitevisit  4 роки тому

      match ni brother ....bs insert n grout

    • @shivrgpandeya4679
      @shivrgpandeya4679 4 роки тому +3

      Ha vahi, confusion ye h ki jo steel niche se continue aarha uska end karke fir dusra steel dal rhe,us continue steel se link khatm hojarha n, ye doubt h mera

    • @vikasgawai9310
      @vikasgawai9310 4 роки тому +2

      Same doubt for me...

    • @ravipatel9316
      @ravipatel9316 4 роки тому +1

      Continuity will be break... we're going for newer steel with method of Rebaring...
      Yes, it's not as per design for spacing of vertical bars , but it's better option over jackiling of bars...

    • @pranjalbaishya834
      @pranjalbaishya834 4 роки тому

      continuety brek hoga.. sahi hai.. par twist karke continue krne se grout krna bettr hai...

  • @zoya1520
    @zoya1520 4 роки тому +1

    Jo bend ho geya tha uska kya hua ??? Cut kar Diya ya phir wyse hi chor diya ????

  • @pushpendraanu23
    @pushpendraanu23 4 роки тому

    I like

  • @VivekKumar-qq3ol
    @VivekKumar-qq3ol 3 роки тому

    10 by 10 ke pillar Mein ye process kaise karenge

  • @manojsahoo7579
    @manojsahoo7579 4 роки тому +4

    Hlo sir good afternoon... please make a video about on details of pile foundation ....nd quantity calculation ...

  • @surajitdas789
    @surajitdas789 3 роки тому

    Sir 230 mm niche samajh a gaya lekin upar toh 750mm dikha raha hai please ek 3d photo share kare sir

  • @civilpro9537
    @civilpro9537 4 роки тому +2

    Sir jo misplaced ho gaya hai ushe cut karke hatana hai kay ?

    • @civilsitevisit
      @civilsitevisit  4 роки тому

      haan jo misplace ho jyta hai usko htana hota hai

    • @civilpro9537
      @civilpro9537 4 роки тому

      instead of welding can we tight with binding wire sir ?

    • @pranjalbaishya834
      @pranjalbaishya834 4 роки тому

      wire se v sayad kr sakte ho.. lekin mazbooti utna nahi milega jitna welding main milega..

  • @yogeshkumar-jn5pb
    @yogeshkumar-jn5pb 4 роки тому

    Ye to centre ka steel hai agar side ke steel me jackle aye to kya kre

  • @a9450154247
    @a9450154247 4 роки тому

    Sir ye toh heavy piller k case me bataya...jab ki gher k piller 9 ya 12 inch k hote hai...uss case me shifting ko kaise correct krenge... Mere plot me kuch time pehle work hua tha ab usme sabhi piller ki sariya bend ho gyi hai... Toh usko correct kaise kiya jaye...

  • @bhardwaj_abhishek
    @bhardwaj_abhishek 4 роки тому +2

    सर आप बीच में ties की जगह stirrup बोल रहे है जो कि गलत है इससे students को गलतफहमी हो सकता है
    क्यूकी कॉलम में जो रिंग बांधा जाता है उसे ties कहते हैं और beam में जो रिंग बांधा जाता है उसे stirrups कहते हैं।

    • @civilsitevisit
      @civilsitevisit  4 роки тому

      eheheh aesa ni brother ties alag cheez hai stirrup alag

    • @bhardwaj_abhishek
      @bhardwaj_abhishek 4 роки тому

      @@civilsitevisit ties and stirrups me difference Kya h aap hi bta dijiye qki Mai bhi diploma Civil Engineer ka student hu
      Aur hme Aisha hi padhaya gya hai aur kuch vdo me bhi Maine yahi dekha h jaisa ki Maine phle btaya h

  • @kamaltoprani8860
    @kamaltoprani8860 4 роки тому

    Sir my house mistake underground Pani tank ke uper se coluam khada Kiya hai to ab kya kare

  • @fasttrendiz3411
    @fasttrendiz3411 3 роки тому

    Aur usi site pe ek cornaer ka coloum ka 6 inch bahar chala gya center line, to contractor, 2 sariya hi tod diya jad m, aur wo chorke plinth bim bhi dal diya, wo bhi 9*18 k colum th uska ky kre

  • @SK-ld9lu
    @SK-ld9lu 4 роки тому

    koi job h site engg k m pas out hu 2018 k r m delhi m hu i need a job plz hlp me..

  • @31Rohit_k_vlogs
    @31Rohit_k_vlogs 4 роки тому +2

    What should we do if that types of mistakes comes in first floor, where the thickness of floor is 150mm. And the size of column size is 250mm x 250mm.

    • @civilsitevisit
      @civilsitevisit  4 роки тому

      same hole 230 in column n insert steel n weld

    • @31Rohit_k_vlogs
      @31Rohit_k_vlogs 4 роки тому

      @@civilsitevisit any formula or any Thumrule for inserting of rebar like 15d , 20d Or anything else.

    • @ravipatel9316
      @ravipatel9316 4 роки тому

      @@31Rohit_k_vlogs not any formula... it's given in company's material description... it's vary for saperate material

    • @31Rohit_k_vlogs
      @31Rohit_k_vlogs 4 роки тому

      @@ravipatel9316 ok. Thanks

  • @AbhishekKumar-ic7tg
    @AbhishekKumar-ic7tg 4 роки тому

    Joggle hota hai jackel nahi