प्लिंथ बीम के नीचे ईंट चिनाई कर हजारों रुपए का नुकसान | Is it necessary to Brick under Plinth Beam

Поділитися
Вставка
  • Опубліковано 1 жов 2023
  • In this video, we're going to discuss the importance of brick masonry under plinth beam. We'll answer some questions like: is brick masonry required under plinth beam, is it a good solution, and what are the benefits of using brick masonry under plinth beam?
    Brick masonry is a popular solution for under plinth beam construction because of its strength and durability. By using brick masonry, you can avoid using less stable materials like steel or concrete, and you can get better insulation and soundproofing. So make sure to watch this video to learn more about the benefits of brick masonry under plinth beam!
    Your queries:-
    plinth beam ke upar eent ki chinayi
    eent ki chinayi kaise karna hai
    what is plinth beam
    brick masonry work on plinth beam
    plinth beam kasie banaye
    can we brick masonry under the plinth beam?
    pahle column dhalayi kare ya ita ki chinayi kare
    Contact Details:-
    1. For Sponsorship and Business
    Deepak Kumar
    Mob: +91- 9523101369 (also WhatsApp)
    Email:- civilengineer.deepakkumar18@gmail.com
    My Social Network
    1. Facebook:- / civilengineerdeepakkumar
    2. Instagram:- / civilengineer.deepakkumar
    #PlinthBeam #BrickMasonry #BrickWork
    #civilengineerdeepakkumar
    #civilengineeringdeepakkumar
    #engineerdeepakkumar
    #erdeepakkumar
    #deepakcivilengineer
    #deepakkumarcivilengineer
    #civilengineer
    #civilengineering

КОМЕНТАРІ • 186

  • @salimsarana4973
    @salimsarana4973 5 місяців тому +26

    सब लोगों का अपना अपना राग है, बेचारे घर बनाने वाले आधे तो इन यू ट्यूबरों से दुखी है,

  • @rameshwarbeldar3534
    @rameshwarbeldar3534 8 місяців тому +1

    अतिशय उपयुक्त माहिती 🙏🙏

  • @radheshyamphulwari215
    @radheshyamphulwari215 2 місяці тому +5

    सर प्लॉट रोड़ से 3 फिट नीचे है। प्लिंथ बीम 3.5फिट पर देना है तो ग्राउंड फ्लोर के घर के लिए फाउंडदेशन की गहराई कितने फिट करनी चाहिए ? कृपया बताएं।

    • @varcre167
      @varcre167 Місяць тому

      outer wall ko 2.5 feet se 3 feet tak neeche le jao... pillar ko 4 to 5 feet neeche....
      andar ki sari diwaro ko 6 inch se 1foot neeche

  • @somyapatel6969
    @somyapatel6969 6 місяців тому +1

    Very very good advice sir...

  • @porimolmedimedi5640
    @porimolmedimedi5640 10 днів тому

    सही काम के बारे मे जानकारी देने के लिए धन्यवाद

  • @bchandravlogger
    @bchandravlogger 6 місяців тому +3

    To prevent the soil filled inside from coming out, we will have to do brick work on the outside. 🧱 because hold of soil.

  • @mohdnisharul42
    @mohdnisharul42 4 місяці тому

    Good information sir

  • @abbujaan
    @abbujaan 6 місяців тому

    very informative

  • @jatindersingh1809
    @jatindersingh1809 9 місяців тому

    Good

  • @motibehera9645
    @motibehera9645 5 місяців тому +3

    Plinth beam se 1.5 feet DPC ka height karna hai,single floor building karna hai to Sir bataeye plinth beam ka base sand feeling 3 inch, pcc 3 inch aur Sir niche ka base brick bichha ne se hoga, please Sir answer de dijiye

  • @sanjusaini4492
    @sanjusaini4492 5 місяців тому +1

    Hi sir mara jamin road label se 4 fit niche eh please bta kya kare brick work kis label se start kare

  • @Abbasi804
    @Abbasi804 9 місяців тому

    very good sir i am cleared anyhow, i watched this video 3 times to understand deeply but sir you made
    very short video

  • @yugalsahu303
    @yugalsahu303 7 місяців тому +2

    Today my concept is cleared 🙏😊

  • @santoshjoshi9983
    @santoshjoshi9983 3 місяці тому

    Thanks sir

  • @MasterCivilEngineering
    @MasterCivilEngineering 9 місяців тому +5

    Master the concepts of Practical Civil Engineering here

  • @thawardaskrishnani4393
    @thawardaskrishnani4393 9 місяців тому

    Good video

  • @veer4702
    @veer4702 9 місяців тому

    Namaste sir ji

  • @Kakashi-hatke986
    @Kakashi-hatke986 9 місяців тому

    Good morning sir...apse janana chahenge ki slab dalne ka material formula kya hai..

  • @chitranshdewangan759
    @chitranshdewangan759 9 місяців тому

    Sir mere ko dumble banana hai kon se grade ke croncrete me thikness ayega

  • @rakeshsinghmaravi3115
    @rakeshsinghmaravi3115 9 місяців тому

    Jankari k liye thanks sir

  • @bipinkumar8131
    @bipinkumar8131 6 місяців тому +2

    1.Agar mera ground level 1.5 feet niche hai Road level se,
    2.Mujhe apna ghar FGL,Road level se 5 feet height pr rakhna hai tb Hume brick work kitna krna padega.

  • @fazalsubhan7064
    @fazalsubhan7064 5 місяців тому +1

    Sir can we do plum concrete under plinth beam? Sir make a video on plum concrete.

  • @amaldas-dl3te
    @amaldas-dl3te 5 місяців тому +1

    Ground level se4 feet upar hoo to brike ke nice keya de.

  • @radhakantabehera6696
    @radhakantabehera6696 7 місяців тому +1

    Hi Deepak..I have a doubt...
    Suppose we are planning to construct a building in agriculture land and the land is 2.5 ft below the road level...we want floor level 1.5 ft above the road level..total height land to floor is 4 ft..
    Should we provide brickwork 2 ft on the ground then 1 ft beam and 1 ft brickwork 6inch dpc??
    Or should we provide ground beam for such only outerpart of the structure then brickwork and then beam and dpc??
    Please comment
    Should be

  • @rajumurmu5783
    @rajumurmu5783 7 місяців тому +1

    Sir mera pathar hii pelith bim ke nich chinay karege ki nahi pelis bata dijiye

  • @Abbasi804
    @Abbasi804 9 місяців тому

    kindly sir one video on basement construction;; if we construct small house basement leaving passage or space 5 feet as street from all four corners of basement sand what should we do for retaining wall, can we construct wall of bricks or we have to do same rcc as retaining wall

  • @a.bsiddiqui6138
    @a.bsiddiqui6138 6 місяців тому +1

    Mere Ghar me 4 fit deevar 1 fit bhim total 5 fit Hite diya hun road lebal se 21× 50 ka aria bana h
    Charo side bahar bahar se deevad karni padi h mitti bharane aur mitti ko Pani bhar ke baithane ke liye

  • @ajayr2967
    @ajayr2967 6 місяців тому

    Namaste sir hamasra 30-50/1500sqer feetka plote hai usme hum three bhak ground full parking our first floor three bhak our second floor three bhak banaanekeliye plan kiyahai eskeliye Kitana piller jaroori rahenga sir please boliye .

  • @ajayr2967
    @ajayr2967 6 місяців тому

    G +2 Ghar banaanekeliye piller our plinth bhim me Kitana mm mm ke sariya jarroor Dena padega sir

  • @rajendrapawatekar9912
    @rajendrapawatekar9912 21 день тому

    Ground level से foundation (hard strata) तक कुछ कन्स्ट्रक्शन नही किया ऑर ज्यादा बारिश हुई नीचे से पाणी का बहाव बढा तो पुरा स्ट्रक्चर हँगिंग हो जायेगा...😢

  • @alambox8937
    @alambox8937 9 місяців тому +1

    Sir road se 4 fit niche gamin hai or road se 2 fit upor liya matlab 6 fit huwa to kiya kare kiuki hamara gamin road se 4 fit niche hai boliye sir please

    • @VinayVinay-uz8uu
      @VinayVinay-uz8uu 9 місяців тому

      in future u face the problem of water lagging etc

  • @AjaySahani-xr2vx
    @AjaySahani-xr2vx 9 місяців тому

    Ha thik

  • @surinderkumarbansal1072
    @surinderkumarbansal1072 5 місяців тому +1

    Hi Deepak ji
    How are you
    Thanks for your knowledgeable video
    Please help me in my work if my brick wall has shifted from column face, what can be done to repair

  • @DebaDeb-rh5lt
    @DebaDeb-rh5lt 9 місяців тому

    Sir namaste, very nice video,,sir Ghar k aandar Dpc or flooring k PCC me gape Kitna inch rehena chahia , plZ botayega

    • @user-sw7um
      @user-sw7um 6 місяців тому

      Dpc ke upar hi pcc hogi

  • @KunalSoni
    @KunalSoni 5 місяців тому +1

    sir jo new colony banti hai usme wo log colony ko main road se 4 feet uper uthate hai, 4 feet wo phele hi niche hota hai, colony wale sirf road uper karte hai , isme fir kya hota hai, 4+4 =8 feet to road level par ata hai, then 8+4(road level se uper)=12, usme me hume apna ghra road leve l se 4 feet uthate hai to is total 12 feet ki foundation ho gayi is structure ko samjahiye please. mera plot ka actual size yehi aa rha hai .

  • @dphogat
    @dphogat 5 місяців тому +1

    4 से 5 फीट गहरा है, तो भरत/मिट्टी भराई है रोड़ लेवल से, तो फिर तो brick work karna होगा ना sir या कोई और suggession है ?

  • @AshwaniKumar-ty1kp
    @AshwaniKumar-ty1kp 7 місяців тому +1

    Plinth beam jamin se 5feet upar ho to inner wall k neeche bricks work jaruri hai kya sir

  • @dukhharansingh1877
    @dukhharansingh1877 3 місяці тому

    हमें बताइए 10 फीट ऊंची पलींथ के लिए कैसे लाभकारी हो सकता है

  • @Abbasi804
    @Abbasi804 9 місяців тому

    most of people don't want even one brick under the plinth beam but strong foundation, you should make a long video on this topic and clear it from all aspect that how can we build a strong footing without bricks for triple storey house

  • @manishbaruah5574
    @manishbaruah5574 5 місяців тому +1

    Ho sake to 2 bhk elevated ghr ke bare mein batayen

  • @golaphoque2111
    @golaphoque2111 7 місяців тому +2

    4 fet may 2 bim hona chaiya kya 1 plan bim

  • @rakeshkumarpal9567
    @rakeshkumarpal9567 7 місяців тому +1

    Building के बाहरी दीवार में ब्रिक वर्क करना तो जरूरी है,, लेकिन,, क्या बीच की दीवार में तो प्लिंथ लेवल तक टाई बीम cast कर DPC देकर उसके ऊपर ईट जुड़ाई तो हो सकता है यानी टाई बीम के नीचे ईट जोड़ने की आवश्यकता नहीं होगी।

    • @user-sw7um
      @user-sw7um 6 місяців тому

      bich me no brick work

  • @dineshchandra9666
    @dineshchandra9666 7 місяців тому +1

    हमें जमीन के नीचे कितने फिट तक कॉलम की खुदाई करनी चाहिए
    क्या नीव के नीचे भी ईंट की रोड़ी डालनी चाहिए या नहीं
    मुझे 6 फिट तक मिट्टी का भराव करना हैं तो नीचे 9 इंच की चिनाई करनी चाहिए या 4 इंच चिनाई करनी चाहिए

  • @binodsah7860
    @binodsah7860 7 місяців тому +1

    sir ji नमस्कार ,
    मेरा आप से एक सवाल है ,अगर पलौट मेन रोड लेवल से 4' निचे है तो pilinth beam कहाँ पे /कौन सि लेवल मे डाले मेरा मतलव है कि 1'6" चिनाई करने के वाद pilinth beam डाल सकते क्या?

  • @veer2806
    @veer2806 9 місяців тому +25

    Pichla ekh video me zaruri hai aise bata chuke hai sir.

    • @vipinoraon5503
      @vipinoraon5503 9 місяців тому +2

      Haa

    • @civiltech1193
      @civiltech1193 9 місяців тому

      Ghar bich me ho aur Boundrywall ho us condition me bole honge.. Ghar k plinth beam bdle Boundrywall k niche brickwork dene se paisa bhi bchega aur filling material bhi bahar nahi jayega....

    • @ravishkhattri8824
      @ravishkhattri8824 4 місяці тому +1

      Pahle iska opposite bataya tha

    • @pankajchoudhary1126
      @pankajchoudhary1126 9 днів тому

      Sahi kaha

  • @purushottamkumar4173
    @purushottamkumar4173 4 місяці тому

    If floor level ke 5 ft niche sand hai to foundstion kaisa hogs

  • @shambhurajak7670
    @shambhurajak7670 5 місяців тому +1

    यदि ईंट की‌ चुनाई कर देते हैं 😢तो क्या मकान को नुक्सान हो जायेगा। कृपया प्रकाश डालें।

  • @ALLREPAIRING
    @ALLREPAIRING 9 місяців тому

    Hi sir

  • @fahedahmed786
    @fahedahmed786 2 місяці тому

    If we are giving footing 4 or 5 foot below to the the road level, then what should be done

  • @VikashKumar-yo6fq
    @VikashKumar-yo6fq 5 місяців тому

    Kya plinth bim ke nicche agar brick work karte h to v soil fir PCC karna hoga

  • @luckysharma9974
    @luckysharma9974 4 місяці тому

    Hello sir This is Lucky.
    Jesa ki apne bataya ki 3-4 feet plinth level rakhna ho ,, road level se ,,, to hm plinth beam k niche brick masonry kar sakte hai,,,
    To me janna chahta tha ki ,, fir brick masonry ke niche base banane k liye kya karenge?
    Please guide

  • @akhilkumarsahoo949
    @akhilkumarsahoo949 5 місяців тому +1

    Mera plot road level se 6ft niche he to fir pitch beam ground se 6ft uper rakhunga the pinch level ke niche brick work sirf outdoor wall me karunga ya ander partition wall ke niche brick work karunga pls suggest me

    • @pravinchandra1347
      @pravinchandra1347 4 місяці тому

      बीच की दीवारों की भी ईंट चिनाई कर लें वरना मिट्टी का प्रेशर आउटर वॉल में क्रैक ला देगा

  • @minhazalam1720
    @minhazalam1720 7 місяців тому

    Dpc में भी सरिया देना है क्या सर???
    Plzzz help me

  • @premnarayannayak6827
    @premnarayannayak6827 6 місяців тому +1

    Sir ji 11 feet chhat ki height ke liye kitna feet jagah chahiye sidhi banane ke liye

  • @karyanandkumar1285
    @karyanandkumar1285 23 дні тому

    Sir mera 45*18squar feet ka plot hai aur three side me diwar diya hua hai to kya hume bhi diwar de kar hi foundation Dena chahiye ya kolam dekar mitti bharne ke bad foundation vim dhal de sir
    Hum ko kya karna chahiye sir

  • @KrishKumar-uo6eh
    @KrishKumar-uo6eh 4 місяці тому

    Ground beam kis cundiction me dena hai sir

  • @sumitdora6252
    @sumitdora6252 5 місяців тому +1

    Mera graund level 5 fit he kya keru

  • @avisharma2016
    @avisharma2016 7 місяців тому

    Sir chikani mitti mai nichi diwar lagan hai

  • @chhotuprajapati5687
    @chhotuprajapati5687 9 місяців тому +2

    Sir, 3 feet height maintain karne k liye 1 feet k plinth beam k uper 2 feet brick work kar sakte hai Kya???

  • @AkashKumar-eh7bc
    @AkashKumar-eh7bc 9 місяців тому +2

    Bhai ye batao outer wall mein brick work to thik hai par kya iner wall foundation mein brick karana jaruri hai ya nhi, ya only column aur plinth beam dalkar soil fill kar de, 3 floor ke liye mazboot to rhega na please reply

  • @deepak9913
    @deepak9913 9 місяців тому +1

    Frame structure and load bearing structure me kaun sa badhiya hai?

    • @arindamarindam777
      @arindamarindam777 5 місяців тому +1

      load bearing structure..

    • @motomajid
      @motomajid 4 місяці тому

      Dono ke apne merits and demerits hain, requirement pe depend karta hai kon sa option better rahega kaam ke liye.

  • @vedprakashsingh9870
    @vedprakashsingh9870 7 місяців тому +1

    Waterproof lape kya hai?

  • @narendrabag4949
    @narendrabag4949 9 місяців тому +1

    Sir 🙏🙏
    Sir niche se 4 feet hight tak Bricks work karke, Plinth Beam deke direct Beam ke upar se Bricks work ka kam start karne se chalega kya ? ki fir Dpc dena jaruri hai ?

    • @cmsgp7782
      @cmsgp7782 8 місяців тому +1

      बिलकुल चलेगा,,,,

    • @ayushsharma6745
      @ayushsharma6745 3 місяці тому

      Dpc de do nai toh sejal ajayegyi diwaro par

  • @santoshbawane2048
    @santoshbawane2048 18 днів тому

    Yadi thekedar ne boundary wall aur fondation sath me kiya to use thik kaise kare

  • @dineshmurmu1241
    @dineshmurmu1241 5 місяців тому +1

    Kis Is code me diya hai...guruji

  • @Addu9719
    @Addu9719 8 місяців тому

    Sir, mera ghar ka ground level se plinth tak 5 feet ka bharav h, mujhe kaise krna chahiye

  • @jeanoopsingh
    @jeanoopsingh Місяць тому

    Another video me aap ne btaya he ki PB ke niche Brick wall jaruri hota he....ni to outer wall me crack AA Jaye ga

  • @charanjeetsingh4476
    @charanjeetsingh4476 8 місяців тому +1

    Sir plot road ke level se 1feet niche hai or floor level road se 4 feet height per dena hai plinth beam kha per dena chahiye?

    • @user-sw7um
      @user-sw7um 6 місяців тому

      Ek ground beam fir brick work fir 3 feet height pe plinth beam fir 1 feet ke baad dpc

  • @vinodmathur7423
    @vinodmathur7423 8 місяців тому

    Hello brother Maine ghar banwaya h ek beam natural ground level per h Or ek beam road level per h mere ghar k natural soil level beam k neeche brick work nhi h but dono beam k beech brick work h.. Theek h kya ya jo ground beam h uske neeche brick work zaruri h

    • @user-sw7um
      @user-sw7um 6 місяців тому

      Grond beam ke niche brick jaruri 3 feet pe plinth beam ho ti

  • @user-sm5rw3dv5h
    @user-sm5rw3dv5h 9 місяців тому

    Plinth 8 feet high from road
    Then must provide all around brick wall or concrete wall under plinth beam

    • @user-sw7um
      @user-sw7um 6 місяців тому

      Yes 5 feet brick work then plinth beam

  • @surendrashaw4192
    @surendrashaw4192 6 місяців тому +1

    Sir,aap laver provide karte hain kya ?
    May me ghar banana hai.hum Vaishali district me rahte hain.

  • @daniyalmashi8386
    @daniyalmashi8386 5 місяців тому +1

    Ground level par ek single eant rakh kar bager chinayi k beam daal sakte hai kya, please bataye

    • @user-sw7um
      @user-sw7um 5 місяців тому

      Yes on hard soil

  • @vakilparjapati9488
    @vakilparjapati9488 5 місяців тому +1

    Jameen se dhai feat upar palenthbim dal sakta hun Ki nahin

  • @AbdulBasit-wn6hb
    @AbdulBasit-wn6hb 5 місяців тому +1

    Hamara iha jameen se komse Kom 5 feet ucha rakna padta hain iske liye p beam upar rakuu yaa bricks upar rakku

  • @FullmunVlogs
    @FullmunVlogs 9 місяців тому

    sir i have mailed you about my doubts .. please have a look at it 🙏🏻🙏🏻🙏🏻

  • @chandershekhar1497
    @chandershekhar1497 4 місяці тому

    Guru ji tae beam ka concept btaye 🙏

  • @subratamandal2748
    @subratamandal2748 9 місяців тому

    Sir singal gali ma ka chad dhalai kar sak ta ha 1 rum ka size 12/10 ha 10" Rod sa no crank

  • @rameswarnag7971
    @rameswarnag7971 6 днів тому

    Pl Demonstrate actual work on the spot

  • @user-ul6ni2cw3g
    @user-ul6ni2cw3g 4 місяці тому

    आज समझ आया प्लीथ बीम और डीपीसी क्यों बनाते है

  • @dhanpaljain3360
    @dhanpaljain3360 3 місяці тому

    Neem ki khudai road se 6 feat niche karni hai aur 6 inch motai ki PCC karne ke bad pathar ki chunai karenge aur iske bad DPC karenge to kaisa rahega uske bad Eitki chunai karna shuru karenge please sar ji aap ki Salah kya hai

  • @ramnareshpandey6861
    @ramnareshpandey6861 3 місяці тому

    Kindly br 6:24 eaf details on ground

  • @GovindKumar-wr3tg
    @GovindKumar-wr3tg 4 місяці тому +1

    To fir miti kaise bharenge sir

  • @maheshk.srivastava9605
    @maheshk.srivastava9605 7 місяців тому +1

    Sir plinth beam ke uper 1 fit ke bricks work me waste water ke liye pipe dete hai to dewaar week ho jayegi kya 🙏

    • @user-sw7um
      @user-sw7um 6 місяців тому

      Diwar pehle banegi fir bich me hole karke fir diwal kamjor nahi hogi

  • @waveofsky8867
    @waveofsky8867 8 місяців тому

    ताज महल,,,लाल किले की नीव कैसे रखी गई,, इसपर भी बताये,

  • @pawankumarverma9395
    @pawankumarverma9395 6 місяців тому +1

    48*38 में कम से कम कितने पिलर होने चाहिये

  • @CGfamily976
    @CGfamily976 3 місяці тому

    Jameen upar niche Ho to kya Karen print table level ke liye

  • @madhavsingh1918
    @madhavsingh1918 16 днів тому

    Brick masonry nahi diya jata h plinth beam Kai neche issse moistureeaa jaiyega or crack develop hoga

  • @balkrishan4607
    @balkrishan4607 7 місяців тому

    Agar ham nichai itan nahi lagai ghain to Jo saath ka making hogab jab bo ghar banayigha to nichai ghar ki mitti Khali nahi ho jaighi

  • @narendratanti4839
    @narendratanti4839 Місяць тому

    Outer wall me plinth beam k niche brikh work Krna jaruri hai

  • @Abbasi804
    @Abbasi804 9 місяців тому

    sir agr foundation beam bhi diya gya ha to phir plinth beam k nichay bricks masonry required ha kiya aor agr gound beam bhi dey diya gya ho to phir bricks ka kaam krna zruri hoga kiya,,,, actually i want to ask , is it possible to get strong foundation of a house without any bricks masonay under the plinth beam

    • @VinayVinay-uz8uu
      @VinayVinay-uz8uu 9 місяців тому

      not neccesary but we can do 2 feet of brickwork and back fill moram soil and do good compaction after that have grade slab with steel reinforcement on top beam of plinth

    • @Abbasi804
      @Abbasi804 9 місяців тому

      thank you bro@@VinayVinay-uz8uu

  • @SaurabhMishra-dl3sf
    @SaurabhMishra-dl3sf 9 місяців тому

    Sirf 18 pillar Jameen se Aakar ground level per FIR 2 feat Eid ki chaudai ke bad 1 feat plinth level hai to kya yah Makan kamjor hai pillar 1 Fit lambai chaudai hai bahut chintit rahata hun yah janne ke liye

  • @virendrakumar-ge2nm
    @virendrakumar-ge2nm 9 місяців тому

    Sir agr 5 fit hight ho to

  • @priyanshuverma1296
    @priyanshuverma1296 6 місяців тому +1

    6 foot ki height per plinth beam kaam karega

  • @user-jq8hb7se3d
    @user-jq8hb7se3d 6 місяців тому +1

    4 feet high mein Kya kare

  • @devishankar7242
    @devishankar7242 6 місяців тому +1

    Sarpanch 11 ke upar 1 foot ki Chennai karke apna chaukhat rakh sakte hain ki nahin taki humko pareshani isliye hoti hai ki ham bahar pipe nikaalne ke liye theek rahata hai Narwal ke liye bathroom ka pani nikaalne ke liye nahin dikkatein padati hai to theek rahega ki nahin

  • @kabitasubba7720
    @kabitasubba7720 9 місяців тому

    Sir kripa karke jarur reply dijiye plinth beam 1 feet uthake 2 feet share wall utha liya toh uski uppar 2 feet ki uppar fir halka sa 12 mm ki 4 pieac karke beam de diya ghar k sirf bahar bahar wall di room ki andar nhi share wall nhi di without share wall uppar uppar 2 feet me bheam utha di .kya process jo kahi galti toh nhi huwa

    • @VinayVinay-uz8uu
      @VinayVinay-uz8uu 9 місяців тому

      u can do like that also and one thing if u have enough money u can go shear wall with internal walls and provide grade slab over it

  • @shekhardhotre1726
    @shekhardhotre1726 9 місяців тому

    Sir ji mujhe East face Makan 25*30. Banvana hai kitna kharch aayega

  • @rakeshsinghmaravi3115
    @rakeshsinghmaravi3115 9 місяців тому

    Sir agr plinth beam ka high 9 inch rakhna hai aur Road leval se 18 inch upr rkhna hai to brick work kre ya nhi

  • @user-ku2vg5zb7t
    @user-ku2vg5zb7t 9 місяців тому

    Sir aap pahale brick wark karne ko kahte hai aur uske baad brick nahi karne ko kahte ho

  • @Rajyadav-pq3xv
    @Rajyadav-pq3xv 5 місяців тому +1

    बेसमेंट की ऊंचाई कितनी होनी