1:03 Rather than "add that on", you should instead subtract the resistance reading of the meter and leads from the resistance reading of the glow plug. Thanks for a helpful video.
If your vom reads .2 ohms, and you test gp & value is .7, then, real value is .5, so, still within spec, my question is brand new out of box, mine read .2 to .4ohms, is that ok?
1:03 Rather than "add that on", you should instead subtract the resistance reading of the meter and leads from the resistance reading of the glow plug.
Thanks for a helpful video.
FYI: the diagram showing the glow plug connectors is wrong, ...the Green is for the Odd (RH) cylinders, and the Black is for the Even (LH) cylinders
If your vom reads .2 ohms, and you test gp & value is .7, then, real value is .5, so, still within spec, my question is brand new out of box, mine read .2 to .4ohms, is that ok?
You can just unplug the glow plug harness the one with the red lock tabs, much easier than screwing with the relay..
I thought that you could probably do that instead too, thanks for verifying.