Load Calculation for G+2 Building | Column load calculation | Influence area method | Part -1

Поділитися
Вставка
  • Опубліковано 6 жов 2024

КОМЕНТАРІ • 95

  • @CivilEngineeringMastery
    @CivilEngineeringMastery  Рік тому

    Dear All,
    Kindly check out the below link for
    Structural Analysis and Design of RCC building using Staad.Pro software.
    In this course, all the basic concepts, and Lateral load Analysis(Response spectrum and wind load analysis) of a building as per IS-456, IS-875, IS-1893-2016, and detailing as per IS-13920 have been explained.
    www.udemy.com/course/staadpro-v8i-structural-analysis-design-of-a-rcc-building/?referralCode=C1CBC2B104EF72579338

  • @helenatijing8798
    @helenatijing8798 3 роки тому +12

    We are using this method in my past jobs,this is fast and effective.Nowadays many softwares are born but yet,we are doubting the results beacause of unseen errors in analsyis,by doing this you can check your design and analysis and sleep well.😂😂😂

  • @designsource4481
    @designsource4481 4 роки тому +2

    This is the best tutorial in my life.Very clear concept method.Thanks for make this kind of tutorial.

  • @civilengineeringknowledge7250
    @civilengineeringknowledge7250 4 роки тому +3

    Very helpful for me

  • @عبدالكريمحسنبحر
    @عبدالكريمحسنبحر 4 роки тому +1

    Thank you mom you are the best

  • @sayandas8914
    @sayandas8914 4 роки тому +4

    Mam your tutorials are too good💚💛mam i have one request to you can you please give us a tutorial about how to design a building manually by comparing the same model with staad pro.please mam.It will be very much useful for students and working professionals both🙏🙏

  • @kamalahamed8586
    @kamalahamed8586 5 місяців тому +1

    super

  • @saisekhar5454
    @saisekhar5454 4 роки тому +2

    Very helpful 👍 video

  • @narendrarbhagyaa1012
    @narendrarbhagyaa1012 4 роки тому +1

    Thank you madam this was very helpful to me

  • @ershashankkumar3991
    @ershashankkumar3991 4 роки тому +1

    Very helpful all vedios. Please provide more videos on manual practice with staad design. Thank you

  • @faizanshaikh6036
    @faizanshaikh6036 2 роки тому

    Definitely these all tutorials are very helpful for students.keep it up mam👍👍.and make a more video on whole design of building from start to end with different geometry.Thank u

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  2 роки тому

      Sure 😊

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  2 роки тому

      I have created a course, structural design of buildings using Etabs software which includes structural analysis and design of a five-sorey RCC building(Real project) and is now available on udemy.
      Kindly use the below link to avail the full course.
      www.udemy.com/course/structural-design-of-buildings-using-etabs-software/?referralCode=14883FDBBD95A1ADAC02

  • @rahulsanapally
    @rahulsanapally 8 місяців тому +1

    AWESOME MAM U R SIMPLY AMAZING U GOT GREAT KNOWLEDGE IN CIVIL ENGINEERING MAM HOW CAN I GET THOSE AUTOCAD DRAWINGS TO PRACTISE🙏🙏🙏

  • @malinisankar2400
    @malinisankar2400 3 роки тому

    Hai mam. Thank you so much for your videos. It s explained very detailed. One kind request can u provide autocad file so tat i can practise better.. pls. I have seen few other people also requested the same. Pls do this favor mam

  • @abhisheksen325
    @abhisheksen325 4 роки тому +2

    Please share the load calculation of an elevator and also share the load calculation of steel building

  • @MohammedImran-wz4kv
    @MohammedImran-wz4kv 4 роки тому +1

    good explanation tq.

  • @Salman15691
    @Salman15691 4 роки тому +1

    Best Video. Ma'am I've one question that why are you not factored load in calculation..

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 роки тому

      I have factored at the last please watch all parts of this video series.
      ua-cam.com/video/XSptmc1s1Do/v-deo.html
      ua-cam.com/video/7cpyZ8S666E/v-deo.html
      ua-cam.com/video/0RXEcu5URYo/v-deo.html
      ua-cam.com/video/vjSE1W3tgvE/v-deo.html

  • @civilengineeringknowledge7250
    @civilengineeringknowledge7250 4 роки тому +2

    Please give a video on all about design of a two story building step by step i.e. 1st floor design and ground floor design, slab design, beam design, column and footing , and all loads calculation that load comes on that section.

  • @ersedhuramprasanth7161
    @ersedhuramprasanth7161 4 роки тому +3

    How you calculated influence area for particular columns as you mentioned in plan?.plz make video of ,how to assign size of footing, column,beam and distance between column.

  • @nageshwaraonandigama6194
    @nageshwaraonandigama6194 4 роки тому +1

    Super madam

  • @rahmanrahmani2896
    @rahmanrahmani2896 4 роки тому +4

    Could you please explain how you have decided the contributory area to each column in your AutoCAD drawing. The load calculation is straight forward (load from slab & wall to beam to column then foundation). Thank you!

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 роки тому

      Yes correct,but this is influence area method in which the slab load can be transferred to column by using the tributory area.
      Contributory area for each column can be decided by using center line of the columns.

  • @jaydeepganguly6144
    @jaydeepganguly6144 Рік тому

    Please make video on manual calculation of Mux and Muy for g+2 building frame

  • @greenenvironment7098
    @greenenvironment7098 4 роки тому +1

    Nice one..

  • @naveenkumarmakamala1059
    @naveenkumarmakamala1059 4 роки тому +2

    Please upload the autocad design also

  • @mageshkumart4362
    @mageshkumart4362 Місяць тому +1

    🎉

  • @mayappamechhennavar6418
    @mayappamechhennavar6418 3 роки тому +1

    Mam How To Calculate the ultimate XI load of the building to calculate the size of the column?

  • @syed7451_civil
    @syed7451_civil 3 роки тому +1

    G+2 residential building ke Liye ground floor beam ke liye kitna mm ka rod use kare.
    Beam size 250× 400 mm
    For idea
    please reply

  • @AAAFriends
    @AAAFriends 4 роки тому +1

    Please upload videos architecture plan same as structure plan with structure analysis in staad pro.

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 роки тому

      Please refer the below links for staad.pro analysis
      1.Modelling in Staad.pro with plate elements
      ua-cam.com/video/ZVOkGrQsjHk/v-deo.html
      2.Assigning loads in Staad.pro
      ua-cam.com/video/xuUn46lwcuA/v-deo.html
      3.Results from staad.pro analysis
      ua-cam.com/video/o6hA3eX9-qU/v-deo.html

  • @nageshwaraonandigama6194
    @nageshwaraonandigama6194 4 роки тому +1

    We expected more valuable vedios from you

  • @asifkhatri3769
    @asifkhatri3769 3 роки тому +1

    How to check upper storey column load in staad pro???

  • @lokeshacharyab.g8006
    @lokeshacharyab.g8006 Рік тому

    Madam how to design single column using load and moments in staadpro software? Which are the two moments tob considerede to mmoments or bottom moments

  • @mayurchoudhari6578
    @mayurchoudhari6578 3 роки тому +1

    How to calculate the thickness of slab

  • @mdsarfarazali4151
    @mdsarfarazali4151 4 роки тому +1

    Please send full details manual designing

  • @zarghamhaider735
    @zarghamhaider735 3 роки тому +1

    Please ans 25kn/m3 or 25kn/m2 which one is correct???

  • @mdriajulislam8828
    @mdriajulislam8828 4 роки тому +1

    maam im in a big problem my load came 93000 kg in 12 m2 now i cannot convert them in cm how much would be for my column concrete load in per cm2????

  • @zarghamhaider735
    @zarghamhaider735 3 роки тому +1

    Beam
    Lxbxd =.230x.375x25=Xkn/ans in meters .
    What is beam length

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  3 роки тому

      self weight of beam calculated as uniformly distributed load in kN/m.
      0.23 x 0.375 x 25 = 2.156 kN/m.

  • @gowthamiv4841
    @gowthamiv4841 4 роки тому

    Here you have calculated one column load but simply multiplied.. Actually number of columns per and floor and number of stories then total load arrive..

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 роки тому

      Here we are calculating loads on individual column and some times loads coming on each floor may differ. So we have to calculate loads coming on each column and each floor.
      In this calculation we have calculated loads coming on each floor for individual column. only the self weight is multiplied by number of floors.

  • @zarghamhaider735
    @zarghamhaider735 3 роки тому

    Mam. 125x25 (unit weight of rcc is 2500 but not in m2

  • @vishalsharma2290
    @vishalsharma2290 Рік тому

    How to extend my Ground floor column... For first floor....
    Ground is old construction now I want to construct a first floor

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  Рік тому

      Kindly contact the engineer who is available at your location. Without a proper analysis of the existing site condition, we cannot guide you.

    • @vishalsharma2290
      @vishalsharma2290 Рік тому

      @@CivilEngineeringMastery local engineer ask about rebaring ... But I m not rebaring nis safe for column member....

  • @deepbhavsar5231
    @deepbhavsar5231 4 роки тому +1

    *For Column Selfweight is in KN* and for wall & slab it is in KN/m?? Why??

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 роки тому

      Load transfer mechanism is slab to beam,beam to column and column to foundation.
      Slab loads are area loads, we calculate per m^2.
      Wall and beam loads are uniformly distributed loads which is kN/m.
      Column loads are axial loads which is kN.
      Please refer the below link for more details.
      ua-cam.com/video/AJG1Jix8NDk/v-deo.html

  • @elliotfamutimi9776
    @elliotfamutimi9776 2 роки тому

    Why is wall load not included for beam load calculation

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  2 роки тому

      Wall is load calculated separately and added with the total load. Please watch the complete series (part 1 to part 5) for a better understanding.
      Part-1
      www.youtube.com/watch?v=q8-pu...
      Part - 2
      www.youtube.com/watch?v=XSptm...
      Part - 3
      www.youtube.com/watch?v=7cpyZ...
      Part - 4
      www.youtube.com/watch?v=0RXEc...
      Part-5
      www.youtube.com/watch?v=vjSE1...

  • @mohankumars9877
    @mohankumars9877 4 роки тому +1

    How do we get that influence line diagram

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 роки тому +1

      Influence area is calculated based on center to center between column.
      Please refer the below link for more details about influence area
      ua-cam.com/video/ptaC2hdd5YY/v-deo.html

    • @mohankumars9877
      @mohankumars9877 4 роки тому

      @@CivilEngineeringMastery okk mam

  • @ultimatewarrior3829
    @ultimatewarrior3829 2 роки тому +1

    Mam i have work for you like design calculation estimation etc we have small consultancy. I will pay

  • @sumankumarparida8610
    @sumankumarparida8610 4 роки тому

    Can i get the the autocad file for better learning..

  • @ezhilarasan3776
    @ezhilarasan3776 4 роки тому

    This method only used for g+2 building?

    • @CivilEngineeringMastery
      @CivilEngineeringMastery  4 роки тому

      No.Influence area concept is same for all the buildings.Only loading we need to consider according to the type of the building.

    • @ezhilarasan3776
      @ezhilarasan3776 4 роки тому +1

      @@CivilEngineeringMastery thanks for the rply

  • @darwinvillamor937
    @darwinvillamor937 3 роки тому

    no load for roof??

  • @rajalakshmirajendran7259
    @rajalakshmirajendran7259 3 роки тому

    How to draw the influence area drawing mam...

  • @shamsheralirana3127
    @shamsheralirana3127 4 роки тому

    Madam size of Column kese mila?
    Kyunki size of Column find out karne ke liye humare paas Load hona zaruri he.

    • @HammadBashir809
      @HammadBashir809 3 роки тому +1

      by trial you can do. with experience

    • @shamsheralirana3127
      @shamsheralirana3127 3 роки тому +1

      @@HammadBashir809 Assalamu alaikum sir,
      Sir matlab ki pehle hume assume karna padta he Column ki size jese 9'×18 , 12×18 etc
      Right?

    • @HammadBashir809
      @HammadBashir809 3 роки тому +1

      For larger span, load will more Column size will large. For smaller span it may be small.

  • @yirrroy22tyrri82
    @yirrroy22tyrri82 3 роки тому

    I cannot understand how we calculate wall load in per unit squ.area???! Why not per unit length kn/m???! If the slab to be designed is flat slab then ok its logical to take partition per unit area.

  • @alexmungoma5030
    @alexmungoma5030 2 роки тому

    i dont have a credit card how do i get one

  • @vishnusan3249
    @vishnusan3249 4 роки тому

    Tamil ilaya madam

  • @VinayKumar-lm2hf
    @VinayKumar-lm2hf 3 роки тому

    Hindi me bataiye

  • @RutuPatel1999
    @RutuPatel1999 4 роки тому

    Can you send me staad pro crack software link & working software..... ?