How to test a 12 volt Beckett burner ignitor

Поділитися
Вставка

КОМЕНТАРІ • 22

  • @galagauthier
    @galagauthier 3 роки тому +1

    you need to show one where it all missed up to see the difference. Even a photo dropped in to see it... Very good video Marco you guys did a good job!

    • @washmart8616
      @washmart8616  3 роки тому +2

      If it's messed up, it simply won't spark.

  • @fpplsoftwashpressurewashin8757

    Outstanding video. I may need an igniter and I'll know who to call.

  • @Gma-eats
    @Gma-eats 2 роки тому +2

    Ty very good explanation, much appreciated

  • @andrewbandarovich1751
    @andrewbandarovich1751 3 місяці тому

    Great video. Dad rocks. Thanks.

  • @simplycleanpressurewashing758
    @simplycleanpressurewashing758 3 роки тому

    Thanks for the share, good info.

  • @sheppardgee3361
    @sheppardgee3361 3 роки тому

    Thanks WashMart!!

  • @hudsonpressurewashinginc.4237

    Hi Marco, can you ask your dad what's the benefit of bypassing the sight. The 2 yellow wires are cut and tapped off separately.

  • @djonetwelve1944
    @djonetwelve1944 Рік тому +1

    Mine is currently pumping fuel and I hear the blower motor turning. It pumps some much fuel I can see it leaking. Do you think the excessive leaking fuel possibly damaged the cad eye cell?

  • @shanewoods2448
    @shanewoods2448 9 місяців тому

    What if the blower motor runs without the burner switch being on. As soon as I turn on my ign switch blower comes on w therm off and power switch off. New water coil, press switch, and ignitor fully rewired. Any input would be appreciated

  • @nikolayskatin1881
    @nikolayskatin1881 2 роки тому

    Hi, I have an issue with diesel burner igniter, I am in Canada.
    after I turn fan on, igniter will produce spark for ten seconds and then shut off, "please note no fuel supply at this moment". When I repeat procedure right away, no spark at all. Only if I wait 5 seconds and turn fan on again, spark will be present for ten seconds again. So, the problem is if I won't squeeze pressure washing gun in 10 seconds I won't have ignition, and fuel pump will shoot diesel into the coil chamber. Igniter won't start working again until I turn fan off, wait 5 seconds and turn it back on. It's a new unit, and I don't think it should work that way. Any advice or solution would be much appreciated.
    Thank you

  • @mixaliskapodistrias6260
    @mixaliskapodistrias6260 2 роки тому

    I am facing a problem with this kind of oil burner in Greece. Should the ignitor remain on for as long as the fire is burning? Or, should the ignitor turn off , after the fire is lit?

    • @washmart8616
      @washmart8616  2 роки тому +1

      If you have no photocell the igniter will remain on. If you have a photocell the igniter will turn off. Once a flame is established the igniter does not need to remain on. This also makes it to where your burner will use less amperage.

    • @mixaliskapodistrias6260
      @mixaliskapodistrias6260 2 роки тому +1

      @@washmart8616 I will try to make it turn off. I appreciate your response!

    • @washmart8616
      @washmart8616  2 роки тому

      @@mixaliskapodistrias6260 you're welcome! I love knowing the Greeks are seeing our videos!

  • @MotoV8t
    @MotoV8t 2 роки тому

    Mine works well for a maybe an hour, then out of no where produces alot of black heavy smoke. Any ideas?

    • @washmart8616
      @washmart8616  2 роки тому

      Most of the time it is because it's still injecting fuel when there is no flame, even if just for a moment will cause this

    • @robertgall1275
      @robertgall1275 Рік тому

      I have this same problem and it's very frustrating. I think it's an intermittent ignitor problem.

    • @atm1513
      @atm1513 Місяць тому

      Any fix? I have this problem too. I'm waiting to install a new nozzle.

    • @MotoV8t
      @MotoV8t Місяць тому +1

      @@atm1513 it stopped doing it on its own

  • @superiorhoodcleaning
    @superiorhoodcleaning Рік тому

    Or you can just ohm the springs should be between 480/580 more than 10%above those no good