BALLAST STACK MEASUREMENT I BALLAST SAMPLING I GRADATION TEST I BALLAST की QUANTITY कैसे निकाले ?
Вставка
- Опубліковано 22 жов 2024
- #TrackBallastStackMeasutement
#BallastQuantityMeasurement
#BallastSampling
#BallastGradationTest
#RDSOGE1recommendations
#CivilEngineeringTutorials
#UPSCESE #SSCJE #STATEPSCAE/JE #GATE #Quality Control Engineer
#YogeshKaushikSir
In this video, detailed discussion of #Measurement of #quantity of #track ballast and #gradation test of #ballast as per #RDSO GE1:2004 recommendations has been done with its significance, which will be useful for aspirants of UPSC ESE/GATE/PSU's/SSC-JE /State PSC JE/AE exams and Quality Control Engineer on Site.
Following content has been discussed in this video:-
#Measurement of #quantity of #track ballast and #gradation test of #ballast as per #RDSO GE1:2004 recommendations
RDSO GE1:2004- Specifications for track ballast.
RDSO- The Research Designs & Standards Organisation having Head Quarters in Lucknow.
GE- Geotechnical Engineering.
Size of box is 300 mm * 300 mm * 300 mm.
Subscribe my you tube channel for further updates / @yogeshkaushikcivil
Good night sir very good knowledge for ballast measurement given by you. Thanks
बहुत ही अच्छा वीडियो है फ्रेशर इंजीनियर के लिए
Thq for information sir, I hope keep it up like this videos we all inspired on ur videos
Very nice ballast measurement information Sir
Great way to learn thanku sir
Great
Gud job sir ji
Good
Very good information 👍 please explain with level instrumental Sama ballast measurements
Thanks for giving the wonderful information sir 🙂
Thank you sir 😊😊❤
Thanks sir...
Thankyou sir
What's size of box
Volume nikale to voids ratio kyo deduct nahi kare h?
Density is taken without considering voids
Voids deduction kitna karte hai isme
33%
Raiway track bed ki shear test kaise le sakte hai ?
By determining shear strength of soil of subgrade
Box ka weight deduct nahi karni hai kya sir ?
Starting me box ke weight ke sath zero reading set krte h
sample lene k liye panji ka nahi showel ka istemal hona chahiye q ki panji se fine part escape ho jate hai
Usse koi farak nhi pdta
Fine particles agr aa bhi jaye to vo sieve se pass ho jata h
Ballast ka Density Kay hota hai
1750 kg/cum.
Last me percentage ( %) kise nikale aapne
Cumulative nikala jata h
If any doubt remains, call me
Box kitne by kitne ka hai
300 mm*300 mm*300 mm
Measurement thik hai per greadetion sahi se nhi kia
Formula bataye ho nhi
How 20mm cumulative % 99.49
Not understood broo.
Dear learner
Kindly watch the video again for clear understanding of Table
If still not able to understand
Call me
Sir ulta kyu dikh raha hai
Screen reveresed