How to check fryer high limit tutorial DIY Windy City Restaurant Equipment Parts

Поділитися
Вставка
  • Опубліковано 21 сер 2024
  • Want to learn more about what a career in the trades can do for you, your kids, or your students? Check out blueisthenewwh...
    Want to listen on the go? Find all these videos and more on our podcast!
    perceptionevol...
    Spotify: open.spotify.c...
    FREE ACCESS TO OUR PREMIUM TUTORIALS "CLICK BELOW"
    www.windycitye...
    How to check fryer high limit tutorial. If your fryer is not working you can test the high limit. This do it yourself tutorial will help you repair fryer.
    FREE ACCESS TO OUR PREMIUM TUTORIALS "CLICK BELOW"
    www.windycitye...
    How to check fryer high limit tutorial. If your fryer is not working you can test the high limit. Windy City Restaurant Equipment Repair & Parts
    Tutorials, How to repairs, DIY repairs
    / windycityequipment
    / windycityequipment
    / windycityaz
    windycityequip.com
    Produced by : Craig Seidl
    www.craigseidl.com
    / seidlcorp
    SAFETY GUIDELINES AND DISCLAIMER
    www.windycityeq...

КОМЕНТАРІ • 83

  • @Jsuarez6
    @Jsuarez6 10 років тому +4

    I didn't hear you mention that the some high limits have a reset button. So it's not always necessary to replace the high limit, just press the button. On my Hobart CK40 there is a reset button on the high limit. Good video.

    • @Windycityequip
      @Windycityequip  10 років тому

      Jsuarez - You are absolutely right. I did forget to mention that in this video. Some fryers (Hobart, Pitco, Frymaster/Dean) have re-settable high limits that require you to press the button in order to resume operation. Footnote, if pushing the button doesn't work, you can use the same method in this video to check to see if it is good or bad. Thanks for watching and for pointing this out! I'll be sure to mention that if I do another video on high limits.

    • @fasdasdas12123
      @fasdasdas12123 6 років тому

      Hi. Sorry for the procedure to restart hi limit. I have Pitco 35C + S fryer

  • @Windycityequip
    @Windycityequip  11 років тому

    Keep your equipment running like new & watch our maintenance tutorials for proper upkeep on your restaurant equipment How to check fryer high limit tutorial DIY Windy City Restaurant Equipment Parts

    • @doanngyn
      @doanngyn 7 років тому

      Hi I have an imperial fryer and one of my contactors occasionally starts clicking rapidly for a few seconds. The tech support told me its a bad contactor so I ordered a new one and had it replaced. Occasional clicking still happening. Also I check my oil temp to keep it at 350 but at 350 my temperature knob is under 200. Any help is much appreciated. Cheers.

    • @doanngyn
      @doanngyn 7 років тому

      Also it's an Imperial IFS-40-E electric unit.

  • @Brian-qr6xi
    @Brian-qr6xi 6 років тому +1

    Both Tpile and Gas valve are brand new never used just installed

    • @Windycityequip
      @Windycityequip  6 років тому

      I know, I read that. I'm saying I've gotten defective parts many times before. Bad right out of the box. Also double check the wiring to make sure they are all attached to the correct terminals. If you want to send me a few photos I can confirm for you. Info@windycityaz.com

  • @sntlr87
    @sntlr87 Рік тому +1

    Does the high limit come on a new thermostat control or are they two different parts ?

  • @anandhuv2718
    @anandhuv2718 3 роки тому +1

    Very usefull 👍🏻

  • @wildthoughts6959
    @wildthoughts6959 3 роки тому +1

    What is the difference between Limit unit and thermostat? On parts .com , I see them identical except for the dial . The thermostat has a dial , limit does not. Does the fryer have both with two sensor copper wires ? Confusing. please explain, thanks. Fryer is Imperial IFS-40. thanks.

  • @AgustoRodrigues
    @AgustoRodrigues 2 роки тому

    Excellent short and very informative tutorial
    Can you please tell me on Vulcan fryer model 2VK45DF the fryer is not lightning at all

  • @jbarera
    @jbarera 10 років тому

    Nice Video, I just got a job at fastfood chain, I know Refrigeration system and they want me to fix those frymaster problem, Thank you for the vid

    • @Windycityequip
      @Windycityequip  10 років тому

      You're welcome! If there is anything else you would like to see here, please don't hesitate to let us know and we will do our best to produce it for you.

  • @kylelakota3437
    @kylelakota3437 4 роки тому +1

    my fryer wont reach past 280F, im watching all your videos but im not sure where to start ? help!!!!

  • @Brian-qr6xi
    @Brian-qr6xi 6 років тому +2

    Hi windy City,I've got a Vulcan EF4. I've replaced gas valve because I had no gas to pilot,got that lit,then wouldn't stay lit,so replaced Thermo pile now it stays lit, then replaced thermostat because I would turn on thermostat and pilot would quit....so new thermostat and it does the same thing,get it lit turn on thermostat and I hear a click in the gas valve and Everything goes out!! I'm frustrated. Now I've checked high limit after watching this. Do I leave any wires connected from Thermopile and thermostat while checking Ohms??? Please help me out with this. Thanks Brian

    • @Windycityequip
      @Windycityequip  6 років тому

      Hey Brian, I've seen this before. It sounds like you might have a defective thermopile or gas valve. Thermostat is easy to check. Remove the wires and check ohms across terminals only. Turn the tstat on and off. My guess is it's fine. Do you have another tpile you could throw in just to double check?

  • @lashanialoveof3803
    @lashanialoveof3803 Рік тому

    My fryer has blue in orange flames coming from the bottom in the top of the vent what can it be

  • @user-qm5tw6gp5c
    @user-qm5tw6gp5c Рік тому

    So basically if I’m getting resistance indicating the high limit is open, then it’s bad?

  • @ASP2850
    @ASP2850 6 років тому +2

    Is it possible to use a generic part and it still work correctly? I need my fryer fixed asap but the lead time for delivery is 15 days. I have an Atosa ATFS-40.

    • @Windycityequip
      @Windycityequip  6 років тому

      It is possible, but certain parts usually only work with certain "groups" of equipment. I tried looking up that model fryer and there's not a lot of information available since it's not a common brand. If I had to GUESS, I'd say the parts are probably similar to a Royal RFT-50 or Imperial IFS-40, but I can't make any promises on that since some manufacturers vary slightly in their designs. Wish I could help more, I'm sorry! My recommendation would be to buy the cheapest fryer you can find and throw it in storage as a backup. That way when you have issues with your main one you can at least still cooking while you're waiting on the repair. Thanks for watching Andrea.

  • @wildthoughts6959
    @wildthoughts6959 3 роки тому +1

    Hi, on Imperial IFS-40 , if I set temperature to 350, it works perfectly. If I set temp to 400, it works for few minutes then completely shuts off fire and pilot. I have to reignite the pilot . What could be the problem ? Thank you.

    • @ivansanchez6460
      @ivansanchez6460 11 місяців тому

      Have you Check thermostat calibration??

  • @jemibruri
    @jemibruri 4 роки тому +1

    Hi, can you explain how is the conection between high limit with thermostat and the valve? Or do you have a diagram conection ?. Thanks

    • @Windycityequip
      @Windycityequip  4 роки тому

      I can do my best to explain. Are you working with a Robert Shaw or a Honeywell gas valve (the fryer in this video was manufactured with both, depending on the year)? Let me know and I will try to get you a diagram. Thanks for watching!

    • @jemibruri
      @jemibruri 4 роки тому

      @@Windycityequip with a robertshaw

    • @yu-iw2pw
      @yu-iw2pw 3 роки тому

      did you have the diagram of the connections? could you share with me if you have, help me to fix my RobertShaw gas valve fryer problem

  • @johnryan9225
    @johnryan9225 Рік тому

    I have a 6 month carnival King fryer model #382DFCG32L
    I am getting a strong pilot light but goes out as soon as you turn on thermostat. Would a bad thermostats or hi limit cause that?

  • @jayvega3363
    @jayvega3363 3 роки тому

    Who tuned out and started singing? Hahaha puro norteños haha

  • @ronaldchan3401
    @ronaldchan3401 5 років тому +1

    Hi, I have a IFS-40, The pilot is on but as soon as I turn the temp dial from off to anywhere I hear a click than the pilot goes out and burner dont ignie. What is my problem here? Thank you

    • @Windycityequip
      @Windycityequip  5 років тому +1

      I've seen that problem many times. 9 times out of 10 it means that the thermopile is just barely generating enough mV to keep the pilot valve open, but as soon as there's additional load on the circuit (IE activating the tstat) it kicks off. I would start by replacing the thermopile (or testing it if you have a meter that reads mV) since it's the cheapest fix. If that doesnt fix the problem, it's most likely in the gas valve itself. Hope this helps, thanks for watching!

    • @mr2cqql
      @mr2cqql 5 років тому

      @@Windycityequip yes, you are right. I just changed it and it fires right up. Thank you very much for your great help, most importantly saved me some 💰 to have a service technician to come out for something as simple as this.

  • @kelliemorin4607
    @kelliemorin4607 4 роки тому +1

    My fryer is running very hot and there is soot not sure what or how to fix it? I have cleaned everything and it seems like a clog somewhere. Help I own i food truck

    • @Windycityequip
      @Windycityequip  3 роки тому

      Sounds like a gas flow or air fuel error. Check the burners for clogs, the flame tubes for blockages, and the flue for excessive carbon build up. Once you're sure everything is clean, you will be able to properly diagnose gas flow. Thanks for watching!

  • @twinkleho5111
    @twinkleho5111 2 роки тому

    Can you tell me what wrong with fryer the gas not back on when heat low

  • @ferminacosta2131
    @ferminacosta2131 3 роки тому

    Hello I have a pitco fryer. Model 14s Pilot stay on but fryer don't start. Any sugestions

  • @ashrafkarjiker6888
    @ashrafkarjiker6888 Рік тому

    How do you test the heating element

  • @marcogodinez5412
    @marcogodinez5412 6 років тому +1

    Hey if the hi limit is bad does the fryer will stop after 3 minutes? Everything including the pilot?

    • @Windycityequip
      @Windycityequip  6 років тому +1

      A bad high limit could absolutely cause this issue. You can confirm by testing continuity on the high limit right after the unit fails. Thanks for watching!

  • @HamariAwaaz-in5so
    @HamariAwaaz-in5so 4 роки тому +1

    My Henny Penny fryer pilot turns on but the main burner does not turn on.
    Yesterday, a worker drained the oil and by mistake turned on the main burner with empty well(pan) . He realised his mistake soon and he turned off the main burner. But when we tried to turned on the henny penny with oil in, its pilot turns on but the main burner does not turn on. I have tried to reset the high limit as well by pressing red button but still no success. Any advice please?

    • @Windycityequip
      @Windycityequip  4 роки тому +1

      When you press the red button, does it click? Depending on what model you have, there could be other safeties that need to be reset. Sometimes its in the controller. The drain switch could have been severed or knocked loose during the commotion. Check those things next and let me know. Thanks for watching!

    • @HamariAwaaz-in5so
      @HamariAwaaz-in5so 4 роки тому

      Many thanks for your reply, there is no click noise when I press high limit red switch. I checkes the continuity of high limit as well, it show reading on voltmeter. Also, resistance is shown on voltmeter.
      Drain switch looks like OK as it turns the light on.
      Model is Fastron Henny Penny?
      Any further suggestions please??

  • @leuktl
    @leuktl 5 років тому +1

    Hello, my Quest deep frying is having problem keeping the temperature, once it reach the set temperature, if the temp drops afterward, it won't come back on unless it is in MUCH lower temp. but if I lightly strike the gas pipe with a hammer, it turns on right away. Which parts of the failing do you think?

    • @Windycityequip
      @Windycityequip  5 років тому +1

      Well, its hard to say. My initial guess is that your gas valve is failing since they often stick and the pipe is connected directly to that valve. However the tstats sometimes begin to stick as well and they are very sensitive. The small vibrations in striking the pipe could be freeing that up as well. A good way to test would be to jump the top two terminals on the tsat momentarily before tapping the pipe. If it turns on, your tstat is bad, if it doesn't its most likely your gas valve. Just make sure you dont leave that tstat jumped, that would just be to test it. Good luck, hope this helps!

    • @leuktl
      @leuktl 5 років тому

      @@Windycityequip Thanks, I think that is it. Everything seems to work, just a sticky valve that needs a tap.

  • @eloingabriel7556
    @eloingabriel7556 6 років тому +1

    how can i test a high limit without wires only tube

    • @Windycityequip
      @Windycityequip  6 років тому

      Are you sure it's a high limit? A high limit is a switch so usually it has a circuit that it needs to break. Let me know what type of equipment it is on so I can understand a little better. Thanks!

  • @eddruff
    @eddruff 6 років тому +4

    Where did you find a clean dryer to work on?? 😂😂

  • @MrFabes23
    @MrFabes23 6 років тому +1

    Anets SLG40 - Pilot is lit, then goes out, and wont restart. I press the reset, and it lights up and I turn the tstat up to 325 and it stays on for about an hour, then turns off. I then cannot get the pilot light to stay on. After I release the Pilot switch from pushing it in, the pilot goes out after I release it about half way. I replaced the Gas Valve thinking it was the gas valve, but the same thing happens. I can't get the pilot to stay lit. Is this a Hi Limit issue or Thermocouple & pilot light issue? What do you suggest I do to fix so the pilot light stays on for more then 20-30 minutes?

    • @Windycityequip
      @Windycityequip  6 років тому

      It really could be either one, unfortunately. My recommendation, if you already changed the gas valve, is to replace the thermopile. If you have a multimeter that allows you to test mV, you can verify this. Otherwise, if you happen to have another fryer you can swap the thermopiles and see if you notice a difference. Have you noticed the temp of the oil getting excessively hot (smoking, smelling, etc)? If you have, then we may have to consider a tstat too. Let me know, we'll see if we can get to the bottom of it.

    • @MrFabes23
      @MrFabes23 6 років тому

      Is the thermopile and the thermocouple & pilot the same thing or 3 different things?

    • @MrFabes23
      @MrFabes23 6 років тому

      Thermopile, pilot, AND thermocouple have been replaced. I first tested the pilot to see if it stays on and it did. I then turned on the thermostat to 325 and it fired right up. After about 40-45 minutes, I checked back and no pilot and burners were off. Back to square one!!!
      I am wondering if it gets to temp and turns off everything as opposed to just turning the burners off and keeping the pilot on (cycling). Any thoughts?

    • @kingdurestaurant3726
      @kingdurestaurant3726 5 років тому

      MrFabes23
      i suggest you set temperature at 200 then use a temperature probe to see the actual temperature the oil is heated up to

  • @pare1000
    @pare1000 4 роки тому

    Hi changed the valve on imperial gas fryer but when I put on 350 its turn off the gas

    • @pare1000
      @pare1000 4 роки тому

      Its working on 250 bit over but not stopping the fair keep running gets over temperature

  • @Ken-ui2qe
    @Ken-ui2qe 7 років тому

    I have a Pitco SG14-JS, pilot goes on as well as burner but in the middle of start up cycle I get HEAT FAILURE and turns off. trips the high limit every time. When first problems started a day ago, it screen read HI with continuous beep. Guessing to replace the high limit?
    Thanks

    • @Windycityequip
      @Windycityequip  7 років тому

      It does sound like it could be the high limit. Or a problem in the circuitry somewhere. Usually heat failure doesnt occur before the high limit trips, but the SG14 is a very computerized unit. It could potentially be a computer board. If its a double unit you may want to try swapping the board with another unit (its just 1 plug) to see if the problem follows the board or stays in the original fryers. If it follows, you know you have a board problem. Hope this helps! Sorry for the delayed response!

  • @raviyadav8743
    @raviyadav8743 6 років тому

    I have frymaster fryer 3000 modle showing heating failure, replace gas valve.ignition assy, replaced infrared burner but still showing same problem.same vat right side burner glow very good.but left one.not glowing well.plz help me.

    • @Windycityequip
      @Windycityequip  6 років тому +1

      Check your ignition module and blower assembly.

  • @IK-rf2nz
    @IK-rf2nz 3 роки тому

    Ours read 0.9ohms. Is that bad?

  • @thuannhatn8074ever
    @thuannhatn8074ever 8 років тому

    Hello I have imperial fryer. It lid but when I set the thermostat to 325 degree it's get up to that point it's cut off plus it's cut off my pilot too. So do u think it my high limit is bad? Thank you...

    • @Windycityequip
      @Windycityequip  8 років тому

      It does sound like a high-limit issue if the pilot goes out as well. The important thing to do is take ACTUAL temp of the fryer oil while the unit is shutting off. If the oil is actually at 350 when everything shuts off, then a high limit is probably the culprit. But if the fryer is getting all the way up to 425 degrees before cutting out (even though its set to 350) then the problem is most likely in the tstat or gas valve. Hope this helps. Thanks for watching!

  • @doanngyn
    @doanngyn 7 років тому

    Hi I have an imperial fryer and one of my contactors occasionally starts clicking rapidly for a few seconds. The tech support told me its a bad contactor so I ordered a new one and had it replaced. Occasional clicking still happening. Also I check my oil temp to keep it at 350 but at 350 my temperature knob is under 200. Also it's an Imperial IFS-40-E electric unit. Any help is much appreciated. Cheers.

    • @Windycityequip
      @Windycityequip  7 років тому

      +Doan Nguyen contactor would have been my first instinct also, but considering that didn't solve your problem I would look at the thermostat. If your contactor is chattering that must mean the coil voltage is inconsistent. And that voltage is going to come from the tsat. Now it COULD be whatever component controls the power before it gets to the tsat too, but it should be easy to check. Test voltage before the stat and after. Try to isolate the power drop that way. Hope this helps a bit. Let me know the outcome. Thanks for watching!

    • @doanngyn
      @doanngyn 7 років тому +1

      Just swapped out the thermometer and it did the trick. Thanks a lot for the help!

  • @OllyDawson
    @OllyDawson 8 років тому

    Hi, thanks for making these videos. I was wondering how do you know if the high limit is not working? what will the test device do / not do ?

    • @Windycityequip
      @Windycityequip  8 років тому +3

      +Olly Dawson Well, first off, one thing the fryer WONT do if the high limit is bad is hold a pilot. The multi-meter should be set to "ohms" and have the "tone" turned on. If the meter emits tone on the terminals in the video, the high limit is most likely good. If not, the high limit is most likely bad. Hope this helps!! Thanks for watching!

    • @noels2995
      @noels2995 2 роки тому

      ​@@Windycityequip sss

  • @wht89gt
    @wht89gt 10 років тому

    How do I bypass the high limit

    • @Windycityequip
      @Windycityequip  10 років тому +4

      wht89gt - I am sorry, but I cannot advise nor can I tell you how to bypass a high limit. These are safety mechanisms that are nationally regulated by city and fire codes to ensure that the equipment does not start a fire. It is incredibly unsafe to bypass a high limit on a fryer and can be EXTREMELY dangerous because of how flammable the oil is.

  • @kylecarpenter6690
    @kylecarpenter6690 9 років тому

    may have just saved me a few hundred dollars..... thanks........... maybe ????...... lol

    • @Windycityequip
      @Windycityequip  9 років тому +1

      +Kyle Carpenter I hope I did. That is my goal! Thanks for watching!

    • @kylecarpenter6690
      @kylecarpenter6690 9 років тому

      +Windy City Restaurant Equipment Repair I replaced the thermocouple onmy Goldmedal 5099ns funnle cake fryer... Had checked my high limit via this tutorial.. and got tone.. but pilot still wont stay lit... cleaned pilot orifice and that seemed to help... but piolt just flickers as I hold in pilot button.. sasafty valve I guess wont stay open... So guess I am unfortunatly going to replace it now.....???... However this Fryer ( Propane ) calls for a 100# bottle where I am useing a 40# would this cause there to not be enough pressure in the lines to either not allow safty valve to stayopen or cause a flickering non working pilot ?

  • @vegaslowblower8781
    @vegaslowblower8781 4 роки тому +1

    I would like to understand the wiring better, But don't jave anyone to teach me

    • @Windycityequip
      @Windycityequip  3 роки тому

      You should be able to find the service manuals on Partstown. They often have the wiring diagrams as well.

  • @ladykimberlycleare809
    @ladykimberlycleare809 6 років тому

    My orfices keep catching on fire why is this

    • @Windycityequip
      @Windycityequip  5 років тому +1

      Usually this happens when there's a blockage in the burner or burner tube. Hope this helps! Thanks for watching!

  • @UmairKhan-zy8vk
    @UmairKhan-zy8vk 9 років тому +1

    hello sir I m umair form Pakistan working in suadi ara as kitchen equipment technician

    • @mkhan-ny6nq
      @mkhan-ny6nq 3 роки тому

      Hi, Any jobs available I'm a catering engineer in uk