Too good explanation buddy. One suggestion when you explain such videos kindly measurements and spacing into consideration it will make video more helpful for students
No... bottom distribution bars are not provided in case of two way slab .. because both the bars are main bar...chairs should be given maximum of 1 m distance in all directions
Sir,why do You not provide bottom distribution bar. Because opposite side of alternate crank bar is free,should we provide bottom distribution bar for that bar or not??
No... bottom distribution bars are not provided in case of two way slab .. because both the bars are main bar...chairs should be given maximum of 1 m distance in all directions
Very well explained, i am planning to build a commercial building soon so i am trying to learn a bit about building construction. i have watched many videos about building construction but yours is easiest to understand, thanks a lot. One last thing please dont put unnecessary music when you are talking. Thank you
Sir, मेरे घर मे छज्जा निकल हुआ है सिर्फ 1.5ft मगर मुझे छज्जा को 3 ft करना है और मेरे छज्जा मे बीम सिर्फ घर के अंदर तक है बाहर नही निकल है और मुझे 3ft निकलना है और उसपे एक किचन और दो अटाचा टॉयलेट और बाथरूम बांवना है, क्या करना संभव है
ਬੋਹੁਤ ਵਧੀਆ ਤੇ ਸਰਲ ਜਾਣਕਾਰੀ ਦਿੱਤੀ ਵੀਰੇ❤
watched so many videos to understand BBS.... but this video makes my day..... thanks for making this video....
Too good explanation buddy. One suggestion when you explain such videos kindly measurements and spacing into consideration it will make video more helpful for students
बहुत अच्छा लगा सर यह वीडियो 🙏🙏 🙏🙏🙏💕💕💕💕💕👍👍👍
Apka ek video ne mera pura doubt clear kar dala thankyou
Bahut hi acchi tarah se explain kiya hai, animation se samazane me asani hoti hai, nice video 😊😊
Very Well and Clearly Explained. God Bless You Sir.
Thank you
Clear and Cristal,but only one suggestion top distribution bars are alternative,one top and one bottom!👍
Nicely Understanding video
Thanks for making this video
Great 👍
Muze ye slab mesh ka sari dekhi videose jyada clear huva he ❤
Thanks for your clear explanation
बोत सरल समझाया🙏
Thanks Sir .....for 3d explaination very useful video
best explanation good luck
Bottom distribution bar not provided, is this not necessary??
Right sir your eyes is clear on
it's necessary
No... bottom distribution bars are not provided in case of two way slab .. because both the bars are main bar...chairs should be given maximum of 1 m distance in all directions
Bahut achha samjhate hai sir j aap thanks
Great Information 👍
Bilkul clearly samajh Aaya sir
Watched plenty of video for two way slab but you did world class explains 😊
Ultimate information
Salute you sir
Well explained 👍🏻
Well explained ❤❤
Thank you Bhai Mera to clear ho geya
Best Video on this topic. Thank you 🙏
Awesome explanation ...
Keep It up....
बहुत अच्छा
Your definition very good👍
Very good information.
Nice sirji I like this video 👍👍👍
Thanks you 🙏🙏🙏🙏
Thank u sir u explained very clear, and understandable way
Thanks 🙏🙏❤for detailing
beautiful animation bro
Curtailment of slab reinforcement kaise karte hai uspe ek vdeo banaiye please.. 🙏
Thank You Very Much
Good information thanks
Perfect!!
Great work
Nice information 👍
Very good vedio sir.
well explained , Thankyou so much
Nice video
One way slab ka bhi video bnaiye Sir.
thank you so much sir
Good sir
Super bhai
Best vidio sir 2 way salab
Great
Best explanation
👌👌
Mashaallah sir
very nicely explained
Phli bar samjh aaya
Very helpful
Osm
4 top distribution ke niche v dalna hoga
Thanks you
Very nice
Very good
It is very useful video thanks alot for this and requesting for more videos like this of pile cap and Pier cap etc .
1 no animation
Thanks 👍
جيد شكرا
Nice
Sir,why do You not provide bottom distribution bar.
Because opposite side of alternate crank bar is free,should we provide bottom distribution bar for that bar or not??
No... bottom distribution bars are not provided in case of two way slab .. because both the bars are main bar...chairs should be given maximum of 1 m distance in all directions
Nice sir
2way slab ke beem me kitne mm rod dena hota hai....?
Or slab me kitne mm ke rod dena hota hai.....?
Depends on load condition but in general you may provide combination of 12mm and 16mm
Bend up bar touch with top of beam bar or above, seen picture 1.5 inch above the beam top main steel, which is ok
see many video animations on slab rebar erangement but how you fix the shuttering and shoring up?
Slab ke liye thumb rule bata dijiye..
Or kitne distance pe kausa bar use kare
Can we use two way slab in load bearing brick walls?
Yes basically in 2way slab load is distributed along 4sides .
Yes if length to width ratio is less than 2.
sir, please make a video on curtailment system of slab reinforcement.
Measurement meter lena hai ya feet me
Very well explained, i am planning to build a commercial building soon so i am trying to learn a bit about building construction. i have watched many videos about building construction but yours is easiest to understand, thanks a lot. One last thing please dont put unnecessary music when you are talking. Thank you
Have you built
Wow sir
perfectly described
For explaining in 3d view may I know which software used?
You can use revit software
There is no distribution bar across the short span mainbar under bendup area
Mentioned
The non Bentup bars remains free at the ends.... IS it correct??
Top distribution bars ka kya spacing rakhna hai?
bottom extra bar nahi aaega? bending bar ke neeche
No need bottom distribution????
What about the bottom bars beyond in the cranked l/3 area? You didn't provide distribution bars for that one. Only for the middle part
25fit beam kon sa sariya and beam ki Hight and codai
What software using
Ismein chhajake liye double jali kaise dalen
Plz can u explain when to take l/5 and l/3
Is it called double mesh?
Yes
How can i get this software
bent done at l/4, which length called l? describe pl.
bottom me bhi spacing 300mm ho jata hai
usme bhi to extra bars provide karna chahiye
Sahi pakre hain😂
vay ap to ek room ka rod banding dekhariya, do room hogi to kashe kareyge
Top extra To aap NE diya but mera prasn hai uper To spase curect huyi but neeche ka bhag me to 300spece rahaga o dekhiye .
Bend UP me Down exra nahi dete kya
Why not bottom distribution bar
Sir maine crank bar both side band kr diya , pls reply
Sir pls reply
Pl clearfy about one way and tow way slab, there is doubt.
Bottom distribution bar?
Please design slab for room 14ft +14ft = 28ft , 14ft+14 ft= 28ft. And 2ft cantilever (28+2+2 = 32ft) .
Sir,
मेरे घर मे छज्जा निकल हुआ है सिर्फ 1.5ft मगर मुझे छज्जा को 3 ft करना है और मेरे छज्जा मे बीम सिर्फ घर के अंदर तक है बाहर नही निकल है और मुझे 3ft निकलना है और उसपे एक किचन और दो अटाचा टॉयलेट और बाथरूम बांवना है, क्या करना संभव है
Bent up bar ke niche kya aata h