Bar Bending Schedule of two way slab | bbs of two way slab | Engineering tactics

Поділитися
Вставка
  • Опубліковано 23 лис 2024

КОМЕНТАРІ • 312

  • @MohammedAslamtit-bitsoflife
    @MohammedAslamtit-bitsoflife 5 років тому +10

    Thank you very much excellent explanation..👍👍👍👍👍

    • @dreamdesign990
      @dreamdesign990 4 роки тому

      Check this Floor plan ua-cam.com/video/I5zRD7qzb-k/v-deo.html

  • @shivamsinghal345
    @shivamsinghal345 5 років тому +7

    Dear, i have seen a lot of videoes of many channels, but your two way slab video is better than any one.

  • @samsusamsu1978
    @samsusamsu1978 5 років тому +5

    Awesome explaination in a short period of time thanks sir

  • @aatifkhan3662
    @aatifkhan3662 5 років тому +3

    This one is thr Best video for bbs explanation i have seen till now...thanks☺️

  • @priteshramakantshah5550
    @priteshramakantshah5550 4 роки тому +4

    Very nicely you explained in this video it's very useful for supervisor and Forman on site ones again thanks sir

  • @eruc1675
    @eruc1675 5 років тому +1

    Sir apane bohot hi khoob bataya hai or itane kam samay me nice sir. U r great

  • @Motivation_By_SW
    @Motivation_By_SW 2 роки тому +1

    Sir excellent nice. Good explanation. God bless you.

  • @sindhublogsfoodeatingshow9736
    @sindhublogsfoodeatingshow9736 4 роки тому +2

    Thank you very much for explanation of barbanding sedule

  • @srinivaschoudhary321
    @srinivaschoudhary321 3 роки тому +2

    Super Explanation. kudos to you

  • @nagababuch9886
    @nagababuch9886 4 роки тому +3

    Superb... Explanation.....
    Wow ...🙏

  • @israengineerfouru5219
    @israengineerfouru5219 11 місяців тому

    Thank you so much brother for your kind efforts with sincerity

  • @deepanjanpal6014
    @deepanjanpal6014 2 роки тому +2

    Terrific explanation. Thanks

  • @technicalmusicmind6731
    @technicalmusicmind6731 4 роки тому +3

    3 points missing here... 1) Top extra bars not considered on all 4 sides
    2) clear cover not deducted
    3) 90 degree bend at both the side 2d not considered.
    Finally you have very good explanation skills good job

    • @kaakib8841
      @kaakib8841 3 роки тому

      3rd point is wrong .... They don't bend the bar of slab inside the beam its just straight
      (3) Where is the 90 degree bend ?

    • @brillientskillsfan4212
      @brillientskillsfan4212 Рік тому

      @@kaakib8841 ld kaha jaayega

    • @kaakib8841
      @kaakib8841 Рік тому

      @@brillientskillsfan4212 next slab mein.. Agar aage slab nhi hai to beam mein Ld

  • @harishdhawale7240
    @harishdhawale7240 3 роки тому +1

    Sir slab ke liye koi aisa ex pe video banao jisme ek slab mai two way bi ho aur one way bi ho.. toh slab ka sabse best video hoga..👍

  • @sodebujji5674
    @sodebujji5674 4 роки тому +2

    Thank you very much excellent explanation 👍

  • @Nikhil-kc4dd
    @Nikhil-kc4dd 4 роки тому +1

    Ur explanation skills are awesome

  • @PRASHANTKUMAR-kw8pw
    @PRASHANTKUMAR-kw8pw Рік тому +1

    Excellent explanation

  • @andytholung8896
    @andytholung8896 4 роки тому

    Bhai ekdam super clear xplain👍👍

  • @chaptersoflife78
    @chaptersoflife78 3 роки тому +2

    Cutting length pe development length add kre ya phir (clear span+beam widthx2-coverx2)add kre jo actual hay..pls tell..Continuous slab jb honge tb Ld hona chahie

  • @vikasbajabalkar9266
    @vikasbajabalkar9266 4 роки тому +3

    great explanation sir
    thanks a lot

  • @vilaspatil3148
    @vilaspatil3148 5 років тому +26

    What about extra top bar in short length area l/5 area all 4 sides

    • @Bkbaria1213
      @Bkbaria1213 2 роки тому +2

      Only bend up par extra top aaye ga..l/5 par

    • @bhargavrokad2647
      @bhargavrokad2647 Рік тому +1

      @@Bkbaria1213 pr two way slab me to dono side act karta heina bent up longer and shorter

    • @_miniDarling_
      @_miniDarling_ Рік тому +1

      did top distribution bars as top extra... misleading!

    • @mohammedfazal3011
      @mohammedfazal3011 Рік тому +1

      Yess. bro he shown calculation of top distribution bars .but but forgot to show top extra main bar only legend knowns

  • @nikhilmore949
    @nikhilmore949 2 роки тому

    What a video broo thanxx for your efforts

  • @RohitKumar-gg4cn
    @RohitKumar-gg4cn 3 роки тому +1

    Explanation bht badhiya tha ..maza aa gya

  • @zulfikarnadeem8254
    @zulfikarnadeem8254 4 роки тому +3

    Excellent explaination skill sir🥰🥰😘😘....keep going... Sir ...nd thank you very much for teaching us 😊😊

  • @erankitgupta7754
    @erankitgupta7754 5 років тому +1

    THIS VIDEO IS VERY USEFUL

  • @sunnyprajapati3654
    @sunnyprajapati3654 2 роки тому +2

    The spacing is 30cm in main bar and distribution bar

  • @bharathsurya188
    @bharathsurya188 4 роки тому +3

    Hello,I have a doubt while calculating no of main &dist bars Should we take the alternative sides or the same sides as u took.If so Why should we take alternative sides for cutting length calculation. Pls explain

  • @krunalyenurkar2262
    @krunalyenurkar2262 9 місяців тому

    Thank you sir for your kind information

  • @user-xg2bs7td5z
    @user-xg2bs7td5z 4 роки тому +2

    Sir 45 degree Crank bar bend of ke like apne 2 time multiple Kiya hai,, ishme total 4 go 45 degree banraha hai ek Crank bar me.... Pls explain sir why...
    Formula for cutting length of Crank bar.....
    ((Clear spain length + Ld + Crank -- bend)).

  • @seetaramampodicheti9758
    @seetaramampodicheti9758 5 років тому +1

    nice presentation very good

  • @vishaljadhav6075
    @vishaljadhav6075 3 роки тому +1

    Good information.

  • @boxerbullet6494
    @boxerbullet6494 3 роки тому

    Bai mein apki videos bhut pyar se dekhta hoon . Maine dekhna tab shuru kiya jab muje kush pta nahi tha apne ghar ko bnane ke liye plan bnane vaste. Tab apki videos ek vardaan sabit hoyi. Plz app ek video hum jaise aam logo k liye bhi bnao .ek andaza hi sahi magar man ka darr door ho jaye. Bahiya ameer log nahi hum bas ghar ko bnana chahtein hain. Length 50 feet aur bredth 30 feet hai front 23 feet x30 feet bacha hai 9 feet ka gate aur staircase bhi chahiye. Please advise bhut confuse hain .do bhai hai ek ke pass mata pita rehne hain liking abhi saath hai dono bai. Magar koi esa genious plan bna do bai agar kal ko shota bai alag rehna chahe to front 15 feet aur length 50 feet mean do portion ban jaye .dhanyavaad apka agar koi advise karein to

  • @romanansari8852
    @romanansari8852 4 роки тому +1

    Very good explanations sir.

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  4 роки тому +1

      Thanks

    • @romanansari8852
      @romanansari8852 4 роки тому

      @@ENGINEERINGTACTICS Sir beam ka bbs mein development length mein bend jo hota hai L-Shape mein wo minus nhi keeeye.

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  4 роки тому

      Beam k bbs k liye L-shape ko consider krna padta h isliye use minus ni kiya

    • @romanansari8852
      @romanansari8852 4 роки тому

      @@ENGINEERINGTACTICS tab Sir minus karegr tab galat hoga???

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  4 роки тому +1

      Ha minus kiye to galat hoga...q k beam ki jo cutting length nikalte hai to usme L ki length bhi consider rhti h

  • @siddarthk9583
    @siddarthk9583 5 років тому +2

    Super bro tq for giving such a useful vedio for us .... Now am subscribed after watching this vedio ...👌👌

  • @tycocapitalservice
    @tycocapitalservice 3 роки тому +1

    You are great ji

  • @Rajvlogs4047
    @Rajvlogs4047 Рік тому

    Nice information 👍👍🌺

  • @phyohtetkoko929
    @phyohtetkoko929 2 роки тому

    Thanks For Teaching Sir

  • @sekharcivil5269
    @sekharcivil5269 4 роки тому +1

    Good explanation bro

  • @tinycreaturezasmr5055
    @tinycreaturezasmr5055 3 роки тому +1

    Thank you my bro. 😇

  • @shivamsinghal345
    @shivamsinghal345 5 років тому +3

    Pls upload one video on staircase shuttering and reinforcement details.

  • @saifcivil5921
    @saifcivil5921 3 роки тому +1

    Bhoot badhiya

  • @suryapratapsingh5942
    @suryapratapsingh5942 3 роки тому

    Very nice explanation sir 💯

  • @Grace-bq3uc
    @Grace-bq3uc 4 роки тому +1

    Thank you for good explaining

  • @vishalbhatti2923
    @vishalbhatti2923 Рік тому

    Ex video bnana sir,how to calculate steel down beam in slab

  • @gurusharma2750
    @gurusharma2750 4 роки тому +1

    Hello why we add LD in both extra bar?..

  • @narayanbehera9347
    @narayanbehera9347 3 роки тому

    Continue slab ka bar placing and bbs with site visit ka ek vedio banaiye

  • @civilvibes8036
    @civilvibes8036 4 роки тому

    Nice sharing dear

  • @jaihind32949
    @jaihind32949 4 роки тому +1

    Dear, did you create microsoft Excel with formula. Just give few input parameter , it calculate every output. Pls share if you developed.

  • @vimalnath4419
    @vimalnath4419 5 років тому +4

    i asking one doubt bro ....torsional reinforcement details in two way slab & also site picture bro

    • @shobhanghorai6336
      @shobhanghorai6336 Рік тому

      50% of main bar in mid span is Torsional reinforcement .already 50 % povided in corner by alternate crank and distribution bar
      Some Cut pice is to provide at corner for torsional reinforcement

  • @arabindabehera54
    @arabindabehera54 5 років тому

    Thanks sir
    Plz make vedio about cast-in-situ pile

  • @vijayakanth3924
    @vijayakanth3924 6 років тому +2

    Super sir very usefull

  • @MDKHALID-vj5in
    @MDKHALID-vj5in 3 роки тому

    Sir joh ld mudega woh beam side se minus kar ke clear cover plus kar denge toh jitna ld modna h woh aa jayega slab ke liye

  • @chennareddyindla2349
    @chennareddyindla2349 2 роки тому

    Very very good.

  • @shafikkhan9803
    @shafikkhan9803 4 роки тому

    Good explanation

  • @chaushmohammed7044
    @chaushmohammed7044 4 роки тому +1

    Please post total station lecture

  • @kharunnissa3639
    @kharunnissa3639 Рік тому

    Thanku so much sir۔۔۔۔۔۔🙏🙏

  • @baiteshworward9225
    @baiteshworward9225 4 роки тому +1

    I think in top extra bar....cutting length of long and short bar is mistake and thats should be opposite.plz reply kya eh sai hai?

  • @rajusimmanuel3285
    @rajusimmanuel3285 2 роки тому +2

    Er. You are a talented person but why are you explaining it in top gear ?so now onwards kindly make it with slow speed thank you!

  • @civilsitewitherprithvi7566
    @civilsitewitherprithvi7566 4 роки тому +1

    Bhut axi video h

  • @blrmbhardwaj
    @blrmbhardwaj 5 років тому

    very good & clear

  • @heroking6175
    @heroking6175 10 днів тому

    Sir aapne explain to bahut accha kiya par main bar aur distribution bar ke dimensions ulte seedhe kar diye

  • @niraj4024
    @niraj4024 4 роки тому +1

    great video

  • @nileshsonawane324
    @nileshsonawane324 4 роки тому +1

    Sir continuous agr slab raha to next gale main bhi L/4 bar hum dalte hai ....to uska cutting length main L/4 add krna padega kya

  • @ashokdewangan1938
    @ashokdewangan1938 Рік тому

    top distribution bar cross section me crank bar k top me hona chahiye na ki bottom me ?

  • @hiteshbarkhane6320
    @hiteshbarkhane6320 3 роки тому

    Thankyou very much 👍👍❤️

  • @KALAISELVAN07
    @KALAISELVAN07 5 років тому +1

    Thanks bro subscribed and downloaded shared😀

  • @shivamsinghal345
    @shivamsinghal345 5 років тому

    Ok pls upload these videoes soon so that i can get as much as i can.

  • @jobinjohn1619
    @jobinjohn1619 4 роки тому

    perfect class thank you

  • @atuljha9813
    @atuljha9813 5 років тому +1

    Bro gud work!!!but isme 2 bend 90 degree bhi h..vo bhi deduct krne padenge..

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 років тому

      Hum isme alternative bent up bar use kiye h.....only one side bend provided

  • @shivamsinghal345
    @shivamsinghal345 5 років тому +2

    And also upload some column and footing layout drawings

  • @kamrankhan-qx6ks
    @kamrankhan-qx6ks 4 роки тому

    a o a sir many many of thanks really i learnt lot of this video . sir one thing i want to know if it is possible please tell and give the answer sir please tell me about column or beam because you took i think clear span in the comment please tell me

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  4 роки тому

      I didn't understand what u want to know about column or beam....tell me again...

    • @kamrankhan-qx6ks
      @kamrankhan-qx6ks 4 роки тому

      a o a sir 2 way slab if we have 4 sides we have beam & column you took clear span after that did you take lape 52 dia

  • @omairkhan_92
    @omairkhan_92 5 років тому +6

    Sir y didn't you take 2x of 0.42 as thr r two inclined bars

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 років тому +1

      There is no 2 times of inclined bar at the same bar..... There is alternative inclined bar, in one bar only 1 inclined length.

    • @avineshkumar1653
      @avineshkumar1653 4 роки тому +1

      But, 2 crank was there??

    • @archivisiondesignstudio1254
      @archivisiondesignstudio1254 4 роки тому

      @@avineshkumar1653 ha bro 2 crank h. Par bentups bhi alternative h na.. matlab jitne total no h usme se aadhw me hi h na.. isliye.. 2 way se equal hi hoga

  • @cartoonboy438
    @cartoonboy438 2 роки тому

    Sir without beem 2 way slam ka maximum size kya le sakte h

  • @akshitgarg3798
    @akshitgarg3798 3 роки тому +1

    why do you not provide clear cover in this?

  • @speedlighting-o8e
    @speedlighting-o8e 2 роки тому

    sir,in distribution bar cutting length,in crank
    deductions cover of two sides then 2 times of bar dia because distribution bar sitting over the main bar...am I correct or incorrect tell me

  • @arvindkumaryadav8814
    @arvindkumaryadav8814 3 роки тому

    Beam ke pass jo first main steel bar ki spacing beam se kitni hoti hai???

  • @santudatta9489
    @santudatta9489 9 місяців тому

    Sir ji double mesh slab ki bbs class ki ak video provide

  • @अंधभक्तकेचच्चा

    Thank u sir very very very thank u sir

  • @riteshkumar6300
    @riteshkumar6300 5 років тому +1

    Very good

  • @mychannel6560
    @mychannel6560 5 років тому +1

    Is development length is necessary if the slab is continuous i.e the bar is continious

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  5 років тому

      Yes it's necessary to take development lenght if slab is continues.
      Development length is provided for proper grip to the concrete and to prevent any slip of the bar from concrete.

  • @swapnilkhirawle4311
    @swapnilkhirawle4311 4 роки тому +1

    Bhai 8m ke span ki short extra bar ki length 8.64 kaise aayi? Utni cut hogi na?

  • @jayramray7682
    @jayramray7682 9 місяців тому

    Also consider the clear cover

  • @civilenggtech
    @civilenggtech 5 років тому +1

    Good Work,

  • @ramnathpatel9879
    @ramnathpatel9879 3 місяці тому

    Long & short bar me bend deduction krte h ki nhi

  • @latifurrahman2530
    @latifurrahman2530 3 роки тому

    Crank bar formula in feet system. 0.42d or changed.? Please inform me. Reply me.

  • @nripendardogra1187
    @nripendardogra1187 7 днів тому +1

    Thank you

  • @vharilalm
    @vharilalm 5 років тому +1

    Explained well, but you said binders as extra bar and you didn't took extra bar.

  • @shivamsinghal345
    @shivamsinghal345 5 років тому +1

    I am doing job in a big real estate company.

  • @mdfaizakram21db49
    @mdfaizakram21db49 2 роки тому

    Sir two ways slab ka many situations wala problem kijye

  • @educationhubpradip3130
    @educationhubpradip3130 4 роки тому

    Sir 18 by 16 ka room slab he kya reinforcement dena chahiy

  • @Waseemkhan-eq1xl
    @Waseemkhan-eq1xl Рік тому

    Good 🎉

  • @ritambhowmik1921
    @ritambhowmik1921 5 років тому +1

    Sir,crank bar jab alternate hota hai tab top or bottom Mai spacing bar jata hai keya?

  • @lokwanijay6977
    @lokwanijay6977 3 роки тому

    Sir I have question in the no of main bars calculation considered lenth longer span is 8000mm but when cutting length of main bar calculation why take shorter span length 6000mm..?

    • @kaakib8841
      @kaakib8841 3 роки тому +1

      Drawing (diagram) dekho samajh jaoge.
      No. Of main bar = 8000/spacing + 1
      No. Of distribution = 6000/spac + 1
      1st main bar 8000 k ek kone se rekhna start karenge aur last main bar 8000length k aakhiri kone pe rakhenge.
      Par bar ki placing (bar ki length) 8000length se perpendicular hogi i.e short span pe aayegi main bar (fig. mein dekho to samjhega)

    • @lokwanijay6977
      @lokwanijay6977 3 роки тому +1

      @@kaakib8841 Thank you so much brother for replying and give valuable information and explaination.👍🙏

  • @pulkitsharmabest4ever670
    @pulkitsharmabest4ever670 4 роки тому

    Isme slab beam ka reinforcement quantity n chajja ki quantity bhi include h kya sir.

    • @ENGINEERINGTACTICS
      @ENGINEERINGTACTICS  4 роки тому +1

      Nahi...isme sirf slab ki quantity hai....beam ki alag se nikalte h or chhajje ki...ye srif slab ki hai

    • @pulkitsharmabest4ever670
      @pulkitsharmabest4ever670 4 роки тому +1

      @@ENGINEERINGTACTICS to sir beam or chajja ki sath m btao help hogi jyada sbki

  • @wonderingcivil8808
    @wonderingcivil8808 2 роки тому

    Super thanks

  • @sheikali2376
    @sheikali2376 3 роки тому

    Wht hpn when main steel is provided in long span ?? ('Mistakenly)

  • @SM_Happy143
    @SM_Happy143 3 роки тому

    Cutting length me cover deducted nahi hoga Kaya !

  • @Grace-bq3uc
    @Grace-bq3uc 4 роки тому +1

    Good

  • @orophile_awlan
    @orophile_awlan 6 місяців тому

    Isnt main bar along shorter span.?

  • @Faisu_shorts1008
    @Faisu_shorts1008 Рік тому

    Bhai plzzz overhead tank ka aise hi copy pe bbs bna do kyuki up me jal jeevan mission hi chal rha
    Raft ka bbs top dome ka conical wall ka bottom dome ka plzzz bbs bnayea