I/O on Demand-Electronic Marshalling

Поділитися
Вставка
  • Опубліковано 24 лис 2024

КОМЕНТАРІ • 27

  • @krislyttle
    @krislyttle 7 років тому +2

    Neat idea! Essentially, each of these characterization modules is a user-definable I/O point-terminal block combo unit, with each baseplate in the stack playing the role of an I/O "cluster" module; there is no longer a need for a 16-point DI or DO module in a PLC chassis, and then a rats nest of wiring connecting them to TBs, for example.
    Well done, Emerson!

  • @jerryjoynson
    @jerryjoynson 12 років тому

    This is a very elegant improvement that the processing industries need more of.

  • @eiriksiljan2905
    @eiriksiljan2905 5 років тому +1

    Excellent demonstration!

  • @putatundakanad
    @putatundakanad 13 років тому +3

    Great to see such innovation.....will soon be emulated by other DCS majors

    • @Techwem
      @Techwem 3 роки тому

      We have also videos related to many DCS systems specially DeltaV.
      Do visit and subscribe to our channel.

  • @chriswhite5601
    @chriswhite5601 9 років тому +1

    Very nice indeed! Seems great and so simple!

  • @brightness4195
    @brightness4195 5 років тому +1

    this excellent, how can the DCS channel changed without changing the wire in case of a channel fault?Is it certified to use in SIS systems?

  • @keshavgokhaledivine
    @keshavgokhaledivine 6 років тому

    Can I use this system for a big control panel having 6000 IOs?

  • @alijaber4500
    @alijaber4500 3 роки тому

    I can use DI and DO on the same base plate

  • @EnriqueGarcia25
    @EnriqueGarcia25 7 років тому

    If the charms can be placed in the field, do you then run individual cables to the DCS or a home run cable?

    • @dantheautomationman6959
      @dantheautomationman6959 5 років тому

      From the CIOC you can run either a fibre optic or CAT5e, depending on the module you pruchase, to your DeltaV primary and secondary network.

  • @vanrajsindha130
    @vanrajsindha130 5 років тому

    isolation barrier function include in CHARM ? there is no need isolation barrier?

    • @dantheautomationman6959
      @dantheautomationman6959 5 років тому +1

      With Intrinsically safe CHARMS you do not need a external barrier.

    • @jayaprakashsworldtraveler8726
      @jayaprakashsworldtraveler8726 3 роки тому

      @@dantheautomationman6959 Not Required. Its inbuild in the CHARMs.
      Thanks, Jayaprakash Solaraju
      Mail- Jayaprakash.DeltaV@gmail.com

  • @siomai.rice07
    @siomai.rice07 Рік тому

    Whats inside tho..

  • @patelhiren5320
    @patelhiren5320 6 років тому

    Nice video

    • @Techwem
      @Techwem 3 роки тому

      We have also videos related to many DCS systems specially DeltaV.
      Do visit and subscribe to our channel.

  • @MahalingasivamYogavarathan
    @MahalingasivamYogavarathan 11 років тому

    Great :)

  • @Kayodethegrapher
    @Kayodethegrapher 6 місяців тому

    14years ago

  • @sidhusharmasidhusharma7630
    @sidhusharmasidhusharma7630 6 років тому +1

    Hello dear sir how are you i am working Emerson in Saudi Arabia

    • @samirghedjati4024
      @samirghedjati4024 6 років тому

      Hello, May I contact you in privet?

    • @Techwem
      @Techwem 3 роки тому

      @@samirghedjati4024 We have also videos related to many DCS systems specially DeltaV.
      Do visit and subscribe to our channel.

  • @oiramgali
    @oiramgali 9 років тому

    hi

  • @elkhunter307
    @elkhunter307 2 роки тому

    Except you stopped making charms and now have an 18 month lead time delaying and causing massive headaches for refiners across the country….. what a cluster. Great work and planning.🤦🏻‍♂️