How to troubleshoot Fujitsu DC inverter indoor unit blinking.

Поділитися
Вставка
  • Опубліковано 7 вер 2024
  • Brand : Fujitsu DC inverter
    model : AOAG24LAT3 multi split system 3
    error code : 76 (operation light blink 7 times, timer light blink 6 times and economy light continuously blink)
    Cause : 2 & 3 way valve thermistor faulty.
    Thermistor reading: around 38 K ohm at ambient temperature around 30°c
    #bonmj #inverter #fujitsu

КОМЕНТАРІ • 119

  • @cliffdespeaux6949
    @cliffdespeaux6949 Рік тому +5

    Thank you for posting this video. It saved me $15,000! I had a local HVAC company come out and they charged me $200 to say my unit was fried and I needed a whole new install. Thanks to your video I tried replacing the probes myself and... it works now!

    • @BonMj
      @BonMj  Рік тому +1

      Nice to hear that.👍👍👍

    • @Benji826
      @Benji826 Рік тому +2

      Hi there! We are having the same problem. Can you let me know where you found the actual parts. I've been looking everywhere, with no luck.

  • @doronzemach3959
    @doronzemach3959 Рік тому +2

    I bought the two parts and the technician replaced them. It solved the issue. Thanks again for saving me so much money.

    • @BonMj
      @BonMj  Рік тому

      👍👍

    • @fivestarbrokerage
      @fivestarbrokerage 3 місяці тому

      Hello @doronzemach3959 can you let us know where you bought this part?

  • @neilkirby-xg9ts
    @neilkirby-xg9ts Рік тому +1

    Thank you for posting!! One service company wanted to replace my entire unit. Called in another company - mentioned these two parts from your video and they agreed that was the problem. Saved me a lot of money!!

  • @hvac01453
    @hvac01453 Рік тому +2

    Great job. With these minis, it was nice you identified the parts where they were located. In those tight compact units its sometimes hard to see where things are located. Good camera work.

  • @capitalductless4556
    @capitalductless4556 2 роки тому +3

    Bon,
    A lot of misunderstanding on inverter/ mini split style units here in the US- nice to see a channel that addresses troubleshooting and repair with these with more than just “replace the outdoor unit” mentality.

    • @BonMj
      @BonMj  2 роки тому

      Thanks

    • @reubenbugeja4066
      @reubenbugeja4066 2 роки тому +1

      I just wish in my country we had that luxury!!!!! A 3 way multi split outdoor unit is not a cheap thing!!!! Most probably in my country costs over 2K!
      2 weeks ago i went to diagnose an air conditioner,outdoor pcb board was the culprit. (18kbtu hitachi inverter split unit,Not more tham 4 years old) Called local hitachi authorized seller and quoted me that the replacement outdoor pcb board is 600$!!! not including labour!!!! As soon as i told the customer, he told me replace the hole thing. a brand new 18k gree with 5 year warranty only costed him 900$. but by the way thanks a lot Bon for sharing your experiences.

    • @BonMj
      @BonMj  2 роки тому

      @@reubenbugeja4066 Thanks bro

  • @edzelperocho2250
    @edzelperocho2250 2 роки тому +1

    thanks sa video sir....malaking bagay po sa mga aircon tech..

  • @davidraulesquivel9278
    @davidraulesquivel9278 2 роки тому +1

    T'hanks for your videos,they are very Well explained
    👏👏👏

    • @BonMj
      @BonMj  2 роки тому +1

      Thanks

  • @abidshirhatti6815
    @abidshirhatti6815 2 роки тому +1

    Bast information video sir

    • @BonMj
      @BonMj  2 роки тому

      Thanks

  • @doronzemach3959
    @doronzemach3959 Рік тому +1

    Hi. I have the same issue, very helpful video

  • @user-kd2xw8kt7j
    @user-kd2xw8kt7j Рік тому +1

    Thanks I'm working on an aou24rml1 with code 6 at led 1.
    I will test thermistor

  • @janshaw5472
    @janshaw5472 2 роки тому +1

    谢谢Mr bon 最疼头fujishu 哈哈😄

    • @BonMj
      @BonMj  2 роки тому

      谢谢你。

  • @mustangpunchguzman1053
    @mustangpunchguzman1053 Рік тому +1

    Great video well splain

    • @BonMj
      @BonMj  11 місяців тому

      Thanks

  • @user-ud5co9yr3k
    @user-ud5co9yr3k 9 місяців тому +1

    Hi and thanks you for thé content that you présent, I have a question about Atlantic, what causes thé fault 77? Thank you so much.

  • @Chasethisbread
    @Chasethisbread Рік тому +1

    This guy. Legend.

  • @HVACSystem
    @HVACSystem 2 роки тому +1

    Good work sir

    • @BonMj
      @BonMj  2 роки тому

      Thanks bro

  • @xutao9621
    @xutao9621 Рік тому +2

    Hi, thanks for sharing. My Fujitsu multi split system has the same error now. Where can I buy these valve thermistors?

    • @BonMj
      @BonMj  Рік тому

      From Fujitsu (Winfinity Singapore Pte ltd)

  • @suhaimizainalabidin3685
    @suhaimizainalabidin3685 2 роки тому +1

    Good job sir👍👍👍

    • @BonMj
      @BonMj  2 роки тому

      Thanks

  • @JuanTodoli
    @JuanTodoli 2 роки тому +1

    Excellent 👌

    • @BonMj
      @BonMj  2 роки тому

      Thanks

  • @chandarasena
    @chandarasena 7 місяців тому +1

    Hi Mr. Bon I like your instruction very much. what country are you from, Thailand?

    • @BonMj
      @BonMj  6 місяців тому

      Singapore

  • @hasanmdkamal1010
    @hasanmdkamal1010 2 роки тому +1

    Good job..bro

    • @BonMj
      @BonMj  2 роки тому

      Thanks

  • @reubenbugeja4066
    @reubenbugeja4066 2 роки тому +3

    thanks a lot Bon for sharing your experience! do you know any online shop for ac spares?

  • @salamsaloom2477
    @salamsaloom2477 10 місяців тому +1

    👌👌👌👌👌👌

    • @BonMj
      @BonMj  10 місяців тому

      Thanks

  • @Zawkyi-4466
    @Zawkyi-4466 Рік тому +1

    Thank U

  • @reginaldfrancis73
    @reginaldfrancis73 4 місяці тому +1

    Hi Bon, can you suggest fluke multimeters model good to troubleshoot thermistor and control board and power board

  • @stevealoia
    @stevealoia 2 роки тому +1

    Hi Bon. I’m working on a 24000 btu now with the 7 and 6 code . When testing the thermistor for Aand B it ohms out at 97.5 with a out side temp of 50 degrees and the C ohms out with OL and 38.0 ohm are both bad . Thank you

  • @welcometomydreamworld6812
    @welcometomydreamworld6812 2 роки тому +1

    I hope you will update the next thank you👌

    • @BonMj
      @BonMj  2 роки тому

      Thanks bro

    • @BonMj
      @BonMj  2 роки тому

      @lee Le bonmj81@gmail.com

  • @techigirl1techigirl13
    @techigirl1techigirl13 Рік тому +1

    Hi Bon. This is an excellent video, very informative.You explain things very clearly and thoroughly, step by step. My question is I have the same 7 6 error code but a different model number than the one in your video. Is my issue the same? My model number is AOU24RLXFZ. Thank you for your help.

    • @BonMj
      @BonMj  Рік тому

      Should be the same

    • @techigirl1techigirl13
      @techigirl1techigirl13 Рік тому

      @@BonMj Great! Thank you so much! I really appreciate your help!

  • @karaors8970
    @karaors8970 2 роки тому +1

    hi bro süper jop 🛠️🤳👍🇹🇷

    • @BonMj
      @BonMj  2 роки тому

      Thanks

  • @8bunker
    @8bunker 2 роки тому +1

    thanks men

    • @BonMj
      @BonMj  2 роки тому

      Welcome

  • @BayleyBuzz
    @BayleyBuzz Рік тому +1

    Hi, thanks for your video, very interesting. I have an identical unit that stopped working tonight. I have traced the power back to the head unit but no lights on head unit. Remote is working correctly on other unit. Head unit start no go. Is it likely to be the small 3.15amp fuse on the PCB in the head unit? Do you know what would cause it to blow. Many thanks.

    • @BonMj
      @BonMj  Рік тому

      May be cause by Fcu fan motor

  • @seanazma3441
    @seanazma3441 2 роки тому +1

    U da man

  • @welcometomydreamworld6812
    @welcometomydreamworld6812 2 роки тому +1

    Thnxx u Sir

    • @BonMj
      @BonMj  2 роки тому

      Thanks

  • @Benji826
    @Benji826 Рік тому +1

    This video is incredibly helpful. We are having the same problem. Do you have a link to a website where we can buy the 3 way thermistor and 2 way thermistor? I have been searching for 2 days now, and can't find the part number or anywhere that sells the part.

    • @BonMj
      @BonMj  Рік тому

      Contact nearest Fujitsu

  • @edwinneilnovoa1047
    @edwinneilnovoa1047 2 роки тому +1

    Hola amigo bom si espocible en español gracias amigo bom dios lo bendiga

    • @BonMj
      @BonMj  2 роки тому

      Thanks.
      Can you write in English

  • @hasandogan7174
    @hasandogan7174 Рік тому +1

    Merhaba Fujitsu general vrf gaz toplama vacum modu hakkında bilgi alabilirmiyim lütfen

  • @francis_Teo_KY
    @francis_Teo_KY 2 роки тому +1

    If its outdoor like my house. Hanging at high level. How? U able to fix?

  • @Lim-eh9yi
    @Lim-eh9yi 2 роки тому +1

    Boss can share if vrv3 outdoor icing problem.

  • @lookoutleo
    @lookoutleo 10 місяців тому

    Hi my Fujitsu mini split looks like yours but my fault is one flash top light the one flash middle light and bottom light flashing fast. I've been told it's no communication between inside and outside units . Can you help?

  • @johnnyroxannebautista2063
    @johnnyroxannebautista2063 2 роки тому +1

    Hello Sir bon,do you have a vlog on LG unit vrf?

  • @muruganantham595
    @muruganantham595 2 роки тому +1

    Can we bypass the 4 way valve in Fujitsu , can you please tell about the 4 way valve error .

    • @BonMj
      @BonMj  2 роки тому

      This 2 way and 3 way valve thermistor- is only thermistor, not valve.
      4way valve is different,4way valve is heat and cold exchange valve

  • @geethperera9052
    @geethperera9052 2 роки тому +1

    I like to joing with you sir

  • @svengineering673
    @svengineering673 2 роки тому +1

    bro bon make a video on brazing hard drawn pipe with full details

    • @BonMj
      @BonMj  2 роки тому

      Thanks

    • @geethperera9052
      @geethperera9052 2 роки тому +1

      @@BonMj i like to learn mitsubishi vrf.your kowledge is best

  • @brendenbanks9293
    @brendenbanks9293 Рік тому +1

    Could use some help. I have three heads... two wall units and one ceiling cassette. The ceiling cassette blinks green x3. No other lights just 3 blinks then maybe 15seconds of nothing.
    I cannot find any error list that this aligna with. Units are blowing warm. I assume I have a slow leak but want to understand what 3 green blinks mean before I call someone out to recharge it.

    • @BonMj
      @BonMj  Рік тому +1

      Reverse comms fail in use

    • @brendenbanks9293
      @brendenbanks9293 Рік тому

      @Bon Mj yeah that's what i was finding as the error code too. Does it make sense that only one unit is blinking and the system isn't cooling? I would think the other two units would still be working and blowing cold? Or does the one unit bring down the whole system?

  • @martinharry-on6bt
    @martinharry-on6bt 7 місяців тому +1

    Please I need help on AOTG45LATL fugitsu duct ac the outdoor running for 10mins and cuts out..why is that? And there's no error code appearing on control screen and outdoor error led not giving any sign..

    • @BonMj
      @BonMj  7 місяців тому

      Compressor working?

    • @martinharry-on6bt
      @martinharry-on6bt 7 місяців тому

      @@BonMj yes compressor working and overheating after ten minutes..

  • @danielguo1033
    @danielguo1033 Рік тому +1

    Are you in NSW Australia?

  • @danielmovie
    @danielmovie Рік тому +1

    Hi I have Fujitsu investor problems is all indicators lamps blinking, cam you help me find out problem?

    • @BonMj
      @BonMj  Рік тому

      May outdoor unit got problem

  • @yewkey88
    @yewkey88 Рік тому +1

    My unit aotg45latl showing err 00:11, serial com.error. what should i looking for. Thanks Bon

    • @BonMj
      @BonMj  Рік тому

      What brand? Fujitsu?

    • @yewkey88
      @yewkey88 Рік тому +1

      @@BonMj yes, thanks

  • @rebecamorales7089
    @rebecamorales7089 2 роки тому +1

    Hi Bon I have a Fujitsu Haclyon and shows 9 operation blinking and 9 red light blinking. Can you help with this? Thanks

    • @BonMj
      @BonMj  2 роки тому +1

      Suggest check outdoor thermistor and check gas pressure

    • @rebecamorales7089
      @rebecamorales7089 2 роки тому +1

      @@BonMj thanks for the help.

    • @BonMj
      @BonMj  2 роки тому

      @@rebecamorales7089 welcome

  • @rahmananisur5474
    @rahmananisur5474 10 місяців тому

    Hi brother
    My one fujisu unit indoor operatin there red light come I want to know what the root cause please help me

  • @samqsj
    @samqsj 2 роки тому +1

    Hi my fujitsu inverter has the same error code. Can you help fix it? How much will be?

    • @BonMj
      @BonMj  2 роки тому

      Thanks watching my video.
      You can contact this no. 62881288

  • @bpicoy2k
    @bpicoy2k Рік тому +1

    I just replace the valve thermistor C and D, and the unit wont turn on. I've reset the power multiple times, nothing seems to work. Help!!

    • @BonMj
      @BonMj  Рік тому

      Do you check other thermistor reading

    • @bpicoy2k
      @bpicoy2k Рік тому +1

      @@BonMj yes I did and one of the 3-way thermistor was bad, in addition it turned out one of the fuse (250V 10A) blown out. I replaced the fuse and reset the power and all working like a charm again. Thank you so much!

    • @BonMj
      @BonMj  Рік тому

      @@bpicoy2k welcome

  • @sfchannel764
    @sfchannel764 2 роки тому +1

    What is the function 2 way and 3 way valve thermistor sir?

    • @BonMj
      @BonMj  2 роки тому

      Pipe Thermistor normally control cooling.
      2way or 3 way just a name for the parts

    • @sfchannel764
      @sfchannel764 2 роки тому +1

      @@BonMj oh i see sir, thank for answering questions sir👍

  • @desafio78
    @desafio78 2 роки тому +1

    Hi, my error code is operation 7, timer 1. What is the actual issue and how much if fix?

    • @BonMj
      @BonMj  2 роки тому +1

      Discharge temperature sensor

    • @desafio78
      @desafio78 2 роки тому

      Can u fix it? And how much?

  • @thesmallie99
    @thesmallie99 2 роки тому +1

    Where can I buy the thermistor?

    • @BonMj
      @BonMj  2 роки тому

      Fujitsu

    • @thesmallie99
      @thesmallie99 2 роки тому +1

      I live in US and they make it extremely hard to buy these hvac parts. Do you have a specific website that might be willing to ship to us?

    • @BonMj
      @BonMj  2 роки тому

      @@thesmallie99 www.fujitsu.com/sg/#global-nav

  • @kashibaba521
    @kashibaba521 Рік тому +1

    Error code 76 Thermistor faulty

  • @Lee-mu2jc
    @Lee-mu2jc 2 роки тому +1

    老板晚上好不好意思打扰你,请问可以麻烦你给我这个fujitsu dc inverter error code menu吗?谢谢你

  • @Lee-mu2jc
    @Lee-mu2jc 2 роки тому +1

    老板不好意思请问可以给我这个fujitsu error code menu吗?谢谢你

    • @BonMj
      @BonMj  2 роки тому +1

      我找一下,没问题

  • @user-up4pb9cs4m
    @user-up4pb9cs4m Рік тому +1

    Hi, my fujitsu has error code 33? Operation 3x and Air Clean 3x. It has 2 units. Do I just change the 3-way valve temperature thermistor?

    • @BonMj
      @BonMj  Рік тому

      May outdoor temperature sensor