How my inverter is hooked up in split phase

Поділитися
Вставка
  • Опубліковано 18 жов 2024

КОМЕНТАРІ • 40

  • @yadrielgonzalez1
    @yadrielgonzalez1 3 роки тому +1

    Very nice explanation. Thanks for sharing your knowledge.

  • @2ndamendment770
    @2ndamendment770 Рік тому

    Good Presentation sir ! > I'm curious as to what or which Brand of inverter your using ?

  • @r.b.r9558
    @r.b.r9558 4 роки тому +2

    About time somebody do a video like this one thank you very much

    • @ajarivas72
      @ajarivas72 3 роки тому

      I just was thinking about this and UA-cam recommended the video. They read your mind.

  • @stevelamperta865
    @stevelamperta865 3 роки тому +1

    I didn't realize this was going to be a safety video !!!

  • @sfkenergy
    @sfkenergy 2 роки тому +2

    Hello, how about using an automatic transfer switch to prevent the back feed issue you have described?

    • @usphisics
      @usphisics Рік тому

      I was thinking the same. Can we have a auto transfer switch on it ?

  • @tjhouston4916
    @tjhouston4916 5 років тому +2

    Thanks for the info. Very helpful.

  • @WiSeNhEiMeR-1369
    @WiSeNhEiMeR-1369 2 роки тому

    HOWdy Gen,
    Thanks
    COOP
    ...

  • @marktheunitedstatescitezen185
    @marktheunitedstatescitezen185 3 роки тому

    Thank you - I have the 5KVA 230v PureSineWave Inverter Charge Controller Unfortunately the inverter is only L-1- 230v / 76A at 3 Kw & at 5 Kw it produces 96A still at 1 leg of 230v it’s a hybrid Inverter I planned on wiring it the same way but to a 100A Double Pole Breaker , I have the 10’ 3/4 grounding rod , also Have The duplicate home line breaker box I’ve been debating on wiring over only the circuits that we use in a grade down situation skipping the hundred amp double pole breaker and wiring the second electrical box For the youth only of course shutting off the two lines coming from the street To the first breaker box I have the Moles automatic transfer switch , my battery bank is 48 V 15 3.2 V 280 amp hour batteries and 21 lithium Titanite 2.3v Coke bottle batteries 40 amp hour I have a couple cheap solar panels I got off wish only use for dire need 25 V amperage is very low “ car alternators create AC current and then switch it over to DC current tap and the alternator before it switches the AC current over to DC you have yourself a generator that will literally last 150,000 miles driving look it up , just survive in the bush sometimes you got to act like a backyard mechanic thinking out of the box ! Thanks for the video education that you’ve taught me just reassuring what I thought I could do !

  • @juliocolon5983
    @juliocolon5983 3 роки тому +1

    Please give more información of the neutral or ground instalation

  • @quickquote1568
    @quickquote1568 Рік тому +1

    You've wired this up in a very dangerous and illegal manner. You should have used an automatic transfer switch. Never, ever wire the output of an off grid inverter or a generator to your main panel by relying on remembering to shut off the main breaker first. Doing so will always, eventually lead to someone forgetting to shut off the main breaker first which will result in a potential fire.

  • @defjamsgreen
    @defjamsgreen 5 років тому +3

    LIKE THE VIDEO . THATS HOW I KIND OF STARTED MY HOOKUP WHEN I,VE STARTED MY SETUP .THEN IT CAME UP TO THE TIME I NEEDED TO BUY A TRANSFER SWITCH BECAUSE SOMETIMES LIKE YOU SAID IT ONLY TAKE ONE TIME TO FORGET TO SWITCH OFF THE MAINS OR DIDN'T SYNC THE SWITCHING THAT WOULD DESTROY THE INVERTER OR CREATE AN ELECTRICAL DISASTER . I WAS CAREFUL THAT IT NEVER HAPPEN TIL I'VE BOUGHT A TRANSFER SWITCH FOR MY SETUP FOR A SAFE GRID TRANSFER . I DID SOME RESEARCH AND IT WAS A SUCCESSFUL HOOKUP .YOU CAN WATCH MY VIDEO CALLED " MY TRANSFER SWITCH HOOKUP " AND MY OTHER VIDEOS LEADING TO IT . PLEASE SHARE , AND LEAVE YOUR COMMENTS AND OPINION ABOUT IT . THANKS .

  • @buickgs8880
    @buickgs8880 4 роки тому

    hello , thanks for the video , i have a question - my is a 5KVA 230v Pure Sine Wave charge controller 48v - how to divide 230v to 2-115v i have a 100 Amp 2 pole breaker , this inverter is listed 96A & i'm creating a DIY generator a Gm 10 SI B.B. slow turn charging high Amp and i've tested off the stator the copper winding Ac current 1980v Amps i have not tested although someone else has on youtube and he said he's tested 90Amps @ 115v

  • @freetrailer4poor
    @freetrailer4poor 5 років тому

    This is my dream inverter

  • @marktheunitedstatescitezen185

    On my 5KVA 230x1 93A I bought a SIEMENS MTO 100A Transformer intake

  • @drummerboy2521
    @drummerboy2521 2 роки тому

    Someone can switch it on by mistake when you're not there. How about an automatic transfer switch?

  • @thereynolds2725
    @thereynolds2725 3 роки тому +4

    No connector on the seal tite. No ground to the inverter. Green neutral. Eaton breaker in a GE panel.

  • @carlosreyes6448
    @carlosreyes6448 3 роки тому

    How big is your solar array?

  • @jamesgarage4327
    @jamesgarage4327 3 роки тому

    I’m not an electrician, but I’m thinking the third wire should go to the neutral - not the ground

    • @bicylindrico
      @bicylindrico 3 роки тому +1

      I would think both circuits are bonded in the panel

  • @DarrellHughes82
    @DarrellHughes82 2 роки тому

    Why can you not have the inverter and incoming ac both on at the same time? Isnt that the same as having a grid tie? Or does splitting the phase make an internal short because it internally crosses the phases?

  • @r.b.r9558
    @r.b.r9558 4 роки тому

    How I conect the 110 input home power socket

  • @mattyhudson2081
    @mattyhudson2081 5 років тому +2

    Anyone doing this should just call an electrician, why risk it.

  • @rongray4118
    @rongray4118 7 місяців тому

    Caution is good...commercials interrupting the high points of explanation absolutely ruin the concentration factor...

  • @greglatta6525
    @greglatta6525 5 років тому

    I bet you'll be receiving my inverter soon I sent it to you im greg. It had some issues on the watts reading.
    If that's how they are connected in split phase then how can you use the ats mode and charge batteries. I'm only using mine to power a 1500 watt space heater, I don't need to power my whole electrical panel.. But I do want a new 2018 model with ats so I can use grid power to charge my batteries at night so my heater will run...

  • @glenchoitz9497
    @glenchoitz9497 5 років тому

    Thanks for making a vid on this...by far one of the most confusing parts of the PJ 'manual' is the "cannot do L1+L2+N"...and even knowing how it works on utility power and should work with the inverter, it makes one scratch their head and second guess just in case PJ was meaning something else.

    • @lysol7204
      @lysol7204 5 років тому

      I had my 8000w LF connected like that, worked great for months, now it starts and turns off with a cotinuous beep. Dont know what went wrong. Power jack sells all the boards but mine is a single large board, could i buy all 7 individuall boards and replace my single large board? Looks like so!

    • @GenetrySolar
      @GenetrySolar  5 років тому

      Likely mosfet or control board failure.

    • @lysol7204
      @lysol7204 5 років тому

      @@GenetrySolar Thanks for the reply!
      Tried the inverter again and it works Ok for about 2 hours, then you se whatever is conected start to slow down and up about every two seconds, then it shuts down with a continuos beeb, fan stays on, (i allways keep it on). Im going to have to open it up again.

    • @GenetrySolar
      @GenetrySolar  5 років тому +1

      @@lysol7204 yes it sounds like a control board issue or heat issue.

  • @JjMn1000
    @JjMn1000 3 роки тому

    cool

  • @TimGray
    @TimGray 4 роки тому +2

    Note: do not go poking your fingers around inside a live panel like this video. It's careless and reckless.

    • @onekerri1
      @onekerri1 4 роки тому +1

      shut up.

    • @knurlgnar24
      @knurlgnar24 3 роки тому

      Tomorrow's Words of Wisdom from Tim Gray: "do not go poking your fingers in boiling water, or test the sharpness of a tablesaw blade with your thumb while it's running. It's careless and reckless." Thanks for tip!

  • @BCcustomFabrication
    @BCcustomFabrication 2 роки тому

    Alot of false information.

  • @dickson4650
    @dickson4650 Рік тому

    Do the new GS 12kw has one wire from Neutral to main panel and another wire from E of GS 12kw to main panel ? This video do not show E connected so the case of inverter is not grounded and dangerous .