  • Staad pro Tutorial of Truss Roof Warehouse Design with Hot Rolled Section. Warehouse required large span for material storage and truss are used when the span is large. Truss roof post can be build up I Section or any other hot rolled section. In this video tutorial I have shown how to do complete structural design of a truss roof warehouse using hot rolled section. This video has all the necessary steps from start to finish. Define material section, draw column, truss and bracing. Then how to define dead and live load and assign them on the structure. Then assign lateral load(Wind) and assign them on the structure as per the local code. After assigning all the load now define load combination as per local code. I have only three combinations, you may have more as per your local code. Then analysis the model and input the design parameter then complete analysis and design and optimize the size of column and truss member and bracing.
    Source File Download:www.mediafire.c...
    Subscribe My Channel for More Video Update:
    / structuralbd
    Like Us on facebook: / civilandstructuralengi...
    Join Us on facebook: / civilandstructural
    Follow Us on Pinterest: / moynnuddin
    Follow Us on Twitter: / structuralbd16
    Follow Us on Tumblr: / civilandstructuralengi...
    Follow Us on Google Plus: plus.google.co...
    For more information visit my website:
    structuralbd.com/
    ########################################################
    Watch More Video of Auto CAD2016 Full:
    • Auto CAD 2016 2D
    • Plan Elevation & Secti...
    Watch Full Video Of Etabs 2016 Concrete Structure:
    • Etabs 2016 Concrete St...
    Watch All Videos of Etabs9 Concrete Structure Analysis & Design:
    • Etabs9 Concrete Structure
    Watch Full Video of Staad Pro V8i Concrete Structure:
    • Staad Pro Concrete Str...
    Watch Full Video of Sketchup Pro 2017:
    • Google Sketchup 2017 B...
    Watch Full Video of Sketchup Pro 2017:
    • Google Sketchup 2017 B...
    Watch Full Video of Revit Structure 2017:
    • Revit Structure 2017
    Watch How to Design and Analysis Truss Using Staad Pro Software:
    • Truss Design in Staad Pro
    Learn Industrial Steel Shed Main and Gable Frame 2D Design in Staad Pro V8i:
    • Steel Shed Design 2D i...

КОМЕНТАРІ • 76

  • @faham5770
    @faham5770 11 місяців тому

    Thank you sir, for your dedication to share your knowledge. It's really helpful for upcoming designers.

  • @KennethUke
    @KennethUke 11 місяців тому

    Hi, please I need a video on how to run detailing both for steel and concrete. And also how to check if design parameters has passed or fail. Thanks for the video I really love it

  • @salauddinansari5444
    @salauddinansari5444 5 років тому +10

    Sir can u please make a video on wind load calculation...concept and that excel file..
    Please

  • @linusomattah3817
    @linusomattah3817 2 роки тому +2

    Hi , I must say you are doing a great job sir. Can you please give the link to the dwg file used for this tutorial? Thanks

  • @structuralchannel2507
    @structuralchannel2507 2 роки тому

    Hii sr my question to you is is the column hinged at bottom..?
    And also my question to you is if we have rigid or hinged joint at truss end then there will be large horizontal force on column which will induce large moment if bottom end not hinged

  • @Saikatsamanta1990
    @Saikatsamanta1990 5 років тому +3

    In the post analysis mode there are so many instabilities. Those instabilities should be removed before proceeding into member design.

  • @AnjishaDesign
    @AnjishaDesign 2 роки тому

    Good video with nice explanation.

  • @jigshot18
    @jigshot18 3 роки тому

    Is that wind load direction even correct? you should show your wind load calculation.

  • @mkn3817
    @mkn3817 2 роки тому

    Why purlins are not put? And also wind load should be producing uplift on truss

  • @subinaydeb2547
    @subinaydeb2547 2 роки тому

    I have tried for a structure. But it shows 1 error always " it seems there is no load cases" will you please help to short out the problem

  • @mahendraaandkaanchanpatil1489

    You are not creating purlin and neglected sheeting on top it seems 😮
    Can you please elaborate how you calculated loads which country code
    Your video key takeaway is Geometry creation 😢

  • @anujbhagwan8669
    @anujbhagwan8669 4 роки тому +1

    Nice explanation of interface& concepts.. requested to you, kindly upload the analysis and design for steel staircase.

  • @kenigramones
    @kenigramones 3 роки тому

    Can you explain why you didn’t apply the distributed dead load and live load on the purlins?

  • @praneshrathinam9684
    @praneshrathinam9684 6 років тому +1

    Sir, this is very good video explaining many things regarding design of steel structures.

  • @madhurjya4805
    @madhurjya4805 Рік тому

    Very very helpful 💜

  • @alfidasteel662
    @alfidasteel662 2 роки тому

    For wind Load Local Y must be positive sign. then Wind be out ward from structure. Please follow it. Also thanks the video crater Engineer.

  • @jubermejo4876
    @jubermejo4876 4 роки тому

    Thank you sir,Very Big help for me. Godbless

  • @nzanthungtngullie4528
    @nzanthungtngullie4528 4 роки тому +1

    Sir, which UBC code did you use for Wind load calculation?

  • @saivenkatv1124
    @saivenkatv1124 6 місяців тому

    Sir how to calculate dead load and Live load

  • @Sahil-su5hy
    @Sahil-su5hy 4 роки тому +1

    Dear Sir,
    Can you explain how local bending will be taken care when top cord is assigned as axial or truss member.

    • @syedarsalanali8506
      @syedarsalanali8506 3 роки тому

      Local bending of member will be due to ITS SELF WEIGHT ONLY i.e negligble .. See this ua-cam.com/video/7Gf-Qovq9_k/v-deo.html

  • @samiuddin9568
    @samiuddin9568 6 років тому +1

    very good video,sir can u add more lectures for steel structure with connections as well

    • @structuralbd
      @structuralbd  6 років тому +1

      I am going to add more video on multistoried steel structure. For connection may be delay

  • @nossamsrinivasulureddy146
    @nossamsrinivasulureddy146 5 років тому +1

    sir,Staad pro in define >Tapered1>use(like w500x450x10).sir use IS CODE book use.please make video sir.i hope .reply sir yes or no.

  • @deku7727
    @deku7727 4 роки тому +2

    You didn't specify the loading type in DL, ,LL, WRTOL, WLTR. I think that is the reason there is 32 warnings

  • @akashsanal
    @akashsanal 5 років тому

    Thank you sir. Appreciate your effort.☺️

  • @abraarkhan1024
    @abraarkhan1024 2 роки тому

    But you didn't conclude whether the members are pass or fail in output based on loadings. pls show the check code based on the standards

  • @singampriyokumarmeitei4193
    @singampriyokumarmeitei4193 5 років тому

    Why did you not rectify the warnings? There are 32 warnings.

  • @ravikumar-oo1em
    @ravikumar-oo1em 5 років тому

    Nice explanation. expect wind load calculation.please provide wind load cslcultion.

  • @abir021
    @abir021 5 років тому +1

    DEAR SIR , AS I KNOW THE TRUSS MEMBER CAN TAKE ONLY JOINT LOAD WHERE AS U HAVE APPLIED HERE MEMBER LOAD ...PLZ CLARIFY IT....THANKS.

    • @structuralbd
      @structuralbd  5 років тому +2

      We calculate joint load from distribute load when designing manually. But using software if we apply distributed load, software will calculate the joint load itself. No variation in result.

  • @pravinnikhare2712
    @pravinnikhare2712 2 роки тому

    Structure is fail in side sway. Please check the side sway i.e. horizontal deflection should not be more than H/200 or 100.

  • @DilipKumar-jg5ed
    @DilipKumar-jg5ed 2 роки тому

    Sir kaun sa app hai

  • @anwaransari798
    @anwaransari798 4 роки тому

    Sir thora slow maih video banaiyeh beginner ko samghaney maih dikat hoga

  • @kzero9714
    @kzero9714 6 років тому

    if the top chord and bottom chord of the truss frame is a continuous beam, would you need to assign Ly as the span between the ridge and the column ? because if you do, the allowable compressive strength on the chords would be so small that your model would be fail.
    and should the top and bottom chord be assigned as truss in the beginning anyway ?

    • @sarathpinninti9839
      @sarathpinninti9839 6 років тому +1

      Lateral buckling co-efficient Ly need not be assigned to top chord since the prulins and sheeting above it will take care of the buckling..but coming to bottom chord if no ceiling is present..i guess we need to provide longitudinal ties for every 5m atleast and provide ly as 5..even I guess the truss members only needs to be assigned to ties and not top and bottom chords..

  • @narasimhachary8003
    @narasimhachary8003 3 роки тому

    Thank you sir.

  • @jainmanoj7809
    @jainmanoj7809 4 роки тому

    Can AutoCAD file be imported to Stadd for truss modelling?

  • @ghazialobaidi2218
    @ghazialobaidi2218 4 роки тому +2

    I m steel designer and really worry about this video, specially when the beginners start with it and has no idea about stability of the structure. This structure is not stable in both directions regardless the results you got.

    • @shalinimundra3042
      @shalinimundra3042 4 роки тому

      @Ghazi Al Obaidi ..sir could uh tell me the reason. How this structure is not stable

    • @sankalpagrawal9868
      @sankalpagrawal9868 4 роки тому

      Yes. He did consider the panel length of bottom chord as effective length of truss bottom chord, which is going to be a huge disaster unless he provides tie runners at bottom chord

    • @raviprasadvoletiBR16L
      @raviprasadvoletiBR16L 7 місяців тому

      Pl. correct the procedure and guide the people, instead discouraging the young boy. No harm in sharing the knowledge.

  • @divybanugariya1039
    @divybanugariya1039 5 років тому

    I want your Excle Sheet .... May I get sir ??????

    • @structuralbd
      @structuralbd  5 років тому

      download link in the description

  • @structuralengineer5214
    @structuralengineer5214 4 роки тому +1

    Good

  • @saulosimpasa9259
    @saulosimpasa9259 4 роки тому

    helpful thanks

  • @sohidulhaque1146
    @sohidulhaque1146 3 роки тому

    Nice

  • @chowdarywork1117
    @chowdarywork1117 4 роки тому

    thank you sir

  • @vishalgadiwaddar7432
    @vishalgadiwaddar7432 4 роки тому

    sir i am getting error as truss/ cable/tension/compression member 331 in member release command how to resolve it sir?

  • @mdziamujahid
    @mdziamujahid 5 років тому

    can u share the wind load excel sheet

    • @structuralbd
      @structuralbd  5 років тому

      download link in the description

    • @sonammapari8914
      @sonammapari8914 4 роки тому

      @@structuralbd sir pls share excell shit of wind load calculation- sonammapari@gmail.com

  • @sidduhussain8005
    @sidduhussain8005 4 роки тому

    Please attach the excel file

  • @tushardabde9369
    @tushardabde9369 4 роки тому

    Please share excel sheet

  • @farhanqadir2394
    @farhanqadir2394 3 роки тому

    plz give us free software

  • @phanindraphanindra2767
    @phanindraphanindra2767 4 роки тому

    Too speed in explanation

  • @itspractical6830
    @itspractical6830 3 роки тому

    bhaiya hindi mai banaye please

  • @stephengreen2898
    @stephengreen2898 3 роки тому +1

    Why are most of these videos done by someoneWHO CAN’t speak English ?? The accent is so hard to understand for AMERICANS

  • @molayadhikary2553
    @molayadhikary2553 5 років тому +1

    Sir can u please make a video on wind load calculation...concept and that excel file..
    Please🙏

  • @lalitrajput6996
    @lalitrajput6996 6 років тому +1

    thank u sir