Design of Steel Roof Truss in ETABS

Поділитися
Вставка
  • Опубліковано 7 вер 2024

КОМЕНТАРІ • 77

  • @JudithTravis-q1j
    @JudithTravis-q1j 2 дні тому

    Young Kenneth Martin George Lewis Kenneth

  • @lossfreetrading996
    @lossfreetrading996 4 роки тому +2

    Good 👌

  • @MohitKumar-sr2zq
    @MohitKumar-sr2zq 4 роки тому

    From where you are?

  • @heidenfelderkustoms1502
    @heidenfelderkustoms1502 Місяць тому

    Is there anyone here that does design work in the Lehigh Florida area for a small project.

    • @structguru2200
      @structguru2200  Місяць тому

      Yes. please send me the details of the work on my email structguru@gmail.com

  • @heidenfelderkustoms1502
    @heidenfelderkustoms1502 Місяць тому

    Do you do design work for home shops? I want to add a loft and lean to on my existing structure.

  • @PramodKumar-bt2rw
    @PramodKumar-bt2rw 5 місяців тому

    Need the video for joint connection please.

  • @yaqubtasal
    @yaqubtasal 6 місяців тому

    thank a lot we learn ,ore thing in ETAB

  • @ultimatewarrior3829
    @ultimatewarrior3829 6 місяців тому

    Brother snow loading ki pe daalna hai rafter or purlin Or what? Aur snow load calculate kaise kare Plz

  • @samcapital9047
    @samcapital9047 7 місяців тому

    speak loud in your next videos

  • @Hanns_designs
    @Hanns_designs 11 місяців тому

    Thank you bro, learning alot from you

  • @modern_marvels
    @modern_marvels Рік тому

    Nicely explained.

  • @lokeshacharyab.g8006
    @lokeshacharyab.g8006 Рік тому

    Sir thanks for wonderful videos, sir kindly upload tubular section single truss roof with mangalore tile

  • @parag27865
    @parag27865 Рік тому

    Sir when you connection vedio will come waiting

  • @alihussnain8569
    @alihussnain8569 Рік тому

    I am facing extruding shell issue. On left side, the shell is being extruded on the lower side while on the right side, it is extruded on the upper side.

  • @flairsaavedra9079
    @flairsaavedra9079 Рік тому

    First time viewing. I hope I'll be more knowledgeable.

  • @maheshacharya7236
    @maheshacharya7236 2 роки тому

    Sir , In video the assign the relese to the truss member is skiiped ,

  • @omgomase84
    @omgomase84 2 роки тому

    What about earthquake and wind load combination.....

  • @ralftmanphetla8049
    @ralftmanphetla8049 3 роки тому

    hello, which design code do i need to use when i am in South Africa?

  • @maheshkolar3946
    @maheshkolar3946 3 роки тому

    Very useful tutorial.

  • @vithurshansivapalan8006
    @vithurshansivapalan8006 3 роки тому

    Thank you superb explanation

  • @AshwanikumarSainiARTER
    @AshwanikumarSainiARTER 3 роки тому

    nice tutorial. Yes connections are important and I was wondering how you connect everything together. e.g. purlins over trusses.

  • @inno5infra
    @inno5infra 3 роки тому

    I just designed a industrial warehouse where I took ISMB 600 (as columns) but all columns are fail.
    Can anybody give idea what could be reason behind this.?

  • @paradigmengineeringconsult3449
    @paradigmengineeringconsult3449 3 роки тому

    Dear sir,
    You are using the pressure coefficient value of Cp=-0.8 and Cp=-04 . Where do you get it from??
    I have found different value from IS 875 Part 3 .

    • @structguru2200
      @structguru2200  3 роки тому

      Its 0.8 and -0.5. This also depends on L/B ratio (L= length of the building plan and B= Width of the building plan)

    • @paradigmengineeringconsult3449
      @paradigmengineeringconsult3449 3 роки тому

      @@structguru2200 Which code you are using???
      IS or ACI??

    • @structguru2200
      @structguru2200  3 роки тому

      This is same in both ACI as well as IS code.

  • @astmcivil
    @astmcivil 3 роки тому

    if we select the auto-selection property for the truss top and bottom member and for the column it is a better way for steel design. by useing the auto-selection property program to collect economic section for all members

    • @inno5infra
      @inno5infra 3 роки тому

      I just designed a warehouse through auto beam n columns everything seems good except columns all columns have failed what could be reason behind this..?? 🤔

  • @astmcivil
    @astmcivil 3 роки тому

    good video

  • @snehaek687
    @snehaek687 3 роки тому

    Where is the question?

  • @edmundtumaca2334
    @edmundtumaca2334 3 роки тому

    How about a steel truss resting on concrete beam, how we do model the connection and what R value should be used for seismic.

  • @edmundtumaca2334
    @edmundtumaca2334 3 роки тому

    Thank you, so clear.

  • @roshankumar-ee2jh
    @roshankumar-ee2jh 3 роки тому

    Why is wind load not assigned to columns?

  • @mrmadame28
    @mrmadame28 3 роки тому

    Thank you!

  • @M0554
    @M0554 3 роки тому

    What is the safe p-m ratio?

    • @structguru2200
      @structguru2200  3 роки тому +1

      Should be less than 1.

    • @M0554
      @M0554 3 роки тому

      @@structguru2200 I'm not getting channels in rendered view?
      Also, the members seem to overlap rather than connected. Is that reliable?
      Next, I don't have steel connection design option in ETABS.

  • @kelvs526
    @kelvs526 3 роки тому +1

    How do you assign windload on 1 slope shed type roof? What is the direction of windward and leeward?

  • @sameerpatil3034
    @sameerpatil3034 3 роки тому

    Bro joint design kahape hain.

  • @wilkes0007
    @wilkes0007 3 роки тому

    It was a nice video and i am looking for a steel buildind video.

  • @anousitvlv
    @anousitvlv 3 роки тому

    Dear could you help me that why axial force of top and bottom chord of my model are so differently (around 72% of difference), but when i assign load on top chord directly, the axial force of top and bottom chord are quite closely.

  • @ajj7038
    @ajj7038 3 роки тому

    Please provide the same video in STAAD pro v8i software

  • @malithdesilva3607
    @malithdesilva3607 3 роки тому

    In my etabs steel model there is a failiur noted by "o" not os.. may i know what is that...
    facebook.com/100000574118663/posts/3913132398715859/

  • @arpitjaiswal5266
    @arpitjaiswal5266 3 роки тому

    What about the wind load from other direction.

  • @beenay18
    @beenay18 3 роки тому

    You also skipped assigning diaphragm to the roof. Can diaphragm be assigned to inclined shell element? Please make a video on that subject.

  • @beenay18
    @beenay18 3 роки тому +1

    I have a question. When you imported the steel sections, the section shape was indian but the default material was A992Fy50 which is American standard material. Fy of A992FY50 would be 355 Mpa is SI unit. I have seen people changing it to Fe250. Shouldn't we do that?

  • @beenay18
    @beenay18 3 роки тому

    I think you forgot to show how the moments in the truss joints are released. Is it ok to select whole roof and assign the pin joint constraint?

    • @rabinderladhani1294
      @rabinderladhani1294 3 роки тому +1

      I wanted to cover moment release topic in other video tutorial. Due to unavailability of time I am unable to post videos.

    • @muhammadsaqib5953
      @muhammadsaqib5953 2 роки тому

      @@rabinderladhani1294 do post it please

  • @beenay18
    @beenay18 3 роки тому

    I have a problem. When I draw a shell and assign null as section, and then apply shell load on it, it won't transfer the load to the beams and columns below it. How can I apply area loads avoiding the self weight of the shell element? Looking forward to get answer from you. Best regards.

  • @beenay18
    @beenay18 3 роки тому

    Thanks a lot. Great video. Good narration. Good voice. very clear and complete. Looking forward to watch other videos from you. Best wishes!

  • @shakiltadvi1049
    @shakiltadvi1049 3 роки тому +3

    Amazing tutorial.Sir can you please provide connection design tutorial for the same truss.

  • @anishpandey6573
    @anishpandey6573 4 роки тому +1

    Can you explain how you take windward coefficient as 0.8 and leeward coefficient as 0.5. Since as per code there is Cpe and Cpi (external and internal pressure coefficient)

  • @arbaz28
    @arbaz28 4 роки тому +1

    Great Video Waiting For More Informative Tutorials...
    Sir If possible Can you cover a tutorial on steel Building Design Which consit of BRBF ,EBF, SCBF as per AISC 360 & 341.
    Thanking You In Advance 😊

  • @dilipngangom4198
    @dilipngangom4198 4 роки тому +1

    Very lucid video. Your video has been interrupted. In order to release the moment to act as pin jointed, how will we release the moment?

    • @structguru2200
      @structguru2200  4 роки тому +1

      Thank you! I wanted to add this video (ua-cam.com/video/fm_vG-YvUkA/v-deo.html) about moment release. but it would have increased the video length. I will cover the moment release topic in detail in upcoming video on connection design. Stay tuned!

  • @azmat_waseem
    @azmat_waseem 4 роки тому +1

    Very Informative... Thanks....

  • @mathstube1802
    @mathstube1802 4 роки тому

    Which section is selected in Etabs for MS tube??

  • @phonenaingoo2857
    @phonenaingoo2857 4 роки тому

    I want to know how u do truss connection designs.

    • @structguru2200
      @structguru2200  4 роки тому +2

      Go to design tab and from there select steel connection design. I will explain in detail in my upcoming videos. Stay tuned!

    • @sanjayacharya3142
      @sanjayacharya3142 3 роки тому

      @@structguru2200 is there any videos?

    • @esliyohananmolinacourtois9878
      @esliyohananmolinacourtois9878 3 роки тому

      We need the connection video :(

  • @ajazsayyed8487
    @ajazsayyed8487 4 роки тому

    Best sir. I saw truss member releases In some of video plz comment on it.

    • @structguru2200
      @structguru2200  4 роки тому +2

      Thank you Ajaz! As truss is an axial member so we have to release the moments. To release the moment you can refer to my video ua-cam.com/video/fm_vG-YvUkA/v-deo.html. I will cover the moment release topic in detail in upcoming video in connection design.

    • @ajazsayyed8487
      @ajazsayyed8487 4 роки тому

      @@structguru2200 thank you so much sir.

  • @mathstube1802
    @mathstube1802 4 роки тому

    Upload using steel tube as materials on roof of building not as warehouse.

    • @structguru2200
      @structguru2200  4 роки тому

      ??

    • @mathstube1802
      @mathstube1802 4 роки тому

      @@structguru2200 Design Roof truss on top of G+3 using material as steel tube not as I beam or channel section.

    • @structguru2200
      @structguru2200  4 роки тому

      @@mathstube1802 is it a request or order ? :P

    • @mathstube1802
      @mathstube1802 4 роки тому

      @@structguru2200 if you take it as order its order and if you consider it as my request it's request...But what I am saying is like it's sincere request.

    • @structguru2200
      @structguru2200  4 роки тому

      @@mathstube1802 Hahahahah, you follow the steps and choose the tube section and try to design it by yourself. Let me know if you face any difficulty.