Це відео не доступне.
Перепрошуємо.

Universal condenser fan motor replacement HVAC

Поділитися
Вставка
  • Опубліковано 14 сер 2024
  • 🗣 In this video I will be replacing a siezed up Oem Condenser Fan Motor with a universal Condenser Fan Motor on a package unit.

КОМЕНТАРІ • 25

  • @supanovahpodcast3511
    @supanovahpodcast3511 2 роки тому +5

    did my 1st motor today great vid

    • @VictorofHVAC
      @VictorofHVAC  2 роки тому +1

      Awesome! Thanks for watching brother. Stay safe out in the field 👍

  • @DiegoTorres-om1ho
    @DiegoTorres-om1ho 2 роки тому +2

    I wouldve put a zip tie to bunch the wires up and feed it through. Then get the needle nose and grab the zip tie to pull the rest out. 👍 Nice vid.

    • @VictorofHVAC
      @VictorofHVAC  2 роки тому

      I love the feedback and I'm going to try that on the next Motor. Thanks for watching Diego 👍

  • @jamespatrick9449
    @jamespatrick9449 2 роки тому +1

    I will cut the old wires right at the old motor, and then tape new wires to them and pull through. If I forget I will use a longer panduet strap and use that to tape to and pull wires threw.

    • @VictorofHVAC
      @VictorofHVAC  2 роки тому

      Definitely a nice way to skin the cat. Thanks for sharing that brother 🙏 🙌 ❤

  • @joeanglin2849
    @joeanglin2849 2 роки тому +1

    Good job Victor 😊

    • @VictorofHVAC
      @VictorofHVAC  2 роки тому

      Thank you. I appreciate you leaving a comment Joe 👍 👌 🤝

  • @danielzertuche9893
    @danielzertuche9893 2 роки тому +2

    What's up my brother, great job 👍

    • @VictorofHVAC
      @VictorofHVAC  2 роки тому

      Appreciate that. Big things brewing brother 👍

  • @soloch69
    @soloch69 2 роки тому +2

    Great video 👍🏻 like always bro keep them coming and stay safe out there Don’t get on I-4 to much traffic lol 😂

    • @VictorofHVAC
      @VictorofHVAC  2 роки тому +1

      Thank you brother.... I just love the I-4 😂
      Same to you my friend 👍

  • @camrycowan6896
    @camrycowan6896 2 роки тому +2

    Thanks for this video. It's a great walkthrough. Where does the other end of the ground wire connect? I see where you put it on top of the motor, but I can't tell where the other end is.

    • @VictorofHVAC
      @VictorofHVAC  2 роки тому +2

      Your very welcome. Glad you enjoyed it. It goes to the inside of the motor housing, that's why I don't see it being necessary. (Just comes from the wire harness from the motor as a visual stand point)

    • @camrycowan6896
      @camrycowan6896 2 роки тому +1

      @@VictorofHVAC thanks for the reply! I read several discussions on Reddit and an HVAC discussion board, and I saw another video like yours where several people said the ground wire could be removed entirely if the mount was metal on metal. That was the case for my system, so I just took the whole thing off.

  • @jorgeespinoza238
    @jorgeespinoza238 2 роки тому +1

    Good tips man and let's get you to 1000 subscribers!!

    • @VictorofHVAC
      @VictorofHVAC  2 роки тому

      Thank you. Let's do it brother 💪 🙏 🙌

  • @alfonsohernandez2384
    @alfonsohernandez2384 2 роки тому +1

    What’s up bro …keep up the great videos

    • @VictorofHVAC
      @VictorofHVAC  2 роки тому

      Studying for my test is watsup ✍. I take my business and finance on the 7th in Gainesville. Thank you brother, will do

  • @DanielTorres-qd3fd
    @DanielTorres-qd3fd 2 роки тому +1

    I did a universal motor today on 99 model Lemnos unit, called for a 1/4 HP 1075 RPM motor, I installed a Century Universal 1/3-1/6 Motor, said it pulls 2.1 A but the one I installed is over heating and pulling 2.5 Amps and it has a new 7.5 Cap. Any ideas? I’m not a big fan of universal motors but that was my only option to get them going. Now it’s acting up again lol

    • @VictorofHVAC
      @VictorofHVAC  2 роки тому +1

      I've had motors come bad out the box. (universal and oem) assuming the condenser Coil is clean and the new 7.5 cap is actually putting out 7.5mfd , I would verify the wiring and if the the wiring is correct, I would just replace the universal with another and warrant it out.

  • @thesilentonevictor
    @thesilentonevictor 2 роки тому +1

    Yes I was saying why you didn't pass it in the grommet lol

    • @VictorofHVAC
      @VictorofHVAC  2 роки тому

      🤣 jokes on me this time 😂 thanks for watching Vic 👍

  • @ufartface
    @ufartface 2 роки тому +2

    those are nuts not screws