Position Continuous Pattern mitsubishi Servo MR-J3-10B QD75MH4 Positioning control | GT SOFTGOT2000

Поділитися
Вставка
  • Опубліковано 13 жов 2024
  • Continuous positioning control (operation pattern "01"), the next positioning No. is automatically executed.You Only need One Trigger to Move Servo Motor More than 1 Positioning, You Must set operation pattern "00" (Positioning END) in the last positioning data to complete the positioning.
    If the operation pattern is set to Continuous Positioning, the operation will continue until operation pattern END is found.
    If the operation pattern END cannot be found, the operation may be carried out until the positioning data No. 600.
    in this Video Will Explain Detail Continuous Positioning Control Mitsubishi Servo MR-J3-10B, QD75MH4 Positioning With GT SOFTGOT2000.
    #mitsubishi #servo #positioning #plc #hmi #tutorial #youtube