sewage Treatment plant onboard ship||

Поділитися
Вставка
  • Опубліковано 23 гру 2024

КОМЕНТАРІ • 107

  • @arsalnarker
    @arsalnarker 3 роки тому +10

    Informative.
    May ALLAH bless you.
    Love from Pakistan.....

  • @surajmohanty9278
    @surajmohanty9278 4 роки тому +10

    SKP se acha padhate Hain sir....Love u sir ,make more videos

  • @PraveenKumar-gv5uy
    @PraveenKumar-gv5uy 4 роки тому +14

    Really awesome bro.. you explained very well.. thanks for latest regulation on discharge condition

    • @PraveenKumar-gv5uy
      @PraveenKumar-gv5uy 4 роки тому

      And bro what us your rank on-board right.. are you 2nd

  • @tasawerashraf5190
    @tasawerashraf5190 2 роки тому +1

    best teacher ever sir great explanation

  • @aryanbacchuwar9918
    @aryanbacchuwar9918 7 місяців тому +1

    respected sir your videos are very helpful to all of us sir but just one problem is the pronunciation

  • @vaibhavmathur1993
    @vaibhavmathur1993 2 роки тому +2

    Happy Guru Purnima Sir

  • @manishrawat3534
    @manishrawat3534 8 місяців тому +2

    great explanation

  • @altamashbhore3990
    @altamashbhore3990 2 роки тому +1

    Mind-blowing explaining!!!!

  • @ALOKKUMAR-om4gp
    @ALOKKUMAR-om4gp 2 роки тому +1

    It's really Awesome video sir • keep it up•

  • @latafatali6787
    @latafatali6787 4 роки тому +1

    Really are doing excellent work ...keep it up , well done

    • @searainly
      @searainly  4 роки тому

      Thank you! & Welcome brother.

  • @imranhussain1842
    @imranhussain1842 2 роки тому +1

    Very nice exoanation sr

  • @aligoharmughal4952
    @aligoharmughal4952 3 роки тому +1

    Very Well explained Sir.

  • @haiderrizvi3509
    @haiderrizvi3509 3 роки тому +2

    sir you taught it very well......tysm...!!

  • @msgulss2121786
    @msgulss2121786 3 роки тому +1

    you are great sir, Stay Blessed Fore ever ...

  • @akshatdobhal9028
    @akshatdobhal9028 3 роки тому +2

    Very informative video sir👍🏻 learnt a lot thank you

  • @BillionBrothervlogs
    @BillionBrothervlogs 3 роки тому +1

    vry informative video please can u make a video on the mainatanance carried on sewage treatment plant and the safety measures to be followed while working on this plant.

  • @vaibhavmathur1993
    @vaibhavmathur1993 2 роки тому +1

    Thank you Sir for the wonderful explanation.

  • @siddharthkumar7011
    @siddharthkumar7011 3 роки тому +1

    great work sir..

  • @abhishektalajiya1987
    @abhishektalajiya1987 3 роки тому +1

    Very nicely explained 👍

  • @abelpena4449
    @abelpena4449 3 роки тому

    Dear Sir actually u explain very wel and very clear, but unfortunally I could not understood nothing because u are explained it in ur native language.
    So, I would like that u explaining also in english.

  • @chandrashekharkomara9891
    @chandrashekharkomara9891 3 роки тому

    Very well explained sir

  • @alfaysal4750
    @alfaysal4750 2 роки тому +1

    Nice sir

  • @thakurakash7
    @thakurakash7 3 роки тому +1

    thankew bhai ksm se samjh mai aa gya Thankew Bhai ...

  • @hiteshranglani5666
    @hiteshranglani5666 3 роки тому +1

    very informative.

  • @ritikbhayana1303
    @ritikbhayana1303 3 роки тому +1

    Amazing sir .Really helped a lot

  • @newkleus7106
    @newkleus7106 3 роки тому +1

    Great👏

  • @Sahil-sz3dp
    @Sahil-sz3dp 3 роки тому

    Is the blowers are runs continuously or cut out cut in is there and why?

  • @mohammadmoktaruzzaman4165
    @mohammadmoktaruzzaman4165 3 роки тому

    Nice explanation. Sir why foam coming out from vent.

  • @DIXITAGGARWAL93
    @DIXITAGGARWAL93 3 роки тому +3

    Many new ships uses sea water or fresh water for back flushing instead of grey water .

    • @searainly
      @searainly  3 роки тому +1

      Dear Dixit. Thank you for giving us such a good information. Please always take part in discussions. Thank you.

    • @soumikchatterjee9223
      @soumikchatterjee9223 Рік тому

      Can you please explain the process of back flushing using sea water?

  • @umasingh4187
    @umasingh4187 Рік тому

    Back flush bhi describe kar do sir

  • @Adarshvrm23
    @Adarshvrm23 Рік тому +1

    Incredible ❤

  • @esakkiraja548
    @esakkiraja548 2 роки тому +1

    You’re are great ❤sir I love you

  • @mithaleshkumar2486
    @mithaleshkumar2486 4 роки тому +1

    Blessing you God.......

  • @jayantgiri7920
    @jayantgiri7920 2 роки тому +1

    👌👌👌👌

  • @biswarupdas14
    @biswarupdas14 4 роки тому +2

    Sir if grey water is used to wash out the sewage stuck at the walls of the primary tank, then why is the grey water feeded directly to the chlorination chamber,as shown in your diagram?

    • @searainly
      @searainly  4 роки тому +7

      Grey water is used to wash or flush out the stuck sewage and particles from the system.
      Now come to your Question ...Please follow the path Carefully. Feed the grey water into the chlorination tank then it overflows and flows into the carbon filter wash or flush the stuck sewage particles from this chamber and then again grey water overflows into the sedimentation and primary chamber and does the same function. and in this way grey water flash out the stuck sewage and particles from the whole system and at the bottom part there is arrangement of valve. Open the valve hence all flush out water drain out.
      Analyse the flow path of grey water properly.
      Thank you!

    • @sachinchowdhary6804
      @sachinchowdhary6804 3 роки тому +1

      @@searainly Hello sir....Hope you are ok..
      I have a doubt on the same thing that on my ship 1st is bulky and 2nd one is tanker we used to flush STP with sea water in our daily routine and the grey water is thrown ovbd through different pipeline and the ovbd vv is Both port and stbd side??
      Have you sailed on the ship on which grey water is used for flushing or you have read it from somewhere???please make me understand because we have seen sea water flushing not with grey water??

  • @karunmonnappa467
    @karunmonnappa467 2 роки тому +1

    Sir if activated sludge is removed from settling tank with venturi effect isn't there a greater possibility that the nozzle could be blocked by sludge..?

  • @homegrown1444
    @homegrown1444 3 роки тому

    And anthour question what steps to be adopted when we are running out of chemical during sailing

  • @Sandeep-je6wu
    @Sandeep-je6wu 2 роки тому +1

    Thank you so much sir.

  • @mithaleshkumar2486
    @mithaleshkumar2486 4 роки тому +2

    So thank you sir

  • @sugarspicesatya
    @sugarspicesatya 4 роки тому +1

    Nicely Explained. Can you please share the block diagram as well. TIA

    • @searainly
      @searainly  4 роки тому

      Sure! soon will provide link for the same.Thankyou.

  • @sohamadhya3969
    @sohamadhya3969 2 роки тому

    what should be the pressure of this grey water and how the grey water will pass from sterilization tank to the other tanks for flushing

  • @AMANKUMAR-iz6jf
    @AMANKUMAR-iz6jf 4 роки тому +1

    Sir 2 questions-
    1)If blower fails,action ??
    2)If discharge color is grey,reason and action?.
    Sir short mai hi bata dijiyega.

    • @searainly
      @searainly  4 роки тому +1

      There is standby blower if one blower fails second blower comes..
      The requirement of blower here to supply air to the chamber to allow the aerobic reaction if air is not supplied then anaerobic reaction takes place inside the chamber and hydrogen sulphide' gases are released that cause marine pollution.

    • @searainly
      @searainly  4 роки тому +2

      Grey water is generally cooking and cleaning waste

    • @AMANKUMAR-iz6jf
      @AMANKUMAR-iz6jf 4 роки тому +1

      Thank u so much sir.

  • @akashverma9272
    @akashverma9272 2 роки тому

    Dangers while opening biological stp for repairs? How to minimise the risk

  • @ankitanandvlogs
    @ankitanandvlogs 2 роки тому

    Hello sir, thanks for this video. Sir my ship was 2000 built gas tanker. Here these 3 chamber has common line which is connected to overboard pump. Now on our ship we had also sea water line connection to this common line to backflush. However, at some time, we used to open STP, and manually clean, later fill again with sea water, open all the valves,, start blower. when it reaches certain level, air bubbles with water can be seen in inspection pipe during operation.

  • @animalsdocumentary6600
    @animalsdocumentary6600 2 роки тому +1

    Thank you sir

  • @homegrown1444
    @homegrown1444 3 роки тому

    Sir one important question please reply asp que - what is procedure adpoted when STP is out of order on borad ship?

  • @shyambiradar4360
    @shyambiradar4360 3 роки тому +1

    Sir explain about ejector in this system

  • @SurajCMathew
    @SurajCMathew 2 роки тому +1

    ❤️❤️❤️

  • @MdHasan-iv5im
    @MdHasan-iv5im 3 роки тому

    What should be checked on sewage treatment plan during watch?

  • @surajmohanty9278
    @surajmohanty9278 4 роки тому +1

    Sir if possible please make on IC also

    • @searainly
      @searainly  4 роки тому +1

      After completing Marine Aux M/c will make videos on main engine topics also.Dont worry.! Thankyou.

  • @souravnair8893
    @souravnair8893 3 роки тому +1

    Sir, 25mg/ltr of what?

    • @searainly
      @searainly  3 роки тому

      As per MEPC the concentration of sewage which is going to be overboard must be less than 25mg/litre .

    • @aligoharmughal4952
      @aligoharmughal4952 3 роки тому

      not more than 25mg /ltr of Suspended Solids should be present In the treated Affluent that is being discharged overboard as per MEPC.

  • @shubhguleria9226
    @shubhguleria9226 3 роки тому

    Explain about airlift of activated sludge. You said its sucks air out of ventury, i doubt it is opposite. Can you clearly explain?

    • @searainly
      @searainly  3 роки тому +1

      I already said activated sludge get sucked (with the help of venturing effect) and it return through returning sludge line and again mixes with incoming sludge.

  • @kislaymishra6846
    @kislaymishra6846 4 роки тому +1

    Sir ji engine room piping layout pe ek video, please sir 🙏

    • @searainly
      @searainly  4 роки тому +1

      Sure brother! MAM k part m hi cover krunga Just give me sometime. Thank you!

  • @karanjans
    @karanjans 3 роки тому

    Sir which device is used for measuring BOD 25mg/L.? Kaisa pata chalega
    Please also explain Aerobic and An aerobic chemical reactions also

  • @deepaksaxena222
    @deepaksaxena222 3 роки тому

    About stp maintenance?

  • @yaaralbele7040
    @yaaralbele7040 4 роки тому +1

    What about omnipure stp

    • @searainly
      @searainly  4 роки тому +1

      OMNIPURE(Name) is the manufacturer of high quality, cost effective waste water system..Most of the Marine STP is Omnipure marine sewage system that oxidizes sewage in an electrochemical cell as well as generates sodium hypochlorite for the disinfection of the sewage streams.

    • @yaaralbele7040
      @yaaralbele7040 4 роки тому +1

      @@searainly pkz make one video on that

    • @searainly
      @searainly  4 роки тому

      Thank you for your response and suggestion.. Will try to upload video on this topic soon.

  • @AMANKUMAR-iz6jf
    @AMANKUMAR-iz6jf 4 роки тому

    Sir in this video how biological oxygen demand is confirmed as 25mg/l.ye kaise calculate karenge?

    • @searainly
      @searainly  4 роки тому +3

      The effectiveness of Sewage analysed by taking 1 litre of sewage sample and incubating it for 5 consecutive days at the temperature of 20 degree Celsius with well oxygenated water.
      Now The amount of oxygen used up by the sewage in mg/l or PPM KS termed here BOD and In this case that BOD comes is 25mg/L(u have to continue with this process BOD reaches up-to 25mg/l & This new resolution value is set by MEPC.

    • @AMANKUMAR-iz6jf
      @AMANKUMAR-iz6jf 4 роки тому +1

      Bahut bahut dhanyabad sir.

  • @Sachinsharma-hb3py
    @Sachinsharma-hb3py 3 роки тому +1

    thank you so much sir

  • @rishukapoor2835
    @rishukapoor2835 2 роки тому

    Sir, how to control/reduce BOD and COD of sewage treatment plant. What actions can we take onboard ship?

  • @shyambiradar4360
    @shyambiradar4360 3 роки тому

    Pr. Of blower in aeration chamber is 0.3 to 0.5 bar.
    Atmospheric pr. Is approx 1 bar.
    How does the blower making the pr. Of .3 to .5!!!!

  • @arshkapadi6689
    @arshkapadi6689 4 роки тому +1

    Thank you, Sir

  • @RajeshSingh-iz6uj
    @RajeshSingh-iz6uj 3 роки тому

    How can I reach to you plz ?

  • @SubhodeepPramanik
    @SubhodeepPramanik 3 роки тому

    thanks sir

  • @atikrahman6184
    @atikrahman6184 Рік тому

  • @jahanzabbaloch234
    @jahanzabbaloch234 3 роки тому

    Awlllaaa

  • @getachanie9136
    @getachanie9136 3 роки тому

    please explain it in English