How to set up a ferroli boiler

Поділитися
Вставка
  • Опубліковано 27 лис 2024
  • This is for the iboiler/He26c and euroterm only not the Modena
    PERAMETER 2 :is ramp rate ie speed to get to Temperature .Up to 6 rads at 2 and 7 or over at 3
    PERAMTER 6:is the output ie how hard you want boiler to work. Each rad is worth approximately 10 .But obviously adjust it accordingly adding another 5% pressing plus or subtracting 5% pressing minus either way if noisy and heating up quickly or not enough and taking too long
    PERAMETER 12 : hot water output = 85
    Following boilers i25 29 ,he 26c , fer 25he ,euroterm
    Domicondens f28 is slightly different
    Perameter 2 is ramp rate still
    Perameter 9 is the output
    Perameter 13 is hot water output at 85
    KEEP TEMPERATURE ABOUT 60 TO 70
    Generally if set at 60 degrees it won't turn off until another 10 degrees after .if you want it at 70 set it at 60
    WITH ECO ON

КОМЕНТАРІ • 62

  • @jenniferedmunds572
    @jenniferedmunds572 4 роки тому +2

    I have come to you on several occasions and you have always given me the answer, thanks

  • @neddipa3904
    @neddipa3904 Рік тому

    Hi there, do you have the parameters list for a HE Plus 31C. I know they are factory set but it would be good to check the parameters . Many thanks

  • @mp2172
    @mp2172 4 роки тому +1

    Is there a reset to default on this? I think I may have adjusted other parameters by not knowing what I'm doing. If not, I think P01 would be the most likely to have been adjusted, could you provide the setting for that please?

    • @gigeluran3195
      @gigeluran3195 10 місяців тому

      Did you figure out a way? I ve made the same mistake and now mine will go to 3 bar when turning on hot water and the heat will be on nonstop

  • @DaleMarriott1337
    @DaleMarriott1337 8 місяців тому

    Hi do you know what causes A41 and how to fix it. I have it servived and they go in the boiler and all time I have problems when they done the service. I brought the flow sensor which seems to be a magnetic switch. however looked in the boiler the connection looks good. its a optimax he31c is parameters same for that boiler?

    • @theferroliman2067
      @theferroliman2067  8 місяців тому

      F41 is poor circulation..first check the sensor on the left hand side of heatexchanger it's black and white it could be loose and not sitting on the pipe correctly.

    • @DaleMarriott1337
      @DaleMarriott1337 8 місяців тому

      @@theferroliman2067 do you have a part code and can i get to this by just removing the white cover? I checked the bottom sensor on the flow switch and a blue wire came out of that i have taped it back in to the connector but it still trips so im thinking its this sensor your talking about. Oh by the way its A41 not F41

  • @السباكةالحرفين
    @السباكةالحرفين 2 роки тому

    شكرا جزيلا لك أستاذ
    من فضلك كيف يتم معالجة المشكل f07

  • @levelont5560
    @levelont5560 6 років тому +1

    Is there a document where all menus and options are described? Haven't been able to find one at their home page!

    • @theferroliman2067
      @theferroliman2067  6 років тому +1

      You won't find one ...only the ferroli engineers have them .As homeowners have a tendency to fiddle around .Hence why I've shown the key parameters thats really any use anyone to actually change ...

  • @mohammedelibrahymy2524
    @mohammedelibrahymy2524 2 роки тому

    اليجزيك بالخير شكرا نوريد مزيد الشرح

  • @colettereilly5589
    @colettereilly5589 Рік тому

    6:23 the fuse on the wall next to the boiler stopped working. We replaced it with a new fuse but our boiler won’t light up. It’s a farolli boiler.

  • @nareshpalsingh1236
    @nareshpalsingh1236 3 роки тому

    Heating is working fine

  • @ricknotnorris
    @ricknotnorris 4 роки тому

    Hi is it the same set up for ferroli optimax he plus 38c .please

  • @robertt6430
    @robertt6430 5 років тому

    When I select parameter 6 I can only choose between one and three can you help.

  • @ghebby46gheb7
    @ghebby46gheb7 3 роки тому

    hi. I need to put the boiler in stand-by mode (as requested in the manual to change between natural gas to LPG) but I don't know how to do that. can you help me? thanks

    • @theferroliman2067
      @theferroliman2067  3 роки тому

      You'll need to tell me what boiler u have as there's different ways of setting up the LPG in the parameters. Plus some need injectors replacing aswell .

    • @ryanhall4083
      @ryanhall4083 3 роки тому

      Same question mine is a sky eco 11l

    • @theferroliman2067
      @theferroliman2067  3 роки тому +1

      @@ryanhall4083 if you bought you water heater as a natural gas type then u need someone gas safe registered to convert it as the injectors aren't LPG.And set up the circuit board for LPG aswell .

    • @ryanhall4083
      @ryanhall4083 3 роки тому

      @@theferroliman2067 Thank you, I guess that will cost a fortune! Thanks for the help

    • @ryanhall4083
      @ryanhall4083 3 роки тому

      @@theferroliman2067 I just double checked, this was the description Ferroli 11L LPG Room Sealed Water Heater & Flue Replace Morco F11

  • @jjohnson_horse_rider_soulitons
    @jjohnson_horse_rider_soulitons 5 років тому

    Hi how do I raise the temperature on my boiler too more than 50??

  • @cineymatic
    @cineymatic 4 роки тому

    How to resolve A01 error. Other gas appliances are working fine.

  • @theferroliman2067
    @theferroliman2067  6 років тому +1

    More information is in the description if you press the arrow/triangle button rhs

    • @claudiasantos8905
      @claudiasantos8905 6 років тому

      Dave Allum boilers
      Hi
      I have a ferroli f24
      It's showing A01 fault
      Do you know what to do?

  • @Itisfinished.
    @Itisfinished. 4 роки тому

    Great help bro,,thank you

  • @ivanrely1158
    @ivanrely1158 Рік тому

    👍(A03 - Feroli BLUEHELIX PRO 25C)

  • @zakariazizou1639
    @zakariazizou1639 4 роки тому

    Please help me Unother problème a 15 chaudières ferroli diva

  • @nareshpalsingh1236
    @nareshpalsingh1236 3 роки тому

    Hi I have ferolli f24 Combi , we have no hot water coming from the boiler please help

    • @theferroliman2067
      @theferroliman2067  3 роки тому

      You may need an engineer to repair this ...it could be anything . Sensors ,fan parts , stuck flowmeter if u have heating then u need to see if the tap light illuminates when the tap is turned on that'll answer a few questions if it does or doesn't

    • @nareshpalsingh1236
      @nareshpalsingh1236 3 роки тому

      @@theferroliman2067 thanks

  • @bellifanazim5857
    @bellifanazim5857 3 роки тому

    Please how to resolve F05 problem thank's

    • @theferroliman2067
      @theferroliman2067  3 роки тому

      This fault needs an engineer visit ...it could be expensive guessing as it could be at least 4 different parts or adjustments

    • @bellifanazim5857
      @bellifanazim5857 3 роки тому

      @@theferroliman2067 thank you for your help please which part can be changed

    • @theferroliman2067
      @theferroliman2067  3 роки тому

      @@bellifanazim5857 it could be a circuit board, fan ,air pressure switch (if it has one) , a fan Venturi adjustment .

  • @aliraheem9872
    @aliraheem9872 6 років тому

    my boiler display - - what to do ?

  • @mikeb-hn2xu
    @mikeb-hn2xu 6 років тому

    when i select parameter 6 on mynodena 27c he i do not get a percentage of up to 100% i can only select between 1 and 7

    • @theferroliman2067
      @theferroliman2067  6 років тому

      This one doesn't cover the MODENA he ... You shouldn't need to adjust the output on a MODENA . Bit if you do, it's parameter 13 .

    • @robertt6430
      @robertt6430 5 років тому

      When I select parameter 6 I can only choose between one and three.
      This is a demicondes f28 can you help .
      Cheers.

    • @tablireparationchaudiere9551
      @tablireparationchaudiere9551 5 років тому

      F7 érror f7 érror

    • @tablireparationchaudiere9551
      @tablireparationchaudiere9551 5 років тому

      Bravo do you give me paramaitre ferrolli 😰😰😰😰

  • @dyll3r
    @dyll3r 5 років тому

    hi , i want all default parametrii on nr 1..to16 please

  • @mahmoudbenahmed6404
    @mahmoudbenahmed6404 5 років тому

    Nice

  • @frankalexander6629
    @frankalexander6629 2 роки тому

    Doesn’t work on the HE 31c! P6 & P12 you can’t set up the % for number of radiators and P12 you can’t adjust the temperature of the hot water. I have HW but no CH and thought I would try and tell it how many radiators (2) it works to. As I found out, this doesn’t work!

    • @theferroliman2067
      @theferroliman2067  2 роки тому

      This video isn't for that boiler...it's for other models domicondens, he 26c , íboiler, eurotherm
      If you listen from the start it tells you what boiler model it's for

    • @aleksandarprashkov
      @aleksandarprashkov Рік тому

      @@theferroliman2067 can you share which are the parameters for range rating the power on the HE PLUS 31c?

    • @abdoudouarna2563
      @abdoudouarna2563 11 місяців тому

      Have error f05.

  • @robertt6430
    @robertt6430 5 років тому

    Domicondens f28

  • @zakariazizou1639
    @zakariazizou1639 4 роки тому

    Stp problème f 05 ferroli diva

    • @theferroliman2067
      @theferroliman2067  4 роки тому +1

      This fault is normally a circuit board fault

    • @zakariazizou1639
      @zakariazizou1639 4 роки тому

      @@theferroliman2067 It turns on and off, but most of the time is off

    • @zakariazizou1639
      @zakariazizou1639 4 роки тому

      When placing the cover, it stops forever

    • @theferroliman2067
      @theferroliman2067  4 роки тому

      @@zakariazizou1639 F05 will depend on which boiler model u have ... Pcb , fan , air pressure switch, clean fan or adjust fan Venturi ..are the possible problems

    • @zakariazizou1639
      @zakariazizou1639 4 роки тому

      @@theferroliman2067 thanks very match gys ❤❤

  • @علآءالدينبسمةأمل
    @علآءالدينبسمةأمل 2 роки тому

    Paramètres ferroli diva c32