Checklist For Shuttering Of Column | Column Shuttering Checking Procedure
Вставка
- Опубліковано 12 сер 2019
- Checklist For Shuttering Of Column | Column Shuttering Checking Procedure
In this video, I have covered the Important points need to check for the Shuttering of Column at the construction site practically.
✔Official Website in English
www.learningtechnologyofficia...
✔Official Website in Hindi
www.civilofficial.com
⓿My Playlist Link
✔HOW TO STUDY DRAWING
• How To Study Drawing
✔CIVIL INTERVIEW
• Interview
✔CHECKLIST OF CIVIL WORKS
• Checklist of Civil Works
✔BBS (BAR BENDING SCHEDULE)
• BBS (Bar Bending Sched...
✔QUANTITY ESTIMATE
• Quantity Estimate
✔CONCRETE VOLUME CALCULATION
• Concrete Volume
✔IS CODE LECTURE
• IS CODE LECTURE
✔DREAM HOUSE CONSTRUCTION SERIES
• DREAM HOUSE CONSTRUCTI...
✔HOUSE CONSTRUCTION
• House Construction
✔HOUSE PLAN
• House Plan
✔CIVIL EXPERIMENTS
• Experiment
✔SURVEYING
• Surveying
✔CIVIL ENGINEERING TALK
• Civil Engineering Talk
****************************************************************
⓿Download my App FromPlaystore
✔ Civil IS Code App
play.google.com/store/apps/de...
✔ L&T Official App
play.google.com/store/apps/de...
✔ App For Interview Papers
play.google.com/store/apps/de...
****************************************************************
⓿About Channel
L & T - Learning Technology: This channel contains Technical Lectures on "Civil Engineering" from Personal Field Experience by Civil Engineer Mukesh Sah.
✔Email Id for Business Enquiry - civilengineeringofficial@gmail.com
#CivilEngineerMukeshSah #ChecklistForColumnShuttering #ForworkChecking #CivilEngineeringVideos #LearningTechnology #L&T-LearningTechnology
I want to add some points:
1. Check the right angle at the corners of column shuttering.
2. Providing proper gauge with help of steel rods to the column shuttering.
3. Check if proper cover is provided to column reinforecemnt or no before pouring concrete.
Thanks Sir.
Orientation of column if it is rectangular in shape, Sir.
Thanks for your loving videos.
I think you have covered all important points in this video. Thanks. I request to you please make a video on the points of after pouring the columns. Will wait. Thanks again.
Thank you very much for this video.
Thank you sir ji God bless you
Very very nice video 👌
Super bro
Good job
Nyc information
Nice Video
Bahut hi shaandaar video. Sir how we fill gaps with foam. Hv u some practical video on it and on MEP. Thanks
In column starter we should fix foam applying grees all sides
Sir, Mera ak request hai.. Mivan formwork kya bare mai.Mivan formwork kya kam karne time kya kya dekhna jaruri aur kaise kam ko kara jatah hai.full execution of work.
Discus about column bar cutting and binding...
👍👍
🙌🙌
3 pile cap bbs ki vedio kab denga sir..upne to boli thi ki bohut jald dalenga but bohut din ho gaya but up vul gaya hoga..plz sir 3 pile cap bbs ki ek vedio upload kiziya..love you sir..God bless you..
Sir please concrete road construction and estimation per video banao please
Clining &house keping
Dear Mr. L&T, please provide information of supporting distance
Kitne height par boiler all layer ka supporting karna hota hai
Minimum distance between boiler should be 600mm c/c.
From down you should provide wailer in 300 mm and after that 500 mm minimum depending upon column size and quality of shuttering materials
Last time upar sariya ki over lepping nad top sariya ki kavring Shahi hona chahiye ya nahi
Sir,
Jo vedio bheja h ushme mujhe ye samjh me nahi aaraha h ki Jo horizontal support h o load ke hisab se minimum spacing kitni honi chahiye
Sir please make video mi van shuttering
I like you
Superb sir ji
Diagonal kaise check kare?
Video bana dunga uspe. Must Share with your Juniors and friends.
@@LearningCivilTechnology yes
Mivan shuttering please inform
Clear cover mast be check
Clear cover during reinforcement
Sir ager muje 15 ' ka arc ground pe draw karna h uska kya process hoga plzz sir reply me
Sir shuttering site pe kitni chahiye es par video baniye
Sir cover blocks bhul gaye
I think that Will be covered in reinforcement part.
Marking kayse kare
Sir . Ye piont rh gya tha, 1. plumbing after concrete pouring in Columns
Mechanical Electrical plumbing column impossible hai because of weekness column strength
can you share all these in PDF ?
Batten konsi wood ki acchi rehti h..
Teak wood
Diegnal kaise nikale
Please provide shuttering design for retaining wall, column, beam, slab for conventional method
Upar li laen chaek karna aahe
सर कितने ऊपर से कॉंक्रीट डालना है। ताकि कॉलम के नीचे हनीकॉम ना हो।
Also mention. Tie bar, bbs, pouring sequence, co-ordinates
BBS and Steel Reinf. Related points in column should be check before shuttering.
सर थोड़ी जानकारी लेनी थी आपसे की SUBSTATION में सिविल के वेकैंसी निकलती है उसमें एक्सपीरियंस उसी का मांगते है। SUBSTATION में सिविल वालो का क्या काम होता है। आज कल बहुत ज्यादा जॉब्स निकल रही है इसमें। समझ नही आ रहा है होता क्या है मेरा एक्सपीरियंस बिल्डिंग लाइन में है मुझको मना कर दिया उन्होंने।
Substation install krne ke liye ek building ki zarurat hoti hai jisme Trasfarmer foundation aur bhi bahut type ke pipe supports sleepers hote hain jo ke civil construction work hota hai
Spacing of batten and tie rod tient or shikanja
Providing of master ring
Sir 5 no point
Hum support ka interval kitna rakhe?
Matlab 2400 ka board hoga to Kya hum har 1000 mm pe ek support laga sakte hai, yeah phir Kam interval me lagana padega?
Please Sir.