Desi Jugad For EV Cars *Without Earthing* Ab charging es jugad k sath

Поділитися
Вставка
  • Опубліковано 15 лис 2022
  • Thanks For Watching
    If you want to share your ownership Experience,
    E-Mail - anubhavchauhan2322@gmail.com
    #Anubhavchauhan
    Social Media Links
    Facebook
    bit.ly/2EAEmk3
    bit.ly/2FTOUv0
    Instagram- bit.ly/2QtJF7s
    Twitter- bit.ly/3loSaPi
  • Авто та транспорт

КОМЕНТАРІ • 70

  • @asurakengan7173
    @asurakengan7173 Рік тому +25

    This will kill any person inside car or touching the car if there's even slight leak.

    • @svXPs
      @svXPs Рік тому +4

      I won't recommend this. And this video shows an image where Phase is shorted to Earth which is deadly.
      But if you short Earth and Neutral, this will kill someone only in two cases.
      1) As long as RCCB is not provided in the whole circuit.
      2) if he is getting shock from phase to vehicle body.

  • @ahsanzahir100
    @ahsanzahir100 Рік тому +7

    Instead of loose wires, 3, use cable that has 3 wires.. and is plastic coated..

  • @user-bq3ql8ol7d
    @user-bq3ql8ol7d Рік тому +11

    Please don’t follow this method. If there is any leakage in the inbuilt car charger( I know a case where there was leakage in car during rainy season and charger was giving alarm) this method will kill the person who touch the car.

    • @svXPs
      @svXPs Рік тому +1

      I won't recommend this. And this video shows an image where Phase is shorted to Earth which is deadly.
      But if you short Earth and Neutral, this will kill someone only in two cases.
      1) As long as RCCB is not provided in the whole circuit.
      2) if he is getting shock from phase to vehicle body.

  • @ch7ramesh
    @ch7ramesh Рік тому +2

    Bro..Can we use 15 amp power extension board like u used .
    .From normal power socket board for
    Ev charging

  • @surryyyaaa
    @surryyyaaa Рік тому

    5 amp plug me kam krta charger?

  • @SelfLove-y9l
    @SelfLove-y9l 5 днів тому

    आपने घर के अंदर कहां प्लग किया वो दिखाया ही नहीं...
    डायरेक्ट मीटर connection चाहिए क्या ईसको की घर के किसी 15 amp के प्लग मे लगा सकते हैं ?

  • @sunilchaudhary83
    @sunilchaudhary83 10 місяців тому +4

    Highly risky if you connect live wire with earthing.. It wil causes shirt circuit..

  • @nikhilphore6818
    @nikhilphore6818 11 місяців тому

    Bht badhiya mere Bhai dhanya ho tera engineering Karan ka bht madad krdi jai baba ki🎉 easy and cheap way which company not give

  • @atulmits
    @atulmits 7 місяців тому +2

    Bhai bhool ke bhi ye nhi karna , Neutral aur earthing me fark hota hai... Neutral me 12 Volte aate hai normally kabhi bhi.. aur earth me 0 volte hota hai... apni car me aag lagane ho tabhi ye harkate kariyo..

  • @GEETASINGH-zj3nw
    @GEETASINGH-zj3nw 4 місяці тому

    Bro arthing dene pr bhi nhi ho rha hai

  • @sharibshamim7037
    @sharibshamim7037 4 місяці тому

    If you connect neutral one in line whole car will give bijli ka jhatka so test with tester to place phase in phase and neutral in neutral

  • @pawarmurali5277
    @pawarmurali5277 11 місяців тому

    Thanks

  • @vinodruhil6634
    @vinodruhil6634 Рік тому

    Good work Bro.👍

  • @babusingh2440
    @babusingh2440 Рік тому +4

    I’m electrical engineer 😅
    Or ye galt tarika hai earthing foult condition ke liye hoti jo aag lagane se bachaa sakti hai ghadi ko
    Nutral me jodne se agar foult huaa to sara current nutral me nhi jata is liye ghadi me us condition me aag lag sakti hai
    To ye sirf safety feature hai

  • @ravimajjari9308
    @ravimajjari9308 4 місяці тому

    how much consume the power and per kw how much current bill for ev car in home

  • @udaypratap33
    @udaypratap33 Рік тому

    Sirf anchor ka board hi use kro

  • @sabkaswagat
    @sabkaswagat 2 місяці тому

    Isse bhadiya toh charger ke plug ke neutral or earth ko apas mein short Kara do ek wire se and all set 👍

  • @ariseagain3423
    @ariseagain3423 6 місяців тому

    Do fuse lagana tha idhar uthar shift krne ko problem solve

  • @bhanu98ful
    @bhanu98ful Рік тому +1

    I guess this suggestion may back fire , and this will damage battery heavily in the long run. Not recommended

  • @hlacieux
    @hlacieux 5 місяців тому

    Neutral ko earth se merge or shot kr do ho jaega

  • @Believers_s
    @Believers_s Місяць тому

    Humare gaon mai direct pole se charge kr lete hai 😂

  • @mudavathkumar9620
    @mudavathkumar9620 4 місяці тому

    Super ❤❤❤

  • @justcurious40
    @justcurious40 Рік тому +1

    Incorrect and very Risky method- using earth is much more better

  • @netajipalkar7521
    @netajipalkar7521 5 місяців тому

    भाई साहब earthing होती है एक्सट्रा इलेक्ट्रिसिटी को ग्राउंड करने के लिए. ऐसे मत करो जमीन मे गाड दो earthing

  • @globetrekker777
    @globetrekker777 Рік тому +2

    WARNING: DON'T TRY THIS AT HOME. YOU CAN TRY THIS OUTSIDE THE HOME 😂😂😂😂

  • @skjahir3502
    @skjahir3502 9 місяців тому +2

    Gadi to na jali, lekin ghar ka fuze ud gia mera 😂

    • @skjahir3502
      @skjahir3502 6 місяців тому

      @@SiddharthaKamble-rg8ji 😑😆

  • @helloamitbansal
    @helloamitbansal 4 місяці тому

    Bhai mechanical Engineering kaha se ki hai? ye tareeka sahi nahi hai...

    • @anubhav780
      @anubhav780  4 місяці тому

      Bhai m to esi tarike sy 2 saal sy gadi charge kr rha hu

  • @mr.satnam777
    @mr.satnam777 7 місяців тому

    Earthing ko hi phase bana diya 😅😅😅

  • @prashantdvful
    @prashantdvful 6 місяців тому

    Creating Killing machine if there is any shortckt then it will supply current to the body of car aswell can damage car ckt
    Earthing is used to supply short ckt large current to earth to protect appliances and prevent shock

  • @yogendergera4688
    @yogendergera4688 4 місяці тому

    Electrical engineer hi kaand karte hai baki normal log protocol follow karte hai

  • @vedantpotdar5022
    @vedantpotdar5022 Рік тому +1

    Excellent bhai Love from Mumbai 🔥🔥🔥🔥🔥🔥🔥🔥 lekin bhai earthing hona bohot jaruri Jain

    • @anubhav780
      @anubhav780  Рік тому +1

      Ha bhai jaruri hai
      But khi bhar jate h to kafi jgeh earthing ni hoti
      Charging station ko chod k

  • @puneetsharma86
    @puneetsharma86 7 місяців тому

    Brother this is working ultimate.
    Thanks a lot

    • @AamirAliLs
      @AamirAliLs 6 місяців тому

      Have u faced issues?

    • @Lokesh20215
      @Lokesh20215 6 місяців тому +1

      I m also having ev, don't try this method, need 3 connection in plug (phase, neutral, and earth) with MCB (circuit breaker)

  • @mubtasimfuad9286
    @mubtasimfuad9286 5 місяців тому

    the most deadly process to charge your EV

  • @RichiRich11
    @RichiRich11 11 місяців тому +1

    Phase ko kabhi bhi earth ke saath mat joodna... aasa keheel mat kelo bhai

    • @anubhav780
      @anubhav780  11 місяців тому

      Yr dost ka na taxi rent ka kam hai or uske pas electric gadiya h 2-3 saal sy vo apni gadiyo ko ese he charge krta uske m koi dikat ni hue pr bhai ye ek trick h bas permanent esa risk to ni lena chahiye

  • @kdk998
    @kdk998 Рік тому

    kitna time lagta hai bhai ghar mai battery full hone ko??

  • @govindnarayandev5194
    @govindnarayandev5194 Рік тому

    Chini bahot quit hai

  • @germatechdp980
    @germatechdp980 4 місяці тому +1

    TERMS & CONDITIONS : do not try this & destroy your ev this video is just for Views only

    • @anubhav780
      @anubhav780  4 місяці тому

      Charging cars from last 2 years ✌🏻

    • @Ghost-q9v
      @Ghost-q9v День тому

      EV battery destroy hota hai ? 😲

  • @abhishekgoswami2205
    @abhishekgoswami2205 4 місяці тому

    Thanku bhai aapko❤❤
    Mne 3 din phale hi xuv 400 lii tii aur muje earthing ka issue aa raha th pr apki video se sab solve ho gaya

  • @yktewatia
    @yktewatia Рік тому +2

    Once you connect the neutral to the ground, you could shock yourself or others upon touching the metal case. This is because the metal case is connected to the ground. So, if the neutral or live wire is connected to the ground, the ground will become a live wire and create a dangerous situation
    Please don't make such videos, you are risking others life also

    • @svXPs
      @svXPs Рік тому

      I won't recommend this.
      But this will kill someone only in two cases.
      1) As long as RCCB is not provided in the whole circuit.
      2) if he is getting shock from phase to vehicle body.

  • @AmitSharma-jz5xj
    @AmitSharma-jz5xj 9 місяців тому

    Thank you for sharing bhai

  • @amritansumitra
    @amritansumitra Рік тому +2

    This is how you die.

  • @Atharvak1910
    @Atharvak1910 7 місяців тому

    Abe tu akhir me to ghar me hi connect kar rha hai na jaha grounding nai hai. Wire short karke sirf tune car ke charger to bewakoof bana dia ki earthing hai. Battery kharab ho jayegi is se at best and jal jayegi at worst

  • @abhimanyugoyal
    @abhimanyugoyal 9 місяців тому

    DO NOT DO THIS. VERY RISKY.

  • @jagdanand
    @jagdanand 8 місяців тому +1

    Wrong knowledge video.

  • @AdityaSingh-sf6gh
    @AdityaSingh-sf6gh 11 місяців тому

    बकवास है ये न करना कोई अगर फेस फेस दौड़ गया तो हो गई ऐसी की तैसी दो अर्थिंग चाहिए जो ये नही है

  • @harisankarl6292
    @harisankarl6292 4 місяці тому

    This is very dangerous.Pls don't do as in the video.

  • @ravimokk
    @ravimokk Рік тому +1

    Actually if you watch closely you will find that he has connected the ohase to earth. The switch is generally on the phase. And the red wires dint have a 3 pin plug. Any phase interchange and phase goes to earth.... Short circuit. Most foolish video. Most dangerous

  • @KKGOND446
    @KKGOND446 Рік тому

    एजेंसी वालों का कहना है कि 3 फेज का कनेक्शन होना अनिवार्य है,
    तभी Ev कार को चार्ज किया जा सकता है अन्यथा की स्थिति में नहीं।
    अब भला ग्रामीण/गांव इलाकों में कहां 3 फेज कनेक्शन होता है।
    वहां तो सिर्फ सिंगल फेज का ही कनेक्शन होता है।
    तो मेरा प्रश्न यह है कि क्या सिंगल फेज से Ev कार को चार्ज किया जा सकता है?
    मुझे लगता है कि आप इस विडीयो में जिस माध्यम से चार्ज कर रहे हैं,
    इसमें तो सिंगल फेज ही है?

    • @gaurav5800
      @gaurav5800 9 місяців тому +2

      Agency wale pagal hai, jab charger hi single phase ka hai toh 3 connection kyu chaiye. Single phase connection par load 5kw se zyada ho toh koi issue nahi, and meter se direct wire dalo 6mm ki kam se kam. Proper earthing k sath. Koi dikat nhi aaigi

  • @svXPs
    @svXPs Рік тому

    I won't recommend this. And this video shows an image where Phase is shorted to Earth which is deadly (Actually someone should sue him).
    But if you short Earth and Neutral, this will kill someone only in two cases.
    1) As long as RCCB is not provided in the whole circuit.
    2) if he is getting shock from phase to vehicle body.

  • @SDP17
    @SDP17 8 місяців тому

    Marna hai kya 😂

  • @NareshKumar-mg5xj
    @NareshKumar-mg5xj 5 місяців тому

    Delete this video.

  • @AneeshChowdhury
    @AneeshChowdhury 5 місяців тому

    pehle socket to naya sahi laga le fatt raha hai