7 Big Mistakes in RCC Beam | 7 ऐसा ग़लती जो बीम बांधते समय होता है?
Вставка
- Опубліковано 6 жов 2024
- 7 ऐसा ग़लती जो बीम बांधते समय होता है?
आपकी थोड़ी सी गलती के कारण आपका घर गिर जायेगा...!
1. 7 Big Mistakes in RCC Beam | 7 ऐसा ग़लती जो बीम बांधते समय होता है?
• 7 Big Mistakes in RCC ...
2. 8 Big Mistakes in RCC Column | 8 ऐसी गलती जो पिलर बांधते समय होती है?
• 8 Big Mistakes in RCC ...
3. Best Zone of Lapping in RCC Slab | स्लैब के सरिया का लैपिंग कहाँ देना है?
• Best Zone of Lapping i...
4. Best Zone of Lapping in Beam | बीम का सरिया का लैपिंग कहाँ देना है?
• Best Zone of Lapping i...
5. What is Joggle? Why we Bend a bar while Lapping? सरिया का लैपिंग में जोग्गल क्यों देते है?
• What is Joggle? Why we...
6. Reinforcement Lapping zone of Column for Residential Building | कॉलम में सरिया का लैपिंग कहाँ देना
• Reinforcement Lapping ...
7. Big Mistake of Column Top Surface at Construction Site
• Big Mistake of Column ...
8. Big Mistake in Formwork | Shuttering Failure at Construction Site |
• Big Mistake in Formwor...
*Contact Details:-
Email:- civilengineer.deepakkumar18@gmail.com
Twitter: / erdeepak4kumar5
Facebook: / er.deepak4kumar5
Facebook page: / er3deepak4kumar5
Instagram: / er.deepak4kumar5
*Join my Channel Membership
/ @civilengineerdeepakkumar
#RCCBeamMistake #BigMistakeInBeam #CivilEngineering
Bahut badiya se samjhate hai.
dipak sir .
bahot hi badhiya tarikese samjhate hai aap.
👍👍👍👍👍👍👍👍👍👍👍👍
Sirrr bahuta bahuta dhanyvaad sirrr jee
बहुत ही बढीआ जानकारी ,👍👌🙏
और बहुत सही तरीक़े से आपने drawing तथा practical location दीखाकर समझा या है ।
Thanks a lot .👍❤️☝️
Good information....i am going to construction new house....gain so many knowledge about your chnl....nd became engeneer 👍👍
Deepak ji mai civil engineer nahi hoon fir bhi mai aapka videos har baar dekhta hoon. Par mujhe aapse ek help aur chahiye q ki mujhe apne sapno ka ghar banana hai. Aap jo bhi video banaye oosme practical kar bataye Jaise column banana hai to ooski banawat kaisa ho beam ki banawat kaisa ho size kitna lene se ek majboot ghar banega. aur jitne bhi jagah beam ka use hona chahiye wo bhi bataye
👍👍✌️
Thanks for message
Thanks sirji
Thanks
Best explain and also great teaching thanks 🙏
thanks
Bahut achha
Superb lecture sir g..... thanks
Most welcome
Very good vedio.
It covers essential information regarding construction of house.
थोड़ा और सरल भाषा की जरूरत है ताकि लेवल, मिस्त्री और जन साधारण की समझ में ठीक से आ जाए।
It has academic excellency.
Your vedios are very useful.
Very useful and simply described. Your video is helping the common people to prepare for their dream house construction. I appreciate your effort.
So nice of you
सर जी आपका बहोत .........
धन्यवाद ..........
Very deep information thanks
नाइस जानकारी
THANKYOU
excellent lapping zone in top & bottom of beam , hook length formula , hooks 135 degree angle & spacing bar # 👍👍👍👍❤️ # but spacing bar is also necessary to hold the 2nd layer of top central bar since top 2nd layer side bars can be tied to stirrup but central bar can't be tied to stirrup #👍👍
Thanks 👍
आप बहुत अच्छा समझते हैं सर thanks you
sukriya
App ka koi jabab nahi hay sir
tq civel eng sir
Thanksu sir
Sir highway construction ki vedios dal dijiye
Nice video
Very good
Thanks sir plaster ka bhi video banayega
Super
Nice sir
Good
Ok, cover block is made of cement & supporting jal & rainforcement.
एक अच्छे तरीक़े से समझाना , बहुत अच्छा लगा
Very nice video
Aapke jaisa jankari koi nhi deta thankyou so much is video ko banaye aapne
thanks for watching
@@CivilEngineerDeepakKumar most welcome
sir ji apna aur apno ka khyal rakhna Boss
You are better suggestion sir
Bhahut Achha vidios
Bhut Achha gyan diya deepak Ji. Thanks.
welcome
Thanks sir for information
Thanks bhai
Verynice
Sir aap bahut accha samjhate hai.
Thank you 😊
thanks
aap ke pas no . hai sir ka
Thank you
Thanks sir.. Friends Spacer bar should not be less then 20 mm because if it's less then 20 mm then aggregate not pass from that space..
Ok, thanks
Thank You Very Much Sir
Very informative video, Thanx
Sir Ur words of civil engineer can understand only experience people who is in this work.
But what about common man 2 understand?
Please explain in practical or graphic design so it can b easily understand
Respected Sir, it is a very useful technical video. Thanks for knowledge sharing.
Thanks
@@CivilEngineerDeepakKumar sir apse bat ho sakti he
Good sir thank you
Sir, pehele colom ke uper chhat lagaye ya dewar baneka uske bad colom ke uper chhat lagaye? Which is the best?
Very good sujesan ****
Very Useful Info for avoid mistakes.
Glad you liked it
thank you dipak sir
Most welcome
Very nice sir g.kindly make the video on Highway Engg. Thanks
Will try
awesome sir
its very helpfull video
Thank you sir you helped me lot..
Very good information
Thanks
Good teaching
Thanks and welcome
Bhai aap bahut struggle krte ho. Bhaghwan aap ko hamesha happy rakhe.
sukriya bhaijaan
Good work
Sir,, column & Beam ki janiari hui,,,,pls sir, jaise 40 by 30ka plot hai,,, Iron rod ,,,,coloumn ,,,beam k sath kaise calculation kare,,,, pls send video bheje thanks,,,
excellent RCC floor ( roof ) beam steel bar bottom & top structure & steel ring bend structure basic knowledge by civil engineer Deepk Kumar #
Best information.thanks sir.
Thankyou sir.........
Thanku sir
Very nice sugestiion
Nice information
Thanks
Make video on Pt slab
Bhaiya todha laminate or tiles flooring pe video banao na
Genuine information
Sir, thanks for the informations.
Thank
Stirrups ka position alternate kyu karna hai koi reason?
Excellent SINGLE SHOT
Hay I want to build home 45 by 50, want to share roughly made map, may i
V nice
Dear. 23x60 feet ke slab me kitna saria lagega. Pl give mm wise details.
1380 mtlab ring ki sariya samit 14 kwintal
Please front elevation pr ap koi video banaye practical batayen please
thanks sir
Most welcome
Bahut achchha
Very useful video
Good job. Dear DEEPAK Jii, I like it very much and understand your videos.
And would like to request to show a video of a three storey house for 3bkh with attached toilet & Bathroom in a standard sizes, drawing room, Kitchen-cum-dining hall, verandah at front & balconies, staircase in East facing plot. Thank you.
Check about tab for house plan
Architecture vs civil pe vedio banao
Sir hum new 4 storey building mein coloum ki size 15.24 x 60.96 rakha hai kiya ye teek sahi hai k nahen ? Thanks
Structural engineer se banaya hai tho thik
Thank you so much sir
Tysm sir ❤️
Welcome 😊
Good character
Best
Plaster karte wakt agar cement ke sath white cement milana he to maximum kitni mila sakte he ?
I love this video. Sir thoda hindi sabd me samjhaye hard word me nhi. 👌
Good sir
Thanks and welcome
Nice
Best presentation
Concrete me jo sand use karte hai usme mitti kitni hai, sand ki quality kaisi honi chahiye, cement ki grade konsi use karni chahiye, cement- sand- crushed stone and pani in sab ka mixture ka ratio kitna hona chahiye, ye bhi reasons hai leakage ke..
Good.G
informative video
Namaste sir, kya d50 lapping k bad sariya ko Belding karna thik rahega? Store kiya hua sariya ko rusty ho jaye to kya kiya jaye kyoki rusty sariya dukandar fir wapas nahi karta hai.
Binding wire nickel Kiya hua use kar sakte hai.
Sir 28*30 South face corner ka koi house plan he to send kijiye
Make a video on it
34charai 40lambai ka home palan bataye
Sir I saw the ring hook has been bent at 90 degree in your video. Why did you allow that sir?
Yes
Yes I observed the same. Why it is not at 135 degrees?
45 degree best
Sir depth work use matt kijiye udhar, width word use kijiye logon ko confusion hone lagega
Sir g bottom to sahibut top kakaise
Good information sir