किसकी गलती के कारण बीम क्रैक हुआ है? | Reason of Beam Crack of House
Вставка
- Опубліковано 7 гру 2023
- If you're wondering why your house's beam crack is appearing, then keep reading! In this video, we'll share with you the reason why beam cracks sometimes occur in houses, and how you can prevent them from happening in the future.
Be sure to watch the entire video for tips on how to repair beam cracks in your house, as well as advice on prevention measures. With careful planning and preventive measures, you can keep your house from cracking in the future!
Your queries:-
ghar banane ka tarika
diwal me darar aane ka karan
ghar jhukane ka karan kya hai
ghar girne ka karan kya hai
chhat jhukane ka karan kya hai
plinth beam me darar
plinth beam me sariya badhne ka sahi tarka
lintel beam ka size kya rakhe
beam mistakes
plinth beam banane ka tarika
ghar me diwar ki motayi kya rakhe
purane makan ka maintenance kaise karen
building girne ka karan,plinth beam
Contact Details:-
1. For Sponsorship and Business
Deepak Kumar
Mob: +91- 9523101369 (also WhatsApp)
Email:- civilengineer.deepakkumar18@gmail.com
My Social Network
1. Facebook:- / civilengineerdeepakkumar
2. Instagram:- / civilengineer.deepakkumar
#Crack #Beam #House
#civilengineerdeepakkumar
#civilengineeringdeepakkumar
#engineerdeepakkumar
#erdeepakkumar
#deepakcivilengineer
#deepakkumarcivilengineer
#civilengineer
#civilengineering
Kahi galti ho gayi hai to room me steel ka beam dal sakte hai. Bahri dewar aur partisan me 9 inch ka dewar bahut jaruri hai. Steel ka jyada use thick nahi hai. Ajkal steel ki jyada bat ho rahi hai. Ghar me steel kam se kam use karna chahiye. Flat jab banta hai to usme steel jyada lagta hai. Agar ghar banana hai to 2 manjil tak steel jyada jaruri nahi hai. 9 inch ka dewar par achha majbut ghar ban jayega.
Shukiria sir
Sir hamare colm 10/12inch Hain beam size 12/10inch ka distance hain 14feet hain or beam ka sariya 16mm ka 6pc deya hain thik hain Aya galti huwa hain
Sir ji ydi column to column jyada distance hota h to bich me hidden beam de skte h kya ...?
Sir 15×30 ka plot hai har EK 15 feat per 12 / 9 ka pillar de sakta hun 12 mm ke sariya
How much weight a beam as you have suggested can take? Can we build a room 9 inch thick brick wall over such a beam?
Ye problem solve ho sakti hai retrofitting se se beam tod kar sahi ki ja sakti hai
Dear....sir mera colum distance 17.5 fit 6 rot 12 mm ka diya hu or colum ka size 12/12 ka hai koi problem to nahi hoga sir...plz reply me...thnx
Mera 30 ft× 50 ft ka 3bhk plan mein total 17nos coloum aaya including stayer case maximum distance between two coloums are 14.8 inc and I have provided 12×14 Inc 12nos coloum with 8nos tata tiscon 16mm and 12 mm mix and 5 nos 12×12 inc with 8 bars and beam size 10×16 inc as per architect suggestion location Assam... ghor majboot bonega but mein kamjur ho geya financially 😢
18 feet span between two column 6 steel 12mm with 8mm ring column size 9 inch beam size 9*12 wall construct along column...
Sir koi problem hoga ya nhi plzz reply ......
Sir, beem aur colm distance 20ft hai aur joint main crack huwa, uska solution chahiye
❤❤❤
Upto span 18Ft Column size 9" × 15" But more then 18 Ft size must required 9" × 18" If steel is less
Mera slab electrical pipe ka pas 1 year ke ander hi crack ho gya hai bahut pareshan hai kaise repair Kiya Jai??
Namaskar sir
Depth of beam jyada dene se sahi rahega bd^3/12
Sir hamare 21fit span h hum ne beam ki size 12by15 rakha h or sariya batam me 25mm 3 pic and top me 20mm 2 pic and midal me 16mm 3pic phir bhi crack ho Gaya 😢
Kya hm Beam k uper over head tank water rakh sakte hai ?? Koi problem to nhi hoga na 🤔🤔
Sir hamara ghar v thoda dekh lijiye kya kya mistake he
Sir mera hall 40x90 ka hai usme column ka size kya hoga steel kon si dalni padegi
Aur sir beem ki 40 feet duri hai usme beem kitne size ka hoga kon si steel dalni padegi sir please help me 🙏
2 pic extra 12mm ki jagah par 16mm extra de sakte he kya
Aapako compchalana nahi attached to Normal trike se bataiye
Sir first floor k uper construction nahin krna ho to kya first floor ki walls pr slab k saath beam dena jaroori hai?
Hnn
मिस्त्री सही कह रहे हो, पर जनता मिस्त्री का काम नही जानती। लगता है अब इंडियन public को मिस्त्री का tranning लेनी पड़ेगी।
Sar Jaise mujhe 5 foot ka chhajja nikalna hai to uske niche ka colum kaun se size Ka hona chahie hamare sare colum 1212 fitte Hain 9/9 ke colum hai is per hamara 5 foot chhajje ka load lega ya nahin dharavi pura banaa nahin abhi ghar banaa nahin hai sirf do column uthe hue hain yadi 9/9 ke colum per load lega 5 foot ka chhajja to theek hai nahin to Abhi to starting hai abhi sudhar sakte hain main Arvind Kumar
Sir 10 ft ka beach main kitna size coloum,plinth bim or wall bim dena chahiye 2 majil building ke liye please reply me
@@purneshkumar750 ok sir thanks
@@purneshkumar750 or sir siriya ka size kitna mm ka chaiye
Sir ya galti hogya hai to kya kare esake baad
12*12 ki chhat me 8mm sariya lagaye ya nahi
Mera v 9*9 ka pillar hai aur 22 feet ki chhat ka beam dalna hai...😢😢😢..apki method se daldun kya...new pilar nahi bn skta ab
Thanks for noticing ing...koi dikkat nahi hogi na sir... whether any other improvement can be done???...
Kya hua Bhai, mere sath bhi yahi dikkat hai. Apne kya solution nikala fi? @@swadhinkumarbehera6560
Solution Kiya hai
Sir 30/23 ka house map plan chahiye
Sir isme column ka base kitna /kitna ka hona chahiye or uska structure steel ka kaise hona chahiye
Kindly it's a request
ज्यादा से ज्यादा 12×12ki distance 9×9 kaa beam aur column bhi vaise 9×9 isey jyada nahi
Sir aap UA-cam k thumbnail kon sa app sa banata ho
power point
Sir mera column size 10×14 aur
Beam-10×11
distance..14×15
ek column mai 16mm 4pc 12mm.2pc
Kya ye thik hoga aur kitna tak upar sakega🙏♥️
3storey is safe
मेरे घर मे पिलरस् मे क्रेक है एक साइड के सभी पिलरस् मे घर दो मिन्जिल् है, घर मे क्रॉस बीम भी नहीं है, अभी क्या कर सकते है कृप्या बताएं
Sir 17*40 ka House plan chahiye
Contact me
Do coloum ke bich ki duri 16.1 feet hai coloum 9/12 hai aur beam 9/12 de Raha hun kya ye theek hai ?
Beam 9 by 24 hoga
Kya 9/15 me 6 rod 12mm ka de sakte hai ??
Bhai steel to 16mm se kam to dena hi nahi chahiye or rcc me main role cement ka hota h jitna accha masala hoga utna hi majboot hoga
Sir mujhe 20 feet ki beam Deni h. Kya size rakhio ?
10 inch wide by 20 inch depth beam me 3 rod 20mm top me and 2 rod 20mm bottom
Bich me 12 mm ka 4 rod
Iska vi moye moye ho gaya mere jaisa .
oh
Gha banaruhu
टाइम ज्यादा ले रहे हैं बताने में
Samaj aaya ki span 16 feet se jyada nahi rakhana hai😂😂😂
Oh
Aap ka butane ka tarika hi galat hai jyada style sahi nahi hona
Ye agar ek lintel hota to bhi ye na hota. Brick se load transfer hoke lintel tak aa jata aur load maintain ho jata
Kuchh jyada samajh me nahi aaya
सर contact no. चाहिए
😂😂