In this model compressor motor, no matter which direction the motor rotates, air will come out through the output pipe regardless of the direction of rotation
Execelente pero veo que el giro quedó invertido ya que la descarga está como succión y viceversa me imagino que solo hay que cambiar de posición el capacitor de arranque saludos
Hey great job.. Any idea what the consumable or replacement seals are? I imagine you don't need to tear down the motor and just access the seals from the top
Why is the pump sucking in air? Is that an air compressor or an suction pump? How is the thermal protection wired? Was the Keltron 20uf the RUN capacitor? How did the motor start without a start capacitor? Each set is one continuous wire.... 8 large slots → 4*4 50 turns 8 small slots → 4*6 75 turns 4 small slots → 4*4 55turns 4 small slots → 4*6 85 turns Run Winding SWG-22.5 Start Winding SWG-23 4 sets 500grams 4 sets 530grams → 4*4 50 turns → 37.5cm → 4*4 55 turns → 35.5cm → 4*6 75 turns → 42.0cm → 4*6 85 turns → 40.5cm Interesting tutor learning how to rewire!
If the thermostat is to be attached, common starting wire and running wire should be done while giving the winding connection and after that the thermostat is attached to that wire. Since this motor has four pole winding, the motor has more power and there is no shaft over tight, so no starting capacitor is required, running capacitor is sufficient.
Hi I have the same unit And it's really getting hot very quickly And the motor only start when the tank is empty So if the tank contains any bar it won't start
Watch below video these two motors winding method is same this video includes winding diagram connection and all👇 ua-cam.com/video/J_YNjdXNW6w/v-deo.html
@@Hipowerelectricworks ok ill attemp your method...im from philippines and my rewinder friend i think had it wrong when starting coil is same thickness as running coil...what is the reason for that if i may ask? Why starting coil is thinner? Is it ok to have same coil thickness? His rewinding job just last like a year and now its humming again capacitor is ok..thanks for you feedback
So one motor and one or two pistons? One filter one piston? If two pistons - output in Watts is doubled? Rpm doubled or same? There are many variants on market.... What failed first on these motors?
The motor have 2 piston. There is only one Air filter Rpm is 1440 but when air tight the speed decreases. It doesn't get as strong a air as you get from an oil compressor
Your motor is running backwards 😹 Air is going out through the Air filter and the Air exit is the one sucking the Air if you connect the exit to the tank all the air inside the tank Will exit to the Air filter…
@@pinoyuzie1557 In this model, no matter which direction the motor rotates, air will come out through the output pipe regardless of the direction of rotation
If it is a motor with aluminum winding, when the motor is manufactured in the factory, the appropriate wire gauge and turns will be used.When we rewind it, it is best to use the same wire gauge and turns that was on the motor before.
Wheight calculate Old aluminium coil wheight × 3 = copper weight Example:- Aluminium Running coil wheight 150 gram 150 gram ×3 =450 gram 450 gram copper wire -------------------------------------------- For motor:- 👇 If it is a motor with aluminum winding, when the motor is manufactured in the factory, the appropriate wire gauge and turns will be used.When we rewind it, it is best to use the same wire gauge and turns that was on the motor before. For mixer grinder and ceiling fan:- 👇 If the factory winding of mixer grinder and ceiling fan is aluminum then it is better to use 1 gauge less copper wire while rewinding.
Help me sir me ne motor ki winding theek ki turns b barabar Dale wire gauge b theek dala lakin motor 30 pressure p band hota ha jab Tak pura air bahar nahi nikalta tab tak motor start nahi hota ha mujhe is me air 90 Banna chahiye tab motor band honi chahiye aur jab is me 90 air me se kuch air nikle gi tab fir se start honi chahiye maa kasam fas gaya costomer ke saat panga ho gaya wo bolta ha mujhe Naya Lake do aap ne kharab kar di plz plz plz help me sir aap ki meharbani hogi me gareeb aadmi hu
Very helpful sir thanku so much 😊
Exelente, gracias x compartir tu experiencia..
Thank you
Good jobe bro good luck
Thank you
I think it is working in reverse, it should be sucking from the air filter.😊
In this model compressor motor, no matter which direction the motor rotates, air will come out through the output pipe regardless of the direction of rotation
Thank you so much Boss👌
Execelente pero veo que el giro quedó invertido ya que la descarga está como succión y viceversa me imagino que solo hay que cambiar de posición el capacitor de arranque saludos
no, solo es cambiar el filtro para el otro lado, se esta diviertiendo el nene
@@tec375 In this model, no matter which direction the motor rotates, air will come out through the output pipe regardless of the direction of rotation
Hey great job..
Any idea what the consumable or replacement seals are? I imagine you don't need to tear down the motor and just access the seals from the top
Very nice job
Thank you
Very informative presentation and thank you
You're most welcome
@@Hipowerelectricworks berapa ukuran tembaga R dan S kak
Hey! Great job with this video, thanks a lot! What kind of grease shoud i use to lubricate?
Do not use grease or oil on the cylinder and piston parts of this motor
@@Hipowerelectricworks But on other moving parts, can i grease them?
Why is the pump sucking in air?
Is that an air compressor or an suction pump?
How is the thermal protection wired?
Was the Keltron 20uf the RUN capacitor?
How did the motor start without a start capacitor?
Each set is one continuous wire....
8 large slots → 4*4 50 turns
8 small slots → 4*6 75 turns
4 small slots → 4*4 55turns
4 small slots → 4*6 85 turns
Run Winding SWG-22.5 Start Winding SWG-23
4 sets 500grams 4 sets 530grams
→ 4*4 50 turns → 37.5cm → 4*4 55 turns → 35.5cm
→ 4*6 75 turns → 42.0cm → 4*6 85 turns → 40.5cm
Interesting tutor learning how to rewire!
If the thermostat is to be attached, common starting wire and running wire should be done while giving the winding connection and after that the thermostat is attached to that wire.
Since this motor has four pole winding, the motor has more power and there is no shaft over tight, so no starting capacitor is required, running capacitor is sufficient.
Thank you❤
I have a compressor like this but it doesn't go up to 90psi it reaches 60 PSI what could it be?
If the piston washer is compliant then this will happen. and the air will be low
Hi
I have the same unit
And it's really getting hot very quickly
And the motor only start when the tank is empty
So if the tank contains any bar it won't start
Check the capacitor
Also check if the bearing is tight
I don't understand how you fixed the starting coil can you explain?
Watch below video these two motors winding method is same this video includes winding diagram connection and all👇
ua-cam.com/video/J_YNjdXNW6w/v-deo.html
The oil free compressor motor winding is not fully covered in the video, the video focuses on how to removed and set the motor.
Buen trabajo.
Thanks!
You're most welcome
Keep watching my channel
Thank you
This guy is really good..cheers from philippines!
Boss is it ok no varnish? No problem?
Varnish must be poured
@@Hipowerelectricworks ok ill attemp your method...im from philippines and my rewinder friend i think had it wrong when starting coil is same thickness as running coil...what is the reason for that if i may ask? Why starting coil is thinner? Is it ok to have same coil thickness? His rewinding job just last like a year and now its humming again capacitor is ok..thanks for you feedback
Mai bhi 1 hi moter 2 baar banaya lekin bahot jyada hit ho raha hai 1 baar jala fir banaya vibrate bhi kara raha hai kya problam ho sakta hai
yadi valve plate or piston washer complaint hai, to motor garam ho jaegee, adhik vibration karegee, aur air filling mein deree karegee.
Silinder and piston position be check karo
Could it made into 2 pole 2800rpm? Thx
Can't make 2800 rpm
👏👏👏👏👏
How much amp take?(full load)
My rewind motor over heat all process complete but don't catch fault? Help
Check that the alignment between cylinder and piston is correct.
A difference in alignment can lead to low air and motor heating issue
Ampere will vary depending on the motor's wattage and not all motors will be the same
Dear brother kindly tell me about the parts name which you are using at 20:29 time of this video.
Also called piston ring or cylinder sleeve
Bos aking my kaso umuugong lang cya ano deperencya bos
So one motor and one or two pistons? One filter one piston? If two pistons - output in Watts is doubled? Rpm doubled or same? There are many variants on market.... What failed first on these motors?
The motor have 2 piston.
There is only one Air filter
Rpm is 1440 but when air tight the speed decreases.
It doesn't get as strong a air as you get from an oil compressor
Ganyan cya un gnagawa nyo
Sir .....esska aluminium winding data dedo nah...........sabb appke bharose hai
The same guaje and turns use Karo
Winding data video me he
Your motor is running backwards 😹 Air is going out through the Air filter and the Air exit is the one sucking the Air if you connect the exit to the tank all the air inside the tank Will exit to the Air filter…
@@pinoyuzie1557 In this model, no matter which direction the motor rotates, air will come out through the output pipe regardless of the direction of rotation
Sir ji yahi motor mere pass he ole free vali elmoniyam se coper me krani he app address batao me bhej deta hu
Mere workshop bahut door he me Kerala me hu
Sir ye connection series ya parallel ❤
Series connection
Price for windig
The amount will vary depending on the model of the motor and will vary if other spare parts bearing, piston washer etc...need to be replaced
Bai old winding aluminum wire new winding copper wire how to calculate wire gauge and turns please explain
If it is a motor with aluminum winding, when the motor is manufactured in the factory, the appropriate wire gauge and turns will be used.When we rewind it, it is best to use the same wire gauge and turns that was on the motor before.
Thanks bai replied
Master San Po location nyo
India
I have to do repair
Aluminum swg to copper swg hwo to calculate ?
Wheight calculate
Old aluminium coil wheight × 3 = copper weight
Example:- Aluminium Running coil wheight 150 gram
150 gram ×3 =450 gram
450 gram copper wire
--------------------------------------------
For motor:- 👇
If it is a motor with aluminum winding, when the motor is manufactured in the factory, the appropriate wire gauge and turns will be used.When we rewind it, it is best to use the same wire gauge and turns that was on the motor before.
For mixer grinder and ceiling fan:- 👇
If the factory winding of mixer grinder and ceiling fan is aluminum then it is better to use 1 gauge less copper wire while rewinding.
Tq sar
@@Hipowerelectricworkshelp me
Ok
Of course it's oil less it's electric
Smart, the air compressor rods and pistons is oil-less, usually they have oil and oil separator
Cup wala Part kaha milega, Mera CILF air compressor ka dono cup ghis gaya Hai.....pls Vai Mujhe parts ka jugar kor do.😢
Google par oil free compressor sylinder piston ring khojen aur yah aapko online mil jayega
This is aluminium wire or pure coper wire sir?
Copper wire
How much the rpm and capacitor uf?
@@HansBaltazar 1440 rpm
Running capacitor 20 mfd
Thanks you 🙂
What 's coil number?
You mean wire gauge
Running coil SWG - 22.5
Starting coil SWG - 32
Is ma kn sa num ki ware Dali ha ap na
Running guage - 22.5
Starting guage - 23
@@Hipowerelectricworks mana to is ma running ma 24 or starting ma 25 Dali ha
Help me sir me ne motor ki winding theek ki turns b barabar Dale wire gauge b theek dala lakin motor 30 pressure p band hota ha jab Tak pura air bahar nahi nikalta tab tak motor start nahi hota ha mujhe is me air 90 Banna chahiye tab motor band honi chahiye aur jab is me 90 air me se kuch air nikle gi tab fir se start honi chahiye maa kasam fas gaya costomer ke saat panga ho gaya wo bolta ha mujhe Naya Lake do aap ne kharab kar di plz plz plz help me sir aap ki meharbani hogi me gareeb aadmi hu
कैपेसिटर कितने mfd का होता है? क्या इस मोटर के कार्य क्षेत्र में वोल्टेज है? जाँच करें कि क्या मोटर के चलने के दौरान वोल्टेज गिरता है
Please sar explain
Apna no do
Sar aapka contact number Milega kahan per hai aapki shop