Sir m aapki sabhi video dekhta hu aaj wali video bhut hi kamal ki h aaj kisi phle aadmi ne unlike kiya pta nhi kon h ye m uske bare me khna chau ga bilkul hi non tactical aadmi tha
Bajut achhi bat hai ki aap meri sabhee video dekhtey hai. Kya merey video dekney sey aapki intelligence bhee badhtee hai ya nahee. Uttar correct Dijiye.
@@GKAgrawal2 sir intelligence to bhut jada badhi h mene electric se iti kiya h. Wha par mene apni life ki sabse jada nowleg li ab ese aap aage badha rhe hen. Iti ke syllabus me mere Q. Ka answer nhi milta tha wo sab kuch aap bta rhe hen. Sath ki sath jo iti me nhi tha un topic ke link ko m apne iti wale instructor ko bhejta hun taki wo aane wale student ko or bhi jada nowleg de ske
@@GKAgrawal2 sir mera ek Q. H 32kva line me frequency kitni hoti h m us line me se mutual induction se bijli chori karna chata hun mujhe pta h mere ghar wale esa kabhi nhi karne denge or ye regular karna thik bhi nhi h m bas ek baar ese 220 volt nikal kar ghar walo or dosto ko dikhana chata hun
Sir I have doubt , current in AC passes though zero two times in 180 deg cycle so can we say that there is a chance that we will get a shock and thrown away, were as in case of DC current we will get shock and stuck into it because it is a constant current. Plz reply
सर आपने एक्सप्लेन अच्छे से किया है। ओर सारे फैक्टर सही हैं। पर मेडिकली बात करें तो ac बॉडी में फ्लो होने पर हार्ट फेब्रिलेसन होता है, जिसमे हार्ट मोबाइल की तरह भइब्रेट करता है। उस समय हार्ट पम्प 30% ही करता है। पर जब डीसी फ्लो करता है तो हार्ट चोक हो जाता है, पम्प जीरो हो जाता है ओर इसको फिर से रिस्टोर भी डी फेब्रिलेटर द्वारा ही सम्भव है, cpr के जरिये भी चांस कम है। ओर ऐसा इस लिए होता है क्यों कि हार्ट भी पल्सेटिंग dc करंट पर चलता है जिसका फ्रीक्वेंसी 1.5 hz होता है ओर मैग्नीट्यूड 0.05 वोल्ट होता है। ओर इस कारण से बोला जाता है कि dc खतरनाक होता है। बाकी आपकी सारी फैक्टर सही है। Ac कम करंट पर ही झटका देता है क्यों कि कपैसिटिव रिएक्टेंस के कारण बॉडी का कॉन्टेक्ट रेसिस्टेन्स कम जाता है, ब्रेकडाउन भी कम हो जाता है। ओहि आप फ्रीक्वेंसी बढ़ाने से ब्रेकडाउन वोल्टेज में कमी आती है तो जादा फ्रीक्वेंसी के वोल्टेज का करंट भी बढ़ जाता है। मोबाइल चार्जर के फेराइट कोर ट्रांसफार्मर में जो पिला टेप यूज होता है उसका ब्रेकडाउन 3kv/mm होता है। ओ टेप मैं यूज कर रहा हु।3000 की 1 रोल मिली है 50 मीटर की। ओर वही dc में फ्रीक्वेंसी नही होने के कारण रिएक्टेंस नही होता।
Sir inverter का current attractive in nature hota h ya phr a. C or aise hota kyu hai ki. Ek current body ko fek deta h durr or ek current body ko chipka k rkhta h device se
Sir as you said current is more dangerous. And a male can get shock from current more than 9 mAmp. Then why we don't shocked by electric welding machine which operate at very high current like 250 Amp, 350 Amp. I saw sometime welder touch electrode and earth in welding machine at same time without protection but there is not shock. WHY?
Is Questions ma Jub hum multi-meter sa voltage check krka hai toh kabhi-kabhi..... (Phase or Natural 230volt Phase or Earth 235volt Natural or Earth1to3volt) Hota hai. Question Phase Or Earth ma Phase or Natural sa jadha voltage kayo hota hai?
If you have only a line wire coming to a device.. what's the consequence if you connect this line wire and complete the circuit by an earth connection to the ground in the room..with no neutral wire..
Aap jaise koi nhi sir very helpful vidio sir
Comments welcome
Awesome video. I love your teachings. Thanks
Thank you sir for the video on this topic. Really enhanced my knowledge of electric shock.
Very nice explanation sir👌👌
Nice explanation
Thanks sir for your valuable information.😊🙏
So much of useful information
V good
Excellent information. Thanks
Great Sir
Wonderful video with lot of information
Nice example sir
सर आपकी जितनी तारीफ़ की जाए उतनी कम है। आप जैसे टीचर अगर मिल जाए तो सच में जिंदगी कुछ और ही हो जाए। भगवान आपको लंबी उम्र दे।
Sir m aapki sabhi video dekhta hu aaj wali video bhut hi kamal ki h aaj kisi phle aadmi ne unlike kiya pta nhi kon h ye m uske bare me khna chau ga bilkul hi non tactical aadmi tha
Bajut achhi bat hai ki aap meri sabhee video dekhtey hai. Kya merey video dekney sey aapki intelligence bhee badhtee hai ya nahee. Uttar correct Dijiye.
@@GKAgrawal2 sir intelligence to bhut jada badhi h mene electric se iti kiya h. Wha par mene apni life ki sabse jada nowleg li ab ese aap aage badha rhe hen. Iti ke syllabus me mere Q. Ka answer nhi milta tha wo sab kuch aap bta rhe hen.
Sath ki sath jo iti me nhi tha un topic ke link ko m apne iti wale instructor ko bhejta hun taki wo aane wale student ko or bhi jada nowleg de ske
@@GKAgrawal2 sir mera ek Q. H 32kva line me frequency kitni hoti h m us line me se mutual induction se bijli chori karna chata hun mujhe pta h mere ghar wale esa kabhi nhi karne denge or ye regular karna thik bhi nhi h m bas ek baar ese 220 volt nikal kar ghar walo or dosto ko dikhana chata hun
@@GKAgrawal2 sir 32 kva transmission line me ki frequency kitni hoti h plzzzz reply
50 Hz
आपको सलाम सर
सालों साल से इलेक्टिक काम करते है
मगर बिजली पावर किया होती है अब पता चल
Thank you for the information. thank you sir.
Sir,star delta control pe ek video chahiye. Pse sir. U r good explaner.
Thanks sir
I love your voice sir .
Sir,keep doing such informative videos
Sure
Sir AAP book bhi provide karwate h qya
नहीं
Electronic or Electricals applications ma 1to 5star rating k kay matlub hota hai?
श्रीमान जी कुछ उन्नत प्रकार के सर्किटों पर विडियो बनाऐं। धन्यवाद
Which types of RCCB's are available and which factors affect while choosing RCCB ?
E.g For Residential purpose and another for Industrial.
Sir,nice video with good info.but one doubt,dc at high voltage is danger than ac having frequency 50hz .am I correct .pls reply me sir.
Frequency and voltage level are 2 different things. Comparison is done with equal voltage of AC and DC.
Thank you sir
Sir I have doubt , current in AC passes though zero two times in 180 deg cycle so can we say that there is a chance that we will get a shock and thrown away, were as in case of DC current we will get shock and stuck into it because it is a constant current. Plz reply
Electric shock is not a magnetic force of attraction or repulsion. It is biological process.
सर आपने एक्सप्लेन अच्छे से किया है।
ओर सारे फैक्टर सही हैं।
पर मेडिकली बात करें तो ac बॉडी में फ्लो होने पर हार्ट फेब्रिलेसन होता है, जिसमे हार्ट मोबाइल की तरह भइब्रेट करता है।
उस समय हार्ट पम्प 30% ही करता है।
पर जब डीसी फ्लो करता है तो हार्ट चोक हो जाता है, पम्प जीरो हो जाता है ओर इसको फिर से रिस्टोर भी डी फेब्रिलेटर द्वारा ही सम्भव है, cpr के जरिये भी चांस कम है।
ओर ऐसा इस लिए होता है क्यों कि हार्ट भी पल्सेटिंग dc करंट पर चलता है जिसका फ्रीक्वेंसी 1.5 hz होता है ओर मैग्नीट्यूड 0.05 वोल्ट होता है।
ओर इस कारण से बोला जाता है कि dc खतरनाक होता है।
बाकी आपकी सारी फैक्टर सही है।
Ac कम करंट पर ही झटका देता है क्यों कि कपैसिटिव रिएक्टेंस के कारण बॉडी का कॉन्टेक्ट रेसिस्टेन्स कम जाता है, ब्रेकडाउन भी कम हो जाता है।
ओहि आप फ्रीक्वेंसी बढ़ाने से ब्रेकडाउन वोल्टेज में कमी आती है तो जादा फ्रीक्वेंसी के वोल्टेज का करंट भी बढ़ जाता है।
मोबाइल चार्जर के फेराइट कोर ट्रांसफार्मर में जो पिला टेप यूज होता है उसका ब्रेकडाउन 3kv/mm होता है। ओ टेप मैं यूज कर रहा हु।3000 की 1 रोल मिली है 50 मीटर की।
ओर वही dc में फ्रीक्वेंसी नही होने के कारण रिएक्टेंस नही होता।
Nice video sirji 👌
*Mai vi electrical and motor rewinding videos bnata hu*
DC or Ac Current/ Voltage body ka temperature par bhi koi effect karka hai?
Good question, parantu mujhe eska uttar nahee gyat hai.
Koi video Electricals BSI rules pr banaoo
Air me led bulb repair karta hu par hab use pf ki madad se salata hu to kabhi kabhi pf fat jata je .
105j 400v vala bhi fat jata he iska kya reason he
sir, how much voltage can our dry skin resist , AC /DC both
Please make video Teasers used by armee guy
sir why at 50 hz ac is dangerous not on other freq is there any relation with freq.
It is dangerous for all frequency, but more around 50 Hz. This is nature law.
Sir welding machine se current nahi lagta and car ki high current battery se nhi lagta...Ans plz
Single phase or three phase AC supply ma Energy metre lagta hai?
Kay DC supply ma bhi Energy metre lagta hai?
Energy meter ki vaha jaroorat hai jab bijli kharidtey hai. DC tho kharidte nahi, then energy metrr ki koi jaroirat nahi hai.
Namshkarrrr😪
👌🇮🇳
Sir,what is the scientific logic of Electric Shock difference between male n female?
I do not know.
male ka female se resistance jada q hota he?
Kyo ki females ki skin mulayam hoti hai
AC supply ma natural or Earth ma voltage milta hai toh,
DC supply ma Negative or Ground ma voltage milaga?
Sir inverter का current attractive in nature hota h ya phr a. C or aise hota kyu hai ki. Ek current body ko fek deta h durr or ek current body ko chipka k rkhta h device se
ua-cam.com/video/WnEIKu7WBkQ/v-deo.html
Sir as you said current is more dangerous. And a male can get shock from current more than 9 mAmp.
Then why we don't shocked by electric welding machine which operate at very high current like 250 Amp, 350 Amp.
I saw sometime welder touch electrode and earth in welding machine at same time without protection but there is not shock.
WHY?
350 A current flow in the machine, not in the human. Current must flow in the human body to get shock.
Is Questions ma
Jub hum multi-meter sa voltage check krka hai toh kabhi-kabhi.....
(Phase or Natural 230volt
Phase or Earth 235volt
Natural or Earth1to3volt)
Hota hai.
Question
Phase Or Earth ma Phase or Natural sa jadha voltage kayo hota hai?
Jyada, ya less ya barabar, kuchh bhee hoo sakta hai.
@@GKAgrawal2
Iski pachan kasa hogi?
Agar natural Or Earth ki wire same mm, same colour ki hai?
A app mo. Nabar mil sakata he
220 volt ac or DC danger
If you have only a line wire coming to a device.. what's the consequence if you connect this line wire and complete the circuit by an earth connection to the ground in the room..with no neutral wire..
Watch my video, Why load is not connected between line and earth,
As per Kirchoffs law if transformer has earthed the star point then he feel shock otherwise not circuit is not closed and no current fliws
Watch my video, why the neutral of the transformer is connected to earth.
डीसी से जादा है
Thank you Sir
Thank you sir