Viessmann Vitodens 100 No Hot water Boiler Service - Viessmann Boiler

Поділитися
Вставка
  • Опубліковано 28 лис 2024

КОМЕНТАРІ • 233

  • @Britec09
    @Britec09 5 років тому +11

    Love your videos Allen, keep up the good work mate.

    • @AllenHart999
      @AllenHart999  5 років тому

      Thank you for your kind words.

    • @reyanshtrey9361
      @reyanshtrey9361 3 роки тому

      a trick: you can watch series on flixzone. Been using it for watching lots of of movies lately.

    • @fletcherpeyton1963
      @fletcherpeyton1963 3 роки тому

      @Reyansh Trey Yea, I have been using Flixzone} for years myself =)

  • @vbsbkjer2
    @vbsbkjer2 Місяць тому

    Thanks so much for your video, we have just moved into a 1980's house, and I have an Engineer coming back to fit a new heat exchanger as I have fluctuating water temp. but just warm at the shower. The Engineer came and found the problem. And has ordered a new heat exchanger. I will have the boiler serviced at the same time. I now know what the problem is and know that these boilers are good. Again thank you.

  • @dcreaven1
    @dcreaven1 3 роки тому +1

    Thanks Alan , I’m a newly qualified gas engineer and your videos have got me out of trouble many times

  • @Nick_G7IZR
    @Nick_G7IZR 3 роки тому +1

    So just wanted to thank you for helping me fix our variable hot water upstairs. Downstairs was fine, but upstairs was variable. I cleaned the heat exchanger plate but also topped up the expansion vessel and all is fine now. After her initial doubt (when I flooded the kitchen because I hadn't fully drained it) I now have a happy wife! :)

  • @hugebartlett1884
    @hugebartlett1884 Рік тому

    That was well worth watching. Always been fascinated by these systems,look forward to the engineer giving the boiler its annual service.

  • @scottreger4266
    @scottreger4266 2 роки тому +1

    Thanks Allen for sharing your professional experiences in this video, managed to pluck up the courage to tackle the plate heat exchanger on my vitodens 100, got to say being a competent person you made this job basic enough for me, saved me money and got my boiler back up and running!! Showing you channel support and thanks very much well put together video...

  • @gimbalair
    @gimbalair 4 роки тому +3

    I have this boiler, this video has been a real eye opener. I had issues with my plate heater fouling up, the installer blamed the rubber pipes, a known issue by all accounts, he cleaned it out and performance was much better. I have since had the boiler serviced regularly by a different company and they do not carry it out as thoroughly as this. I’ll be showing them this video.
    I came here as I wanted to learn how to wire a Nest thermostat, which until I get the boiler serviced is pointless installing.
    I’m not gas safe so won’t be undertaking any of this myself, even though it looked straight forward.

    • @AllenHart999
      @AllenHart999  4 роки тому

      If the system is clean then they do not normally sludged up. 👍

  • @clarkestephen8299
    @clarkestephen8299 2 роки тому

    Thanks for videos. Saved me a lot of work and money. Went straight to the fault. Heat exchanger out. Cleaned, de scaled, re fitted. 3 hours later. Hot water again.

  • @1ramus1
    @1ramus1 2 місяці тому

    Thank You Allen. Very useful information for future. I have been using the same boiler for four months and have had no problems yet.

  • @mattkaramccarthy677
    @mattkaramccarthy677 5 років тому

    Nice to see service technicians actually using the Viessmann cleaning tool and the service kit!

    • @olek735
      @olek735 3 роки тому

      I doubt a bit of this shovel is really useful. He didn't use it. If use this wouldn't have such a nice new look. I use plastic to clean the main exchanger lot safer. ;)

  • @jonohutton89
    @jonohutton89 4 роки тому

    Just had this problem on my boiler. It's heating to 102 but water is Luke warm then cuts out with f2 error code. Thanks to this video and others I have narrowed it down to diverter valve or heat exchanger. Saved me bundle! Thanks

  • @phasedout6769
    @phasedout6769 5 років тому +4

    great video, very informative. I'd like to see more along this format. Fault finding, diagnosis and service. 👍

  • @simonehawksworth8924
    @simonehawksworth8924 4 роки тому +1

    Another really useful video, Thankyou Allen for all your hard work on these.

  • @robertdonaghy7260
    @robertdonaghy7260 5 років тому +1

    Cheers Allan, i enjoyed that. Decent of you to take the time to make these Videos.

  • @ArifPolicewala
    @ArifPolicewala 9 місяців тому +1

    Thank you Allen. That was a straight forward precise video❤

    • @AllenHart999
      @AllenHart999  9 місяців тому

      Thanks very much for your comment, please consider subscribing to support the channel 🙂

  • @Randommusingsvideos
    @Randommusingsvideos 5 років тому +1

    Interesting video; if that boiler was removed for the hot water fault then it goes to show the value in getting a heating engineer to take a look at it (And get the boiler serviced annually too!) Viesmann boilers a really good as they have a stainless steel inox heat exchanger, so should last a while longer than boilers with the cheaper aluminium heat exchangers. Once again Alan, a great informative video!

    • @AllenHart999
      @AllenHart999  5 років тому

      Thank you

    • @SalimKhan-gk1fh
      @SalimKhan-gk1fh 5 років тому +1

      Random musings , An interesting video to watch, but the thought in the back your mind is was this boiler removed just because of the hot water fault? so whole new boiler installation for such a small fault ?? unbelievable!

    • @AllenHart999
      @AllenHart999  5 років тому

      Salim Khan I am guessing that would be the case but not sure

  • @ICGedye
    @ICGedye 4 роки тому

    Awesome, should help my 'I only fit Worcester' gas fitter no end. Thanks, and keep up the excellent service!

  • @dunlaoghaire1000
    @dunlaoghaire1000 4 роки тому

    How great is it, that you have all those sample boilers! Great videos you made. Thanks a lot.

  • @James-m8b5d
    @James-m8b5d 11 місяців тому

    Had loads of these year mostly with 050. Some I've managed to clean others I have just straight up replaced just to save a return visit. 050 has very small fins so much hard I have found to clean. Good video l, and great pro

  • @heatpump8566
    @heatpump8566 5 років тому +1

    Excellent job as usual Allan. Thorough 👍

  • @RajeshBangera-x8i
    @RajeshBangera-x8i Рік тому

    Thanks Allen. It was really helpful as I was going to do a service soon on this boiler and has the same problem. Cheers

  • @konradbidwell8363
    @konradbidwell8363 5 років тому

    Alan top draw mate I had a customer call me today with exact boiler describing same issues so did a little google and happy to see this come up. Obviously I shall diagnose properly when I go tomorrow but I’m sure this vlog will be of use👍🏻👍🏻

  • @danielwilliams3978
    @danielwilliams3978 3 роки тому

    Nice Job Allan, looks like you fixed it.

  • @gerardlong5675
    @gerardlong5675 5 років тому +2

    Nice video showing how it should be done Allen.
    When I’m changing the plate heat exchanger I normally crack open the cold water inlet nut to let air in when the hot tap is open to let some more water out so less mopping up 👍obviously can only do this if your tap is lower than the boiler 😆
    Love the videos keep them coming 👍

  • @rocketman246
    @rocketman246 5 років тому +1

    Excellent video mate. I did the same with a Worcester but only lasted temporary so had to change ultimately with a new Hex

    • @AllenHart999
      @AllenHart999  5 років тому

      I had one on a viessmann a while back that lasted 5 mins, i had to take heat exchanger out and flush it all. Thanks.

  • @larry2569
    @larry2569 5 років тому +1

    Thanks Alan for all your help

  • @imrancankaya4831
    @imrancankaya4831 7 місяців тому

    Thank you, that is amazing teaching, step by step ❤

  • @stewben1169
    @stewben1169 5 років тому +2

    Excellent video very in-depth and very informative. Thank You

  • @SalimKhan-gk1fh
    @SalimKhan-gk1fh 5 років тому +2

    Another excellent video Allen ! Thanks for uploading it I’ve fitted quite a few viessmann’s and also maintain quite a few you’ll be surprised how many I’ve ‘brought back from the dead ‘! which have been condemned, all due to lack of proper servicing many had still got the factory paint on the Schraeder valveOn expansion vessel where they have never been unscrewed or been topped up! I think it’s a state of the industry at the moment to be honest, I may be wrong? Whilst the burner assembly is out you also need to clean and check the gaps of the spark electrodes and after refitting the burner assembly the condensate trap will need to be washed out. this particular boiler you are servicing Has suffered neglect and has been ran on a dirty system, The dirt and debris in the Heat exchanger coils has caused the boiler to partially fill up with condensate water
    I’ve seen it many times before through lack of servicing or proper servicing, shall we say?
    if maintained and serviced well these are a very good boiler giving great reliable service and excellent efficiency

  • @davidgorrie7606
    @davidgorrie7606 3 роки тому

    great work allen , your mind must be on ob all the time , your knowledge on practical theory maintenance service worl and breakdown are 2nd to none , brilliant to watch , what do you do in your spare time allen ? ha ha ha i was an lpg fitter engineer , for calor gas covered whole of scotland . great job , doing commercial work industrial domestic and caravan sites covered everything , watching your self takes me back to my days when you just got on with job , in a hundred life time i couldnt have had a more satisfying job and experience over years no one can replace it , brilliant to watch your vids allen keep up great work 1st thing i do when i have a cuppa and shower in morning is put your vids on , im a dedicated fan brilliant mate ,

  • @gasways986
    @gasways986 5 років тому +2

    Hi Allen very informative video, what chemical do you use to clean the plate FX2?

  • @rajeshbangera6149
    @rajeshbangera6149 Рік тому

    Thank you Allen. As always great video and explained well. Cheers

  • @gjmheating8857
    @gjmheating8857 2 роки тому

    Nice Allen I do same thing with heat exchanger but use white vinegar whilst having chin wag. If the boiler is on ground floor can you still drain through filling loop? Also I recommision vessels in situ helps with draining etc. I had one last week refilled it to 1 bar shot up so quickly and when heating was on it was so High but there wasn't actually any water inside boiler when I drained it I checked usual hose on expansion vessel but couldn't find blockage etc.

  • @brucecarter6541
    @brucecarter6541 3 роки тому +1

    Thanks Allen love your vids,you have found my problem with boiler, 👍👍👍

  • @abdulh63
    @abdulh63 5 років тому +1

    Love the video! Very well explained and easy to understand

  • @kayleighbeuzelin
    @kayleighbeuzelin 4 роки тому +1

    Very good and educational. Thanks for your time

  • @sodig876
    @sodig876 5 років тому +1

    Very informative video Allen 👍 keep up the good work.

  • @jasonporteous9722
    @jasonporteous9722 Рік тому +2

    Hi Allen
    What is the name of the chemicals you use to de-scale

    • @AllenHart999
      @AllenHart999  Рік тому +1

      i normally use one shot but its not really advised anymore.

  • @lukemitchell6146
    @lukemitchell6146 4 роки тому +2

    Love the video, I'm working on one tomorrow with more knowledge now, thanks Allen!

  • @danielwilliams3978
    @danielwilliams3978 3 роки тому

    Informative Video Allan, thank you for making it.

  • @lloydbargery7339
    @lloydbargery7339 3 роки тому

    Brilliant video allen

  • @paulrossiter9567
    @paulrossiter9567 4 роки тому

    Very useful video ....this along with most of your others has gone straight into my saved vids ⭐️⭐️⭐️⭐️⭐️
    You are the guru 🧙‍♂️

  • @aksentyalagoz6061
    @aksentyalagoz6061 2 роки тому

    thank you for the very informative video where in alberta canada can a oerson get parts

  • @stewartnorton6386
    @stewartnorton6386 3 роки тому

    Great video. My stopped working yesterday display showing 99 degrees no hot water or heating and the burner symbol doesn't come on, any ideas what that may be ?

  • @damiebgibbons5710
    @damiebgibbons5710 Рік тому

    Hi Alan, just a question, if there is no flame when the hot water is on , is it still the heat exchanger, there is heating just no hot water and the three port vale is moving in and out when you turn on the hot tap, hope you can answer the question for me cheers

  • @patrickahearne8770
    @patrickahearne8770 5 років тому +2

    Another great video Allen, however I have a question about servicing.
    Would you recommend that servicing it is done based on time, ie once a year, or by usage? My Viesmann 100 is a couple of years old but It doesn't get a massive amount of use. I'm a single bloke living on my own, out working six days a week so not caning it like say a family of 4 running baths and showers and having the heating on all day long.
    All the plant items where work get serviced based on how many hours usage rather than an arbitrary once a year.

    • @AllenHart999
      @AllenHart999  5 років тому +1

      Patrick Ahearne Manufactures recommendation is once a year 👍

  • @charliewillis8527
    @charliewillis8527 4 роки тому

    Does the door seal need to be replaced every time it comes apart and does it need to come apart ever year as the Worcester boilers only come apart when they fail the pressure test but a change the red burner seal every 4 years i only work mainly on the Worcester boilers as thats what i install and repair which keeps me more than busy with all my other jobs

  • @sirazsaleh5942
    @sirazsaleh5942 5 років тому +2

    Hi Alan,
    Which cleaner chemical did you use to clean the hot water plate heat exchanger . I have a similar symptoms on my potterton Promax 28He I do get hot water, but sometimes for about 10 seconds water gets cooler and then it gets hot again, this happens now and again, not always. I would say intermittent not always. I suspected heat exchanger may be partial blocked or the boiler may be operating like this from new. The boilers is 3 years old.

    • @AllenHart999
      @AllenHart999  5 років тому

      A lot of people use one shot.

    • @MohammedAli-rh5ii
      @MohammedAli-rh5ii 3 роки тому +1

      @@AllenHart999 hi Alan ur video are amazing just i just bought a new property my heating work ok but my hot water warm for a bit and then goes to cold can u pls tall me what problem that might be. .thank you very much

    • @rayc1503
      @rayc1503 3 роки тому

      @@MohammedAli-rh5ii NTC sensor, pcb, flame sensing electrodes. Blocked plate to plate. It's best to call in a gas safe engineer. It's hard to diagnose without being there.

  • @MikeAnderson-si2xe
    @MikeAnderson-si2xe 7 місяців тому

    my dad worked for viessmann for 8 years and had the tools but where is the screwdriver from

  • @madmaycon2531
    @madmaycon2531 7 місяців тому

    Thanks a lot Allen, Perfect video !!!!

  • @albert5538
    @albert5538 Рік тому

    Hello Allen, I am in a similar situation. When I turn on the hot water, it doesn't come out very hot. When the boiler reaches 60 degrees, it stops and does not turn on again until it reaches 25 degrees. The dial is at number 6. I have cleaned the exchanger, I have also cleaned the coil and finally checked and set the expansion vessel to 1 bar. Do you have any idea what it could be? I suspect that the sensor that measures the temperature is measuring more temperature than the real one.

  • @paulclive3626
    @paulclive3626 5 років тому +1

    Superb informative video as always, well done & thankyou

  • @crazygeorgelincoln
    @crazygeorgelincoln 5 років тому +3

    Interesting insight into the dark art of boiler servicing.
    I hope the original owner wanted a new boiler ,and not the other option.
    Slightly baffled by the air bleed being on the inside and the top up on the outside. I knew of a boiler that kept being topped up then it died of multiple component failure.

    • @AllenHart999
      @AllenHart999  5 років тому +1

      I do not know anything about the old owner or why it was replaced. Maybe they changed it as they were having issues with the hot water. Not really sure. Thanks.

    • @jamesjulian
      @jamesjulian 5 років тому

      Allen Hart why would you have a boiler on your wall with no idea of its history?

    • @nomore5668
      @nomore5668 5 років тому

      @@jamesjulian Because it's not on his wall, it's on a customer's wall.

    • @SalimKhan-gk1fh
      @SalimKhan-gk1fh 4 роки тому

      no more It’s not on his wall it’s on the wall of his man cave these are boilers just to practice on and demonstrate to us

  • @josephclark48
    @josephclark48 5 років тому

    Hi Alan. What is the problem if pressure guage drops down when boiler is running and does not increase above the standing pressure? Great videos.

  • @MattPasek
    @MattPasek 5 років тому +1

    Like always top class video ..very interesting and helpful will definitely help when going for my gas training ..
    Any advice.or tips best way to complete the training ..
    Thanks

    • @AllenHart999
      @AllenHart999  5 років тому +1

      mateusz Pasek Try and spend as much time as possible working with an engineer. 👍

  • @vitallife14
    @vitallife14 4 роки тому +2

    Love your videos Alan keep up the good work!
    My 30kw vitodens 100 has just developed this fault, its 1st fault after 6 years!
    My gas engineer just changed the plate heat exchanger for new but since the replacement my hot water flow rate has reduced noticeably at all my outlets. I checked all the service valves and stop tap and everything is fully open. I’m having small problem getting him back due to lockdown shielding.Just wondered is it possible that he’s reduced the flow rate on the boiler somewhere of is it possible that the plate heat exchanger has been fitted wrong,in terms of the wrong way around or up side down? Interested to know your thoughts. All the best

    • @rayc1503
      @rayc1503 3 роки тому

      Possibly a smaller plate to plate heat exchanger was fitted.

  • @mariom383
    @mariom383 4 роки тому

    What should I check?
    My unit gets the house up to temperature and it doesn’t come back on.
    So I turn it off and put it back on and it does the same thing again.
    Any idea please let me know thank you

  • @davidgorrie7606
    @davidgorrie7606 3 роки тому

    foegot to add your instals are great to, a major factor is eying up prior to taking job on every detail hidden work and a lot of the time say on phone for a breakdown customer they tell youthe faults and on your drive to job u can save time by going to check main obvious faults right away althoughof course there has to be a full inspect repair and recommission of system , look forward to seeing more , i can subscribe if you send me details allen , thank you for making a great start to my day again mate ,

  • @jasonnewportcounty9897
    @jasonnewportcounty9897 2 роки тому

    Hi Alan what cleaner did you put in the heat exchange unit
    Cheers

  • @ebru9830
    @ebru9830 4 роки тому

    When I use the kitchen tap while the hot and cold water is running, the water would turn freezing cold. When I shut the cold water and only the hot water is open it would still be freezing cold for like a minute or so then it would go back to normal but the same thing would happen over and over again. Can you tell me why this is happening and what I could do about it please?

  • @markfung6418
    @markfung6418 5 років тому

    Hi Allen, thanks for putting up informative videos!
    I had a Vitodens 100 WB1A installed 10 years ago. Overall I'm happy with it. The first heating company didn't install low loss header. This reduces efficiency I was told by current authorized rep. It is cleaned and maintained yearly. However, the boiler locked out reporting F3 code a number of times. Technician determined that spark generator needed replacement. Boiler worked well for two years afterwards. Now the boiler puts out F3 code again. After last maintenance visit, the fan (or something) made loud humming noise during startup. The noise reduced once the boiler was full on. Everything was working fine otherwise. Had the technician back. He heard it too but couldn't determine the cause. I didn't want him to just replace whatever (motor or fan) making that noise.
    Allen you know these boilers well. I would like to get your feedback on some items. 1/. How durable are these boilers? 2/. How often spark generator needs replacement? 3/. Love to have a hot water combi version but I'm worried about having issues without hot water and heat. How reliable is the combi type? 3/. My boiler is 10 years old. Should I continue to have it serviced or have it replaced?
    Would greatly appreciate your opinion.
    Thanks.
    Mark.

  • @owsi2297
    @owsi2297 5 років тому +2

    Cheers mate that was a really interesting video 👍

  • @anthonyclinton1355
    @anthonyclinton1355 3 роки тому +1

    Hiya Alan, does this boiler have a drain off point if you don't have a magnetic filter to drain from, I'm gas safe registered but never worked on this boiler b4?? Thanks bud 👍

    • @AllenHart999
      @AllenHart999  3 роки тому +2

      Yes you use the filling loop. Thanks.

  • @umark6695
    @umark6695 5 років тому +1

    Hi Allen. Good video as usual. Where did you get that short probe for the Kane mate?

  • @timjohn7483
    @timjohn7483 2 роки тому

    Thank you very much very helpful keep up the good work

  • @WEYHARRY1
    @WEYHARRY1 5 років тому +1

    Good video Allan

  • @charliewillis8527
    @charliewillis8527 4 роки тому

    Allen can you show how the condence trap comes out to clean

  • @keitho77
    @keitho77 5 років тому +1

    Thanks for the video Alan. Very interesting to see how it all works.
    How would you go about fixing a boiler that the flow of water in is too fast, causing a no hot water issue in a shower?

    • @AllenHart999
      @AllenHart999  5 років тому +1

      Set the boiler up correctly. Reduce the flow to match the boiler. Thanks

  • @philgreen3376
    @philgreen3376 3 роки тому

    Just found your videos, great information Thanks👍

  • @fraserholmes2442
    @fraserholmes2442 4 роки тому

    Hi Allen- ive got a Viessmann V100 WB1C 35kw that needs the pump replacing. Does the whole system have to be drained down to replace a pump, or are there isolating valves? Cheers

  • @misfortune5007
    @misfortune5007 2 роки тому

    Can you tell me what resistance I should expect from the seson next to the burner bleeder? Its a high thermostat. It has the 47 numer on the wire plug.

  • @jamesdcuk
    @jamesdcuk 5 років тому +3

    Very interesting to see how it all works (and how it breaks). I wish that I was gas safe so that I could have a tinker!

    • @olek735
      @olek735 3 роки тому

      What's is a "tinker"?

    • @jamesdcuk
      @jamesdcuk 3 роки тому

      @@olek735 Sorry, I should have been clearer and avoided the colloquialism. To "tinker" to me means to work with or on some device or machinery. Here in the UK you need to be qualified to work on boilers, and I am not!

  • @scottvincent1810
    @scottvincent1810 5 років тому

    I have this boiler. I have a leak from condensing trap. Can you do a video on condensing trap removal please?

  • @imranpatel2489
    @imranpatel2489 4 роки тому

    Top vid Allen. Quick question about the expansion thank where you pressurised it. For it to work properly does it need to be pressurised like you did? If so what happens if its not pressurised? Thanks

    • @dan123collins
      @dan123collins 3 роки тому +1

      Yes it needs to be pumped up to the correct pressure ( normally 1bar ish ) if it’s not pressurised fairly regularly it will naturally lose pressure and if it loses enough pressure then as the boiler operates the water has no where to expand into and the boiler PRV ( pressure relief valve ) will dump some water, the problem is when the system cools down its now lost some water and needs topping up, this cycle of dumping water and needing topping up continues until the expansion vessel is re-pressurised ( or its failed internally )

  • @wackadakka3134
    @wackadakka3134 2 роки тому

    I have the veissman 050 , the hot water flow is very slow , but its constant temperature , . no one can seem to figure out whats happening ! ..any ideas ?

  • @richardbutler6985
    @richardbutler6985 2 роки тому

    Question sir should the boiler temperature drop when hot water or heating isn't being used? Or should the boiler keep reheating to the set temperature e.g. 65c if set there ?

  • @456Brian
    @456Brian 5 років тому +2

    Hi Alan what boiler would you recommend . I have 9 rads the one I have is a ideal classic we've had it 20 years .it is a conventional boiler thanks

    • @AllenHart999
      @AllenHart999  5 років тому +2

      brian jones Baxi Platinum is a great choice or the Viessmann 100, Thanks

    • @456Brian
      @456Brian 5 років тому +2

      Thanks Alan all the best

    • @SalimKhan-gk1fh
      @SalimKhan-gk1fh 5 років тому +1

      brian jones , get the Viessmann vitodens 100 it’s a great boiler, I recommended one to my neighbour last year & he was really impressed with how quiet it was ,& how quick it warms up all the rads, but best off all its extremely gas efficient !

    • @456Brian
      @456Brian 5 років тому +1

      @@SalimKhan-gk1fh thanks you for your advice

    • @SalimKhan-gk1fh
      @SalimKhan-gk1fh 5 років тому +2

      brian jones , your welcome Brian, just ensure u use somebody who is familiar with whatever brand of boiler you choose and also any subsequent servicing is carried out to Allen harts thoroughly high standard! I must be on my 20th viessmann boiler fitted so far
      I only had to call them out once & the engineer was brilliant and found the issue very quickly, which was an installer issue!
      This boiler Allen is working on has been mistakenly written off and replaced due to it only needing a thoroughly good clean!
      I see this situation quite often now

  • @danielkrawczyk4
    @danielkrawczyk4 3 роки тому

    Copper press on the gas pipe. I wonder if they will ever allow that here in the States! Great video Sir. What would you call that heat exchanger tool?

  • @Bikebros27
    @Bikebros27 Рік тому

    I’ve got 1 that’s doing the same boiler keep cutting out and temps are getting up to 82

  • @rayc1503
    @rayc1503 5 років тому +2

    Hi Allen could you put up a link to the cake slice holder you cleaned the primary he-ex with? 😊

    • @AllenHart999
      @AllenHart999  5 років тому +1

      ghostmanromeo uk I got it from my Viessmann rep. Not sure who sells them. Sorry

    • @slickydee5507
      @slickydee5507 5 років тому +2

      @@AllenHart999 Viessmann sells them. I'm a US wholesaler we buy the exact same ones from Viessmann

  • @darrenappel9281
    @darrenappel9281 5 років тому +1

    Hi Allen
    great video
    where did you get that heat exchanger cleaning blade?

    • @AllenHart999
      @AllenHart999  5 років тому

      Darren Elaouad Viessmann rep. Thanks

  • @bilalchanna4699
    @bilalchanna4699 4 роки тому

    Thank you for detailed explanation

  • @Perkinatortwins
    @Perkinatortwins 3 роки тому

    This video is brilliant Allen.... I have this exact problem, but could you answer this... My problem is the bathroom taps not getting hot but the baffling thing is the downstairs are red hot??? I can see it cutting off when I run the bath and sink taps as in your video but run the hot kitchen tap and it’s blistering hot and doesn’t cut off??? What’s your thoughts?? Thanks in advanced

    • @AllenHart999
      @AllenHart999  3 роки тому +1

      Maybe the boiler hasn’t been set up correctly or the boiler is quite small for the flow rate? Hard to say without seeing it. Thanks.

    • @Perkinatortwins
      @Perkinatortwins 3 роки тому +1

      @@AllenHart999 thanks for replying Allen....I’m in Leicester, do any of your team work down this way? Thanks

    • @AllenHart999
      @AllenHart999  3 роки тому

      Tom Perkins Unfortunately not sorry

  • @olek735
    @olek735 3 роки тому

    What is the main reason for second exchanger being so "dirty"?

  • @alisonmcrory
    @alisonmcrory 9 місяців тому

    Viesmann bar us at 1 when I switch it on it goes up to 3 bar how do I de pressurise it

  • @markcliff9923
    @markcliff9923 4 роки тому +1

    Great video Allen, got to do a plate heat ex on the 100-w 25kw combi, is it the same? Don't usually do much on the viesmanns, parts really expensive, I am gas safe by the way👍

  • @richardwallinger1683
    @richardwallinger1683 5 років тому +1

    super advice and diagnostics ..

    • @AllenHart999
      @AllenHart999  5 років тому

      Thank you for taking the time to watch my video.

  • @Nick_G7IZR
    @Nick_G7IZR 5 років тому

    I have the same problem with mine, getting to 88'c then cutting out. I understood the heat exchanger and cleaning the combustion chamber etc, but what on earth was that thing you pressurised and would I need to do that and if so, with what adapter? Thanks!

  • @Ro55stw
    @Ro55stw 5 років тому +1

    Good video mate

  • @jackhoskins722
    @jackhoskins722 5 років тому +1

    Could you put details of that heat exchanger tool in the description please mate !

    • @AllenHart999
      @AllenHart999  5 років тому

      I got it from my rep.

    • @Moocow9991703
      @Moocow9991703 5 років тому

      @@AllenHart999 Thanks Allen I've been a worcester installer for about 10 years but recently I've found out that they are a large share holder of boxt so my loyalty as completely gone and I'm not keen on the idea of promoting worcester anymore....i was thinking of switching over to viessmann instead, do you think that would be a good move for my business? Many thanks Dan.

  • @petersutton3054
    @petersutton3054 5 років тому +2

    Hi Allen have you came across the F4 fault on these boilers

    • @AllenHart999
      @AllenHart999  5 років тому

      Peter sutton Yes, normally needs a strip down service, it could also be other things as well, blocked condensate, lack of flame. Electrodes etc etc

    • @AllenHart999
      @AllenHart999  5 років тому

      I have done this video. Hope that helps. ua-cam.com/video/va2n9UWW_QA/v-deo.html

  • @newsbiz
    @newsbiz 5 років тому

    Hello, I had F4 fault (condensate), Wiessman manual says refractory must be dried out with a hair dryer - how do you do that?

  • @allthingsmf8008
    @allthingsmf8008 Рік тому

    great video, thanks

  • @paulmcgeoch2603
    @paulmcgeoch2603 5 років тому +1

    Is this your own boiler Allen or is it a customers? Good video 👍🏼

    • @AllenHart999
      @AllenHart999  5 років тому

      Paul Mcgeoch It’s my boiler now. Thanks

    • @olek735
      @olek735 3 роки тому

      After this service Allen was to buy this boiler. Lol.

  • @rolandsmith2141
    @rolandsmith2141 5 років тому +1

    Disconnecting the condensate pipe from bottom of heat exchanger when flushing out the debris (put a vessel under it obviously) would be a good trick .......ah Allan.

    • @AllenHart999
      @AllenHart999  5 років тому +1

      You could do it that way but i would rather do it with hose connected. then clean trap out at the end if needed.

  • @MrVictorvolvo
    @MrVictorvolvo 3 роки тому

    Would anyone know what size hose is being used, which is attached to the bleed valve to clean the heat exchanger?

  • @philipross7909
    @philipross7909 4 роки тому

    Hello Alan
    I have just had a 111w fitted
    The boiler works all ok
    However when the burner turns off the boiler temperature display rises by up to 10c above the set point
    After a while it reduces
    The ch is set to 70c and water to 60c
    Any ideas ?

  • @ML-lg4ky
    @ML-lg4ky 5 років тому +2

    I wish viessmann had a dealer network here in Upstate NY

    • @AllenHart999
      @AllenHart999  5 років тому

      What boilers do you have over the pond?

    • @ML-lg4ky
      @ML-lg4ky 5 років тому

      Allen Hart Weil Mclain, peerless, lochinvar, HTP, Utica, mostly cast Iron units still in use. I installed a Buderus G115 with a riello burner last year and absolutely love it. Most homes have forced Air here but some have hot water baseboard with requires 180f degree water. Many people here that install High efficiency boilers are very unhappy because the do not see any gas savings because they don’t have the proper heat emitters. Am going to install an radiant slab in my new garage so I’m looking for the proper boiler for that. Keep up the good work Allen.

  • @matskieden511
    @matskieden511 3 роки тому

    Brilliant. Very informative.

  • @bugz7149
    @bugz7149 4 роки тому

    Wher did you find the nameplate?