This type of Mastercool works better with this type media and cools very good too. Take care of them and they will last a long time. It does help to open a window or two also.
This is the clearest explanation. I should have watched this before calling someone. Question: how do I fix a noisy motor. It's so loud all night long that I can barely sleep.
Aye thanks for being clear on how things get done man I was able to get my great grama’s swamp cooler going for her on these hot desert days! I’ll definitely keep checking out your channel 😊
That was the best informative video I've seen on our swamp cooler pads we have to punch them down a little bit on the top so that the tube will fit in and I'm wondering on the tray where the pads sit how far should the water be below the bottom of the cooler pads or the top of the tray where they sit I'm not sure which thank you
Yes, they are! I live back in AZ, but I did live in Colorado for 6 yrs, and that is all you really need there for cooling. Same for Utah, where I've also lived and have lots of family there that have evap coolers
In outback Australia we use these evaporative aircons alot. Ours look different with the wood pads. We use a netted wood shave that looks like a pillow. One thing my unit had was a small water discharge hose that was around 30 metres long that drained when the water pump was running. It prevented any hard buildup inside the cooler and watered trees in our yard. Had it around 10 years and never had any calcium or scale inside.
Thank you so much for this video! I've got the same exact cooler on my roof. My landlords haven't been over here since before the pandemic ever started so I pretty much do it all myself. Problem is I completely forgot to go up and put the winterized cover on the cooler this last winter and when I went up there to get the cooler up and running the other day the big blower isn't working so there's no air. I'm assuming it needs to be oiled and was already assuming that and went up there last night to oil everywhere I could and couldn't figure out how to get the blower side of the cooler open in order to reach it even though I know I have accessed that side before. Now after seeing u lift that 1st panel off the blower side I feel stupid 🤦♀️ lol. In my own defense though I was up there in the dark so that's probably why I wasnt able to see that it came off like that lol. Anyway , after watching you video I can see Ive got alot more work to do up there. Wish me luck and thanks again lol.
Not difficult when you start with a unit well-cared for and easy to prep. Most homeowners neglect their evaporative coolers. Have worked on several hundred, and the only units as clean as the one you showed were basically new.
Good video I use shop vac to clean water pan after scraping loose all dirt / crap. Water distribution tube -remove cap at end , tap w/ screw driver to loose deposits and take sharp point to unclog/clean holes. Leaf blower to clean pads of dirt. Dont forget the corrct way to position pads back in. Oil bearings again.
you forgot to mention that the media pads face a certain way. the painted stripe faces you and is closer to the bottom of the cooler. it appears you installed them correctly, which is good.
swamp coolers we developed that technology in Iran 1912 they work good in the desert 15% humidity not in Florida but you can when I'm in Florida 95 degree day in a garage to cool off when working on car this is how they work water is sprayed on the elements as the water evaporates it cools the air coming through it but also raise the humidity in one sense of the word you could call it a humidifier water-cooled Chillers have huge cooling towers and and they are Monster swamp coolers as water evaporates it cools the water do water goes into the condenser Barrel cool the freon vapor to a liquid state TMI LOL
Distribution ductwork from the cooler, and exhaust ductwork with a central exhaust fan sucking out the warm air, should at least help with the problem at 6:30.
Evaporative Cooling is different. Direct cooling as in video adding moisture to the air. Indirect cooling from industry leaders with Wet bulb temperature. Dew-point regenerative indirect evaporative cooling from Maisotsenko Cycle.
are these worth it in your opinion on really hot days 100 degrees also if 1 hp motor would be better than the standard 3/4 hp motor? in terms of more cooling
Is there a video for adjusting if water goes in the cooler or not. My swamp cooler's water is connected by my hose. And i'm sure i turn the water of so my cooler is just pushing hot air. .
No cost if you do it yourself, unless you decide to buy a new filter. If you hire a plumber, the last plumber I hired to do work inside the house was $125 per hour.
I think if I had this and the AC unit on that it probably wouldn't work the AC unit so hard. it's like having two AC units but one with less power. takes forever for the central air unit to cool the house. especially on super hot days. replaced the motor and upgraded the fan and cleaned the whole unit. blows super cold but house stays hot until night
There are holes on top of a pvc pipe that spray up into the hood and they plug with minerals and have to be cleaned out with a drill bit or properly sized punch.
my water distribution tubes are filled with what feels to be sand and it's not allowing to wet the pads so it's just warm air coming out of the vents.. how do I clean them out?
You could try pulling the hoses off one at a time and flushing them out. Also check the slits at the top of the panels and make sure they're not plugged. You should be able to run the pump only setting to saturate the pads.
@@Iscaper Thank you. We converted it to an AeroCool so we don't have a pump option anymore. I did disconnect and clean one tube, but the other is connected in the drain pan but to nothing on the other end. is that right? sorry, new to doing this myself! :)
@@c.jongho_luvr I've never heard of a swamp cooler without a pump. How else would you get water to the top of the pads? The cooler in the video is an Aerocool and it has a pump. Here's a link to a video by Aerocool, notice it has pump. ua-cam.com/video/eTR-7pMf1uM/v-deo.html
I believe I have the same cooler, it had the same decal and looks the same. How do I know what pads replacement to buy? I bought some from home Depot but they are short in height. Can anyone help?
I'm considering changing out my four panel swamp cooler for one of these Mastercool models. I'm looking on the price of the replacement pads and had sticker shock. How many years do you get out of the pads? I have hard water and usually change them out every year. Thanks in advance..
Not sure how many years the single pad lasts. We only lived in this rental for a year, but the pad had been in for at least 2 or 3 years according to the landlord.
I just bought a wet section to my 16yr old Mastercool evap as the old one rusted too far to fix. $324. I see that aerocool has a plastic insert to the wet section. which means no rust out and possibly lots cheaper to replace/repair. I wonder as I can't find one for Mastercool but the same design.features. You know of any plastic inserts for the Mastercool with 8" pads. 42" wide and 17 inches deep. i'm 5 weeks out from a Phoenix summer.
The new wet section comes painted and sealed. My old old one with real hard water lasted 16 years. My problem was I got too old to really climb up on the roof and empty it at seasons end. and so the water would just sit and rust the unit. It pays not to be lazy. But on any new house that AREO cool sounds like the cats meow being plastic inserted. What I should do is produce a aftermarket plastic insert for the mastercool and sell it to people who don't want to pay the $300+ for a new wet side.
I'm in Phoenix too just rebuilt my 10 year old master cool 6500 down draft this year I hadn't run a bleed or drain pump for last 5 years build up was so bad had to use pool acid to clean the wet section I tossed the pads out they were hard as a rock. The pool acid was harsh but it got the job done wasn't as bad working with then I thought gloves and goggles all I needed. I was surprised wasn't even any rust under all that buildup I had even bought a can of rubberized paint I returned the pool acid cleaned so well the bottom looked new. There is a local evap cooler store here they sell a stainless Steel wet section comes with new pad, pump, and everything in wet section little high priced $600 I was about to get it but changed my mind after seeing how clean mine was. It's like new now replaced bearings, belt, pulley, and installed new electrical box and thermostat getting 78F in my house 111 today 8% humidity. I wired in a purge pump to my new electronic thermostat has a purge pump feature turns on 2 times a day. I plumbed the drain line so it drains into a 5 gallon bucket has a hose at the bottom goes on my lawn. When the season is over ill just remove the bucket I had it running onto my lawn but from the roof it makes a hole in the grass plus I like the option of letting it run into the rocks if I drain some cooler cleaner out. This video didn't see purge pump or bleed line he must get lot of build up that pad needs cleaning. I plan on running a bottle of cooler cleaner once a month keep the new pads really clean.
I've got a MasterCoolin Tucson and was wondering the same thing! Why don't they have plastic inserts. Mines about 13 years old and is just starting to rust on the sides
Hello great video, I just had my roof done and I had the four panel swam cooler but my friend gave me one just like your review,. it got install and it blows air too low, I was wondering where can I purchase the control panel you have in these video, I think I need it.. right now I only have an on/off switch.. I need for my cooler to blow more air than what is blowing please help.. thanks in advance
I know this is an old Video. But maybe I could get some advice. I have the exact same unit but its my understanding that those pads are close to $90 in my area. Can they be scrapped and cleaned and reused? Mine do have what looks like some calcium deposits but it's not rock hard. I can break them off with my hands. Again I ask. Can they be scrapped and re-used? Plz help
I would just get this swamp cooler removed and dumped in the bin..lol. Get a self clean unit,with auto weatherseal..Auto dumping. like a Brivis, Breezair,Bonaire,Braimar just to name a few Aussie Brands.
What do you mean steam? There is no steam associated with an evap cooler. Why do people get so perplexed about how an evap works? It's very simple. The pads get wet by the pump. The blower blows air through the wet pads through the house. That's it! It's the same concept if you lick your arm and blow on it. Very simple.
iScaper1 wow! My instincts are working, that's what I did, but then I turned it off after running for 10 mins. I didn't want to chance it until I could find out for sure, your vid was the best I did find though. Thanks for the quick response. I really thought I would have to call the property manager here at the condos, which can be problematic! I live in Santa Fe NM and the humidity yesterday got down to 5%, yep, five percent.
The hose is used so that you don't dump water onto the roof when you drain the unit, It is also used so that if there is an overflow, the water will not drain onto the roof.. It probably goes to a gutter or drain.
This is probably the clearest, most informative video on any type of home maintenance that I’ve ever seen. Thank you!
Wow, thanks!
Very easy to follow video. Thank you! Watching from Albuquerque NM. Where swamp coolers are on most homes.
Thanks for watching!
I never comment on this stuff, but I had to say that you made an exceptional video that was enjoyable and informative!
Awesome! Thank you!
Nicely done. Thank you for producing this video and explaining the steps clearly and succinctly.
Great video. Very well explained and easy to follow instructions. Thanks for posting it.
Thanks for watching!
Thank you from Albuquerque!!
Hello Albuquerque!
Agree with all the thank you comments. Very informative,direct and quick!
Thanks Jared for watching.
I have that same switch for the swamp cooler in my house and never knew what it was for! Thanks for video, I want to get mine started again!
This type of Mastercool works better with this type media and cools very good too. Take care of them and they will last a long time. It does help to open a window or two also.
Good info, thanks for posting.
This is the clearest explanation. I should have watched this before calling someone. Question: how do I fix a noisy motor. It's so loud all night long that I can barely sleep.
The only way I know how to fix a noisy motor is to replace it. I would double check that the belt or blower isn't partially responsible first.
Aye thanks for being clear on how things get done man I was able to get my great grama’s swamp cooler going for her on these hot desert days! I’ll definitely keep checking out your channel 😊
Thanks!!
Great video. So clear and skips nothing like most YT how-to videos.
thanks for taking the time to make this video, it was very helpful to me
Chris Copeland
Thanks Chris, I appreciate the feedback.
That was the best informative video I've seen on our swamp cooler pads we have to punch them down a little bit on the top so that the tube will fit in and I'm wondering on the tray where the pads sit how far should the water be below the bottom of the cooler pads or the top of the tray where they sit I'm not sure which thank you
Thanks for this. You pretty much put everything needed in this. Very well done.
One of the best videos explaining this.
Evaporative coolers are the way to go! Save much more money on utility bills than running an A/C all day. They're great to have here in Colorado.
Yes, they are! I live back in AZ, but I did live in Colorado for 6 yrs, and that is all you really need there for cooling. Same for Utah, where I've also lived and have lots of family there that have evap coolers
Great Job, a nice succinct, straightforward video.
In outback Australia we use these evaporative aircons alot. Ours look different with the wood pads. We use a netted wood shave that looks like a pillow. One thing my unit had was a small water discharge hose that was around 30 metres long that drained when the water pump was running. It prevented any hard buildup inside the cooler and watered trees in our yard. Had it around 10 years and never had any calcium or scale inside.
Good to know I’m interestid in these. Thanks I enjoyed it 👍
Thank you so much for this video! I've got the same exact cooler on my roof. My landlords haven't been over here since before the pandemic ever started so I pretty much do it all myself. Problem is I completely forgot to go up and put the winterized cover on the cooler this last winter and when I went up there to get the cooler up and running the other day the big blower isn't working so there's no air. I'm assuming it needs to be oiled and was already assuming that and went up there last night to oil everywhere I could and couldn't figure out how to get the blower side of the cooler open in order to reach it even though I know I have accessed that side before. Now after seeing u lift that 1st panel off the blower side I feel stupid 🤦♀️ lol. In my own defense though I was up there in the dark so that's probably why I wasnt able to see that it came off like that lol. Anyway , after watching you video I can see Ive got alot more work to do up there. Wish me luck and thanks again lol.
Good luck!
What is the I d size of the pump supply tube and the cell deck sprayer white tube for cleaning? (Nice clear video ) thank you .
I believe it's 3/8".
It will give you some relief from heat but not much
Very nicely done
Thanks Mike for watching.
Not difficult when you start with a unit well-cared for and easy to prep. Most homeowners neglect their evaporative coolers. Have worked on several hundred, and the only units as clean as the one you showed were basically new.
Good information, thanks for posting.
my granddaughter loves coolers
Thank you-- found it informative and organized
Must use descaling solution
Good video
I use shop vac to clean water pan after scraping loose all dirt / crap.
Water distribution tube -remove cap at end , tap w/ screw driver to loose deposits and take sharp point to unclog/clean holes.
Leaf blower to clean pads of dirt.
Dont forget the corrct way to position pads back in. Oil bearings again.
Great information, thanks for posting!
Thanks for the tip on cleaning out the water distribution pipe and its holes.
Thank you for posting this video.
Great video. I can now start up an easier way than I did in previous years.
Great video. Thanks.
You are welcome!
you forgot to mention that the media pads face a certain way. the painted stripe faces you and is closer to the bottom of the cooler. it appears you installed them correctly, which is good.
Thank you for taking the time to edit and post this video. Nice editing!
Thanks, I appreciate the feedback.
swamp coolers we developed that technology in Iran 1912 they work good in the desert 15% humidity not in Florida but you can when I'm in Florida 95 degree day in a garage to cool off when working on car this is how they work water is sprayed on the elements as the water evaporates it cools the air coming through it but also raise the humidity in one sense of the word you could call it a humidifier water-cooled Chillers have huge cooling towers and and they are Monster swamp coolers as water evaporates it cools the water do water goes into the condenser Barrel cool the freon vapor to a liquid state TMI LOL
well done ... however you maybe should have gone over the cleaning of the spray bar in the cooler pad hood but a very good job over all.
Thanks.
Thanks for this... very informative!
Glad it was helpful!
I have the same swamp cooler and I struggle to find these types of filters. The one I did find they had to custom cut and want like $150.
Distribution ductwork from the cooler, and exhaust ductwork with a central exhaust fan sucking out the warm air, should at least help with the problem at 6:30.
If you need to replace the pads what size pads does it use ?
As a experienced Aussie Swampy Scrubber try using a cobweb broom to clean the sump.
this is great, this looks just like my cooler
Great video! I have never had a swap cooler, I bought a house with a winterized unit. Your video had me up and running quickly. Thanks!
Sherri Burrell
Thanks Sherri, I'm glad the video was helpful.
Sir Thank You for your information another summer I checked it out again.
Evaporative Cooling is different. Direct cooling as in video adding moisture to the air. Indirect cooling from industry leaders with Wet bulb temperature. Dew-point regenerative indirect evaporative cooling from Maisotsenko Cycle.
Simple and easy, thanks! going to hook mine up to marrow..
Great video
Cooler at home haha!! Happy very good
are these worth it in your opinion on really hot days 100 degrees also if 1 hp motor would be better than the standard 3/4 hp motor? in terms of more cooling
Any cooling on a 100 degree day would be a help. A 3/4 hp motor should be adequate for most swamp coolers.
Do your swamp coolers not dump out the water after u switch them off cause here is Australia they do
Is there a video for adjusting if water goes in the cooler or not. My swamp cooler's water is connected by my hose. And i'm sure i turn the water of so my cooler is just pushing hot air.
.
Water in a swamp cooler sits in the bottom with a float valve that shuts the water off at a certain level. You could pull a panel off and check.
how much does it cost for a maintenance to get to cooler going ?
No cost if you do it yourself, unless you decide to buy a new filter. If you hire a plumber, the last plumber I hired to do work inside the house was $125 per hour.
I think if I had this and the AC unit on that it probably wouldn't work the AC unit so hard. it's like having two AC units but one with less power. takes forever for the central air unit to cool the house. especially on super hot days. replaced the motor and upgraded the fan and cleaned the whole unit. blows super cold but house stays hot until night
Great video , clean installation. Do you do the install as well ?
Sorry, I don't install swamp coolers.
Hi are the swamp cooler can have more then 2 vents on a house ?
I've never seen one with 2 vents, but I guess it's possible.
How do you clean out the water distributor if you’re not getting even Saturation on the pads?
There are holes on top of a pvc pipe that spray up into the hood and they plug with minerals and have to be cleaned out with a drill bit or properly sized punch.
What is the hp in these moter in blower
The motor I bought was 3/4hp.
Blower pully and moter pully size
my water distribution tubes are filled with what feels to be sand and it's not allowing to wet the pads so it's just warm air coming out of the vents.. how do I clean them out?
You could try pulling the hoses off one at a time and flushing them out. Also check the slits at the top of the panels and make sure they're not plugged. You should be able to run the pump only setting to saturate the pads.
@@Iscaper Thank you. We converted it to an AeroCool so we don't have a pump option anymore. I did disconnect and clean one tube, but the other is connected in the drain pan but to nothing on the other end. is that right? sorry, new to doing this myself! :)
@@c.jongho_luvr I've never heard of a swamp cooler without a pump. How else would you get water to the top of the pads? The cooler in the video is an Aerocool and it has a pump. Here's a link to a video by Aerocool, notice it has pump. ua-cam.com/video/eTR-7pMf1uM/v-deo.html
Are those pads supposed to be placed a certain way?
I think either side of the filter can be facing out.
How much does it cost, sir?
Hi, iscaper1. What did you use the pillow and insulation in the ceiling vent for?
In the winter it keeps cold air from coming in and warm air from escaping the house.
@@Iscaper I see
I just had a new mastercool installed
When I switch to put it on low it keeps running on high any recommendations?
Sounds like a wiring issue. The motor and switch have high and low terminals. Did the installer connect these correctly? I would give them a call.
@@Iscaper yes will do. Thank you for response 😊.
Very good video
kreepykoopa
Thanks for watching.
Awesome video good job
+Antonio Jasso de leon
Thanks Antonio for watching.
when you install the legs for the cooler do you have to find the studs or can you just screw it anywhere?
So you have to do this every day?
No, just in the spring when you first start up the cooler.
Thank you very useful video.
Brother thanks you for this good information
Very helpful. Thanks!
I believe I have the same cooler, it had the same decal and looks the same. How do I know what pads replacement to buy? I bought some from home Depot but they are short in height. Can anyone help?
You may need to measure the old pads to get the right replacements.
I'm considering changing out my four panel swamp cooler for one of these Mastercool models. I'm looking on the price of the replacement pads and had sticker shock. How many years do you get out of the pads? I have hard water and usually change them out every year. Thanks in advance..
Not sure how many years the single pad lasts. We only lived in this rental for a year, but the pad had been in for at least 2 or 3 years according to the landlord.
This is a great video, I have the same kind of cooler and am shutting it down. I can't figure out where the damper goes. Can you help? Thank you.
Usually the damper slides into a slot on the grill that is on the ceiling coming into the house.
when do you know when you need some new pads.
Need 1 for my suburban
🙂👍
I just bought a wet section to my 16yr old Mastercool evap as the old one rusted too far to fix. $324. I see that aerocool has a plastic insert to the wet section. which means no rust out and possibly lots cheaper to replace/repair. I wonder as I can't find one for Mastercool but the same design.features. You know of any plastic inserts for the Mastercool with 8" pads. 42" wide and 17 inches deep. i'm 5 weeks out from a Phoenix summer.
The new wet section comes painted and sealed. My old old one with real hard water lasted 16 years. My problem was I got too old to really climb up on the roof and empty it at seasons end. and so the water would just sit and rust the unit. It pays not to be lazy. But on any new house that AREO cool sounds like the cats meow being plastic inserted. What I should do is produce a aftermarket plastic insert for the mastercool and sell it to people who don't want to pay the $300+ for a new wet side.
I'm in Phoenix too just rebuilt my 10 year old master cool 6500 down draft this year I hadn't run a bleed or drain pump for last 5 years build up was so bad had to use pool acid to clean the wet section I tossed the pads out they were hard as a rock. The pool acid was harsh but it got the job done wasn't as bad working with then I thought gloves and goggles all I needed. I was surprised wasn't even any rust under all that buildup I had even bought a can of rubberized paint I returned the pool acid cleaned so well the bottom looked new. There is a local evap cooler store here they sell a stainless Steel wet section comes with new pad, pump, and everything in wet section little high priced $600 I was about to get it but changed my mind after seeing how clean mine was. It's like new now replaced bearings, belt, pulley, and installed new electrical box and thermostat getting 78F in my house 111 today 8% humidity. I wired in a purge pump to my new electronic thermostat has a purge pump feature turns on 2 times a day. I plumbed the drain line so it drains into a 5 gallon bucket has a hose at the bottom goes on my lawn. When the season is over ill just remove the bucket I had it running onto my lawn but from the roof it makes a hole in the grass plus I like the option of letting it run into the rocks if I drain some cooler cleaner out. This video didn't see purge pump or bleed line he must get lot of build up that pad needs cleaning. I plan on running a bottle of cooler cleaner once a month keep the new pads really clean.
I've got a MasterCoolin Tucson and was wondering the same thing! Why don't they have plastic inserts. Mines about 13 years old and is just starting to rust on the sides
You should just get a new unit completely new
I bought one last year for a client and I paid 700
I get discounts at noughtons
How much is power consumption & water....
Thank you for the informative video :)
Watt & price
Hello great video,
I just had my roof done and I had the four panel swam cooler but my friend gave me one just like your review,. it got install and it blows air too low, I was wondering where can I purchase the control panel you have in these video, I think I need it.. right now I only have an on/off switch.. I need for my cooler to blow more air than what is blowing please help.. thanks in advance
+Maria Daugherty
You can buy the control switches at Home Depot or Lowes.
Thanks I found it.
I know this is an old Video. But maybe I could get some advice. I have the exact same unit but its my understanding that those pads are close to $90 in my area. Can they be scrapped and cleaned and reused? Mine do have what looks like some calcium deposits but it's not rock hard. I can break them off with my hands. Again I ask. Can they be scrapped and re-used? Plz help
I've sprayed mine out. I think if you're careful not to tear the element a bit of scrapping won't hurt. It's worth a try.
@@Iscaper ok thank you so much
I put the whole freezer inside my swamp cooler,It worked very well and now I'm freezing to death inside my home.
Is there a front and back to the media or doesen't it matter?
Yes. There is an airflow arrow on the sides of the pads. Arrow points into the cooler.
I would just get this swamp cooler removed and dumped in the bin..lol.
Get a self clean unit,with auto weatherseal..Auto dumping.
like a Brivis, Breezair,Bonaire,Braimar just to name a few Aussie Brands.
I see only air-intake holes on the side. So all evaporated water (steam) goes inside together with air flow?
What do you mean steam? There is no steam associated with an evap cooler. Why do people get so perplexed about how an evap works? It's very simple. The pads get wet by the pump. The blower blows air through the wet pads through the house. That's it! It's the same concept if you lick your arm and blow on it. Very simple.
How much price.?
Thanks
Thanks Manny.
Dear can u explain if i have to install a single cooler for my entire home?
+Ali Raza
The type of cooler in the video is designed to cool the whole house. Crack windows in the rooms you want to draw cool air to.
+iScaper1 Thanks
my a/c unit brock do u thing i can connect this to the thermostat of the a/c unit so it can start by it self when it get to hot
No, I'm pretty sure it's different voltage running from a thermostat to the AC/furnace than from a control switch to a swamp cooler.
They do make a thermostat for evaporative coolers, in Australia they use them like centavo air with ducting.
I have one on my cooler so I don't freeze at 3 am
roberts459 ccç
No
I thought there were just one but i noticed the second blower i got me confused why there was two blowers
Sir, thank you very much.
Talented!
Cool video thanks!!!
+Tury Dexter
Thanks.
Price kya h
Thanks, very helpful
+Abel Mora
Thanks Abel.
How do you operate it? Do you turn on the pump for a while before turning to cool? I can't find anywhere how to ACTUALLY use it!
Turn the switch to Pump Only for 5 minutes to soak the pads, then turn the switch to low or high cool.
iScaper1 wow! My instincts are working, that's what I did, but then I turned it off after running for 10 mins. I didn't want to chance it until I could find out for sure, your vid was the best I did find though. Thanks for the quick response. I really thought I would have to call the property manager here at the condos, which can be problematic! I live in Santa Fe NM and the humidity yesterday got down to 5%, yep, five percent.
Do you have to keep windows open while operating?
@@ShaktiJ Yes, for two reasons. One, it will get humid in your house, and two, it will put a strain on the blower.
Very nice bro i have manifature this cooler please help me
I want to purchase plz send link
What's the hose hooked up to
The hose is used so that you don't dump water onto the roof when you drain the unit, It is also used so that if there is an overflow, the water will not drain onto the roof.. It probably goes to a gutter or drain.
These cooler means air cooler consume how many electricity.
This comment has death me
What is cost in Australian dollor