Wiring of Reverse Forward Motor Starter

Поділитися
Вставка
  • Опубліковано 16 кві 2018
  • This video demonstrates how to make "Reverse Forward Motor Starter". This video covers both power wiring and control wiring along with testing at the end of video using motor run status. We have used 3-phase supply from the VFD output set at low frequency so that motor rotates slowly to check the direction of rotation. Hope this video serves both tutorial value along with practical approach.
    We hope this video will be helpful to beginners, technicians and students who are new to automation and electrical systems.
    Subscribe us so that you don't miss any tutorial.
    Click below to know about "Battery Reconditioning 4 You"
    www.batteryreconditioning4you...
    Promoted by satyaraosiddhartha

КОМЕНТАРІ • 219

  • @arafatali1327
    @arafatali1327 4 роки тому

    U a one of my best lecturer's. Imple clear and precise. Wonderfully explained . Thumbs up

  • @saidkhalfan3785
    @saidkhalfan3785 4 роки тому +4

    Bro you are the best ever . thank you so much my brother .

  • @c-jaygabriel9874
    @c-jaygabriel9874 5 років тому +1

    These videos are very productive,they teach me alot as a technician/power engineer.

    • @starautomation
      @starautomation  5 років тому

      Thanks

    • @josefaschwanden1502
      @josefaschwanden1502 4 роки тому

      Id advise you rather to go to school than learning from this vid, already the first wire was faulty and a fire hazard.

  • @sly_fox8261
    @sly_fox8261 6 років тому +1

    Awesome Explanation man! Very easy to understand and thanks for the visual explanation

  • @alfredbuccobaki7485
    @alfredbuccobaki7485 5 років тому

    Simple and good explanation. Thanks my brother.

  • @eracismm
    @eracismm 3 роки тому

    L1 L2 L3 = Supply voltage T1 T2 T3 = Load side of Contactor At least in most parts of the U.S. Good explanation of why & how your wiring things up....

  • @christophersmith9013
    @christophersmith9013 2 роки тому

    Well taught bin trying to understand the rev/ frd for a long time thsnks you made it easy

  • @Sandy-we6sb
    @Sandy-we6sb 6 років тому +1

    Good explanation sir tq

  • @hindurashtrrawat483
    @hindurashtrrawat483 4 роки тому

    Thank you
    Good method to show practically

  • @manhalibrahim8951
    @manhalibrahim8951 5 років тому

    thank you sir good explaination

  • @Ak-lt8zy
    @Ak-lt8zy 6 років тому

    Very helpful. .Thanks

  • @mythril4
    @mythril4 4 роки тому +2

    This video is older but one small thing, use motor reverse contractors. They have a bar inside them that crosses between contractor preventing both from ever being active at the same time creating a 3 phase short.

  • @conraddebeer1662
    @conraddebeer1662 6 років тому

    Good video Mr... A thamk you all the Way from South Africa.. you okes are great with electrics..

  • @rishikeshmaurya6314
    @rishikeshmaurya6314 5 років тому

    Thanks for this video

  • @nicholasr79
    @nicholasr79 4 роки тому

    The use of the English language in this comment section is absolutely stellar.

  • @dlarun5337
    @dlarun5337 6 років тому

    Good explanation

  • @nandimadayas9318
    @nandimadayas9318 6 років тому +4

    good showing easy to realise but try to fix dinrail to contactor also i like to know a t s controle system wiring iam dias from sri lanka

  • @nilanga410
    @nilanga410 3 роки тому

    Good job. Thank you sir

  • @malcolmevans941
    @malcolmevans941 5 років тому

    Another good video

  • @bharanithoughts4248
    @bharanithoughts4248 5 років тому +1

    Super sir . I need to connection of conveyer with use of reverse and forward medium. Speed

  • @ajaydeswal4672
    @ajaydeswal4672 6 років тому +1

    Very nice video....can you make a video use of AC contactor main, star ,Delta starter with out timer.

  • @yungstroller_sa6345
    @yungstroller_sa6345 3 роки тому

    THUMBS UP ,,,THIS VID IS MORE DETAILED

  • @ariyabuthiran0072
    @ariyabuthiran0072 6 років тому

    Thanks bro

  • @veerabhaskar8193
    @veerabhaskar8193 5 років тому

    Thank u bro

  • @cliveharrison-43
    @cliveharrison-43 4 роки тому

    Interesting should do one also showing push buttons using and auxillery contact as a latch and also as a interlock

  • @tiknosvenue711
    @tiknosvenue711 4 роки тому +1

    good job tank you

  • @chickedwin7194
    @chickedwin7194 5 років тому

    Good one there bro.thanks

  • @d.kkumar4186
    @d.kkumar4186 5 років тому

    High quality nice

  • @yogeshmishra3840
    @yogeshmishra3840 6 років тому

    Thanks sir

  • @nekkantisrinivas2119
    @nekkantisrinivas2119 5 років тому

    thankyou bro

  • @shashikantsinghrajput9033
    @shashikantsinghrajput9033 5 років тому

    Thanks🙏🙇 sr

  • @tejaswinilucky88
    @tejaswinilucky88 Рік тому +1

    Super sir

  • @eng.mosabkhlefat3278
    @eng.mosabkhlefat3278 3 роки тому

    Thank you

  • @TechTricks786
    @TechTricks786 4 роки тому

    Good job 👍

  • @shravanyadav395
    @shravanyadav395 2 роки тому

    Very halful video sir 🙏🙏

  • @SaiKumar-wk4mk
    @SaiKumar-wk4mk 4 роки тому +1

    Sometimes a possibility of stuck the contactor due to mechanical problems. In this method no interlock is provided to avoid phase to phase short circuit in such case. Add one NC contact and take coil supply through it, ie the supply to F is in series with the NC of R and vice versa.

    • @starautomation
      @starautomation  4 роки тому

      Yes. NC contact of Rev Contactor in series with Fwd Contactor coil and similarly NC contact of Fwd contactor in series with Rev Contactor coil is required for electrical interlock.

    • @SaiKumar-wk4mk
      @SaiKumar-wk4mk 4 роки тому +1

      @@starautomation One more disadvantage is there. No protection is provided for the motor. Two expensive contactors are used. An overload relay and 3 push button is required for this. I think the conventional circuit is better than this.

  • @MediaBangladesh94
    @MediaBangladesh94 6 років тому

    very so nice

  • @RAHULSHARMA-cv2kk
    @RAHULSHARMA-cv2kk 5 років тому

    Can the same be used for 3-phase linear induction motor?

  • @dilipram1329
    @dilipram1329 5 років тому

    Nice video sir

  • @makokambrose6920
    @makokambrose6920 4 роки тому

    Nice work

  • @gangareddykore6363
    @gangareddykore6363 6 років тому +1

    Very good video

  • @ArunSingh-dl4gj
    @ArunSingh-dl4gj Рік тому

    Bhai. Sab. Dhanybad

  • @vinodkumare7
    @vinodkumare7 6 років тому

    Nice bro

  • @SanjayKumar-il2bz
    @SanjayKumar-il2bz 3 роки тому +1

    Very easy

  • @Godfa539
    @Godfa539 2 роки тому

    Very clear

  • @servistools7194
    @servistools7194 3 роки тому

    Elhamdulilah

  • @mannyreyes4811
    @mannyreyes4811 4 роки тому +1

    Good job brother ....
    May I know the model of contactor and the switch please .. thanks

  • @bujjyboddu4503
    @bujjyboddu4503 4 роки тому

    Thank u sir,use full vidio,
    i want same motor,
    motor rpm, hp what sir ,
    give me reply sir

  • @user-vg9nn8pv8i
    @user-vg9nn8pv8i 5 років тому

    Hi I want to make a circuit with 220V, not 3-phase. Also automatically it can rotate reverse and forwad. PLEASE let me know. Thanks

  • @virustracker4840
    @virustracker4840 5 років тому

    Thanks nice vid

  • @kalpeshrathod80
    @kalpeshrathod80 5 років тому

    Mnx 25 and havells timer fitting wire fitting

  • @d.kkumar4186
    @d.kkumar4186 6 років тому +1

    Nice

  • @danielmark3077
    @danielmark3077 5 років тому

    thank at least i have learn some thing

  • @shailendrasingh9263
    @shailendrasingh9263 5 років тому

    Very good

  • @aliwaleed6432
    @aliwaleed6432 4 роки тому

    Verry good

  • @divyapradhan9452
    @divyapradhan9452 5 років тому

    NICE VIDEO SIR, R.B.PRADHAN CHENNAI (TAMIL NADU)

  • @umeereshu
    @umeereshu 5 років тому

    Sir u r not gave a input connection in l1,l2,l3 but that connected to output side (reversed) & a1 gave to neutral instead of phase..

  • @mardiasultanamoni6060
    @mardiasultanamoni6060 5 років тому

    nice

  • @mumgurung3577
    @mumgurung3577 5 років тому +1

    Nice video,per aap hindi me video banaao to achha hoga . Schneider contactor or 14pin wala really,push button lagaake reverse forward stater control connection wearing video dekhado please.

  • @ojiralam1233
    @ojiralam1233 2 роки тому

    Good joop sir

  • @noelphiri1722
    @noelphiri1722 4 роки тому

    Nice one

  • @muhammedafsal7806
    @muhammedafsal7806 4 роки тому

    Can i use no nc terminal contact instead of cam switch

  • @alfredibidapo6640
    @alfredibidapo6640 2 роки тому

    How can I use DTDP toggle switch to connect the contactor instead of selector you have used.Thanks

  • @moviedekho8244
    @moviedekho8244 5 років тому

    How connected rotary switch supply

  • @sombdr2032
    @sombdr2032 5 років тому

    Please sir more information

  • @jocelynbruces3898
    @jocelynbruces3898 4 роки тому

    i try to understand the way you discuss soo far it is ok...but next time you blog...you should put label on it every wire end and put a motor control wiring diagram...

  • @nafeeskhan-kd6ws
    @nafeeskhan-kd6ws 5 років тому

    Very nice sar mujhko penal ki or jankari .

  • @SB-vv1uh
    @SB-vv1uh 3 роки тому

    Nice video, I just wanted to know which motor you use i just want same setup and bought everything which you showed in this video only motor have to choose..please guide

    • @starautomation
      @starautomation  3 роки тому +1

      Motor should be 3-phase induction motor. Motor current rating should be less than contactor current rating.
      Suppose motor current rating is 3 Amps. Then for Direct online starting, contactor current capacity should be 6 times. So, 6x3 = 18A.
      So select contactor of 18A or 25A current rating.

  • @jayathissavitharana4053
    @jayathissavitharana4053 5 років тому +9

    1 is connect to pase suply. but you don't show it us

  • @abasjabr7573
    @abasjabr7573 2 роки тому

    please this connection for single or 3phase motor nice video

  • @milanprvulovic2544
    @milanprvulovic2544 5 років тому

    What's this black wires connect a switch?

  • @V3_one
    @V3_one 6 років тому

    Sir u r super
    clear cut video
    and
    But i have a one another doubt that is
    Q: what is small connetors imean i saw on contactor small aditional connectors what is the use

    • @starautomation
      @starautomation  6 років тому

      Contactor do have Normally open contact and normally closed contacts, also called as NO and NC contacts.
      When contactor is switched On, NO contact gets shorted and NC contact gets open circuit.
      These contacts are used in control wiring.

  • @naveenkumar9025
    @naveenkumar9025 4 роки тому

    You took phase for switch point 1.. and you took neutral from A1 point of both contactor.. it is clear.. and what you did the long wire of contactor..

  • @microsalesservices9295
    @microsalesservices9295 6 років тому

    Please video banao hume jarurt padti hai useke connection kaise hote hai

  • @manojbisht2002
    @manojbisht2002 4 роки тому

    Sir pl 4 moter ready one by one star connector connection and three phase thanks

  • @gurupowersystems4441
    @gurupowersystems4441 5 років тому

    very nice please termination crimping the luges praperli

    • @starautomation
      @starautomation  5 років тому

      Of course. We should use proper lugs along with crimping tools to fix it.

  • @darmintoaji3159
    @darmintoaji3159 4 роки тому

    Di tambah pakai timer bang, biar jalan bolak balik sendiri🙏🙏

  • @gordhardmkisi9243
    @gordhardmkisi9243 4 роки тому

    How the contecter works

  • @ermiastaye3095
    @ermiastaye3095 4 роки тому

    I shall something to do

  • @vijaykansal6804
    @vijaykansal6804 5 років тому

    👍

  • @nileshthosar6907
    @nileshthosar6907 5 років тому

    V nice

  • @heesir9762
    @heesir9762 4 роки тому

    My starter motor only one wire how to make forward n reverse can you send me diagram showing

  • @dineshpatil3249
    @dineshpatil3249 5 років тому

    Mast banaya hai Lekin hindi mai banao

  • @skyways5165
    @skyways5165 6 років тому

    Sir apne selector switch ka 1terminal kha connection kiya

  • @dnyaneshwarkale6724
    @dnyaneshwarkale6724 3 роки тому

    Automatic limit switch use reverse forward motor

  • @ajaydeep9765
    @ajaydeep9765 5 років тому +1

    interlocking krna jaruri tha bro... agr contector chipk geya toh three phase flash mare ga.

    • @starautomation
      @starautomation  5 років тому

      You are right but the MCB used at input supply will take care of short circuit protection

  • @faddifaddi2261
    @faddifaddi2261 4 роки тому +1

    phase nikala kaha say liya main cable say nikal gaya a1 say , R F mi lag gayi tar magr 1 or 2 point smj ni aya q kay cam wrong direction mi tha

  • @electricgyancentre3722
    @electricgyancentre3722 6 років тому

    All electrical panel knowledge hindi 👉 electric gyan center

  • @jamalhussain6487
    @jamalhussain6487 5 років тому

    I don't know where you contact the selector switch wire 1

    • @jamalhussain6487
      @jamalhussain6487 5 років тому

      Jo aap bolty Hy k ye phase sy connect Hy mager Kedar

  • @rabinrahulmohanty4255
    @rabinrahulmohanty4255 5 років тому

    Sir diagram ke sath video karenge Tao Acha hota plz sir

  • @dattarajdevalkar1794
    @dattarajdevalkar1794 2 роки тому

    plz provide names of the components used in this circuit

  • @subhajitsubho5999
    @subhajitsubho5999 3 роки тому

    Please attach drawing along with this.

  • @mandipkamboj1484
    @mandipkamboj1484 3 роки тому

    Overload relay?

  • @JoseLopez-sz5zj
    @JoseLopez-sz5zj 4 роки тому

    Easy is just change the line

  • @sandeepdakhara3776
    @sandeepdakhara3776 5 років тому

    Singal phase motor reverse forward kese kare

  • @hotcoke648
    @hotcoke648 5 років тому +1

    Where is the "point 1 for the switch" connected to?

    • @attiqrehman8989
      @attiqrehman8989 3 роки тому

      To any live phase out put of main contactor

  • @microsalesservices9295
    @microsalesservices9295 6 років тому

    SIR only rotory switch used a reverse and forword

  • @sivatech9876
    @sivatech9876 4 роки тому

    Sir without contactor me reseve nahi hoga.. reply me

    • @starautomation
      @starautomation  4 роки тому

      To change rotation of motor, we need to change phase sequence.
      Both contractors have opposite phase sequence.
      Other way of doing this will be to use Variable frequency drive. In this case, Contactors will not be required.

  • @christophesoh3961
    @christophesoh3961 6 років тому

    Formation en françai svp

  • @mdshahasat2352
    @mdshahasat2352 5 років тому

    shahadar