  • Installing the Nu-Calgon Iwave R for these customers. Just showing how I do it. Let me know if you yall use this product or believe in it. Appreciate y’all and enjoy! #hvac #hvaclife #bluecollar #skilledtrades #nucalgon #iwave #cleanair #installation #veto #milwaukeetools #howto #tutorial

КОМЕНТАРІ • 36

  • @angelagosto8327
    @angelagosto8327 2 роки тому +4

    Love the crocs flow bro😂

    • @KoolinwithKrauss
      @KoolinwithKrauss  2 роки тому

      Work smarter not harder 🤣 I forgot my boots that day and just went for it 😂

  • @chevymom9776
    @chevymom9776 2 роки тому +1

    Neat job

  • @enix82
    @enix82 Рік тому +1

    I haven't seen a video, reddit post, or anything about installing the alarm / dry contact brown wires. It seems like a great idea to put a light on it so the owner knows it's working. My question about is how to power the dry contacts alarm wire. Can you pigtail off the 24vac? I've only seen one person mention installing it and they alluded to a separate transformer. Have you ever installed the dry contact / alarm feature?

    • @KoolinwithKrauss
      @KoolinwithKrauss  Рік тому

      I’ve never personally installed the feature. The unit does have an LED indicator (but inside the cabinet) it’s also possible to mount this on the outside and be visible from the outside but Do to access not able to on this application!

  • @justin9605
    @justin9605 8 місяців тому +1

    Thank you.

  • @donjohnson2578
    @donjohnson2578 Рік тому +1

    I live in the west Palm Beach area of Florida. I have a full/ regular and a mini split system. Does any one live in or around the area who does this install? Thx

    • @KoolinwithKrauss
      @KoolinwithKrauss  Рік тому

      I would reach out to your local companies in the area and shop around 👍🏻

  • @stonecollins8718
    @stonecollins8718 2 місяці тому +1

    The installation manual I’m seeing suggest installing it “between air filter and cooling coil”. Do I have the wrong info?

    • @KoolinwithKrauss
      @KoolinwithKrauss  2 місяці тому +1

      It does say that, info isn’t wrong. Gives multiple mount positions. Says you can mount it in the inlet side of the fan (shaft side) it’s not a very clear identifier. But does highlight in bold what you are reading.

  • @waynemiles7027
    @waynemiles7027 Рік тому +1

    Wouldn’t that work better before the evap coil? It would help keep the growth down on the coil?

    • @KoolinwithKrauss
      @KoolinwithKrauss  Рік тому

      With this device the manufacture states to install by the fan inlet (shaft side) I would think since it’s not a typical uv die ice and an ionizer instead

    • @hawksnest8635
      @hawksnest8635 Рік тому

      @@KoolinwithKrauss also with that type of unit, it is either a N or a M coil. Hence no room B4 cioil

    • @Sunrise_HVAC
      @Sunrise_HVAC Рік тому

      No it will not work as advertised if you put it before the coil.

  • @kernow62
    @kernow62 Рік тому +1

    Do you have it powered up all the time or only when blower is running?

    • @KoolinwithKrauss
      @KoolinwithKrauss  Рік тому +1

      It has constant power applied but releases negative ions into the airstream when blower runs

    • @kernow62
      @kernow62 Рік тому

      @@KoolinwithKrauss I hooked mine to green lead for fan. Should I swap it? Mine is a heat pump with no strip.

    • @KoolinwithKrauss
      @KoolinwithKrauss  Рік тому

      @@kernow62 black to a hot wire same with white and green to ground. That’s how I do it

    • @kurupt91748
      @kurupt91748 Рік тому

      @@KoolinwithKrauss isn't black wire to R and white wire to C?

  • @MFD541
    @MFD541 3 місяці тому +1

    What keeps this from sweating where you removed the insulation?

    • @KoolinwithKrauss
      @KoolinwithKrauss  3 місяці тому +1

      I cut it pretty tight, if that cabinet starts to sweat there, larger issue at hand. But I’ve installed over 100 of there’s in past 5 years and haven’t had an issue when I go back for maintenances

    • @MFD541
      @MFD541 3 місяці тому

      @@KoolinwithKrauss Great to hear! thanks for the reply.

  • @hvacdepot
    @hvacdepot Рік тому +1

    Would you mind to name a retails price for installed iWave? Thanks

    • @KoolinwithKrauss
      @KoolinwithKrauss  Рік тому +1

      Depends on market. I believe could run from 750-1250

    • @hvacdepot
      @hvacdepot Рік тому

      @@KoolinwithKrauss thanks! . I used to install the micro pure purifiers, but thinking to switch to Iwaves, mainly because it is maintenance free, easier on a customer.

  • @hawksnest8635
    @hawksnest8635 Рік тому

    using the magnets and placing it on the blower do the same?
    where you placed it is in turbulence area since air is being drawn from both sides and it is not a "air stream" just air getting sucked in. Also cutting out insulation will cause it to sweat, since there is a slight gap caused by the magnets. Also if the airhandler is hoz. nd you mount it on the bottom, and the units drain cloggs up, the i-wave will get wet.

    • @KoolinwithKrauss
      @KoolinwithKrauss  Рік тому +4

      For sure all your points are accurate. Just going with the manufactures instructions that state install at the shaft area of the blower wheel. I’ve installed these for a few years and haven’t had any sweat issues.

  • @michaelgreer8659
    @michaelgreer8659 9 місяців тому +1

    I was gunna watch till you rang a dam bell

  • @eyedrz
    @eyedrz 4 місяці тому +1

    Darn. You skipped over the most important part. What wire goes to what terminal.

    • @KoolinwithKrauss
      @KoolinwithKrauss  4 місяці тому

      My bad 🤦‍♂️

    • @madeinusa1576
      @madeinusa1576 3 місяці тому

      It does get shown where it gets worse you can see if you watch it, was taken to the terminal block

  • @Sunrise_HVAC
    @Sunrise_HVAC Рік тому +1

    THAT is way too much work….. I install these a lot and that is crazy what your doing. I guess people do there own thing. You could have saved yourself a lot of work by installing in a different way but this video is not something I would show my tech in how to install one.

    • @KoolinwithKrauss
      @KoolinwithKrauss  Рік тому

      Takes about 5-10 minutes not that excessive amount of time and gets it directly into the blower, which is what manual recommends to be the best. I see a ton of of these just slapped on the blower housing even just on top of the A coil which is inadequate.