Ceiling fan common, start, run wire identify with multimeter! Ceiling fan connection

Поділитися
Вставка
  • Опубліковано 16 кві 2020
  • 3 wire ceiling fan me common, start, run identify with multimeter
    In this video we explain 3 wire ceiling fan common, start, and running winding with multimeter. We know in ceiling fan their are two winding
    1.starting winding or auxiliary winding
    2.main winding or running winding
    We can identify these winding by measuring resistance
    We take resistance in all three terminal
    If resistance come high than these terminal or start and run
    Than other terminal is common
    Now take resistance between common to other two terminal than high resistance will be starting and low resistance running winding
    In this video we explain very easily for more information just watch and learn
    3 wire ceiling fan connection
    • CEILING FAN CONNECTION...
    Siemens drive parameter setting and connection
    • SIEMENS SINAMICS V20 D...
    How to calculate kwh or electrical bill calculation
    • WHAT IS KWH(UNIT)? HOW...
    Cable testing with multimeter
    • HOW TO TEST CABLE WITH...
    Reverse forward starter power wiring connection
    • REVERSE FORWARD STARTE...
    Manual reverse forward starter with limit switch
    • How to make Reverse fo...
    Automatic reverse forward starter
    • Star Delta starter pow...
    Automatic reverse forward motor starter connection
    • Automatic reverse forw...
    3 phase rccb test on single phase supply practical
    • 3 PHASE RCCB मे SINGLE...
    3 phase ammeter connection with selector switch
    • 3 PHASE AMMETER CONNEC...
    8 pin relay testing with multimeter
    • 8 PIN RELAY TESTING WI...
    How to check ceiling fan common start run with multimeter
    • 3 WIRE CEILING FAN COM...
    How to make dol starter with relay
    • How to make dol starte...
    How to check ceiling fan common start run with series lamp
    • Video
    ammeter connection with current transformer
    • 3 PHASE AMMETER CONNEC...
    Cooler motor testing with series test lamp
    • COOLER MOTOR TESTING W...
    Street light timer setting
    • STREET LIGHT TIMER SET...
    Air compressure power & control wiring practically
    • AIR COMPRESSURE के ST...
    3 phase cable testing with megger
    • HOW TO CHECK CABLE INS...
    3 phase motor test with megger
    • Induction motor test (...
    Dol starter control from different points
    • MOTOR CONTROL FROM DIF...
    How to make reverse forward motor starter
    • How to make Reverse f...
    Manual reverse forward starter with limit switch
    • How to make Reverse fo...
    Automatic reverse forward starter
    • Star Delta starter pow...
    Automatic reverse forward motor starter connection
    • Automatic reverse forw...
    Thanks for watching

КОМЕНТАРІ • 164

  • @JagiChan
    @JagiChan 3 роки тому +8

    The video quality is good and the explanation is detailed and clear.👍🏻

  • @chintadav.suryarao2579
    @chintadav.suryarao2579 3 роки тому +4

    Your explanation is good. But Cum resistance vala starting winding....high resistance vala running winding.

  • @NothingNew_01
    @NothingNew_01 3 роки тому

    Achha explain kiye h sir...Thanks

  • @tripathi.harshmani
    @tripathi.harshmani 3 роки тому +1

    thnq sir.. really very nice explanation.. i have just seen a video with more view count. but your video is much better and detailed

  • @MrRamzanhabib
    @MrRamzanhabib Рік тому

    Bohet acha samjhaya hai ap nae. Stay blessed brother

  • @Shaileshshivne
    @Shaileshshivne 3 роки тому +1

    Bhut achha samzaye h aapne pehli bar me hi subscribe kr diya aapko

  • @mrigankachatterjee5870
    @mrigankachatterjee5870 Рік тому

    Excellent explanation. Keep the good work

  • @sankarchandradeb8084
    @sankarchandradeb8084 Рік тому +4

    In any types of ceiling fan running coil will show maximum resistance but in any other induction motor using pumping water and any other liquid will show minimum resistance in running coil, it's my practical experience. Thanks

  • @mistercool1191
    @mistercool1191 16 днів тому +1

    clear explanation...namaste..🙏🏽

  • @jacobbabu607
    @jacobbabu607 Рік тому

    Superb well explained

  • @Zeeshankhan-qn5yv
    @Zeeshankhan-qn5yv 4 роки тому

    Very easy explained identity to wire

  • @Durraniboy798
    @Durraniboy798 2 роки тому +4

    Kyunki starting winding small hota hai isliye iska resistance Kam hona chahiye please explain sir ji

  • @iqrasteambathandsolutionmu763
    @iqrasteambathandsolutionmu763 3 роки тому +1

    Thanks sir problem solved from Pune

  • @ritwikbandyopadhyay2181
    @ritwikbandyopadhyay2181 2 роки тому

    good and informative

  • @bhavinmaru4024
    @bhavinmaru4024 3 роки тому +1

    Very good explain...👍

  • @prahladsingh9630
    @prahladsingh9630 2 роки тому +1

    starting and running winding resistance value confusion create so clear my confusion

  • @RatheeshRTM
    @RatheeshRTM 4 місяці тому +1

    Well explained 👌👌thankyou🎉
    Running winding resistance low and starting high. AC or fridge compressor motor resistance is differant it's running resistance high and starting low! Am I right?

  • @mandelasowjanya9643
    @mandelasowjanya9643 Рік тому

    Very good explain

  • @npnaidu4131
    @npnaidu4131 2 роки тому

    Excellent 🙏

  • @sudamnaik7633
    @sudamnaik7633 4 роки тому

    Thanks sir 👍

  • @mdtutorialgoon1448
    @mdtutorialgoon1448 2 роки тому

    Thank you so much sir

  • @techview6933
    @techview6933 4 роки тому

    Nice!!!

  • @mdkhan5007
    @mdkhan5007 Рік тому

    Thank you brother

  • @TengrakMSangma
    @TengrakMSangma Рік тому +1

    Sapke video alak alak hai bhai kuch video mein running wire koh phase diya aur aapke video mein starting wire koh aapne phase diya 😇😇😇

    • @SNTECHNICAL
      @SNTECHNICAL  Рік тому +1

      Sir 3 wire fan me ap phase starting running kisi me bi de skte h fan jlega nhi
      But apko fan ko sida ghumaane k liye fan ko starting me dena hoga

    • @TengrakMSangma
      @TengrakMSangma Рік тому

      @@SNTECHNICAL lekin ulta jayega bhai

  • @jehirulislam1029
    @jehirulislam1029 4 роки тому +7

    Supply running wire me dena sahia

  • @shafanhussainmew2932
    @shafanhussainmew2932 4 роки тому

    Very nice bhai

  • @sarfarazbakali9357
    @sarfarazbakali9357 9 місяців тому

    Thanks

  • @shahidsarker8339
    @shahidsarker8339 Рік тому

    very nice video

  • @farahabdi8616
    @farahabdi8616 4 роки тому

    Thanks sir

  • @virendrasinghsejwal-hu6dh
    @virendrasinghsejwal-hu6dh Рік тому +2

    I saw other videos, they were saying phase shud be connected to running wire and not starting wire.

  • @4629jay
    @4629jay 3 роки тому +4

    Ceiling fan ki running winding ka resistance jyada kyu hota h outer coil ka jisme phase connect hota h
    Iss fan ki red wire running winding ki h outer winding aap check kijiye fan me running ka resistance jyada hota h

  • @mangalagiriramesh5936
    @mangalagiriramesh5936 3 роки тому +1

    Superb sir!

  • @murtidevi3266
    @murtidevi3266 3 роки тому

    Very nice

  • @SwingMotor
    @SwingMotor 3 роки тому +1

    Nice concept

  • @HarHar_Mahadev198
    @HarHar_Mahadev198 Рік тому +1

    Wao mast bro

  • @Salloudintamoor6017
    @Salloudintamoor6017 Рік тому +1

    Hello Bhupendra ji

  • @DharmendraKumar-re3sn
    @DharmendraKumar-re3sn 2 роки тому +2

    Jiska value jyada he wo running coil he sahab aap usko starting bataraheho usme supply v deraheho

  • @mangeshpatil283
    @mangeshpatil283 Рік тому

    Super

  • @user-xr5nz1bg6j
    @user-xr5nz1bg6j 4 роки тому +8

    connection rong ..starting winding wire centre connection karana..

  • @saravanamg7593
    @saravanamg7593 Рік тому

    Very good

  • @Ankit_Sharma_88
    @Ankit_Sharma_88 4 роки тому

    Please make individual video of
    How to make holding in contactor just like u made for 11 pin glass relay

  • @h.d.veerarajeursmysore4043
    @h.d.veerarajeursmysore4043 2 роки тому

    Super sir

  • @nareshkumarbarot3043
    @nareshkumarbarot3043 3 роки тому

    Good

  • @yograi6639
    @yograi6639 2 роки тому

    good video

  • @cncmachines9836
    @cncmachines9836 2 роки тому

    nice

  • @sannichaudhary1825
    @sannichaudhary1825 2 роки тому

    To good bhai

  • @professionalrepairpr4737
    @professionalrepairpr4737 2 роки тому

    Kishi bhi induction motor ki starting running common vending ko identify karne ke liye sabse simple Jin do terminal per sabse jyada resistance aati hai usse bacha hua terminal common hota hai common to Ho Gaya common ke sath jis terminal per sabse jyada resistance aati hai vah starting bending hoti hai Jo last mein bacha hai wah running vending ho gai....

  • @realitykol6934
    @realitykol6934 2 роки тому +2

    3:25 starting ka resistance kum hota hai running ka zayada hota hai kyu ki running coil bahar hota hai aur wo zayada bada hota hai. Thek se pata kijiye bhai! Aise me sekhne walo ko garbar ho jayega.

    • @shriharikokare5764
      @shriharikokare5764 2 роки тому

      sahi hai bhai..
      lekin theroy me
      running winding conductor size mothi hoti hai compare to starting winding isliye theroy me running winding ka resistance kam hota hai..
      practically same conductor size use karte hai.. isliye practically me running winding ka resistance jyada hota hai

  • @Munny606
    @Munny606 3 роки тому +1

    the fan rotates anticlockwise seen from below
    manufacturers install the 2.5MFD capacitor in the running winding(low resistance coil)
    in series instead of the induction motor theory that capacitor must be in series
    with the starter winding(high resistance coil)

  • @4629jay
    @4629jay 4 роки тому +3

    Red wali wire to outer winding/running winding se connect h na sir ji .???
    Bajaj ceiling fan data
    Starting winding mein number of turns 360 turns 36 swg
    Running winding mein 410 turns 36 swg

  • @rakeshkumarmaurya416
    @rakeshkumarmaurya416 4 роки тому +5

    Lamp se Batao sir

  • @ashusain6595
    @ashusain6595 2 роки тому +5

    I get confused. One says higher resistance is staring another says low resistance is starting, one says inner winding is sarting some says outer is starting!
    Low resistance= running ua-cam.com/video/9s2NbqbwKWk/v-deo.html
    More resistance= Running ua-cam.com/video/--wfOp-ScQg/v-deo.html
    low resistance= Starting ua-cam.com/video/D1UsvW5RpPQ/v-deo.html
    Outer winding is starting or inner is starting
    If wire size is same in both starting and running winding then resistance of which winding will be higher, starting or running ?

    • @mitul2233
      @mitul2233 Рік тому

      Bruh staring to common winding has higher resistance compared to running and common

  • @MDMEHEDIHASAN-gy8fs
    @MDMEHEDIHASAN-gy8fs Рік тому

    ❤️❤️❤️❤️

  • @subhankarsarkar4800
    @subhankarsarkar4800 4 роки тому +2

    Sir tebil fan ka canection btya

  • @engineeringdepartment4688
    @engineeringdepartment4688 3 роки тому +7

    Start winding must be one ended capacitor and other winding end must be supply plus capacitor

  • @parakramsinhzala6432
    @parakramsinhzala6432 2 роки тому +2

    Resistance jyada vo running
    Resistance kum vo starting Right he
    But Is video me ulta bola he

  • @SoumenDalapati-up2sx
    @SoumenDalapati-up2sx 14 днів тому +1

    Me vi ahi kahe raha ta

  • @regencysarvam7206
    @regencysarvam7206 2 роки тому +2

    Mera technician bolte hain Phase to be connected to Running and not to the starting... Common par neutral nagana hai.... please confirm.

  • @Salloudintamoor6017
    @Salloudintamoor6017 Рік тому

    Hello Bhupesh ji

  • @mdnafis8220
    @mdnafis8220 3 роки тому

    Sir padastal fan ka connection bataye multimeter se

  • @ArvindKumar-hk4ht
    @ArvindKumar-hk4ht Рік тому

    Hello Bhai

  • @dot.sattamatka6356
    @dot.sattamatka6356 2 роки тому

    सर फॅन के starting winding को phase diya जाता हैं या running winding को? प्लीज जवाब दे

  • @tipusultan6685
    @tipusultan6685 2 роки тому

    Running wire upar me lagega bro starting wala bich me aise hoga

  • @himanshuchandwani7494
    @himanshuchandwani7494 8 місяців тому

    Bhai starting wire ki reading kam hoti h and running ki jyada ho sake to ek bar check karke video sudar do

  • @gnyankalita9829
    @gnyankalita9829 2 місяці тому

    Fan ki movment clockwise nisese ya uperse liya jata hai

  • @anishresho9145
    @anishresho9145 3 роки тому +1

    Is single phase winding connection common to all motors and other appliances, mixie,washing machine,Grinder,Ceiling fan,Pedastel fan and Table fan

    • @professionalrepairpr4737
      @professionalrepairpr4737 2 роки тому

      Mixer- universal motor
      Washing machine- semi automatic induction motor , automatic induction motor, front loading washing machine universal and DD motor use,
      Grinder universal motor use ceiling fan induction motor
      Pedastal,table use single phase induction motor

  • @tipusultan6685
    @tipusultan6685 2 роки тому

    Common or running me main suply jayega bhai

  • @arunthangaraj8364
    @arunthangaraj8364 4 роки тому +1

    fan always rotates in anticlockwise

  • @babukartik6124
    @babukartik6124 Рік тому +2

    Running kaa resistence jyaadaa honaa chahiye. Aapne running kaa kam dikhaayaa?

  • @sandeepmohapatra8659
    @sandeepmohapatra8659 2 роки тому

    Sir starting wire me phej dena chahiye yaa running wire me?

  • @saifazmi534
    @saifazmi534 Рік тому

    Point 506 lijiyea

  • @pankajchhetri4901
    @pankajchhetri4901 2 роки тому +1

    Running coil me turn jyada hote hai to resistance bhi jyada hoga

    • @SNTECHNICAL
      @SNTECHNICAL  2 роки тому +1

      Nhi running coil me jo wire use hota h vo mota hota h
      Isliye resistance km hoga
      Or resistance km hoga tbi current jada flow hoga

    • @pankajchhetri4901
      @pankajchhetri4901 2 роки тому

      @@SNTECHNICAL ok sir

  • @Mohd_Hassan480
    @Mohd_Hassan480 4 роки тому +1

    ....jab single pole ki mcb koi load me connect hai yaa manlo ghar ke main.. Bord me connect hai aur neutral direct hai.. To koi bhi short cercuit me hamari mcb single pole wali trip ho rahi hai.. To hum 2 pole ki mcb q lagate hai. Iska kya reasion hai.. Kya 2 pole ki mcb jaruri hai ....plzz reply me.

    • @techchannel4173
      @techchannel4173 3 роки тому

      Two pole mcb mei dono phase and neutral control hota hai iske baad neutral ko har point mei dena hai

  • @venkataraomadisetty4392
    @venkataraomadisetty4392 Рік тому

    What are the connected wire gauze from starting. Running & comon

  • @maheshpal1636
    @maheshpal1636 2 роки тому

    Bulb sirij se batave please

  • @rajivkatara3419
    @rajivkatara3419 3 роки тому

    Video on table fan connections?

  • @prashantpatel39666
    @prashantpatel39666 2 роки тому

    Srating me dege to fan nahi jalega ?

  • @Vickykumar-hu1in
    @Vickykumar-hu1in Рік тому

    Running wale mein face dena hai bhai ji aur Koman Newton dena

  • @nadim606
    @nadim606 8 місяців тому

    seen

  • @primewavez
    @primewavez 2 роки тому

    R u know about
    Electric and winding
    or just video making.
    How give the power supply to starting and common
    Always
    Power supply give to
    Running and common
    Starting connect with capacitor

  • @NurIslam-ji9so
    @NurIslam-ji9so Рік тому

    ❤Agor show na ho to Kay kore ।

  • @ismailmohammed5588
    @ismailmohammed5588 2 роки тому

    Sir ceiling fan rotates anti clock wise iam correct

  • @techchannel4173
    @techchannel4173 3 роки тому +2

    Sir yellow is common but black is starting and Red is Running. Kyuki Running mei turns jyada hota hai so Resistance bhi jyada hoga.plz explain sir

  • @spartankinga2659
    @spartankinga2659 2 роки тому

    பேன் ஓடிய சிறிது நேரத்தில் ரொம்ப சூடாகிறது . பேன் ஓடமாட்டங்கிறது என்ன செய்ய தயவுசெய்து சொல்லுங்கள்

  • @Runnergaming101
    @Runnergaming101 2 роки тому +1

    Common wire hmesa niche lagana hota h kya sir?

    • @SNTECHNICAL
      @SNTECHNICAL  2 роки тому

      Ap sbse niche bi lga skte h ya sbse upr bi lga skte h
      But kbi bi bich me nhi lgana h

    • @Runnergaming101
      @Runnergaming101 2 роки тому

      @@SNTECHNICAL Thnks sir❤🙏

  • @shafiahmed2880
    @shafiahmed2880 2 роки тому

    Sir normalse starting aur runningke beechme capacitor lagayajathahai.aur phase running windingkesath lagaya jathahai.lekin sirf ceiling fanmehe phase starting windingse lagayajathaheykya sir?

  • @phepdhosl7697
    @phepdhosl7697 2 роки тому

    How to check coil in fan multimeter

  • @nandumeshram4656
    @nandumeshram4656 2 роки тому

    भाई. Running wire मे दोनो सिरे से multimeter से reading 47-56 आ रहा है.साथ मे कभी कभी बिप की आवाज भी आती.तो क्या ये reading सही है क्या. और स्टेटर मे भी reading बताता है. क्या fault होगा

    • @Rahul.patel48
      @Rahul.patel48 2 роки тому +1

      Body earth nhi hona chahiye wire kahi se body se touch hoga isiliye stator par continuity mil rhi

  • @dattavaze1982
    @dattavaze1982 11 місяців тому

    What happens in the fan if a capacitor is connected to the common wire

  • @sahabuddinlaskar7863
    @sahabuddinlaskar7863 2 роки тому

    Sir app galat bolrhaho. Commen wir K saath starting war ka repentance kam hoga. Or runing war me jada hoga.

  • @rambhaigurung960
    @rambhaigurung960 11 місяців тому

    ये आप्का उल्टा घुमेगा
    Fase और नुटन common our running+capacitor मे लगेगा
    लोगो को सहि जानकारी दे confuse ना करे प्ल्ज़ thanks 😮

  • @NyvaanSribastav
    @NyvaanSribastav Рік тому +1

    Ko to bich mein bhi de sake Na bhai jo commonweal hota hai usko to ham log bich mein bhi de sakte hain ki middle mein aur jo running aur starting mein hua hota hai vah upar kar aur upar ke side aur niche karo side de sakte hain ham log to Bhai niche ke side mein aise de rahe ho bhai to confuse ho jaenge bhai ham log kya hai tum dikha rahe Ho video kuchh achcha sa batao kuchh samajh mein nahin a raha hai bhai aise Tum Bhai pata hai Bhai tumko pata hai ham log Ko nahin pata ham log abhi Sikh rahe hain but Aisa kuchh mat batao yaar samajh mein nahin aata hai

  • @herik63
    @herik63 3 роки тому

    Ok the English title, but the subtitle?

  • @4629jay
    @4629jay 4 роки тому +1

    Aap ye wala fan open krke dikha skte ho kya red wire outer/running winding se connect h ya inner/starting winding se 🙏🙏🙏
    Mera doubt clear hojayega

  • @RakeshKumar-bt4dv
    @RakeshKumar-bt4dv 3 роки тому

    फैन अगर जला हुआ है तो मल्टीमीटर रीडिंग दिखाएगा या नहीं दिखाएगा

  • @ashernajmi
    @ashernajmi 2 роки тому

    connection points not clearly shown

  • @shayeeqhmuzammil981
    @shayeeqhmuzammil981 4 роки тому +1

    Slow fan ku kay karna hai

    • @Munny606
      @Munny606 3 роки тому

      change the capacitor, install the round can type not the black square type

  • @SuperApnasangeet
    @SuperApnasangeet 3 дні тому

    ☝️ Wrong connection. Wire with more resistance will be running one.

  • @shamsilyas8885
    @shamsilyas8885 4 роки тому +2

    Bahi jan connection wrong hain....neutral/phase running k 7 dainy hai..
    Jab I starting ko khuch nahen daina....

    • @SNTECHNICAL
      @SNTECHNICAL  4 роки тому

      3 wire me starting me dena hoga
      Running me doge to fan reverse direction me run hoga
      Ap check kr skte h

    • @laxmannagula123
      @laxmannagula123 3 роки тому

      Rong connection

  • @r90135
    @r90135 4 роки тому +8

    Totally wrong

    • @NOT-A-STAR_GAMING
      @NOT-A-STAR_GAMING 4 місяці тому +1

      Why?

    • @hehahu-wx2gn
      @hehahu-wx2gn 2 місяці тому

      if u say its wrong without saying what is the right it means u r totally asshole. specially that it is 100% right and u r the wrong asshole