Probably a call where the owner was having issues and thought some maintenance would fix it. Which is not uncommon. Sometimes units are beyond help and replacing them is the economic solution. Good work.
Curtis, I say that about Christmas Eve and Christmas Day too but then I get emergency calls and a way I go hopefully not this year. We’ll see how it goes. Stay safe and have a Merry Christmas.🇺🇸👊🏼👊🏼✌🏼
Leak is pretty substantial. good find. That Trane has run out of track. I had the old one 36 years ago, it took Katrina to kill it. It was getting rusty but worked like a charm. It's the old saying, they don't make them like they use to. Good video
Hey Curtis, of HVAV Guy not easy being cheesy. I like your podcast/social media, looking thru some comments??? Those all steel frame coils only last 25 years tops. But again it was an engineer who design that coil, not an scientist. Those coils are just some big old thermocouple/battery and will corrode the copper tubing. Looks like time for new up grade. Love you buddy, happy holidays.
Does your PM service include landscaping? I think if put a blurb in there somthing like " Customer is responsible for keeping foliage at least ENTER inches from outdoor unit, and changing filters ENTER. blah blah blah. Merry Christmas Curtis, and thanks for the knowledge and entertainment!
Great catch might as well condemn the whole system try to sell that new inverter system for sure and tell him to trim the shrubs and explain to customers how those shrubs ruined his system by not letting airflow over it therefore overheating the system etc…. Merry christmas
You just tell people how important it is to keep the plants away from the equipment. Yet they still let bushes grow up and all around, and still don't understand why if falls...
there are sequencer start relay there, if not it would have burned up the main relay switch. NEC all electric motors and electric heat shall rated for 125% for it's normal ampere rating.
Probably a call where the owner was having issues and thought some maintenance would fix it. Which is not uncommon. Sometimes units are beyond help and replacing them is the economic solution. Good work.
Curtis, I say that about Christmas Eve and Christmas Day too but then I get emergency calls and a way I go hopefully not this year. We’ll see how it goes. Stay safe and have a Merry Christmas.🇺🇸👊🏼👊🏼✌🏼
Great job Curtis hopefully Santa will bring them a new unit for Christmas thanks for the video
Leak is pretty substantial. good find. That Trane has run out of track. I had the old one 36 years ago, it took Katrina to kill it. It was getting rusty but worked like a charm. It's the old saying, they don't make them like they use to. Good video
Thanks
Nice work Curtis.
Thanks.
That TRANE is DOA and Ready for the R-22 HVAC History Museum. R.I.P. 👍🙏
Great video 👍👍
Thank you 👍
Thanks
Great job,Curtis! Merry Christmas!
They need to make driver sockets with magnets in them.
Enjoy the Holidays Curtis. 🎄
Thanks, you too!
Merry Christmas friend!!!
Thank you Curtis, Enjoy your Christmas break 🍻 Au
will it be a "Twas a Changeout before Christmas"? tune in next time to find out :P
Merry Christmas! I hope this leak detector does a lot better than some of the others you've tried.
Thanks, Merry Christmas to you too!
Fieldpiece for the win. I love my DR82
Curtis i like the d82 that's my go to leak detector. Great job.
Thanks
Hey Curtis, of HVAV Guy not easy being cheesy. I like your podcast/social media, looking thru some comments??? Those all steel frame coils only last 25 years tops. But again it was an engineer who design that coil, not an scientist. Those coils are just some big old thermocouple/battery and will corrode the copper tubing. Looks like time for new up grade. Love you buddy, happy holidays.
Bonsai gardening with the HVAC GUY
Does your PM service include landscaping? I think if put a blurb in there somthing like " Customer is responsible for keeping foliage at least ENTER inches from outdoor unit, and changing filters ENTER. blah blah blah. Merry Christmas Curtis, and thanks for the knowledge and entertainment!
Great catch might as well condemn the whole system try to sell that new inverter system for sure and tell him to trim the shrubs and explain to customers how those shrubs ruined his system by not letting airflow over it therefore overheating the system etc…. Merry christmas
MERRY CHRISTMAS 😎🤟
You just tell people how important it is to keep the plants away from the equipment. Yet they still let bushes grow up and all around, and still don't understand why if falls...
keeping the coil clean is key for keeping system in balance, having good air flow is the secord key.
Is a heat strip thats controlled by a contactor instead of a sequencer hard on the electrical system? Can it lead to brownouts?
there are sequencer start relay there, if not it would have burned up the main relay switch. NEC all electric motors and electric heat shall rated for 125% for it's normal ampere rating.
You need a knipex twin grip
DR82 is a beast
Jumpwr white and green sametime on them heatstrips they are weird
Nvr mind i see u figured it out lol