Economizer part #5

Поділитися
Вставка
  • Опубліковано 23 бер 2017
  • This one is troubleshoot of the simple economizer. This video is part of the heating and cooling series of training videos made to accompany my websites: www.graycoolingman.com and www.grayfurnaceman.com to pass on what I have learned in many years of service and repair. If you have suggestions or comments they are welcome.
    If you are a homeowner looking to repair your own appliance, understand that the voltages can be lethal, the fuels are highly flammable and high pressures are used. Know your limits.

КОМЕНТАРІ • 44

  • @Kirkdrive
    @Kirkdrive 2 роки тому +1

    My Hvac/r school instructor referenced your videos often during class. I subscribed to this channel back then. I just completed my first year in the field and I’m still getting so much good info from GFM. Thank you, sir.

  • @hg2.
    @hg2. 3 роки тому +1

    Great intro series to Economizers.
    Thank you.

  • @guardianmn
    @guardianmn 5 місяців тому +1

    Good to get a refresher. Hope all is well with you sir

  • @saltrue1555
    @saltrue1555 5 років тому

    Thank you Very much for your teaching I’ve been learning from your teaching God bless you for all your teaching

  • @robertarnold6672
    @robertarnold6672 7 років тому

    Awesome video series! I really had no ideal how economizers worked. I thought they just opened up to let cool air in & that was it. I did not know about the relationship between the economizer & the return & how the two work together to control the air temp. The basic explanation of the input sensors was good too.

    • @grayfurnaceman
      @grayfurnaceman  7 років тому +1

      Thanks for the support.
      GFM

    • @robertarnold6672
      @robertarnold6672 7 років тому +1

      Thank you GFM for sharing your knowledge & expertise with the rest of us who have a strong desire to learn.

    • @grayfurnaceman
      @grayfurnaceman  7 років тому

      Welcome
      GFM

  • @binaypalgill4778
    @binaypalgill4778 3 роки тому +1

    What is reason for jumper wire between t and t1. Can you please explain that? And also if you ever come across replacing these Honeywell economizer module with Honeywell jade controller, please please make a video.
    Thanks a lot. Very informative

  • @dsowonikjr
    @dsowonikjr 6 років тому

    great videos, very informative

  • @rocketstool
    @rocketstool Рік тому

    Jade economizers are the only way to go.

  • @PBS-nm1uu
    @PBS-nm1uu 7 років тому

    thanks for all your videos very informative please do more

  • @simohvac9222
    @simohvac9222 3 роки тому

    very good video thank you

  • @capitolrefrigerationheatin7501
    @capitolrefrigerationheatin7501 7 років тому +2

    Nice post, a lot of techs bypass economizer because they dont understand it.

    • @grayfurnaceman
      @grayfurnaceman  7 років тому

      So true
      GFM

    • @WildRebel69
      @WildRebel69 7 років тому

      Capitol Refrigeration,Heating,and Cooling some disconnect them. especially here in az because they're worthless

    • @grayfurnaceman
      @grayfurnaceman  7 років тому

      I don't think they are worthless in the desert. The cool nights could be used to cool down the high thermal mass of the building.
      GFM

    • @WildRebel69
      @WildRebel69 7 років тому

      grayfurnaceman during our summer's it doesn't get below 90 deg for over 3 to 4 months. On roof tops because the sun barrels down on us damn near all year its hotter. So your tstat may call for cool but that damned door opens sucking in hot air. most of my calls here in az that have been for ac blowing hot air was because of these systems

    • @WildRebel69
      @WildRebel69 7 років тому

      grayfurnaceman and that's the temp at night. it's average daily temp is 117

  • @972958
    @972958 7 місяців тому

    Mines doesn’t have an outdoor sensor control, mines has the free cool light on but no action.

  • @andreagate542
    @andreagate542 4 роки тому

    Thank you for the vid!! What does jumpering T1 and T do? Forgive me if you already explained this in your prior videos

  • @666miguel99
    @666miguel99 Рік тому +1

    Hey boss, I have a carrier package unit. I'm trying to figure out why it's only calling for Y2 cooling Y1 doesn't get a call. Any tips on that?
    It's pretty cold out right now, it's about 53°. And the room that we are trying to cool produces a lot of heat so it's about 85° in there. And I can't get the economizer to mix any air. I have the same control unit that you have in this video.

    • @grayfurnaceman
      @grayfurnaceman  Рік тому +1

      I think you have an economizer problem. With low outside temps, Y1 is outside air. Y2 is compressor. Possible failed motor. Happy new year.
      GFM

    • @666miguel99
      @666miguel99 Рік тому

      @@grayfurnaceman thanks for respondint, I watched your videos and determine that the actuator is good. This unit doesnt have an actual mixed air sensor installed however they did plug in the violet and pink wire onto the economizer (T1, T) and at the blower compartment they crounded the ends to the chassi... could that be the issue? should thye just not be plugged int on the economiser.. essentially it's jumpered and tied to chassi ground... strange but I don't understand it. Thanks alot for responding BTW!!

  • @xraybravo7180
    @xraybravo7180 3 роки тому

    To do this test jump the SO and SO+ and T1 and T2 do you have to have a call for AC to drive the motor wide open?

  • @rexbahr3416
    @rexbahr3416 6 років тому

    Now the problem is, What if the building is sealed, that is no flow? In the Donut shop we have a big exhaust fan and I would like for the damper to stay open most of the time to allow air in to the fryer hood so we have better exhaust flow.

    • @grayfurnaceman
      @grayfurnaceman  6 років тому +1

      Your problem is more complicated than that. The exhaust system for any cooking operation should have an exhaust fan for the hood, and a make up air fan to bring outside air into the exhaust hood area. The 2 fans must be interlocked so they both come on at the same time. They must also be set up so that exhaust and makeup air is balanced. The economizer damper is not part of that system.
      GFM

  • @xweiliable
    @xweiliable 3 роки тому

    i have a preschool and I need to have the economizer open at all time to get fresh air. how do I overwrite economizer to get it to open?

  • @dcmoor4662
    @dcmoor4662 Рік тому

    Will this economizer require a 2 stage t-stat to function properly?

  • @longhongsamat
    @longhongsamat 4 роки тому

    How to check if the motor is good or bad?

  • @1ndependenceday1
    @1ndependenceday1 7 років тому

    so you saying if temperature sensor don't move actuator while it's jump it's bad sensor

  • @mikemalone6103
    @mikemalone6103 7 років тому +1

    Why bother disconnect anything, just jump out the sensor with wires connected

  • @joekatynski8171
    @joekatynski8171 7 років тому

    The carriers are coming through with duel epalthy controls now

    • @grayfurnaceman
      @grayfurnaceman  7 років тому

      There are so many new ones out there. This one is the very simplest of them.
      GFM

    • @joekatynski8171
      @joekatynski8171 7 років тому

      This video segment has been great. I just did a maintenance today that has 15 rooftops was able to diagnose 5 of the units with bad economizer motors. 55* outside and units were running mechanical cooling and dampers were closed. Motors were siezed

    • @grayfurnaceman
      @grayfurnaceman  7 років тому

      Glad it helped.
      GFM

    • @jewdali1
      @jewdali1 7 років тому

      Hey Joe you mean enthalpy controls?

    • @joekatynski8171
      @joekatynski8171 7 років тому

      Lol yes didn't realize I spelled it wrong