We have an Udor Delta 75 and the pressure keeps rising. We will have it set at 350-400 PSI on the regulator then after a few minutes it shoots way up at random to 600+ PSI. Any Ideas?
Sound like it may be regulator issue. Hard to troubleshoot based on this comment alone but I would start there. Feel free to call us with any questions. 800-706-9530
Suction lines can be found pulling from the top or from the bottom of the tank. We place ours on top to eliminate any chance of a bottom tank fitting leaking. The important part is to always have a strainer before the pump.
I have a DP-392.1 DIAPHRAGM PUMP. WHAT WOULD CAUSE THE OIL IN THE RESERVOIR TO SLOSH AROUND?
We have an Udor Delta 75 and the pressure keeps rising. We will have it set at 350-400 PSI on the regulator then after a few minutes it shoots way up at random to 600+ PSI. Any Ideas?
Sound like it may be regulator issue. Hard to troubleshoot based on this comment alone but I would start there. Feel free to call us with any questions. 800-706-9530
Very helpful, thanks for the tips.
Hello guys, suction filter always connect to tanks at the top and not at the bottom? I am setting up a udor zeta 40 myself, thank you, great video!
Suction lines can be found pulling from the top or from the bottom of the tank. We place ours on top to eliminate any chance of a bottom tank fitting leaking. The important part is to always have a strainer before the pump.
@@GregsonClarkSpraying Thanks very much for prompt reply, very helpful, many thanks
Hi