WYE DELTA CONVERSION &ACTUAL APPLICATION | Marine Elecrician

Поділитися
Вставка
  • Опубліковано 29 кві 2022
  • We have a small Deck Equipment which is a 220V 3P and the available outlet onboard is 220V single phase and 440V 3P.
    I did the actual conversion for your reference.
    please do like, share and subscribe.

КОМЕНТАРІ • 129

  • @josecaballero7267
    @josecaballero7267 2 роки тому +8

    Hello lecky jake, I'm an Electro-technical cadet from Panama, I would like to thank you a lot for this channel because is a good help for us the beginners in this carrer, I wish you a good campaing if you are on board at this moment.

    • @edylmarcedeno3664
      @edylmarcedeno3664 8 днів тому

      Lecky jake is in god hands right now. He died last month 😢

  • @onderdinc7906
    @onderdinc7906 2 роки тому +2

    I'm learning a lot from you. Please keep more videos.

  • @mrbigb12
    @mrbigb12 2 роки тому +5

    Very basic information that majority of electricians out there don't fully understand. Coming from a motor reminder here :) great video, good work.

  • @gassanali8667
    @gassanali8667 10 місяців тому

    i've always wanted to find a way to run 220 3p motor with a supply of 380 3p and here i have it. thanks a lot for the blended explanation, both theory and practical. will keep an eye on your channel for great and useful content like this. wish you a great day!

  • @rishabhparmar6569
    @rishabhparmar6569 2 роки тому +4

    Thank you Lecky jake , these types of vedios are very beneficial for beginners like me , thank you and keep making these types of vedika in future also.

  • @zuberkhan5895
    @zuberkhan5895 Рік тому

    Thnx so much jake..u make it so simple to understanding anybody. I like it

  • @ismailbakhiet5773
    @ismailbakhiet5773 2 роки тому

    Thank you for your explanation, I hope you more success in your job

  • @justin_leyson
    @justin_leyson 2 роки тому

    Wow kaya dito ako lagi nanunuod eh kasi ang linaw ng explanation ninyo. Hindi masakit sa ulo. Salamat po sir

  • @igortabulynsky2253
    @igortabulynsky2253 Рік тому

    a good practical lesson for the correctness of ordering any ship equipment ... And what would you do if there was no electrician on board .... now it’s a fairly common event .... As a result, our author simply saved Company from unforeseen cash costs........ Well Done !!!

  • @danilocasidsid5222
    @danilocasidsid5222 Рік тому

    nice work leckyjake na refresh nanaman ang mga ka lecky salute you sir god bless

  • @liam3284
    @liam3284 Місяць тому +1

    At 440v, the star wired motor will get 15% above rated voltage. Each coil will see ~253 volts. Because of vector addition, the voltage at the star point is the line voltage divide by square root of three.

    • @WorryNot-ep8ci
      @WorryNot-ep8ci 13 днів тому

      Is it safe for the motor with that 15% more voltage ?

  • @osmankaya9664
    @osmankaya9664 2 роки тому +1

    Thank you Sir for invaluable contents

  • @h.m.tun8420
    @h.m.tun8420 2 роки тому

    Thank you so much for sharing your knowledge. Thanks a lot.

  • @kuldeepsingh8486
    @kuldeepsingh8486 2 роки тому

    Thank you sir for making some basic technical video for beginners this video very informative. Make some more video like this. Thank you

  • @msaad7888
    @msaad7888 4 місяці тому

    I sea your elictrical lecture very aprase your video and get knowledge.very good sir.

  • @BarkoTv
    @BarkoTv 2 роки тому

    More power sayo sir. Thanks you for sharing

  • @jesonabejuela3737
    @jesonabejuela3737 2 роки тому

    Thank you for this vedio sir, another learnings for me.

  • @denzelespenilla147
    @denzelespenilla147 Рік тому

    thank you leki jake. very informative

  • @juliusbosquehamilton1075
    @juliusbosquehamilton1075 Рік тому +1

    Great video 📸

  • @mozesleroycruz8827
    @mozesleroycruz8827 Рік тому

    Hi sir. aspiring ETO here 😊 i'm watching your videos.... at nagulat po ako bigla po kayong nagtagalog... hehehe godbless po.

  • @bekeleasegidew463
    @bekeleasegidew463 11 місяців тому

    I really appreciated, its good info elec. I'm eto cadet.

  • @julztv1231
    @julztv1231 4 місяці тому

    hello master salamat dami ko natutunan dto sa mga video mo

  • @aaronjettroehidalgo534
    @aaronjettroehidalgo534 9 місяців тому

    Great Video sir! Thanks

  • @ericxandercustodio9627
    @ericxandercustodio9627 3 місяці тому

    Galing mo sir. Saudi Arabia

  • @s895s607
    @s895s607 2 роки тому

    Thank sir, your video is very good.

  • @seamensclubltd7603
    @seamensclubltd7603 Рік тому

    ❤ Great video!

  • @mangeshsingh4326
    @mangeshsingh4326 2 роки тому +1

    Thanks sir... Really useful

  • @pinoy_electrician
    @pinoy_electrician 2 роки тому

    Pinoy ka pala sir. Akala ko po dati koreano kayo. Haha. Amg galing mo sir. Sana maging kasing galing mo po ako. Godbless always po.

  • @ChandanaPriyantha-pq3uv
    @ChandanaPriyantha-pq3uv 25 днів тому

    Thank you sir improve the electrical knowledge,You are the great discussed the lessons ,

  • @bernardsajibuden382
    @bernardsajibuden382 2 роки тому

    Thank you so much sir

  • @joeflotta
    @joeflotta Рік тому

    fuckin love this guy!

  • @RolandoEspiritu-ti2gs
    @RolandoEspiritu-ti2gs 2 місяці тому

    Thank u sir

  • @mithileshramteke3882
    @mithileshramteke3882 2 роки тому

    Thank you sir

  • @etosaravanan4572
    @etosaravanan4572 2 роки тому

    Thanks sir .

  • @user-ys9th3xb9k
    @user-ys9th3xb9k Рік тому

    Very simple

  • @ritcheromerotagolino8507
    @ritcheromerotagolino8507 Рік тому

    Thanks sir, 😊

  • @faizzainal4354
    @faizzainal4354 7 місяців тому

    thank you sir lecky jake

  • @johnalbertmamaril4496
    @johnalbertmamaril4496 2 роки тому

    thank you...

  • @jeromegacusan6302
    @jeromegacusan6302 2 роки тому +3

    If two loads is connected in a series connection and has a supply of DC. Simple you just add the voltage..But If it is in a three phase system and the loads is wye connected ,the rated voltage must be multiplied by √3.

    • @mr.bigd-ave4786
      @mr.bigd-ave4786 Рік тому

      This is right.. I got confuse about 3phase AC 230V motor from delta connection to Wye Connection.. Yes if DC it will add up but in AC 3phase system??

    • @liam3284
      @liam3284 Місяць тому

      A 230v motor in delta will operate on 400 volts in wye. In Europe, 230 volt single phase loads are connected between line and neutral. The supply is always 400/230Y.

  • @renelemueli.ochenta8837
    @renelemueli.ochenta8837 2 роки тому

    Tnks leky

  • @AAminy
    @AAminy 3 місяці тому

    thanks

  • @faysalrusho3634
    @faysalrusho3634 2 роки тому +4

    It is not safe bro.it will burn the winding eventually. because in delta connection, phase current= line current/√3. But when you connect it in wye then, phase current=line current, which will be higher than the delta connection. So, winding will be overheated due to high phase current and possibly burn. By the way voltage on each phase will be 255v in wye connection and it is designed for 220v. So i believe, you do know what will happen then.

    • @Link-tt6mw
      @Link-tt6mw 2 роки тому

      I dont how he converted it into 440V. But I think you also got the wrong idea because the Voltage @ Delta in Line to Line = Phase and The Voltage @ Wye in Phase = Line to Line /sqrt of (3). Therefore the current @ wye will become smaller since 220/sqrt(3)=127.

    • @faysalrusho3634
      @faysalrusho3634 2 роки тому

      @@Link-tt6mw bro about current in wye, i think you are wrong. Because in wye connection phase and line is in series. So phase current= line current. In delta phase current=line current/√3. Please check your book.

    • @Link-tt6mw
      @Link-tt6mw 2 роки тому

      @@faysalrusho3634 yup you are right. What i am referring to is the current in wye is smaller than the current in Delta. Because the supply line voltage in delta is equal to the load voltage.

    • @Link-tt6mw
      @Link-tt6mw 2 роки тому

      @@faysalrusho3634 that's why we have wye delta starter in our motor control. Because in wye connection we have smaller current than the connection at delta.

    • @liam3284
      @liam3284 Місяць тому

      The line current will be less, winding current the same (check the calculation with resistors). Only problem is the coils are getting 250+ volts when rated for 220 volts. If the motor is not designed well, the higher voltage will cause magnetic saturation.

  • @0dbm
    @0dbm 2 роки тому

    ❤️

  • @rthony7780
    @rthony7780 2 роки тому +13

    The calculation is wrong. The phase/winding voltage in a Wye connected motor is
    (Line Voltage)/sqrt of 3
    440/sqrt of 3 = 254.3 Volts
    Therefore, each winding is subjected to a Voltage of 254.3 volts, when it is supposed to be only connected to 220v.
    Is this possible? Yes but it will greatly affect the motor's lifetime and health and it will also run at a higher temperature due to more current running in the windings compared to its supposed rated operating current.
    Dont take this the wrong way tho Sir Lecky Jake, I really find your videos very helpful and informational, saludo!!!

  • @armandovilla6039
    @armandovilla6039 2 роки тому

    please make a video about avr droop settings explanation. bonvoyage ka leckyjake.👍👍

  • @nathanielreid4967
    @nathanielreid4967 2 роки тому

    👍👍👍👍❤❤❤❤

  • @mubashir-life-routine7866
    @mubashir-life-routine7866 2 роки тому

    👍👍👍👍👍👍👍

  • @singhraju4000
    @singhraju4000 2 роки тому +3

    Good day Sir, Your video are very valuable, please make the video on 440 volts motor starter panel control circuit troubleshooting. Thanks 👍👍

  • @dravenshoes4553
    @dravenshoes4553 2 роки тому +2

    Sir good day.
    What is your bases or how you justify if electric three phase motor o compressor need to run in part winding operation or wye dleta operation.
    Pleased make a video for this topic.
    Thank you in advance.

  • @almcken2
    @almcken2 2 роки тому

    Can you talk about the Fire on the Carnival Freedom ship. What you think might have caused it?

  • @normansale1542
    @normansale1542 2 роки тому +1

    Sir Lecky is that really the marking partner for the 220 volts coz most motors that I open states u1 and W2
    V1and u2
    W1 and v2 that's for the delta

  • @andrewsmart2949
    @andrewsmart2949 2 роки тому

    interesting

  • @kerbee9453
    @kerbee9453 Рік тому

    In direct online(DOL) starter always connect the motor cables in WYE/STAR. It is not advisable in bigger motor ratings as the inrush and running current is high as compared to delta. in VFD even if it is small motor you should connect it in delta.

    • @rajatawasthi4769
      @rajatawasthi4769 Рік тому

      But in star we don't get enough speed

    • @rajatawasthi4769
      @rajatawasthi4769 Рік тому

      For small motors we can use Delta connection

    • @kerblow2017
      @kerblow2017 Рік тому

      @@rajatawasthi4769 there are things you need to consider before doing the connection. Energy wise, application, what type of controls they used. Don’t be stupid unless you want expensive repair. If you used delta using DOL then you have high value of running current means high electric consumption bill and the possibility of burning the motor winding. Don’t look at on the speed because it is already measured during the design process.

  • @alexpornes7182
    @alexpornes7182 2 роки тому

    Hule!! Nagtagalog kadin lecky jake hahahha

  • @cesarivanborling1964
    @cesarivanborling1964 2 роки тому

    Pilipino ka pala sir😆

  • @MANI-op7yb
    @MANI-op7yb Рік тому

    This y connection is possible for using for long time rotation?

  • @DGS8
    @DGS8 2 місяці тому

    Hello leckyjake, How do you convert 3phase 380v motor to 3phase 220v?

  • @hurontoikiy7036
    @hurontoikiy7036 2 роки тому

    Howdy sir
    Greeting from Spain 🇪🇸 🛳

  • @unobono
    @unobono 2 роки тому +1

    Hey Jake. I'm an 2nd engineer on an old tug boat. Do you think I can learn more in a newer boat big tanker or a tug? Thanks

    • @leckyjake
      @leckyjake  2 роки тому

      i suggests to go a bigger vessel. you will have a lot of hands on to a different machineries which will enhance your capabilities

  • @andualemsisay2764
    @andualemsisay2764 Рік тому

    Thank you for the lesson as always. i have a question: the motor is made for 220v so does insulation of motor, is it okay for insulation of motor(winding) to supplied it with 440v ? tnx.

    • @rongultiano664
      @rongultiano664 3 місяці тому

      Wye connection, so it will become series 440V it will divide into two coil. Still 220V

  • @elypenaredondo283
    @elypenaredondo283 Рік тому

    Hello leckyjake . Ask k LNG may experience k b s oil Tanker .. panu po checking ng cargo control console KC nag shutdown sya..

  • @dimitararabadzhiev
    @dimitararabadzhiev 10 місяців тому

    and 440 is 3 phase systemm, also 220 V is a 3 phase system in USA standart NEC , but un europe 220 is a single phase , from here is a confusion check ou video "split phase system " in usa and compare it with 3 phase system in europe

  • @hernanbensurto573
    @hernanbensurto573 Рік тому +1

    Brother jake. Pwd bang ung 440v 3p ay supllyn ng 400v 3phd.? Slmat sa sagot GOD BLESS.

  • @seaspidermariner1565
    @seaspidermariner1565 2 роки тому

    How to join assistant AIR CON technician in cruises lines any job site.

  • @anburaj7205
    @anburaj7205 10 місяців тому

    But changing to Wye configuration will cause current increase doesnt that affect the motor

  • @joewebb4836
    @joewebb4836 Рік тому +1

    not possible WITHOUT DUAL VOLTAGE MOTOR OR GOING THROUGH TRANSFORMER. DELTA LINE TO LINE IS THE SAME AS WYE LINE TO LINE.

    • @dimitararabadzhiev
      @dimitararabadzhiev 10 місяців тому

      you are right it is impossible, but someone is trying to ..... the corect way is this - ua-cam.com/video/nuhxqZJYKhQ/v-deo.html, the european method to switch from a 400 V to 220 V include a power capacitor

  • @myatnoelwin7346
    @myatnoelwin7346 Рік тому

    Mr jake
    I saw you changed power plug.
    1) why did u change?
    2) how did you change?

    • @jjhves
      @jjhves 4 місяці тому

      1. Because the 220V 3ph plug won't fit into the 3ph 440V outlet outside.
      2. Chop off the 220V 3phase plug and wire in a new 440V 3 phase plug.

  • @denicemunar1176
    @denicemunar1176 Рік тому

    that`s ok but in a long run it`s not advisable because the winding and insulation heat up more easily to cause a fire.

  • @blaise4083
    @blaise4083 Рік тому

    Does converting from delta to star effect the speed?
    Also I think in star, the current will increase to 4.041 Amp

    • @liam3284
      @liam3284 Місяць тому

      It was converted to star, but also the voltage is also increased. The voltage on each pole will be almost the same, so the speed, slip, and current will be the same. However the insulation will have more stress.

  • @tellomlbbblays9313
    @tellomlbbblays9313 Рік тому

    Good pm sir.
    Pwede pa explained diba pag delta is Yung motor naka high speed? At kapag wye is naka low speed? Bakit sa video mo ay mababa voltage Ng delta kesa WYe?
    Salamt sa explain sir. 🙏💕💕💕

  • @bruhhhbeast3761
    @bruhhhbeast3761 2 роки тому +1

    But sir, why add the two 220 voltage? Isn't the formula fo wye connection is VL = √3•VΦ

  • @travelhumor6201
    @travelhumor6201 Рік тому +2

    Hi sir, I'm concern about the ampacity of the conductors and it may damage in a long run, because if the voltage increases, current also increases. And the insulation of the motor may deteriorate since higher voltage is being applied where the motor is designed only for 220V.

    • @rajatawasthi4769
      @rajatawasthi4769 Рік тому +2

      Line voltage is the same

    • @johnpaulminguito
      @johnpaulminguito Рік тому +1

      current is the same coz phase voltage is the same

    • @voltelectricians9984
      @voltelectricians9984 11 місяців тому

      In this case the motor will even draw little current when connected 440 3p, when voltage increases current reduces, compared to what it could draw when connected to 220v 3p.

  • @Tulfonatic-sarcasticsm
    @Tulfonatic-sarcasticsm Рік тому

    hello Sir just a Clarification at your diagram say @6:12 Delta Connection U1V2 , V1W2, W1V2, but in actual @11:20 says U1W2, V1U2 W1V2.... Does affect if we follow ur diagram at 6:12 in real world?? thank you sir

  • @emadsiddig6631
    @emadsiddig6631 2 роки тому

    Nice video please dear no gevie me answer why please

  • @danharoldsebastian7504
    @danharoldsebastian7504 2 роки тому

    Good morning sir leckyjake.
    BSEE student po ako at graduating na po. after po mag board exam nagbabalak po ako maging katulad nyo po na eto. bale naaral ko na po mga dapat ko gawin para maging eto. tanong ko lang po ano po ang mga training or tesda courses na dapat kong pasukin para po ngayon palang magkaron na ako ng knowledge sa pag troubleshoot ng ibat ibang machines na ginagamit sa barko. maraming salamat po

  • @joewebb4836
    @joewebb4836 Рік тому

    I kinda wanted to see the motor nameplate.

  • @santossaturday9889
    @santossaturday9889 2 роки тому

    Sir ask kulang kung my capitor yan motor sa 220 volts

    • @lawrencejedbundac3707
      @lawrencejedbundac3707 2 роки тому +1

      Gumagamit lang ng capacitor sir pag single phase yng motor, pag 3 phase wala na.

  • @rnsevirich6288
    @rnsevirich6288 2 роки тому +1

    Pag Y connection sir di ba dapat Line Voltage = Phase Voltage x √3?

  • @marlondoronia2947
    @marlondoronia2947 2 роки тому

    pwede bang vice versa?440 3p to 220 3p?

  • @mohasinkapadvanji601
    @mohasinkapadvanji601 2 роки тому +3

    Sir its not 440v....when you leave 3rd phase open then only it will be 440 between 2 phase... according to your connection it will be 220*√3 ....it will work but not with full efficiency .... kindly check voltage with voltmeter

    • @SwissBrahmin
      @SwissBrahmin 2 роки тому +4

      the line voltage is supplied from the ships transformers at 440V. Each winding of the motor will see a phase voltage of 440V / √3. So approx. 250V, which is slightly higher than the rated insulation value of the windings.

    • @mohasinkapadvanji601
      @mohasinkapadvanji601 2 роки тому +4

      You are right but see the video of his explanation 220+220= 440 it can't be like that.

  • @dimitararabadzhiev
    @dimitararabadzhiev 10 місяців тому

    there is diference between star delta in europe and usa , such diference is like 50Hz and 60 Hz . I will show you link to USA standart star delta conection or how to connect electrical motor from 440 V to 220 V - ua-cam.com/video/nuhxqZJYKhQ/v-deo.html

  • @Link-tt6mw
    @Link-tt6mw 2 роки тому +2

    Hindi po ba mas bababa dapat ang Voltage sa Load kapag ginawang wye connection kasi magiging 220V 440V/sqrt of (3). Naguguluhan ako patulong naman guys pano naging 440V talaga yung Voltage non? 😁

    • @antonioreyes7476
      @antonioreyes7476 2 роки тому

      The supply voltage is 440V, since he converted the connection to wye so the motor phase voltage will be 250V(440/1.73). Still a bit higher than 220V rated voltage, it will affect the motor lifespan in the long run. I am sure that Jake is fully aware including all mathematical calculation. But for simpler illustration, he opted to explain it that way.

    • @Link-tt6mw
      @Link-tt6mw 2 роки тому

      @@antonioreyes7476Sir I just want to ask, Since it's in wye connection and the voltages in each phases became smaller. Is the motor will become slower? Thanks, btw I'm still a student and still learning 😁

    • @antonioreyes7476
      @antonioreyes7476 2 роки тому +1

      @@Link-tt6mw yes and no. In general, the motor speed slows down in wye connection because Vp is smaller than Vl, that's why we have soft start or wye/delta starter. But for Leckyjake example, the motor runs at rated speed or even higher because that motor is rated 220V, and the phase voltage is 254V (supplied by 440V and motor is configured in wye).

    • @Link-tt6mw
      @Link-tt6mw 2 роки тому

      @@antonioreyes7476 Thank You sir! ❤️

    • @trcostan
      @trcostan Рік тому

      @@antonioreyes7476 I would like to know what the voltages actually are on the ship I would have expected 240/415 like most of the world uses! 220/440 seems like North American 240/480 power but that’s seems odd then if you have single phase 220 outlets? Guess I’m confused on what standard they ship is really using!

  • @dvagabondo
    @dvagabondo Рік тому

    440/1,73=254,3 not 220 ))

  • @acmell3173
    @acmell3173 Рік тому +1

    Pilipino ka po ba idol😊?

  • @emadsiddig6631
    @emadsiddig6631 2 роки тому

    Send before fecbook

  • @josecaballero7267
    @josecaballero7267 2 роки тому

    Hello lecky jake, I'm an Electro-technical cadet from Panama, I would like to thank you a lot for this channel because is a good help for us the beginners in this carrer, I wish you a good campaing if you are on board at this moment.

  • @renelemueli.ochenta8837
    @renelemueli.ochenta8837 2 роки тому

    Tnks leky