Thanks! Its very informative!
Thankyou sir for this knowledgeable video
thank you for this. where did the 32 come from?
Could you please share the timeline for that value?
@@pharmaengineering hello, its at 7:17-7:23. thanks!
It's a formula to estimate the volume occupied by the reactors torispherical bottom dish i.e., (pi/32)*Di^3
@@pharmaengineering got it, appreciate the reply!
How can we calculate Td24 value based on Dynamic DSC experiment?
Take 2 data points from a significant exothern and use arrhenius law to establish the pre-exponential factor, activation energy and calculate Td24
Can we calculate tip speed of two different types of agitator small scale propeller and large anchor L/D is same but D/d not same
No, if the process demands a specific mixing pattern, matching tip speed of two different impellers won't suffice
@@pharmaengineering if it is homogenous mixture
Power per unit volume is the best method for two different impellers
@@vrganesh9841 most of the cases if it's a homogeneous mixture there won't be any issue,However if the operation demands a specific kind, then we have to
@@pharmaengineering thank you sir
Thank you
Thanks! Its very informative!
Thankyou sir for this knowledgeable video
thank you for this. where did the 32 come from?
Could you please share the timeline for that value?
@@pharmaengineering hello, its at 7:17-7:23. thanks!
It's a formula to estimate the volume occupied by the reactors torispherical bottom dish i.e., (pi/32)*Di^3
@@pharmaengineering got it, appreciate the reply!
How can we calculate Td24 value based on Dynamic DSC experiment?
Take 2 data points from a significant exothern and use arrhenius law to establish the pre-exponential factor, activation energy and calculate Td24
Can we calculate tip speed of two different types of agitator small scale propeller and large anchor L/D is same but D/d not same
No, if the process demands a specific mixing pattern, matching tip speed of two different impellers won't suffice
@@pharmaengineering if it is homogenous mixture
Power per unit volume is the best method for two different impellers
@@vrganesh9841 most of the cases if it's a homogeneous mixture there won't be any issue,
However if the operation demands a specific kind, then we have to
@@pharmaengineering thank you sir
Thank you