- This is a multi-function inverter charge, combining functions of inverter, MPPT solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
Features:
✅6.2KW Pure Sine Wave Inverter
✅120A Built-In MPPT Solar Charge Controller
✅Multiple Charging & Output Modes
✅Full System Protections
✅Support for BMS Communication
✅Support Up to 12 Units in Parallel Connection
______________________________________________________________
Email:
support@powmr.com
See you in my next video! :)
______________________________________________________________
1: Efficient BMS Communication: POW-HVM6.2M-48V-N
• Efficient BMS Communic...
2: How to Setup the PowMr 4.2KW Hybrid Solar Inverter?
• How to Setup the PowMr...
3: How to Setup the PowMr 10.2KW Hybrid Solar Inverter
• How to Setup the PowMr...
Very useful
Good job, thanks.
make a video on connecting the jk bms inverter with the CAN bus
thank you for sharing
It will be easier to describe the problem: PowMR 6.2 KW inverter The installation of photovoltaic panels is 3.6 KW, the inverter is not connected to the battery and is not connected to the grid. I have a 2 KW water heater connected to the inverter output. The inverter will not turn on the heater even in full sunlight. If I turn on a 500-watt receiver instead of a heater, the inverter produces electricity. How to set the inverter to provide current all the time regardless of the load, I want it to provide as much current as is currently in production and not to turn off when I turn on a larger load.
Photovoltaic installation:
225Wx16=3600W
36.9Vx16=295.2V
Inverter Settings
ua-cam.com/video/l9n7lgL5nu4/v-deo.htmlfeature=shared
I guess answer will be NO, yet it can be a feature to implement for this inverter in next releases.
question is:
can they merge phases in parallel mode?
for example I do connect 2 or 3 inverters inputs to different phases
and I want to get more powerful single phase on outputs
This model supports single-phase and three-phase parallel use.
make a video on connecting the jk bms inverter with the CAN bus@@PowmrSolar
3F parallel output 380V or 400V? the mitsubishi zubadan pump wants 400v so i don't know if this unit will work with that
A single machine can output 240V in single phase, and the machine can operate in parallel with three phases.
How many devices can be parallable?
Up to 12 units with the LIP version.
Good upgrade of battery terminal. what is the pc software for the inverter?
This model does not have pc software. Please use wifi module for monitoring.
@@PowmrSolarmake a video on connecting the jk bms inverter with the CAN bus
hello
I'm very interesting in this inverter mode.
is it necessary to connect both inverters to same battery?
will it work in next situations:
inv1: PVarray1+utility+battery
inv2: PVarray2+utility
OR
inv1: PVarray1+utility+battery1
inv2: PVarray2+utility+battery2
thanks for your answer.
2 machines can be connected to the same battery. The machine will work according to your settings. After paralleling, the slave will follow the host's settings.
@@PowmrSolar
can or should? I know it can be connected to same battery. But is it mandatory condition?
Is it allowed to connect separate batteries per inverter? Considering batteries require same voltage/amps setup.
@@Alexmrg123 from user manual: WARNING! Be sure that all inverters will share the same battery bank. Otherwise, the inverters will
transfer to fault mode
ich ersuche um ein Video, wo ich einen Generator anschließen kann Vielen Dank
Can you please tell me what the energy consumption in standby mode is for each of the three inverters?
Less than 124W.
@@PowmrSolar ... so 3 inverters would use less than 372W?
Can you use only 2 inverters to get dual-phase system?
Nope.
❤❤❤❤❤🎉🎉🎉🎉🎉
Does it can be used in parallel with no battery at all?
Nope, if you want to use it in parallel, you must connect the batteries.
can it communicate with FelicitySolar lpbf48300 battery via RS485 or CAN?
my current MUST inverter can't comunicate with battery
You need to consult your battery manufacturer for this.
@@PowmrSolar
battery manufacturer says:
"Compatible Inverters Felicitysolar/Deye/Luxpower/Growatt/Voltronic/Sunsynk/Megarevo/Victron/SRNE/Solis/MPPsolar/Afore/SOFAR/CHISAGE ESS"
I also found in your manual there is some specific configuration for PYLONTECH batteries.
So I wonder it may also work with other manufacturers (with some additional configuration?)
@@Alexmrg123 Yep, the pylontech protocol.
@@PowmrSolar
thanks.
I guess felicity battery also works via PYL protocol.
So should work with PowMr as well.
at least it states in their manual:
Voltronic/Kodak/RCT/Mecer Axpert and InfiniSolar series communication.
1. Communication Cable Pin: 5,6(Felicity, any port)--3,5(Inverter, BMS port)
2. Setting steps on inverter: Setting→14→PYL.
3. Sign of successful communication: Can check the battery SOC on inverter
@@PowmrSolarmake a video on connecting the jk bms inverter with the CAN bus